Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Similar documents
Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

APPLICATION NOTE. GC Integrated Permeation Device

Application Note AN-107

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Retention Time Locking: Concepts and Applications. Application

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

A New GC/MS System Designed for Helium Carrier Gas Conservation

FAST EVAPORATION AT NORMAL PRESSURE

Multiple Gas#5 GC configuration Jan 2016

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

Rapid and Reliable Detection of Dissolved Gases in Water

HiQ laboratory gas generators.

Setting a New Standard in Flash Chromatography Performance

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

Your local gas generation partner. Precision series Modular gas generation solution for GC.

The Preparation of Low Concentration Hydrogen Sulfide Standards Gulf Coast Conference September 12, 2002 Galveston, TX Paper 050,12:45 pm Moody F

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Zebron Gas Management

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

Automated Liquid Handling Station

The instrument will process the samples one by one till all the samples have been cleaned up.

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Your local gas generation partner. Precision series Modular gas generation solution for GC.

TECHNIQUES OF COMPOSITE SAMPLING. Kris Kimmel. YZ Systems, Inc Pollok Drive Conroe, Texas 77303

Experiment GC : Analysis of BTEX by GC-FID

MMS Mercury Monitoring System for Natural Gas

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

Automated Determination of Dissolved Gases in Water Anne Jurek

GCMSD-Headspace Analysis SOP

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Gas Measurement Fundamentals Certification. Curriculum

Improving distillation tower operation

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

ISO INTERNATIONAL STANDARD

490 Micro GC Site Preparation Checklist

6890 GC Site Preparation

Ultimate Performance in Gas Chromatography

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Drilling Efficiency Utilizing Coriolis Flow Technology

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Gas Chromatography. MS Vent Enhancement to the PreVent System to Optimize Operation with the TurboMass, TurboMass Gold, and Clarus 500 GC/MS Systems

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

CORESTA RECOMMENDED METHOD Nº 67

Model Description

Major Design Features

VERIFYING GAS CHROMATOGRAPH OPERATION AT CUSTODY TRANSFER LOCATIONS Murray Fraser Daniel Measurement & Control

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

VIC offers a variety of Calibrated Gas Leaks

Generating Calibration Gas Standards

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

no peaks missing peaks too small peaks increasing retention decreasing retention

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Carrier Gases in Capillary GC

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Best Practice for Identifying Leaks in GC and GC/MS Systems


Agilent 7697A Headspace Sampler

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

The Tekran Series 2600-IVS Difference!

Best Practices for Installation of Gaseous Sample Pumps

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

STANDARD OPERATING PROCEDURES

GAS CHROMATOGRAPHY MAINTENANCE USING UNCERTAINTY BASED CBM

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Superior Result from Analytical Instruments The constant purity of the nitrogen improves system stability and ensures reproducible results

Pneumatic high-pressure controller Model CPC7000

EasyLine Continuous Gas Analyzers. So smart, they re simple

Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

Addressing the World Shortage of Helium

Performance Verification of BioTek s Precision 2000 using Artel s Multichannel Volume Verification (MVV ) System

Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Vehicle and Engine Emissions Testing

Transcription:

Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION

Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography and proprietary technology. Wasson-ECE Instrumentation, the leader in custom configured analyzers, offers hardware-only solutions for customers with chromatography experience who would prefer to develop their own analysis methodology. We offer flexible equipment to ensure that our systems will work with your proprietary methodologies. Customers ordering a hardware-only configuration create guidelines for hardware design, select columns, and set operation parameters for the instrument. Wasson-ECE will then configure the hardware to customer specifications, submitting all hardware designs to the customer for final approval. We're committed to giving you the solution you need, so Wasson-ECE provides a limited one year warranty on the installed hardware. Our application chemists are also available for consultation to help you optimize your design. Wasson-ECE offers the following specialty GC hardware systems: Gas AutoSampler Pressurized Liquid AutoSampler Vapor Phase Injection System Variable Pressure Sample System Dynamic Blender WASSON - ECE INSTRUMENTATION Laboratory Hardware

