! Warning, refer to accompanying documents.

Similar documents
Operator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)

DPC-30 DPC-100. Reference Manual

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Model 106 DPI "Micro-switch" Installation and Operating Instructions

WIKA INSTRUMENT CORPORATION

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

User s Guide Temperature Sensor Converter TSC-599

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

SC505 Sof Care Inflator. Operating Instructions and Service Manual

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Advanced Test Equipment Rentals ATEC (2832)

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Department of Electrical Engineering & Computer Science. Electrical Safety. for Staff and Students in EECS Instructional Laboratories

6 digital caliper with case

USER S GUIDE AUTOTUNE SERIES HIGH INTENSITY ULTRASONIC PROCESSOR Watt Model TABLE OF CONTENTS

Norrsken Family Booklet

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Operation Manual. O2 Quickstick. Oxygen Analyzer

2000 lb manual winch

PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

Model Visit our website at:

Installation and Operation Manual

R E D I C O N T R O L S

MODEL CALIBRATION GAS DELIVERY SYSTEM

SAFETY & OPERATING INSTRUCTIONS

TELEDYNE HASTINGS INSTRUMENTS MODEL 40 POWER SUPPLY INSTRUCTION MANUAL

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

Ocean Technology Systems ComBox

Mini Pod Press. #78H-M2 Mini Pod Press Manual-R1

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

GRI-1300/1350Li. User Manual

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

9101 Zero Point Dry-Well

Digital Melting Point Apparatus

Service Instructions. Syntron Jogger Model: Mini-CheckMate TM

Nuclear Associates

WARNING NOTES TABLE OF CONTENTS

Research Grade Blood Pressure Transducer User's Manual

Portable Compressed CO 2 Regulator

New AQF Filter Polymer Filtration System

Safe Schools: A Health and Safety Check

RAM 4021 Operation Manual

Harvard Trip Balance BA710. Impact Test Equipment Ltd & User Guide. User Guide

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

D I G I T A L C L A M

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Operator: Save these instructions for future use!

USER MANUAL

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

8675/8677/8678 OWNER S MANUAL

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

User Manual GRI- 1500Li

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Storage Shelving. User Manual [Revision 3.0 May 2017]

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL RLD10

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-100. Club Volleyball Gear WARNING

Service Instructions. Syntron Control Model: CSCR-1-B (115V)

J Air and Water Kit Instructions Part# 02584

MODEL GT820 OXYGEN SENSOR

453 Series Steam Heated Vaporizing Regulator

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

INSTALLATION AND OPERATING INSTRUCTIONS

O P E R A T O R S M A N U A O P E R A T O R S M A N U A L L

TV-114 TV-114-A Wind Speed Sensor User s Manual

Owner s Manual & Safety Instructions

Model ASSEMBLY and OPERATING INSTRUCTIONS

92831 TEL: (714) FAX:

OWNER S MANUAL. Page: 1 of 8

Operator: Save these instructions for future use!

Ground Fault Circuit Interrupter(GFCI) Policy

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Temperature gauge Installation Guide

Installation, Operation & Maintenance Manual

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

PBT1100 POWER BANDING TOOL

Instruction Manual BA90 Precision Barometer

MODEL 100 NITROGEN INFLATION CART

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL


Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY

Definitions found in several locations:

TrekMill USER'S MANUAL MM5050

Heavy Duty Dissolved Oxygen Meter

Parts and Owners Manual

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

GAS FUEL VALVE FORM AGV5 OM 8-03

Transcription:

About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument in compliance with its original advertised specifications. Notes and Safety Information This Operator s Manual contains warning symbols which alert the user to check for hazardous conditions. These appear throughout this manual where applicable, and are defined below. To ensure the safety of operating performance of this instrument, these instructions must be adhered to.! Warning, refer to accompanying documents. Caution, risk of electric shock. This instrument is designed to prevent accidental shock to the operator when properly used. However, no engineering design can render safe an instrument which is used carelessly. Therefore, this manual must be read carefully and completely before making any measurements. Failure to follow directions can result in a serious or fatal accident. 2! Technical Assistance SIMPSON ELECTRIC COMPANY offers assistance Monday through Friday 7:30 am to 5:00 pm Central Time. To receive assistance contact Technical Support or Customer Service at (847) 697-2260. Internet: http://www.simpsonelectric.com Warranty and Returns SIMPSON ELECTRIC COMPANY warrants each instrument and other articles manufactured by it to be free from defects in material and workmanship under normal use and service, its obligation under this warranty being limited to making good at its factory or other article of equipment which shall within one (1) year after delivery of such instrument or other article of equipment to the original purchaser be returned intact to it, or to one of its authorized service centers, with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been thus defective; this warranty being expressly in lieu of all other warranties expressed or implied and of all other obligations or liabilities on its part, and SIMPSON ELECTRIC COMPANY neither assumes nor authorizes any other persons to assume for it any other liability in connection with the sales of its products. This Instrument is designed to prevent accidental shock to the operator when properly used. However, no engineering design can render safe an instrument which is used carelessly. Therefore, this manual must be read carefully and completely before making any measurements. Failure to follow directions can result in serious or fatal accident.

