PurgEye 100 IP65 WELD PURGE MONITOR USER INSTRUCTIONS. Argweld PurgEye Family Range of Weld Purge Monitors

Similar documents
WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

RAM 4021 Operation Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Flexible Welding Enclosures

PurgEye 100 IP65 WELD PURGE MONITOR. Sealed Dustproof and Waterproof. Keeping your Eye on the Purge!

CSA Sample Draw Aspirator Adapter Operator s Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual

RAM 4021-DPX Operation Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

O2 Portable. User Manual

LogIT Dissolved Oxygen Probe

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

130 SSP Soluble Salt Profiler

PERSONAL AIR BREATHING UNIT

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

ANALOX ATA - Trimix Analyser. Technical Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

User Manual. Pro CO LP Alarm. Carbon Monoxide Analyzer and Low Pressure Monitor with Alarm REV: 03.19

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

SPECIFICATIONS APCEPH1

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Vers Gas Generator. Release III INSTRUCTION MANUAL. Advanced Calibration Designs, Inc.

ANALOX O2 PORTABLE OPERATORS MANUAL

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

256 Pneumatic Pressure Indicator

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

92831 TEL: (714) FAX:

with O 2 Controller Instruction Manual

Model PDT Dewpoint Transmitter

Operation Manual. Pro CO Analyzer TM. Pro CO with High Temp Alarm Carbon Monoxide Analyzer

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

In Vivo Scientific, LLC INSTRUCTION MANUAL

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

92831 TEL: (714) FAX:

GILMONT ACCUCAL FLOWMETERS

KJ4000 Operating Instructions & Parts Manual NSN

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Operation Manual. Pro CO O 2 Alarm. Carbon Monoxide and Oxygen Analyzer. Rev

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

PM105 PRESSURE METER USER S MANUAL

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

NEULOG OXYGEN LOGGER SENSOR GUIDE

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Purge Star & Ring Purge Systems

Operation Manual. O2 Quickstick. Oxygen Analyzer

Technical Data Sheet MF010-O-LC

Getting to know your Sureshotgps micro V3

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

BMW Motorrad. Installation Instructions. BMW Motorrad Communications System for Schuberth C3

200 PSI COMPRESSORS - MODEL NUMBERS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

MP15 Jockey Pump Controller

Duplex Commercial Softeners

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

RC 195 Receiver-Controller

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

We measure it. For gas and water installers. testo hpa. bar

OPERATION MANUAL NTF-15

GE Measurement & Control

SF 6 Product Guide. Gas Analysis Instruments and Accessories

453 Series Steam Heated Vaporizing Regulator

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

400C & 450C DUAL PERFORMANCE VALUE PACKS

Sterisil Ac+ Installation & Operating Manual

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

159 mm 154 mm. Subject to changes 10/2012

Using the UltraRAE. Firmware 2.35

Operating instructions Installation instructions To be kept in the vehicle!

Oxygen Contamination

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Hand-held pressure calibrator with integrated pump Model CPH6600

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

GasLab SAN-102 Micro Oxygen Monitor User Manual

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Transcription:

PurgEye 100 IP65 WELD PURGE MONITOR USER INSTRUCTIONS Argweld PurgEye Family Range of Weld Purge Monitors

INDEX PAGE 2 Index... 2 Introduction and features... 3 Understanding the monitor before turning on... 4 Understanding the monitor before turning on continued... 5 Methods of use... 6 Turning on the monitor... 7 Calibration... 8 Maintenance... 9 Replacing the sensor... 10 Warning, use with caution... 11 Zero calibration... 12 Zero calibration continued... 13 Spares and accessories... 14 Troubleshooting and fault finding... 15 The family series of Weld Purge Monitors... 16 Other languages... 17 Customer support and worldwide care... 18 Warranty... 19 Address and contact details... back cover

