Chromat Calibration Updated October 27th, 2017

Valve Communication Solutions Axiom

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

Burner Management System DEMO Operating instructions

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

Technical Bulletin, Communicating with Gas Chromatographs

BUBBLER CONTROL SYSTEM

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

TECHNIQUES OF COMPOSITE SAMPLING. Kris Kimmel. YZ Systems, Inc Pollok Drive Conroe, Texas 77303

BUBBLER CONTROL SYSTEM

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

5890II GC Standard Operating Procedure 9/2/2005

Equipment Operating Procedure Glove Box

MyControl Bathing System Signature Series

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

AX5000 Operational Manual

EDUCATION DEPARTMENT ACCU-TEST

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

Automatic Valve Proving Control

SEPARATION SYSTEMS. The Separation Systems consists of the Test Header (GAY-0302) and the Test Separator (MBD-4501).

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Instrument Performance Evaluation, comparing ISO and NORSOK I-106 Dr Paul Holland, EffecTech Group & Jon Carlsen, Norsk Analyse North Sea Flow

ACV-10 Automatic Control Valve

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

This test shall be carried out on all vehicles equipped with open type traction batteries.

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Sedan Range. Evaporative Loss System Check Clarified Procedure

6890 GC Not Ready Messages (A16010)

Operating Instructions EB EN. Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication

Basic ICP Operating Procedures

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Flammability Chart. Gas Formula Ignition

Review of ISO10723 Performance Test Frequency. By Anwar Sutan

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Operation & Maintenance Manual GDS-68XP

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

RAM 4021 Operation Manual

SECTION P4 SEPARATION SYSTEMS

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Partial Stroke Testing for SRD991 and SRD960

MP15 Jockey Pump Controller

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

CPF 270, CPF 340. Instruction book

GAS COMPRESSION SYSTEM

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

University of Minnesota Nano Center Standard Operating Procedure

NOTICE. Issued: February 12, 2010 AO# Dundas Street West, Oakville, ON CANADA Phone: (905) Fax: (905)

Instruction Manual VCG-6

Leakfinder INSTRUCTION MANUAL. Diagnostic Smoke Vapor Machine. Model No. WV605. with UltraTraceUV Dye Solution

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

6800 Maintenance Instruction System Flush Procedure

SPECIFICATIONS ATTENTION

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants

WATER CONTROL SYSTEM QUICK START

RAM Operation Manual

SCIENCE LAB UTILITY CONTROLS

6850 Series Control Module User Information

Electro-hydraulic control valve - Calibrate - Remote valve calibration

Stand-Alone Bubble Detection System

Model Description

Kelsow Work Instruction. Subsea Well Control Hydraulic Panel Operation

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

Declining Weight Blending System Quick Start Manual E Main St Marshall, IL Phone: Fax: Website:

H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

ASSISTANCE. Cardinal Health Pulmonetic Systems Medina Rd., Suite 100 Minneapolis, Minnesota

Avoiding Short Term Overheat Failures of Recovery Boiler Superheater Tubes

3 Flow and Pressure Control

NIV EAU MATIC ST User Manual Made in Canada

SL G3. Warning

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

Instruction Manual. Biogas Analyzer InCa Bio 04

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Bristol Fire Department Standard Operating Procedures. Multi Gas Detector

Calera Fire Department Breathing Air System Technical Specifications

GREAT THINGS TO KNOW ABOUT YOUR. IRwin Methane Leak Detector

SECTION P4 SEPARATION SYSTEMS

Recommendations on Checking Anaesthesia Delivery Systems

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

SL G3 - Fuel Conversion to Natural Gas (LP to NG) P-Kit 301

Operation of the Perkin Elmer TGA-GC/MS

Oxygen Measurement in Natural Gas

The Air Liquide Gas System Equipment Brochure

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

University of MN, Minnesota Nano Center Standard Operating Procedure

Transcription:

Gas Chromatograph Operation Gas Company GC Initial setup - 6 Feb 2007 The Gas Company Gas Chromatograph (GC) data now come into Wonderware and can be accessed from the Gas Chrom button on the Wonderware Menu Bar. The Gas Chromatograph page displays all the alarms and shutdowns associated with the gas chromatograph, as well as the analog values of the most important gas stream components. (More data can be found on the Detail page). The Gas Company GC takes samples roughly every 8 minutes. (The actual sample rate seems to fluctuate in a 5-part cycle: 495 seconds, 495 seconds, 511 seconds, 495 seconds, 404 seconds and then repeating...) If the GC sample indicates that any of the gas values are above their Gas Company shutdown setpoints, then the Gas Quality Shutdown bit is set and an alarm is generated, but the Gas Shipping Valve does not shut down, yet: it takes (2) bad samples to close the valve and (1) good sample to open it back up. If the second sample is also bad, then the Gas Shipping Valve closes. ALARMS There are 4 alarms which are provided to give the operators a better understanding of what is going on with the GC. These are for information only. No operator action is required. Low Helium (this is used to purge / calibrate the GC) Low Cal Gas (this will invalidate the daily GC calibration) AC Power (active only after a power failure when the UPS has totally drained) GC Fail (this is a type of equipment failure) SHUTDOWNS NON-LATCHING A non-latching shutdown occurs when gas quality is out of spec for 2 cycles of the Gas Company gas chromatograph. After the first cycle, an alarm is generated to alert operators to the out-of-spec condition. After the second cycle, the Shipping Valve is closed. After one good cycle, the valve is reopened. Component Shutdown Setpoint O 2 2000 ppm CO 2 3 % Total Inerts 4 % Dry BTU High 1150 Dry BTU Low 970 Benzene 200 ppm H 2 S 4 ppm Electrical Page 1 of 6 Date Printed 01/07/08

SHUTDOWNS LATCHING Critical shutdowns do not require 2 cycles of the GC before they shutdown. In fact, they are not related to the GC at all. They indicate a serious condition which MUST be resolved. The Shipping Valve will be immediately closed and locked-out. This type of a latching shutdown requires that the operators call the Gas Co. A service technician will be dispatched. Once he has verified that the equipment is operating correctly he will reset the shutdown and the Shipping Gas Valve will open as long as the gas quality is good. High H2S Shutdown (this come from the Del Mar) H2S Fail (this also comes from the Del Mar) Odorant Shutdown (this comes from the YZ Odorant Injection skid Electrical Page 2 of 6 Date Printed 01/07/08

1. The H button opens the Historical Trend window. 2. The Detail button opens the Detail window showing additional, non-critical, values for the gas stream, e.g., methane or ethane. 3. The Gas Chrom button opens this window (the Gas Chromatograph window). 4. Seconds Since Last Update counts the number of seconds since the PLC numbers have changed. If the PLC loses communications with the GC this number will just keep counting. Usually this number resets to 0 after 400-500 seconds. 1. The analog values of O2, CO2, Inerts, BTU, Benzene, and H2S are shown in blue. When any of these values rises above the Venoco alarm setpoints, the background changes to yellow and a process alarm is initiated. 2. There are 2 separate solenoid valves at the gas shipping area which control the same shutdown valve. If either of these SOVs are activated, the appropriate box will appear in red and the display will read Closed. Electrical Page 3 of 6 Date Printed 01/07/08

1. The Alarm and Clear setpoints are driven by the company PLC. These are hard-coded into the PLC, but they can be changed by the programmer if Operations decides that different setpoints will provide for better operator control. 2. The background color for the analog values is determined by the company alarm setpoints, not the Gas Co. shutdown setpoints. 3. When any of these analog values exceed the Gas Co. shutdown setpoints, an alarm is generated, and the Gas Quality background changes to red. The text changes from Normal to Shutdown. 4. This means that at least 1 bad sample has been detected, NOT that the sales gas valve is closed! Electrical Page 4 of 6 Date Printed 01/07/08

1. The Shutdown setpoints for Gas Quality are driven by the Gas Co. gas chromatograph. These setpoints are not adjustable. If any of the analog values rises above its setpoint, the GC trips the Gas Quality Shutdown Bit. 2. When this happens, the background for the Gas Quality shutdown turns red. This will happen after the first bad sample to the GC, but the Gas Quality SOV will still show Open until after the 2 nd bad sample. 3. After the second bad sample, the Gas Quality SOV will show Closed. 4. Once the Gas Quality at the GC clears the Gas Quality SOV will show Open and the Gas Quality will again show Normal. 5. At least one analog value will probably still be yellow. It will stay yellow until it drops below the Alarm Clear setpoint. Electrical Page 5 of 6 Date Printed 01/07/08

Helium, Cal Gas, AC Power, and GC Fail are Gas Co. alarms and are only provided to give the operators a better understanding of what is going on with the GC. No operator action is required. 1. The Gas Quality Shutdown is a non-latching shutdown. It takes 2 bad samples to close, 1 good sample to open. The valve opens automatically. 2. The High H2S Shutdown, H2S Fail, and Odorant Shutdown are all latching shutdowns. Operators need to call the Gas Co. and have them come out and reset their equipment before the Gas Shipping Valve will reopen. 3. I believe all 3 latching shutdowns will close the H2S SOV, but I am not sure. Need to verify with the Gas Co. Electrical Page 6 of 6 Date Printed 01/07/08