L-708 / L-708LD Bore Alignment System

Similar documents
METROLOGY LAB. I DEVICES BASED ON VERNIER SCALE

OD plug gauge. for bores and internal profiles from dia. 2,5 mm. OD plug gauge in open design. Special designs Accessories. OD plug gauge for various

Windar Photonics Wind Sensor. Great at Control

PRC CO ² -LASER PRESENTATION

Installation, Alignment, and Tensioning of a Silent Chain Drive

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Microscopy Cryogenic WORKSTATION. Performance by Design

SAFETY SUMMARY.2 CHAPTER I - INTRODUCTION.5 CHAPTER II - OPERATING INSTRUCTIONS.12 CHAPTER III - CALCULATING OFFSET FOR SIGHT ALIGNMENT.

Instructions for using the PRECISION DIGITAL PITCH GAUGE 2008, Precision Analytical Instruments, Inc. Congratulations!

Laser-Induced Bubbles in Glycerol-Water Mixtures

E-trike Li Assembly Guide

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Sprocket Selection Guidelines

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

MURPHY S LAW OF BEARINGS AND SHAFT ALIGNMENTS. PRESENTATION BY DANY LESSARD, MSc

2 Field Practices & Measurements

Job Sheet 1 Blade Aerodynamics

DX2/DXX Operating Instructions

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL.

BIT User Manual. 1. About this manual. 2. Know your BIT 1.1. WARNING System Components

Right-Angle Tube Roller Model

The Criticality of Cooling

Rolled Rotary Ball Screw

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

BRONZE BUSHING REPLACEMENT PROCEDURE DN345 & NL450C

Subsonic Wind Tunnel 300 mm

GALLIUM PRO : ASSEMBLY GUIDE

QUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift

OWNER S MANUAL READ THIS MANUAL BEFORE USING YOUR NEW AIRGUN

UTEX INDUSTRIES, INC.

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Research articles A laser alignment system for boat assembly

HTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT

AutoDrill s OUTSTANDING FEATURES

A Low Cost Digital Angle Gage, version 3

Vertical Wind Energy Engineering Design and Evaluation of a Twisted Savonius Wind Turbine

159 mm 154 mm. Subject to changes 10/2012

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Premium Auto Feed System. Products and Solutions for Assembly

Precision Rotary Ball Screw

product manual H-1200 & H-1250 Universal and Portable Penetrometers

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Rocky Mountain Element Technical Manual. Rev B

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

GALLIUM PRO: ASSEMBLY GUIDE

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

Everest XLG3 VideoProbe

9A5N Solid State CW Paddle

Rocky Mountain Instinct / Pipeline Alloy Frame Assembly Guide. Date: April 7, 2017

Instrumentation & Data Acquisition Systems

Level MEASUREMENT 1/2016

ST Shimano Total Integration. Technical Service Instructions. General Safety Information SI-6CT0B

Specifications Testing & Adjusting Disassembly & Assembly

EFFECTIVE & RELIABLE INSPECTION OF FIN-FAN COOLER TUBES

Rock. ky Altit. ude. Rev B

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

deltaflowc deltaflowc Venturi or Probe

FLUORESCENCE DETERMINATION OF OXYGEN

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

VACGEN. Vacuum Components. Product Overview

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

High Precision Gauge Pressure Indicators

PAPR Flow Tester. instructions. part no WARNING

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Bull s-eye Levels and Screw-On Levels

IAI WARNING! INSTRUCTION MANUAL TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTION MANUAL. ORIGINAL INSTRUCTIONS

Gas Measurement Fundamentals Certification. Curriculum

Verdi G-Series Family

The All New DIAMOND & DIAMOND BT

MASTER TRUING STAND TS-3. Optional Dial indicator set with brackets Dial indicator bracket set only