SHOCK HAZARD: As defined in American National Standard, C39.5, Safety Requirements for Electrical & Electronic Measuring & Controlling Instrumentation, a shock hazard shall be considered to exist at any part involving a potential in excess of 30 volts RMS (sine wave) or 42.4 volts DC or peak and where a leakage current from that part to ground exceeds 0.5 milliampere, when measured with an appropriate measuring instrument defined in Section 11.6.1 of ANSI C39.5. NOTE: The proper measuring instrument for the measurement of leakage current consists essentially of a network of a 1500 ohm non-inductive resistor shunted by a 0.15 microfarad capacitor connected between the terminals of the measuring instrument. The leakage current is that portion of the current that flows through the resistor. The Simpson Model 229-Series 2 AC Leakage Current Tester meets the ANSI C39.5 requirements for the measurement of AC leakage current and can be used for this purpose. To measure DC Leakage current, connect a 1500 ohm non-inductive resistor in series with a Simpson 0-500 DC microammeter and use this as the measuring instrument. 3

Contents 1. INTRODUCTION... 5 1.1 Items And Accessories... 5 1.2 Safety Considerations... 5 1.3 Technical Data... 5 2. INSTALLATION... 6 2.1 Unpacking And Inspection... 6 2.2 Warranty... 6 2.3 Shipping... 6 2.4 Operation Instructions... 6 3. CONTROLS, CONNECTORS & INDICATORS... 7 3.1 Front Panel... 7 4. OPERATION... 8 4.1 Safety Precautions... 8 4.2 Test Probes... 8 4.3 Preparation For Use... 8 4.4 Temperature Measurements... 9 5. SERVICING INSTRUCTIONS... 10 5.1 Battery Replacement... 10 5.2 Calibration... 10 5.3 Care... 10 5.4 Replacement Parts... 10 4

1. INTRODUCTION The Simpson 385-3L V2 Temperature Tester, (hereafter referred to as the 385-3L or the Instrument) measures temperatures from -50 o F to +70 o F (-45 o C to +21 o C). This Instrument is supplied with one 15 foot general purpose thermistor lead and will accommodate two additional leads so that readings at three different locations can be taken in quick succession. Accuracy is within 2 o F or C for any scale reading. Near the center of the scale, accuracy is within 1. 1.1 Items And Accessories All items and accessories required for the operation of the 385-3L are furnished with each Instrument and listed in Table 1-2. 1.2 Safety Considerations This Operator s Manual contains cautions and warnings alerting the user to hazardous operating and servicing conditions. This information is flagged by CAUTION or WARNING symbols throughout this publication and is defined on the inside front cover of this manual under SAFETY SYMBOLS. Adhere to these instructions in order to ensure the safety of operating and servicing personnel and to retain the operating conditions of the Instrument. 1.3 Technical Data Table 1-1 lists the technical data for the Model 385-3L. Table 1-1. Technical Data Range: -50 o F to +70 o F -45 o C to +21 o C Accuracy: 1 o F/C @ Center Scale 2 o F/C @ Either End Table 1-2. Items and Accessories Furnished with this Instrument Description Part No. Operator s Manual 6-114985 15 Foot Lead and Thermistor 00010 385-3L V2 Temperature Tester D-12420 Table 1-3. Additional Accessories Description Part No. Surface Temperature Probe 00790 Free Air Temperature Probe 00789 30 Foot Lead and Thermistor 00216 50 Foot Lead and Thermistor 00415 100 Foot Lead and Thermistor 00416 150 Foot Lead and Thermistor 00417 Ever-Redy Leather Carrying Case 08073 5

