Line Pressure Regulators Class I or Class II. FRS 7../6 Series

Similar documents
Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Ratio Regulator Zero Governor. FRG/6 Series

FRS 7../6 series are CSA Certified: ANSI Z21.80 / CSA 6.22 Class I. Commonwealth of Massachusetts Approved Product Approval code G

Butterfly Control Valve. DMK/6 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Commonwealth of Massachusetts Approved Product Approval code G

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Commonwealth of Massachusetts Approved Product Approval code G

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Pressure Switch for gas and air GGAO-A4

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Valve Proving System VDK 200 A S06*

Pressure Switch for gas and air

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Gas Pressure Switch for DMV safety shutoff valves

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Valve Proving System VDK 200 A S02

Pressure switch for gas and air

Gas Pressure Switch for DMV safety shutoff valves

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

Gas Pressure Switch for DMV safety shutoff valves

Pressure Switch for gas and air

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

SPECIFICATIONS ATTENTION

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

SPECIFICATIONS ATTENTION

Service and installation must be performed by a trained/experienced service technician.

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Pressure regulator FRS

Gas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved.

CATALOG. 2 nd Edition

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

SAV. Safety Shut-off Valve. Safety Shut-off Valve Type SAV

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Noth American 7347 High Pressure Gas Regulators

Slam Shut Valves SCN

Type R622 Pressure Reducing Regulator

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

North American Orifice Metering System

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

GAS SUPPLY DESIGN GUIDE

North American 7337A/B/C-4 High Pressure Gas Regulators

S300 Series. Valve Link. Features. Fisher Controls

Pressure regulator FRS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

SPECIFICATIONS CAPACITY

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Certified LP/Propane Line Pressure Regulator Guidebook

Type 299 Pressure Reducing Regulators

LINE PRESSURE REGULATOR GUIDEBOOK 7TH EDITION

G96 Series BASOTROL Dual Operator Valve

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Model 1800 PFM Series Regulator. Technical Bulletin

Gas Pressure Regulator HON 200

North American 7339 High Pressure Gas Regulators

GasMultiBloc Combined regulating and safety valve Infinitely variable air/gas ratio control mode MB-VEF B01

Old documentation - Only for your information! Product is not available anymore!

Compact pressure switches for gas and air

Gas Pressure Regulator HON 502

T208VR Series Tank Blanketing Vacuum Regulator

e G) GOVERNOR t,5 ii:i! Line Pressure Regulators

Instruction Manual No. 742, 8/98

Safety Shut-off Valve SSV

PRO-50 Instrument Supply Regulator

GAS SUPPLY APPLICATION GUIDE

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Transcription:

Line Pressure Regulators Class I or Class II FRS 7../6 Series CSA Certified ANSI Z21.80 / CSA 6.22 as a 5 PSI Class I or Class II Line Pressure Regulator File # 1205910 NPT Threaded Versions FRS 705/6 (1/2 NPT) FRS 707/6 (3/4 NPT) FRS 710/6 (1 NPT) FRS 712/6 (1 1/4 NPT) FRS 715/6 (1 1/2 NPT) FRS 720/6 (2 NPT) FRS 725/6 (2 1/2 NPT) FRS 730/6 (3 NPT) Class II Commonwealth of Massachusetts Approved Product Approval code G1091183 Gas pressure regulator FRS 7../6 LP Sales Brochure P/N 257194 Ed. 05/18 1 8 Codes and Standards This product is intended for installations covered by but not limited to NFPA 54, CSA B149.1 and the International fuel gas code. DUNGS is an ISO 9001 manufacturing facility. Description The FRS 7../6 Line pressure regulators are a balancing type, springloaded regulator with an adjustable setpoint. They feature an internal sensor for regulating output pressure. Input pressures up to 7 PSI (See specifications for more details) and NPT 1/2 to NPT 3 thread connections (FRS 7../6) Heavy duty diaphragm construction for durability and strength. Steady, precise and instantaneous regulation of the outlet pressure. Lockup type regulator (see page 2 and 3 for details). Factory installed vent limiter. Review applicable codes for vent line requirements. Class I Application The FRS series line pressure regulators are recommended for applications when incoming gas pressure from the service regulator needs to be reduced to a suitable pressure for the gas appliance pressure regulator. These are designed for high efficiency appliances, highturn down appliances, appliances using direct spark ignition or hot surface ignition, and other applications requiring a high performance regulator. The FRS is suitable for dry natural gas, propane, butane, air and inert gases. The FRS does not contain any nonferrous metals and is suitable for gases containing no more than 0.1 % by volume, dry H 2 S. A dry gas has a dew point lower than +15 F and its relative humidity is less than 60 %.