Vortex Meters for Liquids, Gas, and Steam

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

OP CHECKLIST FOR 1D CONSOLIDATION LABORATORY TEST

TEST PROTOCOL VERIFICATION OF THE BEHAVIOUR OF A MECHANICAL COMPRESSION COUPLING DURING SETTLEMENT

OUTER RACE SHIM SPACERS METRIC OUTER RACE SHIM SPACERS. All Dimensions in Millimeters. Material:300 Series Stainless Steel

GALLIUM: ASSEMBLY GUIDE

GALLIUM CS 281A: ASSEMBLY GUIDE. Revision Valid for MY2019 Gallium CS

How to specify a product. Process Sensors and Mechanical Instruments

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

Applications. Features AWWA ULTRASONIC WATER METER

Rudder Bearing Systems. Durable, water-tight and abrasion-resistant bearing products that eliminate metal-on-metal contact.

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

Columbus Instruments

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

Jet Stream 500 Instruction Manual

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

Item 404 Driving Piling

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

Dorsey Standard Bore Gages

Transcription:

L-708 / L-708LD Bore Alignment System Aligning Bores is Now Faster and Easier Than Ever Geometric Alignment Laser Systems

L-708 / L-708LD Laser Bore Alignment System The Leader in Laser Bore Alignment Technology Hamar Laser manufactures the most accurate, versatile and portable bore alignment laser system available: The L-708 Standard and L-708LD Long Distance Bore Lasers. Data taking targets include: selfcentering, see-through, 2-axis and 4-axis targets with hand-held readouts, and Windows-based software to display and analyze alignment data in real time. Bore applications include: Engine Blocks Compressor Bores Shaft Bearing Bores Stern Tubes Plus many more Results 3x Faster Than Optical Bore Scopes or Tight Wire With the L-708 / L-708LD, alignment of bores is fast and easy: Setup takes 15 to 20 minutes, and overall alignments are done up to 3x faster than with optical bore scopes or tight wire. Because alignment data is real time, misaligned bores can be brought into tolerance very quickly. After setup, a 10' (3 M) long bore can be measured for straightness every foot (300 mm) in under 5 minutes! Self-Centering Target Adapters Reduces Setup time by 50% With conventional bore alignment methods, the measuring device is typically mounted outside the bores, and targets are used in reference bores to align the measurement system a very cumbersome pro - cess that can easily take an hour, or more. With Hamar Laser's patented, self-centering target adapter technology, the setup process is simple: Use the A-514GS or A-514GL Leg Setting Gage to set the legs to the desired diameter. Then the laser and target are mounted directly into the reference bores, reducing setup time to just minutes. More Accurate and Repeatable Measurements Than Optics With optics, the measurement process can be more of an art than a science, since one operator will see a different set of values than another. The L-708 systems use sophisticated electronic sensors to detect the laser and thus offer greater accuracy and repeatability. Bores can be aligned to.0006" (0.015 mm) and the results are repeatable to.0002" (.005 mm). For high accuracy bore applications, the laser should be mounted externally, using the L-111 Laser Stand with the L-102 Beam Trans - lator which can produce accuracies down to.0002" (0.005 mm). Extend Component Life, Reduce Downtime Misaligned bearing bores will cause premature failures, requiring frequent replacement, more downtime, and higher maintenance costs. Proper and more accurate alignment helps components to last longer and prevent big problems before they occur. Key Features: Adaptable to most bore applications Fast, easy setup using simple self-centering adapters Setup and start capturing alignment data in under 20 minutes Check alignment for bore diameters from 3.75" (95 mm) to 40"+ (1 M) Adjustable legs will fit a large range of bore diameters Leg Setting Gage centers adapters to.0003" (0.008 mm) Readouts update in real time as the bore is adjusted Choice of standard LED readout, or add a second readout to transmit readings wirelessly up to 200' (61 M) L-708 Operational Range: 100' (30.5 M) L-708LD Operational Range: 200' (61 M) Durable and rugged design Hamar s patented, self-centering A-514 Target Adapters speed the alignment process, and use adjustable legs for different sized bores.