2. INSTALLATION This section contains instructions for the installation and shipping of the 385-3L. Included are unpacking and inspection procedures, warranty, shipping, and operation instructions. 2.1 Unpacking And Inspection Examine the shipping carton for sign of damage before unpacking. Unpack and inspect the Instrument for possible damage in shipment. If damage is noted, contact the carrier and supplier before using the Instrument. Check that all furnished items and accessories are included (Table 1-2). Save the shipping carton and packing materials for future storing and shipping of the Instrument. 2.2 Warranty The Simpson Electric Company warranty policy is printed on the inside front cover of this manual. Read it carefully before requesting a warranty repair. For all assistance, including help with the Instrument under warranty, contact the nearest Authorized Service Center. If necessary, contact the factory directly, give full details of any difficulty and include the Instrument model number, serial number (at the back of the Instrument) and date of purchase. Service data or shipping instructions will be mailed promptly. If an estimate of charges for non-warranty or other service work is required, a maximum charge estimate will be quoted. This charge will not be exceeded without prior approval. 2.3 Shipping Pack the Instrument carefully and ship it prepaid and insured. 2.4 Operation Instructions The Instrument may be operated in a horizontal or vertical position. 6

3. CONTROLS, CONNECTORS & INDICATORS The 385-3L has five Functions. Each Function is described in Table-3. Numbers on Table 3-1 correspond with each numbered Function on Figure 3-1. Before attempting any operation of this Instrument, become familiar with each Function. Practice readings will avoid mistakes and prolong the life of the Instrument. 3.1 Front Panel The following paragraphs will describe, with the aid of Figure 3-1, the principal controls of the 385-3L.! Figure 3-1. Panel Front Table 3-1. Controls, Connectors, & Indicators 1. Zero Adjusting Screw: If pointer is off zero, adjust screw slowly clockwise or counter-clockwise until the pointer is exactly over the black diamond symbol, (extreme left side of the dial). 2. Probe Connectors: These provide connections for the probes used with the 385-3L 3. Function Switch: This is a three position switch: OFF, READ, and ADJ. It is used to select the proper mode for accurate readings. 4. Control Adjustment Screw: Use a screwdriver to turn this control. It is used when the function switch is in the ADJ mode. 5. Probe Selector: A three-position switch used to select the proper mode when taking a temperature reading. 7

4. OPERATION Before proceeding with the operation of the 385-3L, review the shock hazard definition printed at the front of this manual. This section of the manual contains information required to use and operate the 385-3L in a safe and proper manner. 4.1 Safety Precautions The 385-3L should only be used by personnel qualified to recognize shock hazards shock and trained in the safety precautions required to avoid personal injury. 1. Do not work alone when making measurements of circuits where a shock hazard may exist. Notify another person that you are, or intend to make such measurements. 2. Locate all voltage sources and accessible paths prior to making measurement connections. Check that the equipment is properly grounded and that the right rating and type of fuse(s) is installed. Set the Instrument to the proper range before power is applied. 3. Remember: Voltages may appear unexpectedly in defective equipment. An open bleeder resistor may result in a capacitor retaining a dangerous charge. Turn off power and discharge all capacitors before connecting or disconnecting test leads to and from the circuit being measured. 4. Hands, shoes, floor, and workbench must be dry. Avoid making measurements under humid, damp, or other environmental conditions that could affect the dielectric withstanding voltage of the test leads or Instrument. 5. Do not come into contact with any object which could provide a current path to the common side of the circuit under test or powerline ground. Always stand on a dry insulated surface capable of withstanding the voltage being measured, or that could be encountered. 4.2 Test Probes The Simpson Test Probe (00790) is recommended when surface temperature measurements are to be made. When free air ambient temperature measurements are to be made, the Simpson Test Probe (00789) is recommended. 4.3 Preparation For Use 1. Plug the probes into connections marked 1, 2, and 3 on top of the Instrument. 2. With the function switch OFF, it should be at the black diamond on the scale. If it does not, correct the reading by turning the zero adjusting screw 8!!

