36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Similar documents
36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36H SERIES Combination Gas Valve

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G96 Series BASOTROL Dual Operator Valve

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Natural Gas to L.P. Gas Conversion Kit

VR8305 Direct Ignition Combination Gas Control

/2004 US/CA

Installation Instructions

VR8205S,T Direct Ignition Combination Gas Controls

G92 Series BASOTROL Automatic Pilot Gas Valve

Your safety and the safety of others are very important.

GM-7000 Series CE Approved Gas Control Valve

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

Dual Solenoid Gas Valve Installation

Natural Gas to L.P. Gas Conversion Kit

Propane Conversion Kit Instructions

Instructions for High Altitude Conversion

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

SPECIFICATIONS ATTENTION

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Installation Instructions

VR8200A Continuous Pilot Combination Gas Controls

VR8105, VR8205, and VR8305 Direct Ignition Combination Gas Controls

VS8420 Millivolt Gas Valve

INSTALLATION GUIDE Gas Rangetops

GM Series Dual-Block Multi-Function Gas Control Valves

ACCESSORY KIT INSTALLATION MANUAL

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

VR8104, VR8204, and VR8304 Intermittent Pilot Combination Gas Controls

BGC258 Series BASOTROL Gas Valve

installation instructions

Propane Conversion Kit Instruction

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

WARNING: FOR OUTDOOR USE ONLY

Propane Conversion Kit Instruction

Conversion instructions from natural gas to propane

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Propane Conversion Kit Instruction

Installation Instructions For Natural Gas Conversion

Gas Conversion Kit Pilot Ignition Heaters

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

VR8305 Direct Ignition Dual Automatic Valve Combination Gas Controls

SPECIFICATIONS CAPACITY

VR46.5V(A)/VR86.5V(A) SERIES

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

INSTALLATION INSTRUCTIONS

SL G3. Warning

Types 749B and R130 Changeover Manifolds

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

Gas Fired Residential Heating Boilers

USER S INFORMATION MANUAL

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

C645A-E Pressure Switches

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

FIREPLACE INSTALLATION

INSTALLATION AND OPERATION INSTRUCTIONS

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

Natural Gas Conversion Kit

Installation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas

G95 Series BASOTROL Single Operator Valve

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

WARNING: AVERTISSEMENT. LP & HIGH ALTITUDE LP CONVERSION KIT FOR INSTALLATIONS IN the United STATES (0-10,000 Ft)

INSTALLATION INSTRUCTIONS

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

VR8345M Universal Electronic Ignition Gas Control

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

INSTRUCTION MANUAL. Gas Salamander

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Transcription:

Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36G/J22, 36G/J23, 36G/J24 and 36G/J52 combination gas valves are designed for direct spark ignition (DSI) and hot surface ignition (HSI) system applications. These valves are equipped with redundant and main solenoid valves that control gas fl ow to the main burners, a pressure regulator and a two-position on/off switch for regulation and electrical shut-off of the solenoid valves. The 36G/J23, 36G/J24 and 36G/J52 are also equipped with a slow-opening pressure regulator for softer lighting characteristics. 36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve INSTALLATION INSTRUCTIONS 36G 36J Type of Gas: Natural gas LP gas (use conversion kit) Pressure Setting: Nat. Gas 2.5 to 5.0" W.C. LP Gas 7.0 to 12.0"W.C. Ambient Temperature: -40 to 175 F Pressure Rating: 14" W.C. (1/2 PSI) max. Voltage: 24 VAC Frequency: 50/60 Hz Current:.360 amps CONTENTS Description... 1 Specifications... 1 Precautions... 2 Installation... 3 System Wiring Adjustment... 4 Pressure Adjustment Lighting Instructions... 5 Notes... 6 SPECIFICATIONS Mounting Positions: Multipoise Control may be mounted in any position. Pipe Sizes Available (inches) 1/2" x 1/2" NPT any combination PIPE SIZES/CAPACITIES Capacity (BTU/hr) at 1 pressure drop across valve AGA Std. Nat. Gas (1,000 BTU/cu. ft.) 140,000 LP Gas (2,500 BTU/cu. ft.) 226,800 Parts and Accessories: F92-0656 - LP to Natural Gas Conversion Kit for use on Single Stage 36C, D, E, F, G, H, J valves. Regulation range 2.5" to 5.0" W.C. F92-0659 - Natural to Regulated LP Gas conversion Kit for use on Single Stage 36C, D, E, F, G, H, J valves. Regulation range 7.0" to 12.0" W.C. F92-1003 - Adapter Kit for the 36G Gas Valves. Kit includes: Connector (5/16" to 1/4" hose barb), tube (5/16" O.D.) and Hex Wrench (3/32"). www.white-rodgers.com www.emersonclimate.com PART NO. 37-6159G Replaces 37-6159F 1023