Features Designed With Versatility in Mind Self-Centering Adapters The Key to Speed The A-512 Target and A-514 Adapter Hubs are designed so that the PSD (position sensing detector) is centered axially between the adapter s four feet, two of which are offset axially from the other two feet. This puts the PSD on the pivot point of the adapter and allows the target s angle of incidence to the laser to vary by up to 45 without changing the adapter s centering. To insert the target/adapter into the bore, a weighted handle is attached to the target/adapter and the adapter is tipped forward, which allows it to be inserted into the bore. The weight of the handle forces the target to tip backward and seat the target legs into the bore, centering the adapter/target. Bore8 Software showing plot of bore straightness. Bore Adapter Feet PSD Bore Centerline Centerline of Bore Target and Adapter Self-centering target reduces setup time by 90%! Self-Centering Laser/Adapters Our patented A-514 self-centering laser and target bore adapters accurately and quickly position the laser and target on the bore centerline. The adapters can be centered to the bore to within.0003" (0.008 mm). Adjustable Target Adapter Legs Self-centering laser and target adapters have adjustable legs that allow adapters to be used for dia meters ranging from 3.75" (95 mm) to 40" (1 M). Choose from three bore adapters: A-514A for bores from 3.75" (95 mm) to 6.75" (172 mm), A-514B for bores from 6.5" (165 mm) to 17.5" (445 mm) and the A-514C for bores from 17" (432 mm) to 40" (1 M). Long Range, High Accuracy The L-708LD can be used out to 200' (61 M). Laser beam is straight to 0.0008 mm/m. Precise Angular Adjustment Precision angular adjustments provide angular pointing control of the laser beam so it can be tilted with a resolution of.0007" in 100' (0.018 mm in 30.5 M). The L-708LD laser has an angular adjustment resolution of.0014" in 200' (0.036 mm in 61 M). Large Bore, Half Bore and See-Through Applications For bores over 1 meter, half-bores, or where bore surfaces are worn or rough, the T-218 Two-Axis Universal Target and T-225L Large Bore Flange are used. The T-218 has a prism that flips out of the way, allowing the laser beam to pass unobstructed through the target without removing it a useful feature when aligning multiple bores over long distances. For half-bores, the T-218 is used with our A-502A Half-Bore and A-501A Bore Sweep Fixtures. Large-Range Targets For 200-foot measuring range, the L-708LD Long Distance Bore laser requires a larger-diameter laser beam, which requires our large-range bore target, the T-1218 2-Axis Target. It has 20 x 20 mm measuring range and has a hardened, stainless steel body with a 3" (76.2 mm) diameter mounting surface. Use with the T-1225L Bore Adapter to measure bores from 5.75" (146 mm) to 40"+(1 M). Laser Beam Concentric to Mounting OD The L-708 laser beam is concentric to its 1.2498" (31.745 mm) OD mounting surface to 0.0003" (0.008 mm). The face of the laser has powerful magnets to hold the laser in the adapters. Optional Computer Upgrade Data can be collected and displayed in real time with laptop upgrade and Bore8 Soft ware that plots bore misalignment: 1) relative to end bores, 2) relative to two user-defined bores or 3) relative to Best Fit line.