INTRODUCTION and FEATURES PAGE 3 The PurgEye 100 IP65 Sealed Weld Purge Monitor has been specifically designed for the welding industry and provides a low cost, high accuracy device for basic Weld Purge Monitoring. The PurgEye 100 IP65 features include: IP65 Sealed standard accredited. Dustproof sealed rated to level 6 (dust tight). Waterproof sealed to level 5 (protected against water jets). A newly developed user replaceable electrochemical sensor. A sturdy presentation case with swivel hinge design for safe storage of the instrument. User calibrate button for both 20.9% and 0.1% levels of oxygen and below. Quick connect/disconnect leak tight purge line connections. One piece leak tight stainless steel sampling probe and hose connector. Rubber aspirator bulb (sampling pump). 2 x AA batteries (included). Tripod mount with various tripod models available as accessories. Wrist/neck band mount together with auto break safety strap. Optional rubber protector for monitor housing. Range 20.94% ambient to 100 ppm with zero calibration facility. Battery replacement indicator. Sensor replacement indicator. Argweld PurgEye Family Range of Weld Purge Monitors

Understanding the MONITOR BEFORE TURNING ON PAGE 4 Sensor Housing Connectors The leak tight sensor housing connectors are designed to accept 6 mm OD polyurethane purge gas tubing for its low oxygen outgassing rates and best weld purging results. Small lengths of this tubing will be supplied with your PurgEye instrument, so that you can join your normal purge exhaust hose as required. We recommend that you purchase your desired length of polyurethane purge tubing from HFT to eliminate leaks that might arise from joining multiple purge hoses together. Connecting the Purge Gas Tubing The weld purge gas inlets and exhaust tubes simply push into the two tube connectors on the sensor housing cover as shown with the arrows on the picture. It doesn t matter which way around the tubes are connected. If the aspirator bulb hand pump is not being used, always ensure that there is an exhaust tube of at least 150 mm (6 ) in length connected to the other tube connector (this may need to be longer if using very low flow rates, in order to prevent atmospheric oxygen from migrating into the sensor chamber). HFT Extra 150 mm (6 ) tail pipe is included for free flow use Tube connectors

Understanding the MONITOR BEFORE TURNING ON continued PAGE 5 The best way to use your Weld Purge Monitor is to connect the exhaust tube from your purging system to one of the quick fit connectors on the front of the monitor. Then allow the exhaust gas to flow freely over the sensor, out to atmosphere using the 6 length of tube provided. If that method is not practical, then use the probe and hand pump to extract samples from the inside of the pipe or vessel. The probe should be placed through a weld gap near the top of the purge space and inserted so that the bottom of the probe only goes a short way below the weld zone for most accurate results. The weld joint must be taped and your probe inserted through the tape and into the weld gap. Should the purge gas exhaust be insufficient to use the monitor with a free flow of exhaust gas (as described above) and if the vacuum bulb and sampling probe are used instead, the aspirator bulb will be attached to one quick fit connector on the front of the purge monitor, while the sampling probe and tube is attached to the other connector. (See diagram on next page). Press the standby button once and the unit will turn on, initially it will display four dashes on the monitor. This indicates that the reading is over range (>40.00%). Follow the full-scale calibration procedure to start using the monitor. (See page 8). HFT

METHODS of USE PAGE 6 Connections with Sampling Bulb Connections with Bulb Pump This diagram shows connections for use with the bulb as sampling pump. Sensor Cover Sample Probe Bulb Pump As mentioned above, the PurgEye 100 IP65 can be used with a bulb as a sampling pump or connections for free flow. In the case of free flow, always ensure that there is a minimum of at least 6" (150 mm) in length of polyurethane tube connected to the other pipe connector (see lower picture). One piece leak tight probe and tube assembly for sampling purge gas through weld root (included). Sensor cover. HFT Connections for Free Flow Use this layout for zero calibration with 1 L/min flow rate of 99.99% argon gas. 150 mm (6") tail pipe (included). Tube to weld purge system. HFT