PRECAUTIONS DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS.! WARNING If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. 1. Failure to turn off electric or main gas supply to heating system could cause personal injury and/or property damage by shock, gas suffocation, fire, and/or explosion. 2. Do not use this control on circuits exceeding specified voltage. Higher voltage will damage the control and may cause shock or fire hazard. 3. NEVER USE FLAME OR ANY KIND OF SPARK TO CHECK FOR GAS LEAKS COULD CAUSE FIRE AND/OR EXPLOSION. 4. Do not use a control set for natural gas with LP gas, or a control set for LP gas with natural gas. Personal injury and/or property damage, gas suffocation, fire, and/or explosion may result.! CAUTION 1. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring can cause equipment damage, property damage, and/or personal injury. 2. This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.). 2

INSTALLATION 1. Turn off electrical power to the system at the fuse box or circuit breaker. Also turn off the main gas supply. 2. If replacing an existing valve, disconnect all plumbing and electrical connections from the old control. 3. The control may be installed in any position. The arrow on the bottom plate indicates the direction of inlet gas fl ow. 4. You should use new pipe that is properly chamfered, reamed, and free of burrs and chips. If you are using old pipe, be sure it is clean and free of rust, scale, burrs, chips, and old pipe joint compound. 5. Apply pipe joint compound (pipe dope) that is approved for all gases, only to the male threads of the pipe joints. DO NOT apply compound to the fi rst two threads (see fi g. 2 for typical piping connections). 6. If you are using a vise or open-end wrench to hold the valve while installing piping, do not tighten excessively, as this may damage the valve (Torque: 375 in-lb maximum). Do not cross-thread during installation as this may damage the valve. 7. See SYSTEM WIRING when making electrical connections. After all gas and electrical connections are completed, turn gas on and check for gas leaks with leak detection solution or soap suds. Bubbles forming indicate a leak. SHUT OFF GAS AND FIX ALL LEAKS IMMEDIATELY. SYSTEM WIRING REFER TO AND FOLLOW THE APPLIANCE MANU- FACTURER S WIRING DIAGRAM. REFER TO FIG. 1 FOR TERMINAL IDENTIFICATION. NOTE All wiring should be installed in accordance with local and national electrical codes and ordinances. Always check that the electrical power supply used agrees with the voltage and frequency shown on the gas control. Inlet Pressure Boss (opt.) Outlet Pressure Boss Terminals 24 VAC Input (.250" terminal) Electric ON/OFF Switch On/Off Switch Vent Main & Redundant Adjust 24 VAC Input (.250" terminal) Figure 1. Gas valve wiring diagram NOTE All piping must comply with local codes, ordinances, and/or national fuel gas codes. NOTE: A MANUAL SHUTOFF VALVE MUST BE INSTALLED WITHIN 6 FEET OF THE EQUIPMENT NOTE: ALWAYS INCLUDE A DRIP LEG IN PIPING Horizontal Drop Gas Valve Riser Horizontal Drop 3 in. minimum Gas Valve 3 in. minimum Riser 3 in. minimum Gas Valve Piped Gas Supply Piped Gas Supply Tubing Gas Supply Figure 2. Typical gas valve piping 3

