Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Similar documents
1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

Verification and validation of computer codes Exercise

Particle Control under Wall Saturation in Long-pulse High-density H-mode Plasmas of JT-60U

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

Transient Analyses In Relief Systems

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

ICONE ASSESSMENT OF THE TRACE REACTOR ANALYSIS CODE AGAINST SELECTED PANDA TRANSIENT DATA

Comparison of MARS-KS to SPACE for counter current flow limitation model

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

WATER HYDRAULIC SYSTEM FOR HIGH SPEED CYLINDER DRIVE

Profile LFR-45 LIFUS5 ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy

Numerical Investigation of Air Bubbles Evolution and Coalescence from Submerged Orifices Based on OpenFOAM

Preliminary Failure Mode and Effect Analysis for CH HCSB TBM

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

The Effects of Non-Condensible Gas on the Critical Pressure Ratio and Critical

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

Steam generator tube rupture analysis using dynamic simulation

RELAP5 Code Study of ROSA/LSTF Experiments on PWR Safety System Using Steam Generator Secondary-Side Depressurization

ON TRANSIENTS IN PUMA

EVALUATION OF TWO-PHASE FLOW MODELS FOR

EXPERIMENTAL SUPPORT OF THE BLEED AND FEED ACCIDENT MANAGEMENT MEASURES FOR VVER-440/213 TYPE REACTORS

HYDROGEN FAST FILLING TO A TYPE IV TANK DEVELOPED FOR MOTORCYCLES

LEAP CO 2 Laboratory CO 2 mixtures test facility

The API states the following about tube rupture for a shell-and-tube heat exchangers:

Experimental Investigation of CCFL in Pressurizer Surge Line with Air-Water

Numerical and Experimental Investigation of the Possibility of Forming the Wake Flow of Large Ships by Using the Vortex Generators

New Findings for the Application of Systems for Explosion- Isolation with Explosion Venting

Mass Split of Two-Phase-Flow

Numerical Simulation for the Internal Flow Analysis of the Linear Compressor with Improved Muffler

MODELING AND SIMULATION OF VALVE COEFFICIENTS AND CAVITATION CHARACTERISTICS IN A BALL VALVE

THERMODYNAMICS, HEAT AND MASS TRANSFER TUTORIAL NO: 1 (SPECIFIC VOLUME, PRESSURE AND TEMPERATURE)

Development of High-speed Gas Dissolution Device

Simulation and Experimentation on the Contact Width of New Metal Gasket for Asbestos Substitution

Applied Fluid Mechanics

Concentration profile of jet gas in the feed injection zone of a FCC riser

44 (0) E:

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

XCFD4NRS. Experiments and CFD Codes Application to Nuclear Reactor Safety. OECD/NEA & International Atomic Energy Agency (IAEA) Workshop

Start-up of the Three-shaft Closed Loop

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Effects of Delayed RCP Trip during SBLOCA in PWR

Design and Safety Document for the Vacuum Windows of the NPDGamma Liquid Hydrogen Target at SNS

A Study of Intermittent Buoyancy Induced Flow Phenomena in CANDU Fuel Channels

Thermodynamics ERT 206 Properties of Pure Substance HANNA ILYANI ZULHAIMI

Loss of Vacuum Experiments on a Superfluid Helium Vessel

MODELLING AND SIMULATION OF FIRETUBE BOILERS WITH ECOSIMPRO: ANALYSIS OF CONTINUOUS AND STAND-BY OPERATION

Special edition paper

Chapter 4, Problem 30.

Relief System Sizing for Runaway Chemical Reactions: A Simple Comprehensive Approach

MASSIVE GAS INJECTION SYSTEMS FOR DISRUPTION MITIGATION ON THE DIII-D TOKAMAK

Study on Marine Propeller Running in Bubbly Flow

EXERCISE 2: THE VACUUM SYSTEM

Research Article Remarks on Consistent Development of Plant Nodalizations: An Example of Application to the ROSA Integral Test Facility

Design and Optimization of Weld Neck Flange for Pressure Vessel

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

An Investigation of Liquid Injection in Refrigeration Screw Compressors

3 1 PRESSURE. This is illustrated in Fig. 3 3.

MODELLING OF FUME EXTRACTORS C. R.