TURNING ON the MONITOR PAGE 7 Installing the Batteries Remove the battery cover on the rear of the device and install 2 x AA size standard alkaline batteries, ensuring the polarity is correct. Use only alkaline type AA batteries. Be careful not to lose the tiny screw(s). Turning on the Monitor (for the first time) After installing the batteries, the monitor will automatically turn on. There is no need to press the on/off button. The display shows immediately 88.88 for a second and will then show a reading above 20.94. Press the calibration button for the monitor to display 20.94, this may need to be repeated when the monitor is first used. Note: Follow the full-scale calibration procedure to start using the monitor, (see special note overleaf). Turning on the Monitor (thereafter) Press the standby button on the right (on/off) and the monitor will turn on. Initially it will display 88.88 on the screen a second. The display will then show a reading above 20.94.

CALIBRATION PAGE 8 Full-Scale Calibration Carefully remove the sensor housing cover (pull slightly and rotate the black round cover to remove) to expose the sensor element to atmospheric oxygen. Replace sensor cover after two minutes. Then press and hold the calibrate button for 5 seconds. After this time period the monitor will read ~20.94%. Leave the monitor a few seconds to ensure the reading has stabilised (this may take a couple of minutes after being switched on). If the reading varies significantly then hold the calibrate button again to re-calibrate the monitor. Note: It is recommended that the calibration procedure be carried out each time the monitor is used for a new job to ensure that the gas lines are not retaining residual levels of argon gas and to ensure that the monitor is starting with a reading of 20.94%.

MAINTENANCE PAGE 9 Low Sensor and Low Battery Indicators When the instrument displays a flashing! in the bottom left corner, it is indicating that it is time to replace the sensor. See spare parts list on page 14. When the monitor displays the battery symbol, replace the batteries, see below. HFT Installing the Batteries Remove the battery cover on the rear of the device, being careful not to lose the screws, and install 2 x AA size standard alkaline batteries, ensuring the polarity is correct. Use only alkaline type AA batteries. HFT

Replacing the sensor PAGE 10 Installing a New Sensor Carefully remove the sensor housing cover. Always gently rotate (quarter turn) the sensor housing cover while fitting or removing. Remove the sensor using the sensor removal tool by hooking it into the groove on the black part of the sensor, then simply rest the removal tool against the monitor and lever the sensor gently upwards. There is no membrane cover to remove on the sensor. After installation of the new sensor, reset the monitor by pressing the power button and calibration button at the same time then carry out the zero correction facility. Note: No force should be applied to the sensor, the sensor housing or the sensor cover. Do not squeeze the sensor with the sensor removal tool. HFT

WARNING, USE with CAUTION PAGE 11 Zero Calibration (Correction) Facility The PurgEye 100 IP65 Weld Purge Monitor is set for use by our quality control procedures prior to the product shipping to you. However, occasionally, it may be necessary to use the zero calibration facility. Please use the instruction on the next page for the zero calibration facility with extreme caution. Once the zero calibration facility has been used, it is vital that the instrument is placed on the argon gas facility for the alloted time schedule as shown on page 7. The procedure in this instruction booklet should ideally only be used after fitting a new sensor and not done randomly without good reason.

ZERO CALIBRATION PAGE 12 When a new sensor is fitted or where greater accuracy is required at very low readings, you may want to zero the monitor. This is done by first completing the full-scale calibration procedure above and then completing the following steps. 1. Switch the monitor on. 2. With older models, (non IP65 versions) we recommend that you start with a Reset. Push the Cal and the On/Off buttons simultaneously and hold for 20 seconds, until Reset appears in the display. Step 3 below is then unnecessary, so continue from step 4. 3. Repeat the Full Calibration procedure (See page 8). 4. Connect the sample tube directly to a supply of 99.99% Argon with a flow of 1-2 litres/min (2-4 CFH) using the freeflow method. (See page 6). 5. When the monitor has been reading for about 10 minutes and is displaying below 1%, press and hold the calibrate button for 5 seconds. The monitor will indicate calibration mode by flashing CAL on the screen. HFT