AutoSamplers Save time and increase accuracy by adding autosamplers to your laboratory gas chromatograph. Wasson-ECE instrumentation offers two types of autosamplers: the Gas AutoSampler for heating and injecting pressurized gas phase samples, and the Pressurized Liquid AutoSampler for injecting pressurized liquid samples at ambient temperatures. Gas AutoSampler The Wasson-ECE Gas AutoSampler automates delivery of pressurized gas samples to a GC at atmospheric pressure. The Gas AutoSampler includes an oven and heated transfer system that can send samples to the GC at temperatures of up to 150 C. Automated Injection Samples are placed in the Gas AutoSampler oven, which can hold twelve 500-cc sample cylinders or nine 1-liter cylinders. The shelves of the Gas AutoSampler can be modified so that they are sloped to prevent injection of any residual liquids. This modification limits the number of cylinders to a maximum of eight 500-cc or six 1-liter. Technicians then enter sample information into the Gas AutoSampler software, this software. This software enables the user to select the time interval between sample injection, set the temperature of the oven, log the sample injection times, and create data reports. Sample Protection The Gas AutoSampler is a stand-alone instrument that sends samples to the GC through a heated bridge, ensuring that samples are injected at oven temperature. This heated pathway is purged with carrier gas between each sample injection, and a vacuum pump ensures an extremely low level of cross-contamination (typically less than 50 ppm). Tel: 970.221.9179 www.wasson-ece.com

Gas AutoSampler (cont.) Pressure Regulation Samples at pressures up to 1200 psig are automatically regulated during the purging sequence so the GC injects all samples and calibration blends at atmospheric pressure. The Gas AutoSampler can also be configured to automate injection of samples that are already at atmospheric pressure. Accuracy and Precision Automating the sample injection process increases efficiency and prevents technicians from having to perform time-consuming, repetitive tasks. The Gas AutoSampler ensures that sample analysis is not only faster, but also more precise, accurate, and consistent. Compare the GC analysis results for the following 2 ml samples of n-pentane and n-hexane at 100 psig in propane. In the first run, the sample is sent to the GC from the AutoSampler at ambient temperature; in the second run the AutoSampler heats the samples to 130 C before injection. Table 1: Increase in Detector Accuracy and Precision with Heated Gas AutoSampler Component Unheated Sample Avg. Peak Area % Rel. Standard Deviation Sample at 130 C Avg. Peak Area % Rel. Standard Deviation Percent change in area Percent change in rel. std. dev. Propane 867938 0.22 % 849415 0.23 % - 2.1 % + 0.01 % n-pentane 24025 10.2 % 41282 1.35 % + 72.0 % - 8.85 % n-hexane 16475 16.7 % 56087 0.80 % + 240.0 % -15.9 % The Gas AutoSampler showed a 240% increase in sensitivity to n-hexane and a 72% increase in sensitivity to n-pentane in the gas sample when heated. Make sure to get the range and sensitivity needed by using the Gas AutoSampler heated sample system! WASSON - ECE INSTRUMENTATION Laboratory Hardware

Pressurized Liquid AutoSampler Wasson-ECE offers laboratory automation for pressurized liquid samples such as liquefied petroleum gas (LPG) and natural gas liquids (NGL). Liquid samples at pressures up to 1200 psig are stored in sample cylinders. The Pressurized Liquid AutoSampler uses inert gases to maintain pressure so that the sample remains in the liquid state at ambient temperature as it passes to the gas chromatograph for analysis. Pressurized Liquid AutoSampler Features Purges automatically with carrier gas between each sample run Remote-starts the GC and the data recording software such as ChemStation Adds a date/time stamp to all samples Holds up to nine 3.5 inch-diameter sample cylinders Works with standard open or floating-piston sample cylinders Pauses automatically when it detects that the GC is not running or not ready Can interrupt the scheduled sample sequence to process a priority sample Tel: 970.221.9179 www.wasson-ece.com

Pressurized Liquid AutoSampler (cont.) Quick Connect When samples enter the laboratory, they are placed in the Pressurized Liquid AutoSampler, which will transfer pressurized samples to the gas chromatograph. Sample cylinders with 1/4 inch tube fittings, VCO, or "Quick Connect" fittings can be inserted directly into the top plate of the sampler. These fittings will hold the sample cylinders vertically, ensuring that samples are drawn from the bottom of the cylinder. Sample cylinders with smaller tube fittings can be held vertically with an optional cylinder rack. WASSON - ECE INSTRUMENTATION Laboratory Hardware

Variable Pressure Sample System The Variable Pressure Sample (VPS) system works in two ways to ensure the precision and accuracy of gas chromatography results. The first method is pressure correction, used to create uniform pressure among all injected samples and the calibration blend. The second method is multipoint calibration, which can be used to test the pressure ranges that will deliver accurate results from a calibration blend. Pressure Correction The VPS pressure-correction system is a multistep process that ensures samples and calibration blends are at uniform pressures when they are injected. First, when the calibration blend is run through the GC, the VPS measures and stores the pressure of the calibration blend at the time of injection. Then, as each sample is injected at the stored pressure, the VPS adjusts the pressure of the sample to match the pressure of the calibration blend. The inject pressure of the sample is reported to Agilent Technologies ChemStation software so calculations and quality control operations can be performed. Multipoint Calibration Using the VPS, you can run calibration samples at various pressures from a single standard. This decreases overall lab costs while ensuring greater accuracy in results. The multipoint calibration function allows you to test for signal linearity at different pressures. With this feature, you can easily pinpoint the range of pressures where you will receive accurate and meaningful results from your calibration standard. Fig. 1: Example range of linear values for the calibration blend Tel: 970.221.9179 www.wasson-ece.com