How HLI Bore Alignment Systems Work Two Ways to Mount the Laser 1. Internal Mount This method allows centering to.0006" (0.015 mm). The A-514 Self- Centering Bore Adapters for both laser and target are put on a leg-setting gage to adjust the legs to the desired bore radius. Next the L-708 and A-512 Targets are inserted into their bore adapters. The laser and target assemblies are inserted into the two reference bores where they self-center. Then the laser s angular adjustments are used to set/tilt the laser to zero on the target, establishing the reference bore centerline. The target can be moved (or second target added) to inner bores for alignment checks. Since the alignment data in the readout updates in real time, any errors can be adjusted using the target as a live indicator. Using the A-514 Self-Centering Target Adapters, the L-708 can be mounted in the first reference bore and centered to.0006" (0.015 mm). 2. External Mount For higher accuracy applications, where alignment of the bores (not straightness) is needed, mounting the laser externally is recommended. This method produces a more accurate laser centering to.0002" (0.005 mm). L-706, L-111 Laser Stand, L-102 Beam Translator The L-111 Laser Stand has coarse angular adjustment and the L-102 Beam Translator can move the laser beam up/down and left/right without changing the angle. The L-708 is mounted in the L-111 and the L-102 is attached. The whole assembly is then mounted near the first reference bore. The A-512/A-514 target/adapter is placed in the first bore and the L-102 is adjusted to center the beam to the target. The target is then moved to the far reference bore and the angular adjustments are used to tilt the laser to the center of the target. This process is repeated a few times until the target reads zero at both locations. Measuring Bore Alignment After setup, the A-512 Target is placed in the desired bore for measurement, which takes <10 seconds. The R-1307 2-Axis Readout displays bore misalignment. To align a bore to a centerline, two sets of readings are needed: one in the front and one in the rear of the bore. This aligns the angle of the bore as well as its center to the reference bore centerline. High-Tolerance Bore Alignment For high-tolerance bore applications, the Target Sensor Concentricity Error (TSCE) must be calculated using a procedure called the NORMIN method. The TSCE is calculated by taking two readings, one with the target at the normal (12:00) position and a second with the target inverted (6:00). The second reading is subtracted from the first and the result is divided by two to determine the TSCE. The TSCE can be subtracted from all subsequent bore measurements to produce the true misalignment value. Our Bore8 software can easily calculate TSCE and even automatically remove it from the displayed reading. Checking Bore Straightness on Cylinders up to 25' Long Checking the bore straightness of a long cylinder is a simple procedure. After setting up the laser, the target is inserted into the bore in predetermined increments and the readings are recorded. For long bores, the A-512 Target uses a pole to push the target into each measuring point up to 25' (7.6 M) inside a bore.

Alignment Solutions for Even the Most Difficult Bore Applications Applications Overview Hamar Laser bore systems can handle a wide range of bore alignment and straightness determination and measurement tasks. Even extremely difficult bore alignment challenges, like spherical bearings, can be done easily. If you do not see your application listed, please contact us to discuss your requirements. We will be more than happy to provide a solution that's right for your unique alignment problem. Automotive, Marine & Locomotive Engine Blocks Crankshaft and camshaft line bores Cylinder straightness Manufacturing & Metalworking Boring bar bearing alignment Deep bore straightness checks on parts Workpiece bore to spindle alignment Marine Propeller shaft bearing bores Stern tube alignment Power Generation Steam turbines Gas turbines Plastics Extruder barrel alignment Extruder bore straightness and wear Aerospace Hinge line spherical bearing bores Stern Tube & Propeller Shaft Bearings The L-708 / L-708LD can quickly and easily check stern tube and propeller shaft bearing alignment. It can even check the gearbox shaft's axis of rotation alignment to its bearings, saving loads of time versus a tight wire. It can also be used to set up boring bar bearings for line boring equipment. Engine Block Bore Alignment The L-708 / L-708LD gives automotive and diesel-engine manufacturers a fast, reliable way to measure crankshaft bores for straightness and alignment. Our system decreases inspection times significantly and eliminates the need for expensive gauging. The L-708 / L-708LD is also used for measuring the straightness of engine block cylinder bores. Engine block crankshaft bearing bore alignment. Extruder Barrel Alignment With a 10 minute setup time and simple procedure, extruder barrels can be aligned in less than 1 hour using our L-705 Bore Laser. The adapters can also be used to measure barrel wear. Turbine Alignment Since 1975, our Steam Turbine Alignment System has cut alignment times by 50% and increased accuracy vs. tight wires. With the introduction of the L-705, alignment times have been further reduced. We also offer lasers to check split joint flatness and motor couplings. The L-706 Laser is designed for use over long distances making it suitable for steam turbine alignment applications. Hinge-Line Bearing Alignment Smaller spherical bearings in commercial aircraft hinge-lines are aligned using the L-705 and T-271 2-Axis Virtual Center Target. For larger spherical bearings (2.25" and above) the T-218 Target and T-225X Flange are used. Now extremely difficult alignment tasks can be done in one-tenth the time!

