PHOENIX L300i Best-in-class Helium Leak Detectors

Similar documents
Protec P3000 (XL) Helium Sniffer Leak Detector

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Leak D. Leak Detecting Instruments. PHOENIX Helium Leak Detectors

ELD500 LEAK DETECTOR INSTRUCTION MANUAL. Publication number: D Issue: B Original Instructions. edwardsvacuum.com

PhoeniXL300. Leak detector. Operating Manual 10218_002_A2. Part numbers

Leak Detection. Catalog

Pneumatic high-pressure controller Model CPC7000

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Pneumatic high-pressure controller Model CPC7000

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Leak Detection. Catalog

628 Differential Pressure Decay Leak Tester

Chapter 6 Leak detection

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Panther 5 Acute Care Ventilator

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Traysealer T 100. Tray packaging in the smallest space

Pressure calibration. 20

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Operating Instructions

Leak Checking Large Vacuum Chambers

GA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No

Industrial pressure controller Model CPC4000

High Performance Mass Spectrometers

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Digital dead-weight tester Model CPD8500

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HIGH PERFORMANCE LEAK DETECTORS ASM 182 SERIES / ASM 192 SERIES

SonoMeter 30 Energy Meters

Pneumatic service kit Model CPG-KITP

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Digital deadweight tester Model CPD8500

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

h2000 plus HyDROGEN LEAk DETECTOR

EasyLine Continuous Gas Analyzers. So smart, they re simple

Premium Series: Pressure, Differential Pressure and Level Transmitters. PASCAL Ci4. Chemical industry Mechanical engineering Process industry

Hiden QIC Series Gas Analysers Real-time gas analysis systems

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

COMPACT HIGH PERFORMANCE HELIUM LEAK DETECTORS ASM 182 SERIES

VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES

Residual Gas Analysis Systems for Industry

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

HumiSys HF High Flow RH Generator

159 mm 154 mm. Subject to changes 10/2012

Vacuum Pumps. Turbomolecular Pumps F31 F32 F33 F34 F35 F36 F37 F38 F39 F40

Measuring range Δp (span = 100%) Pa

Sartorius CCL kg Prototype Mass Comparator

red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases

Additel 761 Automated Pressure Calibrators Selection Guide

Recirculating Coolers

Quadruple mass spectrometers (transducer type)

Major Design Features

Gas Pressure Regulator HON 200

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Hand-held pressure calibrator with integrated pump Model CPH6600

MANY REQUIREMENTS - ONE SOLUTION: SCENTY control

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

The New PHD 4 Portable Helium Detector

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Battery Powered Thermal Mass Flow Meters for Gases

Industrial pressure controller Model CPC4000

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Airox Supportair Ventilator

ADT 761 Automated Pressure Calibrator

Digital Mass Flow Meters and Controllers for Gases

The latest automotive systems require innovative leak test methods and fixturing.

Microscopy Cryogenic WORKSTATION. Performance by Design

We measure it. For gas and water installers. testo hpa. bar

The Helium Leak Detector

Additel 761 Automated Pressure Calibrators

Screw Compressors 11-22kW

Precision digital pressure gauge Model CPG1000

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Automatic Isokinetic Sampler. ST5 Evo

OPERATING MANUAL. jina80e1-a (0611) Catalog No from software version V Modul1000. Modular Leak Detector

Dräger RZ 7000 Test Equipment

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

BUYER S GUIDE AQUAlogger 530WTD

Additel 761 Automated Pressure Calibrators

Columbus Instruments

Additel 761 Automated Pressure Calibrators Selection Guide

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Precision pressure sensor Basic version Model CPT6020

ila ACTIVVE SYSTEM PLATFORM

Instruction Manual Dräger MSI P7 and MSI P7 plus

Transcription:

180.85.02 Best-in-class Helium Leak Detectors

The perfect Helium leak detector matching your demands The helium leak detector opens up new dimensions of productivity and reliability for your applications. The excels through ruggedness, rapid entry into the measurement mode, high measurement accuracy and reliability as well as flexibility of use. Being a mobile helium leak detector, the is equally suited for use on mass production lines and service work. It excels through its rapid entry into the measurement mode and an extremely short response time thereby fulfilling the requirements of industrial series production testing for example in the refrigerating and air conditioning industry. The oil-free gas inlet system allows the use of this leak detector in testing of optical systems, in analytical systems or in the semiconductor industry. Product Highlights Best-in-class: Lowest detectable leak rate for helium < 5 x 10-12 mbar l/s Quick start up (107 seconds) for high process efficiency Highest helium pumping speed for fastest measurements: - Pumping speed in Fine mode 3.1 l/s Excellent long-term stability without measurement deviations Energy-saving at a maximum power consumption of 420 W Fast internal calibration for efficient testing (38 seconds only) Premium class Helium leak detectors detectors Excellent performance: Leak detection starting at an inlet pressure of 15 mbar and from 1000 mbar inlet pressure when operated with a partial flow system Easy and mobile use due to its low weight (40 kg) Short recovering time after helium contamination High detection sensitivity for the measurement of smallest detectable leak rates Highly reliable and accurate measuring system: The outstanding quality ensures a long product life leak 24 MONTHS Extended W Helium Wa L300i rranty PHOENIX Refrigeration and air conditioning industry Automotive industry System integration of a PHOENIX Modul with external backing pump for fully-automated leak testing of diaphragm bellows W-Tech Automatisierungstechnik GmbH, A-6890 Lustenau

Professional leak detection - faster and better The proven standard in Helium leak testing! + Detectable leak rate 5. 10-12 mbar l/s + Start-up time < 2 min. + Wireless Applications Ideal tool for industrial series production testing, like refrigerating and air conditioning industries Quality assurance Research and development Power plant engineering Analytical instruments Plant engineering Semiconductor industry High and ultrahigh vacuum technology Customer Benefits Maximum mobility through the wireless remote control RC 310 WL Comfortable data loggina via remote control RC 310 Oil-free gas admission system 10 display languages selectable Leak rate display and conversion in refrigerant equivalents g/a, oz/yr and ppm read out in sniffer mode Integrated calibrated leak and automatic calibration 3 freely selectable trigger thresholds Switchable for the detection of H 2, 3 He and He Trend/bargraph leak rate display Transportation in any orientation Technical benefits Oil-sealed or dry compressing backing pumps for rapid evacuation of the device under test and for producing a high gas flow in the sniffer mode Specially designed turbomolecular pump for improving the pumping speed and the helium background characteristic The most reliable 180 mass spectrometer available providing a long-term market proven quality Ion source with two automatically switchable cathodes The optimum valve block ensures a significantly reduced recovery time after helium contamination and a high pumping speed

Maintenance-friendly and cost effective remote control + Mobile workplace systems + Cart versions Options Oil sealed vacuum system This leak detector model is suitable for most standard applications Dry Entirely oil-free vacuum system Integrated helium contamination protection Modul Additional forevacuum system, oil-sealed or dry, depending on the application For applications involving short cycles and/or for testing of large volumes Customer-specific configuration depending on the required leak rate, timings and gas type Cart System for mobile operation of the For the Modul the forevacuum pump can be integrated into the cart Design Characteristics Simple and convenient operation Angled operating panel for easy visibility of the instrument status Oil level glass at the housing for simple oil level checks Extremely long service life of the cathodes due to their Iridium/Yttrium coating Maintenance-friendly The design of the allows rapid access to all components in case of maintenance. The internal arrangement separates the mechanical from the electrical and electronic subassemblies completely and clearly. Thus mutual influencing and interferences are reliably avoided. All subassemblies can be removed or replaced with ease, thereby reducing servicing downtime to a minimum.