Vapor Phase Injection System The Wasson-ECE Instrumentation Vapor Phase Injection (VPI) system uses an innovative, proprietary technique to vaporize liquid samples for injection in an existing gas chromatography system. This convenient laboratory system allows flexibility and gives accuracy when switching between gas and liquid samples. Advantages of VPI The Wasson-ECE vapor phase injection system is not only more convenient than a typical liquid sample valve, it also gives more accurate results. The VPI injects liquid or gas phase samples with a single valve. All liquid samples are vaporized and run at a constant pressure, eliminating sample density changes that cause errors in liquid phase samples. This ensures sharp, easy-to-read peaks for all samples. Sulfurs and Oxygenates The VPI is available with optional Restek Silco-Steel parts for analyzing trace reactive analytes such as sulfurs and oxygenates. Consistency and Accuracy Wasson-ECE's unique, proprietary vaporization technique produces an even and accurate gas sample. Other vaporizers use tubing with too large a volume, causing samples to fractionate when vaporized. This can lead to incomplete sample analysis. The Wasson-ECE vaporizer controls the injection volume so that all elements in the liquid sample are vaporized and sent to the GC simultaneously, producing a complete and accurate analysis of the sample. VPI Features Inject liquid and gas samples with a single valve High sample throughput Purging technique reduces cross-contamination Stop sample flow to the GC at any time Controlled injection volume WASSON - ECE INSTRUMENTATION Laboratory Hardware

Dynamic Blender The dynamic blender is a portable blending device that dilutes a sample or a certified standard with a matrix gas of choice. The device can blend both liquids and gases. An inert flow path and heated bridge eliminate adsorption and condensation problems when blending gas standards that include sulfur, nitrogen, and other reactive compounds. The samples are fed directly to a gas chromatograph, eliminating the need to store multiple gas samples. The dynamic blender may optionally contain a digital flow controller that allows the diluent gas to be controlled digitally. The Wasson-ECE Dynamic Blender provides reliable point-of-use calibration blends. The onboard vaporizer allows the user to dilute and vaporize heavy liquid samples into the gas phase. The dynamic blender then delivers the sample to the gas chromatograph for reliable calibration. The final concentration is a function of the flow rates of the sample and the diluent gas. Tel: 970.221.9179 www.wasson-ece.com

Custom Sample Systems Wasson-ECE has extensive experience building custom sample systems. Systems can be purged and rated for use in Class I, Division 2, Groups C & D areas. They contain block and bleed valves to eliminate sample cross-contamination, and sample line filters. The sample boxes maybe heated and can employ specialized tubing and components to prevent trace analyte adsorption. Custom Design The sample system is designed to meet your specific needs and is custom built to order. This includes custom cabinet design, purging, temperature control, and valves. The systems are built to work with your existing systems and automation. Sample System Features Class I Division 2 Groups C & D enclosures Liquid and gas sampling systems Temperature controlled cabinets Custom valves and plumbing to customer specifications One year warranty WASSON - ECE INSTRUMENTATION Laboratory Hardware

Wasson-ECE Instrumentation Engineered Solutions, Guaranteed Results. Wason-ECE Instrumentation specializes in configuring and modifying new or existing gas chromatographs exclusively from Agilent Technologies to become guaranteed, turn-key analytical systems. Our customers describe their objectives and their samples: analytes, concentration ranges, phases, temperature, throughput, and any special needs. From this dialog we configure a task specific instrument. We add extra ovens, valves, plumbing, flow control, columns, electronics, and software to yield a complete solution. This saves our clients valuable time and delivers instruments that are state-of-the-art and ready for use upon installation. The complete analytical method is developed, tested, and documented utilizing our experience working with numerous companies with similar needs and goals. The resulting chromatograms and reports are inspected by our application chemists and you, to ensure system performance and design quality. Our field engineers then install each system and provide training. After installation, and throughout the life of the chromatograph, our support chemists are ready to help. We can assist with application details, questions, training, calibration, maintenance, and on-site service. Wasson-ECE brings experience and efficiency to your project, giving you confidence in the quality of your results. Tel: 970.221.9179 www.wasson-ece.com

Please contact us for more information. Engineered Solutions, Guaranteed Results. Tel: 970.221.9179 Fax: 970.221.9364 www.wasson-ece.com sales@wasson-ece.com