on the face of the Instrument cover. 3. Set the function switch to the ADJ position; the Instrument should read 32 o F. If it does not, correct the reading by turning the slotted adjusting control (located below the Simpson trademark). When it becomes impossible to correct the reading to 32 o F, replace the battery (paragraph 5.1). 4.4 Temperature Measurements! Use extreme caution around electrical equipment. The thermistor probe tip might inadvertently make electrical contact with a live circuit. The metallic probe part could also become live and present a shock hazard to the user. Do not use the probe in such a case until the electrical power is known to be off. Once power is applied; avoid contact with the Instrument or cable. Be sure the circuit is de-energized before removing the probe. 1. Locate probes at the points where temperature readings are desired. 2. When measuring air temperature, allow several minutes for the temperature of the probe sensing element to stabilize before taking a reading. Liquid temperatures can be read within a few seconds after complete immersion of the probe body. The general rule is to allow time for the probe to attain the temperature of the object being measured. 3. Set function switch to the READ position. 4. Set the probe selector switch to the position selected for the first reading, then read temperature. 5. Set probe selector switch to other positions being used and take rapid, successive readings as often as desired. 6. When readings are completed, return function switch to the OFF position. It is not necessary to disconnect leads from the tester. Do not use probe in acids or other solutions which will damage the brass shell or the plastic cord.! These servicing instructions are for use by qualified personnel only. To avoid electrical shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. 9

5. SERVICING INSTRUCTIONS This section will describe the necessary procedures needed to effectively service this Instrument. 5.1 Battery Replacement Replace the battery only if unable to adjust reading to 32 o F as in paragraph 4.3, item 3. To replace the standard C size flashlight battery, remove the four screws on the bottom of the case which holds the lower panel in place. Slide the lower panel away from the Instrument cover about 1/32 inch to release stop on top edge of panel, then lift the panel free of the case to gain access to the battery. (Use insulated type batteries only.) 5.2 Calibration If the Instrument is known to require calibration, or if the accuracy of the calibration should be checked, proceed as follows: 1. With the function switch OFF, check for a reading of -50 o F. If necessary, correct reading with zero adjusting screw on the face of the Instrument. 2. Set the function switch to the READ position. 3. Using an ice point reference source take a temperature reading. 4. If the reading is not exactly 32 o F, turn the slotted adjusting control below the Simpson logo until the meter indicates 32 o F, exactly. 5. Turn the function switch to the ADJ position. The meter should still indicate 32 o F. 5.3 Care 1. Immediately clean all spilled materials from the Instrument and wipe dry. If necessary, moisten a cloth with soap and water to clean plastic surfaces. 2. Whenever possible, avoid exposure or usage in areas which are subject to temperature and humidity extremes, vibration or mechanical shock, dust or corrosive fumes or strong electrical or electromagnetic interferences. 3. Monthly Care: Verify Instrument calibration by performing operational checks using known value sources. If the need for calibration is indicated, contact the nearest Authorized Service Center. 4. Annual Care: It is recommended that the Instrument be returned annually for a complete overall check and calibration. 5. Storage: When the Instrument is not in use, store it in a location free from temperature extremes, dust and corrosive fumes, and mechanical vibration or shock. 5.4 Replacement Parts Table 5-1 lists parts in order of their reference designators and indicates their description. (Refer to Table 1-2 for Items and Accessories Furnished With This Instrument.) 10

To obtain replacement parts, address order to the nearest Authorized Service Center. Refer to paragraph 2.2. for ordering instructions. Table 5-1. Replacement Parts List Ref. Sym. Description Part No. R1 Resistor, 57.7k, 0.5% 1-119734 R2,R3 Resistor, 7.56k, 1% 1-119735 R4 Resistor, 9.25k, 1% 1-119736 R5 Resistor, 5.1k, 5% 5-119351 R6 Resistor, 3.31k, 0.5% 6-114951 R7 Potentiometer, 50k, 20% 6-114974 S1 Switch, Probe Selector 6-114965 S2 Switch, Function Selector 6-114966 M1 Meter, 0-50 DC µa 10-865868 Knob Function & Probe Selector 3-260180 Set Screw, Knob 1-114178 Figure 5-1. Wiring Diagram M1 R1 50 A R6 57.7K + 3310 2100 R4 R7 R5 9250 R2 7560 50K 5100 R3 7560 SW1 A 1 2 3 SW2 B1 + 1.5V 7 8 9 C 1 2 3 A NOTES: Unless specified, resistors are in Ohms Switches show in extreme counter clockwise SW1 Probe selector SW2 Function selector 11

SIMPSON ELECTRIC COMPANY 853 Dundee Avenue Elgin, IL 60120-3090 (847) 697-2260 FAX (847) 697-2272 Printed in U.S.A. Part No. 06-114985 Edition 4, 10/02 Visit us on the web at: www.simpsonelectric.com 12