ZERO CALIBRATION continued PAGE 13 6. Once the reading falls below 0.5% the monitor will wait for the reading to stabilise and then take a reference reading, this should take several minutes, the longer the better. Once this is complete the screen will stop flashing CAL and display ~0.00%. 7. Now repeat the full calibration by pushing the cal button until ±20.94 appears in the screen. Your Monitor is now ready for use. Again, do not randomly use this facility. It is preferable that this zero calibration only be carried out when the PurgEye 100 IP65 is fitted with a new sensor. Note: The longer the purge time and the higher the purity of gas, the better the low level accuracy. We will gladly carry out the replacement sensor activity for you and provide you with an up to date calibration certificate. Please ask your nearest HFT Distributor for a quotation, or contact us directly at sales@huntingdonfusion.com.

SPARES and ACCESSORIES PAGE 14 Part Descriptions Order Code Replacement sensor... Sensor removal tool... Protective rubber housing (shown below)... Tripod (medium size)... Auto break safety wrist and neck strap... Sampling tube 6 mm OD x 2 m length... Leak Tight stainless steel probe... Aspirator bulb (sampling hand pump)... Sensor housing cover... Battery cover... Carrying storage and presentation case... Calibration certificate... (for quality control procedures only) 50m length purge tube... APIS101 APIS102 APIS103 APIS104 APIS106 APIS108 APIS109 APIS110 APIS111 APIS112 APIS125 APIS150 APIS Note: Whenever the sensor is replaced: DO NOT apply force to the sensor or the sensor housing as this can cause damage to your instrument. HFT Rubber protective cover Storage and carrying case supplied available as an accessory with all new instruments

TROUBLESHOOTING and FAULT FINDING PAGE 15 A Quick Guide in the Event of Problems If the reading does not fall below 20.9% after a reasonable purge time, or in the event that your reading does not pass your expected level of oxygen, please do the following: Check that the correct purge tubes are used for the quick fit leak tight connections in case air is leaking into the instrument. Check the purge gas quality at the source by taking your PurgEye 100 directly to the source (i.e. gas bottle) to verify your purge gas quality as well as ensuring that the connections are leak tight. Check the cleanliness of the components being welded. Could there be excessive cleaning material or dirt that might be outgassing? Note: Excessive oil and grease will outgas and may produce copious quantities of oxygen until all contamination has been purged. If you need to reset the monitor, begin by turning it off. Then press and hold the Cal button and the On button simultaneously. Hold both buttons until the word reset appears on the screen. You will then need to calibrate the monitor at 20.94% and at 0%. HFT