ADJUSTMENT PRESSURE REGULATOR ADJUSTMENT Controls are shipped from the factory with the regulator set as specifi ed on the control label. Consult the appliance rating plate to ensure burner manifold pressure is as specifi ed. If any other outlet pressure is required, follow instructions below. Outlet Pressure Adjustment Range: Nat Gas 2.5" - 5" LP Gas 7.0" - 12" NOTE Valves cannot be adjusted outside these ranges for the specifi ed gas type. 36G/36J Pressure Testing Ports. (See Figure 3) Always adjust regulator to provide the correct pressure according to the original equipment manufacturer's specifications listed on the appliance rating plate. Replace regulator cover screw and tighten securely. Check for Leaks: Using a leak detection solution or soap suds, check for leaks at pressure boss screw or pressure tap plug. Bubbles forming indicate a leak. SHUT OFF GAS AND FIX ALL LEAKS IMMEDIATELY. Outlet Pressure Adjust Tower Inlet Pressure Tap Boss Valve Inlet Outlet Pressure Adjust Tower Model 36J22-214 36G24-214/ 36J24-214 36G54-214/ 36J54-214 36G55-214/ 36J55-214 36J24-614 36J55-614 Testing and Inlet/Outlet Pressure Adjustment 5/16" O.D. Pressure Tap Bosses with 3/32" Hex No need for separate fi tting to check pressure Plugged 1/8" NPT Threaded Pressure Taps Outlet Pressure Tap Boss Pressure Tap Boss Style Valve Inlet 1/8 NPT Inlet Pressure Tap Plugged 1/8 NPT Thread Tap Style Figure 3 Pressure port and regulator adjust locations 5/16 Hose 1/8 NPT Outlet Pressure Tap Turn off all electrical power to the system to connect manometer hoses. For models with Pressure Tap Bosses, turn the pressure test screw (3/32" Hex) in the center of the boss not more than one turn counterclockwise. Attach a 5/16" hose and manometer over the tapered outlet pressure boss on the valve (see fi gure 4). If regulator needs to be adjusted, please see instructions below. After testing pressure or adjusting the regulator, turn off all electrical power to the system, remove manometer hoses, turn outlet test screw (3/32" Hex) clockwise to seal pressure port. Tighten to 7 in-lb minimum. Turn on system power. For models with 1/8" NPT threaded taps, the outlet pressure tap plug will need to be removed and a separate hose fi tting installed. If regulator needs to be adjusted, please see instructions below. After testing pressure or adjusting the regulator, turn off all electrical power to the system, remove manometer hoses, remove hose fi tting and re-install plug. Tighten to 60 in-lb max. Turn on system power. To Adjust : Energize the valve. Remove regulator cover screw. Turn regulator adjust screw clockwise ( ) to increase pressure, or counterclockwise ( ) to decrease pressure (see fig. 5). 4 Figure 4 Hose on pressure tap boss Cover Screw Plastic Adjust Screw Spring Outlet Pressure Tap Boss Figure 5 Hose on Outlet Pressure Tap Boss

FOR YOUR SAFETY READ BEFORE OPERATING LIGHTING INSTRUCTIONS! WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the fl oor because some gas is heavier than air and will settle on the floor. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to move the gas control switch. Never use tools. If the switch will not move by hand, don t try to repair it, call a qualifi ed service technician. Force or attempted repair may result in a fi re or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. OPERATING INSTRUCTIONS 1. STOP! Read the safety information above on this label. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5. Remove control access panel. 6. Wait fi ve (5) minutes to clear out any gas. If you then smell gas, STOP! Follow B in the safety information above on this label. If you don t smell gas, go to the next step. 7. Push gas control switch to ON. NOTE: Do not force. 8. Replace control access panel. 9. Turn on all electric power to the appliance. 10. Set thermostat to desired setting. 11. If the appliance will not operate, follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier. TO TURN OFF GAS TO APPLIANCE 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Remove control access panel. 4. Push gas control switch to OFF. Do not force. 5. Replace control access panel. 5