CONDENSATION OF A LARGE-SCALE BUBBLE IN SUBCOOLED LIQUID: EXPERIMENTAL VERIFICATION OF THE SIMMER-III CODE

OPTIMIZATION OF INERT GAS FLOW INSIDE LASER POWDER BED FUSION CHAMBER WITH COMPUTATIONAL FLUID DYNAMICS. Abstract. Introduction

WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

SIMULATION OF ENVIRONMENTAL FLIGHT CONDITIONS

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Summary of Safety and Environmental Assessment of ARIES-AT. David Petti Fusion Safety Program, INEEL

Relief Systems. 11/6/ Fall

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry

Tirpur Area Water Supply Project A Report on Transient Modeling Study

Increasing the productivity of ICP-OES with the Thermo Scientific Qtegra ISDS Software

HYDROGEN RISK ANALYSIS FOR A GENERIC NUCLEAR CONTAINMENT VENTILATION SYSTEM

The Discussion of this exercise covers the following points:

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

The Split of Two-Phase-Flow at Horizontal Side-T-junctions in Unbalanced Pipe Systems for Clean Extinguishing Agents

Computer aided sand wedge shape assessment by using particle simulation

ENGINEERING DESIGN OF CRYOCONDENSATION PUMPS FOR THE DIII-D

CHARACTERISTICS OF LEAK DETECTION BASED ON DIFERENTIAL PRESSURE MEASUREMENT

Heat Transfer Research on a Special Cryogenic Heat Exchanger-a Neutron Moderator Cell (NMC)

Characteristics Prediction of Vane Pump by CFD Analysis

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

PERFORMANCE AND CHARACTERISTICS OF COMPRESSOR/EXPANDER COMBINATION FOR CO 2 CYCLE ABSTRACT

ASSIGNMENT 2 CHE 3473

Reflux Condensation with Various Non-Condensable Gases

MEASUREMENT OF GAS DISCHARGE COEFFICIENT

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER P: REFERENCE OPERATING CONDITION STUDIES (PCC)

Predicting the Suction Gas Superheating in Reciprocating Compressors

Experimental determination of deflagration explosion characteristics of methane air mixture and their verification by advanced numerical simulation

ASSIGNMENT 2 CHE 3473

Example 4 - Airbag. Summary

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

XA TEPSS RELATED PANDA TESTS (ESBWR)

Transcription:

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute (JAERI), Tokai-mura, Ibaraki-ken, Japan e-mail contact of main author: takase@popsvr.tokai.jaeri.go.jp Abstract. An integrated ICE (Ingress-of-Coolant Event) test facility was constructed to demonstrate that the ITER safety design approach and design parameters for the ICE events are adequate. Major objectives of the integrated ICE test facility are: to estimate the performance of an integrated pressure suppression system; to obtain the validation data for safety analysis codes; and to clarify the effects of two-phase pressure drop at a divertor and the direct-contact condensation in a suppression tank. A scaling factor between the test facility and ITER-FEAT is around 1/1. The integrated ICE test facility simulates the ITER pressure suppression system and mainly consists of a plasma chamber, vacuum vessel, simulated divertor, relief pipe and suppression tank. From the experimental results it was found quantitatively that the ITER pressure suppression system is very effective to reduce the pressurization due to the ICE event. Furthermore, it was confirmed that the analytical results of the TRAC-PF1 code can simulatet the experimental results with high accuracy. 1. Introduction If cooling tubes installed into plasma-facing components (PFCs) in a Tokamak vacuum vessel are broken, water under high temperature and pressure in the cooling tubes will be discharged into the vacuum vessel (VV). Then, the discharged water will impinge on the hot surface of the PFCs and evaporate. As a result, the VV will be filled with vapor and the pressure in the VV will increase rapidly. This is called an Ingress-of-Coolant Event (ICE). Takase, et al. [1] investigated physical phenomena during the ICE event using a preliminary ICE apparatus and led controlling factors on the pressure rise. Since the preliminary ICE apparatus did not simulate the ITER configuration, it was difficult to estimate the ITER safety at the ICE event from the results of the preliminary ICE experiments. However, the quantity of the ICE behavior and the verification of the safety analysis codes are very important for the safety design of fusion reactors. Then, an integrated ICE test facility was planned and constructed referring to the ITER pressure suppression system, and the adequacy of the ITER pressure suppression system was investigated quantitatively. Furthermore, numerical analyses with the TRAC-PF1 code, which is a safety analysis code for light water reactors, were performed and the prediction accuracy of the TRAC-PF1 code was verified. 2. Experimental Study 2.1 Pressure Suppression System in ITER Figure 1 shows a concept of the pressure suppression system in ITER-FDR [2]. The water injected from the cooling tubes into the PFC flows through the divertor slits to the bottom of the VV and the accumulated water in the VV goes through a relief pipe to a suppression tank (ST). At this time a great amount of vapor generates due to the flashing under vacuum and boiling heat transfer from the plasma-facing surfaces, and then, the pressure inside the PFC and VV increases. Because of the pressurization a couple of rapture disks which are settled at the relief pipe are broken and the water under high temperature and vapor flow into the ST. The ST initially holds water under low temperature and pressure (around 25 C and 2 Pa). Therefore, water under high temperature and vapor can be cooled down and condensed inside