OFF LASER CONT. PULSE 9VDC POWER COARSE ANGLE CENTER Specifications Target and and Bore Adapters L-708 / L-708LD Laser A-512 Target Mounting Surface OD: 1.2498" (31.745 mm). Target sensor concentric to OD to within.0003" (0.008 mm). Mounting surface 303 SS. A-514A Small Bore Target Adapter A-514B Medium Bore Target Adapter For bore diameters from 3.75" (95 mm) to 6.75" (172 mm). For bore diameters from 6.50" (165 mm) to 17.5" (445 mm). A-514C For bore diameters from 17" (431.8 mm) Large Bore to 40" (1 M) Target Adapter A-514G Bore Gage Sets A-514 Adapters legs to correct bore diameter to.0002" (.005 mm). Use A-514GS for A-514A & B Adapters. Use A-514GL for A-514A, B & C Adapters. Size Weight Power Center Angular Adj. Resolution Angular Adj. Range (See line drawings) 1.6 lbs. (0.7 kg.) 9V external battery pack/ac adapter Laser concentric within.0003" (0.008 mm) No adjustment Controlled by two high-pitch adjustment knobs. Coarse:.0006"/ft. (0.05 mm/m) Fine:.000007"/ft. (0.0006 mm/m) Coarse: ± 1.0 (±.21"/ft. or 17.5 mm/m) Fine: ± 0.03 (±.007"/ft. or 0.6 mm/m) Operating L-708: Up to 100' (30.5 M) Distance L-708LD: Up to 200' (61 M) Laser Beam Diameter L-708: < 0.25 in./6.4 mm dia. L-708LD: <0.38" (9.6 mm) dia. Ø3.25 [82.55mm].750 [19.05mm] 2.50 [63.5mm] A-514A Target Adapter Ø5.63 [142.88mm] Beam Straightness Beam Stability Laser Type Laser Wavelength Materials.00001"/ft. (0.0008 mm/m).0001"/hr./ F (0.004 mm/hr./ C).0001"/ft./hr./ F (0.01 mm/m/hr./ C) Diode Laser < 0.9 mw Cw, BRH Class II 635 nanometers Aluminum Flange. All mounting surfaces: 303 SS. Ø3.62 [91.98] 4.58 [116.28] 3.84 [97.54] 1.84 [46.74] Ø1.2498 -.0003 +.0000 [ 31.745 +0.000-0.008 ] V 7 L8 0 CAUTION LASER RADIATION: DO NOT STARE INTO BEAM LESS THAN 1mW CLASS II LASER PRODUCT 635nM H Ø3.00 [76.2] 1.250 [31.75mm] 2.50 [63.5mm] A-514B Target Adapter Ø16.00 [406.4] HAMAR LASER 2.40 [60.96] 3.50 [88.9].68 [17.27] 1.25 [31.75] (APERATURE) Ø2.00 [50.8] Ø1.2498 +.0000 -.0003 [ 31.745 +0.000-0.008 ] 1.25 [31.75] (CELL PLANE) 2.750 [69.85mm] 4.25 [107.95mm] A-514C Target Adapter Hamar Laser Instruments, Inc. 5 Ye Olde Road, Danbury, CT 06810 Phone: 800.826.6185 Fax: 203.730.4611 Int l: +1.203.730.4600 E-mail: sales@hamarlaser.com www.hamarlaser.com U.S. and foreign patented and/or patents pending. Made in the USA. L-705DS.PM5 2011 Hamar Laser Instruments, Inc. (6/11)