Argweld PURGEYE FAMILY RANGE of WELD PURGE MONITORS PAGE 16 The World standard PurgEye 100 IP65 Hand Held Push button Auto Calibration feature at precisely 100 ppm as well as at ambient (20.94%). Leak tight probe assembly. Low battery indicator and low sensor indicator. Increased sensor reading range. Quick connect/disconnect leaktight fittings for gas purge tubing. The PurgEye 200 IP65 Hand Held with PurgeNet Readings from 1,000 down to 1 ppm. Internal electro-mechanical pump with 1 l/m flow rate. USB lead included to control PurgeLog software. Long life, faster response sensor. Warning alarm levels between 1 and 999 ppm. Flow detection for accurate reading of gas samples. The PurgEye 300 Nano New unique solid state long life sensor. Less than 60 seconds warm up time. No need to constantly calibrate, integrally mounted sensor. Low cost, small, lightweight monitor reads accurately to 10 ppm. The PurgEye 300 Plus with PurgeNet Measures and indicates from 1,000 to 10 ppm (0.001%). A unique, fast response, lifetime sensor. PurgeLog data logging software* included. Internal alarm and security pin code facilities. 2m x 6mm polypropylene hose for inlet and outlet exhausts. The PurgEye 500 Desk with PurgeNet PurgeLog data logging software* included. Reads PPM or Percentage. Specially designed, extra long life sensor with faster response. OLED screen with stunningly clear, bright figures and text. Reading from 1000ppm - 1ppm. Audible alarm features to indicate low and high levels of oxygen. Visual Alarm System as an accessory. Integral pump with flow rate 3.5-4 l/m. The PurgEye 600 Touch Screen Reads PPM or Percentage. PurgeLog data logging software* included. Large touch screen with on-screen graph of the current weld. Internal sampling pump with gas filtration. User port with two outputs to control welding equipment or activate alarms in the event of a rise in oxygen levels. No more wet cells to keep replacing and recalibrating. Quick fit and quick disconnect leak tight purge tube fittings. The PurgEye 1000 Remote with PurgeNet Comes with a hand held display and a 10 m lead as standard. Optional 100 m reel of outdoor cable with locking connectors. Reels of extensions cable can be connected to make longer leads upto 1 km! Easy to pull through pipes. 1 ø stainless sensor holder to place at the weld site inside pipes to send purge data to the monitor up to 1km away. The PurgEye 1500 Site IP68 with PurgeNet Internal electro-mechanical pump with 3 l/m flow rate. USB lead included to control PurgeLog software. IP65 rated with the lid open, IP68 with lid closed. Warning alarm levels between 1 and 999 ppm. Flow detection for accurate reading of gas samples. Power on / off with standby button for sensor warm up. PurgeNet controls the welding power sources such as orbital welders and any other automatic welding systems to switch on and off according to oxygen levels, transferring data easily with the ability to link to external devices.

Other LANGUAGES in PROGRESS PAGE 17 Les autres langues sont actuellement dans le progrès. Pour le moment, s il vous plaît contacter votre Distributeur local Andere Sprachen sind momentan im Gange. Kontaktieren Sie vorläufig, bitte Ihren örtlichen Verteiler Otros idiomas son actualmente en progreso. Para ahora, contacta por favor su Distribuidor local

CUSTOMER SUPPORT and WORLDWIDE CARE PAGE 18 For further information and support, please contact us at: Internet: www.huntingdonfusion.com Email: hft@huntingdonfusion.com Tel: +44 (0) 1554 836 836 Worldwide Offices, Partners and Distributors are listed on our website or contact us and we will direct you to the correct location

WARRANTY PAGE 19 All products are thoroughly tested to our Quality Control Procedures prior to leaving our manufacturing facility. Should you encounter a problem with your product, please notify us immediately upon receipt. Huntingdon Fusion Techniques HFT warrants this product to be free of defects in workmanship and material, with exceptions stated below. Warranty applies for normal and intended use of the product. Huntingdon Fusion Techniques HFT will not be held responsible for any incorrect use of the product. For further warranty information, please refer to our terms and conditions. All warranties shall not apply to any product or component which has been repaired or altered by anyone other than Huntingdon Fusion Techniques HFT. Huntingdon Fusion Techniques HFT shall not be liable for indirect, special, incidental or consequential damage or penalties and does not assume any liability of Purchaser, or to others, for injury to persons or property. This warranty is in lieu of all other warranties, expressed and implied. E&OE

HFT API0100 IP65 UI-91 12-10-2017 ME HUNTINGDON FUSION TECHNIQUES HFT Stukeley Meadow BURRY PORT Carms SA16 OBU United Kingdom (UK) Tel +44 (0) 1554 836 836 Fax +44 (0) 1554 836 837 www.huntingdonfusion.com Email hft@huntingdonfusion.com E&OE Copyright HFT. All rights reserved. This publication may not be reproduced by any means without the written permission of Huntingdon Fusion Techniques HFT