Vacuum vessel injector Pressure rise Plasma chamber injection PFC From a boiler Simulated slit Vacuum vessel Slits Rapture disks Magnetic valve FIG. 1 ITER pressure suppression system. FIG. 2 Outline of an integrated ICE test facility. the ST, and consequently, the pressure in the ITER can be decreased. In the current design of the pressure suppression system in ITER-FEAT [], a few relief pipes are installed at the upper region of the VV and connected to the ST and a drain tank is settled at the bottom of the VV with a drain pipe. This new design concept on the pressure suppression system using the ST and drain tank was considered to enhance the condensation performance in the ST by separating the vapor and water from the mixture at the ICE events. 2.2 Integrated ICE Test Facility Figure 2 shows a schematic drawing of an integrated ICE test facility. The integrated ICE test facility simulates the ITER components with a small-scale model of 1/1 and mainly consists of a plasma chamber (PC), divertor, VV, relief pipe, ST, water injection nozzle and boiler. The PC simulates the volume of PFC in ITER and has a volume of.6 m. The VV simulates a part of VV in ITER and has a volume of.4 m. The divertor simulates the divertor cassette section in ITER and its dimensions are a width of 12 mm, height of 162 mm and length of 12 mm. A plate with multiple slits is installed into the divertor to simulate the ITER evacuation slits. The slit dimensions are 5 mm in width, 8 mm in length, 15 mm in depth, 1 mm in pitch and 12 in total number, and those values are determined based on the current ITER design values. Compensation heaters are set to the outside of the PC, divertor and VV to control the outer temperature.

The ST has a volume of.9 m and the initial water volume is less than.5 m. A maximum diameter of the water injection nozzle is 1 mm and three water injection nozzles were set up to simulate the multiple pipe rupture conditions in ITER. in the boiler is pressurized by nitrogen gas to maximum 4 MPa and heated by the heaters up to maximum 25 C. The water pressure in the boiler during the injection of water is controlled by nitrogen gas to keep at a constant value because the injected water flow rates from the water injection nozzles do not change with time. 2. Experimental Conditions Three kinds of the integrated ICE experiments were carried out: Case 1, Case 2 and Case. In Case 1 the injection time of water was 1 s and the ST is not available. In Case 2 it was also 1 s but the ST is available. In Case it was s and the ST is available. The effectiveness of the ST to reduce the pressure rise during the ICE event was evaluated from the results of Case 1 and 2. Furthermore, the effect of the injection time on the pressurization was investigated from the results of Case 2 and. Common experimental conditions for each test case were: water temperature of 15 C; water pressure of 2 MPa; wall temperature of 2 C; initial pressure inside the test facility less than 1 Pa; water nozzle diameter of 1 mm; water nozzle number of. In addition, the initial pressure inside the ST was set to around 2 Pa, and therefore, the initial temperature inside the ST was the saturation temperature which is determined by the pressure. In Case2 and in which the ST is available, a magnetic valve at the relief pipe is opened when the pressure in the PC reached.15 MPa after the injection of water, and then, the ST is connected to the bottom of the VV through the relief pipe.. Analytical Study The TRAC is an advanced, best-estimate computer program to calculate the transient behavior of a pressurized water reactor (PWR). The TRAC-PF1 code [4], which is one of a series of TRAC codes, uses a two-phase two-fluid model for the incompressible fluid flow. Detailed governing equations and empirical correlations for the two-phase flow analysis are shown in Ref.[5]. A nodalization diagram of the analytical model is shown in Fig.. Here, the PC, VV, divertor, ST and boiler were modeled using a VESSEL component in the TRAC code, and similarly, the relief pipe and water injection nozzle were modeled using PIPE and VALVE components, respectively. In addition, gas and water piping at the boiler was modeled with a PIPE component and a pressure controller was modeled with a BREAK component. The boiler maintains at constant pressure by the BREAK component to simulate the experimental condition. In the present numerical analysis a three dimensional model was chosen for the VESSEL component. The mesh division numbers in the radial, circumferential and axial directions in the VESSEL component are 8x1x1 at the PC, 24x2x1 at the divertor, 4x5x1 at the VV, xx1 at the boiler and 1x4x1 at the ST. Each mesh division number was decided based on the results of sensitivity calculations. The initial pressure in the present numerical study was set to 1 kpa based on the assumption of continuity of the fluid. Analytical conditions are the same as the experimental conditions mentioned in Section 2..

