SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z TROXLER ELECTRONICS LABORATORIES, INC. James Pratt Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accredited Laboratory

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PRECISION MEASURING CORP Groesbeck Hwy. Fraser, MI Robert Meyer Phone:

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

molbox1+ Flow Terminal ± % of reading lowest uncertainty for gas flow calibration

Certificate of Accreditation

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

FPG8601 Force Balanced Piston Gauge

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY

Certificate of Accreditation

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

PG7000 high line differential mode for defining differential pressure at line pressures above atmospheric pressure (PG7000 V2.

CALIBRATION CERTIFICATE # 500

EN ISO/IEC Technical Requirements

CHAPTER 31 IDEAL GAS LAWS

Certificate of Accreditation

Automated Mass Handling for High Performance Pressure Balances

GAS MIXTURES. Department of Mechanical Engineering

Pressure calibration. 20

Certificate of Accreditation

molbox1 molbloc Terminal (Ver and Higher) Operation and Maintenance Manual

MET 335W Fluid Mechanics Laboratory. Lab 1: Bourdon Tube Calibration. Nick Peak

Discovery HP-TGA 75/750. Site Preparation Guide

Gas mixtures. Individual solutions specifically for your application

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

PG9607 Piston Gauge. Automated primary pressure reference for absolute and gauge pressures to 500 kpa

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Interlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

LEAP CO 2 Laboratory CO 2 mixtures test facility

GMC-I Service GmbH Calibration Center

Properties of Fluids SPH4C

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

Pressure Calibration Solutions

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

Gas Mixture Two Components. Gas Mixtures Two Components

P3000 Deadweight Tester Setup, Part 1: Limited Partial Correction Method

Gas Metrology. SI-traceable: Primary Reference Materials Certified Reference Materials Calibrated Gas Mixtures Interlaboratory Comparisons

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Dr. Rogers Chapter 5 Homework Chem 111 Fall 2003

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

High-speed pressure sensor Model CPT6140

PRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

JCSS accredited laboratory Endress+Hauser Japan

Hydraulic pressure balance Model CPB5800

Additel 780 Series Pressure Controller

Engineering: Measurement Technology Pressure/Level (SCQF level 6)

Additel 761 Automated Pressure Calibrators

How to evaluate pressure measurement specifications

Precision pressure sensor Basic version Model CPT6020

XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Instrumentation & Data Acquisition Systems

Additel 780 Series Pressure Controller

Certificate of Accreditation

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

UNIT 10 - GASES. Notes & Worksheets - Honors

Pressure Measurement

Comparison APMP.QM-S2.1 Oxygen in nitrogen at atmospheric level

An experimental investigation of the influence of the expansion of the moist air on its relative humidity

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Ch. 14 The Behavior of Gases

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Gas Flow Calibration Basics

Guide for the uncertainty analysis in pressure when using P3000 Series Deadweight Testers

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

Determination of Air Density with Buoyancy Artefacts

Primary standard differential pressure balance Model CPB6000DP

Pressure Metrology in Mexico

Pressure Measurements

molbox RFM (Ver 1.10 and Higher) Reference Flow Monitor Operation and Maintenance Manual

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Unit 9: Gas Laws REGENTS CHEMISTRY

Additel 761 Automated Pressure Calibrators Selection Guide

3 1 PRESSURE. This is illustrated in Fig. 3 3.

ISO INTERNATIONAL STANDARD

Third measurement MEASUREMENT OF PRESSURE

Unit 8: Gases and States of Matter

Integral type Differential pressure flowmeter VNT Series

THERMODYNAMICS, HEAT AND MASS TRANSFER TUTORIAL NO: 1 (SPECIFIC VOLUME, PRESSURE AND TEMPERATURE)

Additel 761 Automated Pressure Calibrators

2014 Programme of Training Courses in Measurement & Calibration

Flow Vision I MX Gas Blending Station

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 FLUKE CALIBRATION, PHOENIX PRIMARY PRESSURE AND FLOW LABORATORY 4765 East Beautiful Lane Phoenix, AZ 85044 Mike DiGioia Phone: 602 773 4731 CALIBRATION Valid To: March 31, 2019 Certificate Number: 1599.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Electrical DC/Low Frequency Devices Measuring the Electrical Output of Flow & Pressure Devices (1 to 100) mv DC 100 mv to 1 V DC (1 to 10) V DC (10 to 100) V DC (1 to 21) ma 0.005 % + 0.0061 mv 0.004 % + 0.058 mv 0.004 % + 0.076 mv 0.005 % + 0.6 mv 0.013 % + 0.00024 ma Fluke 8846, Agilent 34401A Up to 120 0.0014 % + 0.005 Agilent 3458A II. Fluid Quantities Gas Flow N 2 & Air Argon Helium Carbon Dioxide Sulfur Hexafluoride Hydrogen Propane Nitrous Oxide (0.1 to 1) sccm 1 sccm to 6000 slm 5 sccm to 3200 slm 10 sccm to 1800 slm 10 sccm to 155 slm 1 sccm to 6 slm 20 sccm to 200 slm 100 sccm to 16 slm 10 sccm to 20 slm 0.50 % + 0.002 sccm + 0.002 sccm Gravimetric determination & successive addition technique; flow units, sccm & slm are defined in SEMI E12-96 All Gases (1 to 500) sccm 0.096 % Rate of rise (A2LA Cert. No. 1599.01) 03/02/2017 Page 1 of 4