Smart accessories for flexible applications Smart Interface Technology + Remote control + Sniffer lines + Partial flow system + Calibrated leaks Accessories Remote Control The RC 310 remote control unit with touch screen operation provides convenient control of units as well as predessor models. Intuitive operation via color TFT 3.5-in. touch screen display Up to 100 m wireless operation or up to 34 m with wired transmission Pushbuttons for important menu functions (Start, Stop, Zero, On/Off) Leak rate display selectable (numeric, bar graph, circular trend) Data backup on internal 32 MB data logger (> 24 hours) or USB stick Ergonomic, rugged industrial design (IP42) Scroll function for measured data USB connection for data transfer and software updates Adjustable loudspeaker and headphone output Search function (paging) via audible signal and peak hold (max. value indication) For simultaneous detection of up to 10 leak detectors Sniffer Line SL 300/SL 301 Helium sniffer lines are used for testing objects with helium overpressure. Accurate pin-pointing of leaks Status LEDs red and green (SL 300) ZERO pushbutton (SL 300) Easy filter exchange Very fast response Extremely low detection limit < 1 x 10-7 mbar l/s Rigid sniffer tip 120 mm Very rugged industrial design Helium Sniffer QT 100 For sniffer leak detection within larger distances up to 50 meters between test object and leak detector. LeakWare PC Software Software for operating the leak detector through a PC as well as for displaying and processing the measured leak rate data. Hardware requirements: Windows Software > 486 DX, 8 MB RAM Partial Flow System The and MODUL can be supplemented by a partial flow system, providing the following benefits: Significantly faster pump down times and ready to measure Most suitable for large test volumes Faster response times Ready to measure already at an inlet pressure of 1000 mbar More rapid venting of large test objects or in mass production Transport Case 300 For impact protected transportation or storage of the PHOENIXL 300; including strong carrying handles, plastic castors and a separate case for accessories. Calibrated Leaks We provide a wide range of calibrated leaks for PHOENIX L leak detectors.

Technical Data Ordering Information Helium Leak Detector L300i Dry L300i Modul Lowest detectable helium leak rate Vacuum operation mbar l/s 5 10-12 3 10-11 5 10-12 a) -12 b) / 8 10 Sniffer operation mbar l/s 1 10-7 1 10-7 1 10-7 Maximum measurable helium leak rate Vacuum operation mbar l/s > 0.1 > 0.1 > 0.1 Measurement ranges 12 decades 12 decades 12 decades Maximum permissible inlet pressure mbar 15 15 15 Pumping speed during pumpdown, 50 Hz/ 60 Hz m 3 /h 2.5 / 3 1.6/1.8 depending on pump configuration c) Helium pumping speed in the vacuum mode l/s > 2.5 > 2.5 > 2.5 Time constant for the leak rate signal s < 1 < 1 < 1 Time until ready for operation min 2 2 2 Power consumption VA 420 350 200 c) Inlet flange DN 25 KF DN 25 KF DN 25 KF Dimensions (W x H x D) mm 495 x 456 x 314 495 x 456 x 314 495 x 456 x 314 Weight kg 40 35.5 30 c) a) with rotary vane pump TRIVAC D 25 B 25 m 3 /h [50 Hz] b) with scroll pump 30 m 3 /h c) for the complete range of appropriate vacuum pumps, please refer to the Leybold full line catalog, chapter leak detecting instruments. Ordering Information L300i Dry L300i Modul Helium leak detector 230 V, 50/60 Hz EU model 250000V01 250001V01 250002V01* 115 V, 60 Hz US model 251000V01 251001V01 250002V01* 100 V, 50/60 Hz Japan model 251100V01 251101V01 250002V01* PHOENIX CART 300 without E box 252 005 252 005 252 005 with E box EU version / US version 252 006 / 252 007 252 006 / 252 007 252 006 / 252 007 Accessories: Helium sniffer line with rigid sniffer tip 120 mm SL 300 with LED and Zero button, 4 m cable 252 003 SL 301, 4 m cable / 10 m cable 252 025 V01 / 252 026 QT 100 Helium sniffer quick test 155 94 LeakWare, data acquisition PC software 140 90 Partial flow system, 100-240 V, 50/60 Hz 140 20 140 20 Exhaust filter AF 16-25 for partial flow system 189 11 189 11 Transport case 252 004 V01 Remote control RC 310 C, with connection cable (4 m) 252 013 V01 RC 310 WL wireless, including wireless transmitter, battery charging power supply for integrated battery and additional connection cable (4 m) 252 014 V01 Wireless transmitter with connection cable for additional leak detector operation 252 015 V01 Extension cable for remote control (max. 3 extensions possible), 10 m 140 22 * without backing pump. Alternatively oil sealed or dry forevacuum pump possible For detailed information and for the complete range of accessories, please refer to the Leybold full line catalog. BICOM 13810.01 180.85.02 4.2,5.07.16 mzs Printed in Germany on chlorine-free bleached paper Technical alterations reserved Leybold GmbH Bonner Str. 498 D-50968 Köln T +49 (0) 221-347-0 F +49 (0) 221-347-1250 info@leybold.com www.leybold.com