Gas piping Pressure controller A 21 mm injection nozzles f mm Plasma chamber (.5 m ) (.6 m ) Boiler (.6 m ) f 5 mm piping Cross section A-A 1262 mm A Vacuum vessel (.4 m ) 172 mm ( f 5 mm, 2 mm) Magnet valve (.9 m ) (.5 m ) FIG. Nodalization diagram of the analytical model with TRAC-PF1 code. 4. Results and Discussion Figure 4 shows the pressure transients inside the PC and is the result of Case 1. Here, the solid and dashed lines indicate the experimental and analytical results. The pressure increases due to flashing just after the injection of water. When the injection of water ends, the pressure increases gradually up to the saturation pressure determined by temperature. The analytical result agrees well with the experimental result up to 8 s and is slightly overestimated after 8 s. The difference between both results after 8 s depends on the overestimation of the supposed heat transfer rates from the component walls in the analytical model. Figure 5 shows the pressure transients inside the PC and is the result of Case 2. Here, the solid and dashed lines indicate the experimental and analytical results. As soon as the injection of water completes, the pressure decreases drastically and reaches less than atmospheric pressure because of the condensation effect with the ST. The predicted maximum pressure is in good agreement with the maximum pressure obtained by the experiment. An error between both maximum pressures was only.4%. It was verified from the present results that the ST system is very effective to reduce the pressure rise at the ICE events and the maximum pressure in the PC during the injection of water can be predicted numerically with sufficient accuracy. Figure 6 shows the pressure transients inside the PC and is the result of Case. Here, the solid and dashed lines indicate the experimental and analytical results. In comparison with Fig. 5, the time which the pressure represents the highest value is lengthened because the injection time of water is longer. The maximum pressure value at the PC during the injection of water when the ST is available depends on the average temperature in the PC which is determined by the water temperature and wall temperature inside the PC. The analytical result showed underestimation at the early stage with the experimental result and overestimation at the final stage during the injection of water, however, the analyzed maximum pressure was in good agreement with the experimental result within an error of 1.5%.

1 1 8 8 is used. 2 is not used. 2 6 9 12 15 18 FIG. 4 Pressure transients in the PC at Case 1. 6 9 12 15 18 FIG. 5 Pressure transients in the PC at Case 2. 5. Conclusions From the results of the integrated ICE experiments, the pressure rise characteristics in ITER during the ICE event were clarified quantitatively, and then, the analytical results of the TRAC- PF1 code were verified with the experimental results. It was concluded from the present study that the ITER pressure suppression system is very effective to reduce the pressurization due to the ingress of water and the analytical results with the TRAC-PF1 code can simulate the experimental results with high accuracy. References 1 8 is used. 2 6 9 12 15 18 FIG. 6 Pressure transients in the PC at Case. [1] TAKASE, K., et al., "Possibility of Volume Reduction of Blowdown Tank in Fusion Reactor Safety System", Fusion Technology, 4 (1998) 64-644. [2] IAEA, "Technical Basis for the ITER Final Design Report, Cost Review and Safety Analysis (FDR)", ITER Documentation Series, No. 14, IAEA, Vienna, (1999). [] IAEA, "Technical Basis for the ITER FEAT Outline Design", to be published as ITER Documentation Series by IAEA. [4] LILES, D. R., "TRAC-PF1/MOD1: An Advanced Best-Estimate Computer Program for Pressurized reactor Thermal-Hydraulic Analysis", NUREG/CR-858 (LA-1157-MS), (1986). [5] LILES, D. R., at al., "TRAC-PF1/MOD1 Correlations and Models", NUREG/CR-569 (LA-1128-MS R4), (1988).