III. Mechanical Mass Nominal Values (2, 3.2, 4.0, 4.5, 5.0, 6.2, 6.4, 10.0, 10.1) kg (0.8, 1.0, 1.6,) kg 0.0001 % 0.00013 % True mass determinations for use with piston gauges (0.1, 0.2, 0.3, 0.4, 0.5) kg 0.0002 % All Values 1 mg to 16.5 kg 0.0005 % or 0.5 mg, whichever is greater Pressure Gas Effective Area of Piston - Cylinder (5 to 500) kpa (500 to 1000) kpa (1000 to 5000) kpa (5000 to 11 000) kpa (11 to 20) MPa (50 to 100) MPa 0.00048 % 0.00056 % 0.00067 % 0.00068 % 0.0012 % 0.0013 % 0.0015 % By comparison with the Fluke calibration piston-cylinder pressure calibration chain Secondary Standards & Pressure Devices (0 to 15) kpa (5 to 500) kpa (500 to 1000) kpa (1000 to 5000) kpa (5000 to 11 000) kpa (11 to 110) MPa 0.0025 % + 8 mpa 0.0009 % + 0.05 Pa 0.0010 % 0.0012 % 0.0014 % 0.0023 % & gauge (-15 to +15) kpa 0.0025 % + 5 mpa (-90 to 550) kpa 0.001 % + 0.3 Pa Differential mode line pressure from -90 kpa to 550 kpa (-990 to 990) kpa 0.0014 % + (0.1 Pa + 0.00013 % x LP) HL differential: LP (line pressure) range: 10 kpa to 1000 kpa (-50 to 50) MPa 0.0035 % + (0.00013 % x LP) Line pressure range: (1 to 100) MPa (A2LA Cert. No. 1599.01) 03/02/2017 Page 2 of 4

Pressure Oil Effective Area of Piston Cylinder (0.2 to 50) MPa (50 to 100) MPa (100 to 200) MPa (200 to 500) MPa 0.0013 % 0.0015 % 0.0022 % 0.003 % By comparison with the Fluke calibration piston-cylinder pressure calibration chain Secondary Standards & Pressure Devices (0.1 to 20) MPa (20 to 100) MPa (100 to 200) MPa (200 to 500) MPa (500 to 1000) MPa 0.0017 % + 14 Pa 0.002 % 0.003 % 0.0047 % 0.03 % Pressure Oil Secondary Standards & Pressure Devices 3 (0.1 to 20) MPa (50 to 70) MPa (70 to 140) MPa (140 to 200) MPa (200 to 350) MPa (350 to 500) MPa 0.0018 % + 14 Pa 0.0023 % 0.0025 % 0.0033 % 0.0038 % 0.0055 % 0.0075 % Pressure Devices 3 (except where noted) Gas (0 to 133) Pa 0.5 % + 0.15 Pa ; using capacitance diaphragm pressure transducer (1.4 to 5) kpa (5 to 550) kpa (5 to 550) kpa (550 to 2750) kpa (550 to 2750) kpa (2750 to 11 000) kpa (11 to 20) MPa (50 to 103) MPa 0.0015 % + 0.08 Pa 0.0015 % + 0.01 Pa 0.0015 % + 0.2 Pa 0.0017 % 0.0017 % + 0.2 Pa 0.0017 % 0.0019 % 0.0027 % 0.0038 % (-5 to 5) kpa 0.006 % + 0.04 Pa Differential; using quartz bourdon tube pressure transducer (-1.4 to -100) kpa 0.0015 % + 0.05 Pa Negative gauge (A2LA Cert. No. 1599.01) 03/02/2017 Page 3 of 4

IV. Thermodynamics Parameter/Equipment Range CMC 2 ( ) Comments Temperature (15 to 30) C 0.03 C Fluke thermistor Relative Humidity (5 to 90) % RH 3 % RH Vaisala humidity probe V. Time & Frequency Parameter/Equipment Frequency CMC 2, 4 ( ) Comments Frequency 1000 Hz 0.0008 % HP 53131A 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC. 4 In the statement of CMC, percentages are to be read as percent of reading, unless indicated otherwise. (A2LA Cert. No. 1599.01) 03/02/2017 Page 4 of 4