FRS Springloaded pressure regulator with adjustable setpoint spring. Internal/External impulse for regulating output pressure. Specifications Body size pipe size (Type NPT) Max. inlet operating pressure 705/6 707/6 710/6 712/6 715/6 720/6 725/6 730/6 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 7 PSI (500 mbar) at ambient +5 to +160 F and outlet 4 80 WC. 5 PSI (350mbar) applies to CSA Certification. Input pressure range for optimal control 2 in. W.C. to 200 in. W.C. (5 mbar to 500 mbar) Max. body pressure Output pressure range 15 PSI (1000 mbar) 1 in. W.C. to 80 in. W.C. (2.5 mbar to 200 mbar). See spring selection below. Materials in contact with gas Housing: Aluminum, steel (free of nonferrous metals) Seals and diaphragms: NBRbased rubber Ambient temperature Installation position Vent line connection / vent limiter Turndown Rated for 20:1 Hysteresis and Droop Lockup Rating +5 F to +160 F for up to 10 PSI for regulating behavior (+/ 10% of setpoint). F to +160 F for up to 5 PSI: Diaphragms are suitable for the low temperature, but there may be out of range regulating behavior. CSA Certified for F to +160 F for up to 5 PSI. Regulator dome from vertically upright to lying horizontally Vent line connection is G 1/4 for FRS s up to 1 NPT, and it is G 1/2 for FRS s 1 1/4 to 3 NPT. The FRS also has a factory installed vent limiter, which limits the escape of gas to less than 0.5 CFH @ 5 PSI in case atmospheric diaphragm ruptures. Venting required unless otherwise accepted by the authority having jurisdication. Hysteresis/repeatability is less than 10% for up to 7 PSI inlet. Average droop at 20:1 turndown is 10% for up to 7 PSI. The FRS meets the ANSI Z.21.80/CSA 6.22 as Class I, which allows lockup rating not more than 150% or 5 in. W.C, whichever is greater. The FRS meets EN 881 as SG30, which allows lockup as high as +30% of the outlet pressure. See Lockup pressure parameters on page 3 for more details FRS 7../6 Class I Order No. Pressure max. [PSI] Size FRS 705/6 267002 5 NPT 1/2 2.9 75 FRS 707/6 269320 5 NPT 3/4 3.9 100 FRS 710/6 269321 5 NPT 1 4.3 110 FRS 712/6 269322 5 NPT 1 1/4 5.9 150 FRS 715/6 267010 5 NPT 1 1/2 5.9 150 FRS 720/6 267012 5 NPT 2 6.7 170 FRS 725/6 269325 5 NPT 2 1/2 9.1 230 FRS 730/6 269328 5 NPT 3 10.4 265 Dimensions [inch] Dimensions [mm] a b c d e f 12.8 325 14.7 373 15.3 389 19.1 485 19.7 499 21.8 553 0.9 24 1.1 28 1.3 6 1.6 1.6 1.9 47 3.7 95 3.7 95 5.6 143 6.5 165 7.5 190 12.2 310 15.9 5 15.9 5 G 1/4 8.9 225 G 1/4 9.6 245 G 1/4 12.2 310 G 1/2 14.2 365 G 1/2 14.2 365 G 1/2 17.7 450 G 1/2 23.2 590 G 1/2 23.2 590 Weight [lbs] [kg] 3.0 1,4 5.0 2,3 6.5 2,9 13.0 5,9 13.1 5,9 17.0 7,7 2 8

FRS 7../6 Line Pressure Regulators Dimensions inch (mm) Replacement Spring Clearance d b e Field mountable adapter for vent connection G 1/4 to 1/4 NPT Part # 231944 G 1/2 to 1/2 NPT Part # 231945 c Size f a For Class I Regulators b is the total length of the regulator including OPD and fittings FRS 7../6 Class II Order No. Pressure max. [PSI] Size FRS 705/6 269319 5 NPT 1/2 2.9 75 FRS 707/6 269320 5 NPT 3/4 3.9 100 FRS 710/6 267006 5 NPT 1 4.3 110 FRS 712/6 267008 5 NPT 1 1/4 5.9 150 FRS 715/6 269323 5 NPT 1 1/2 5.9 150 FRS 720/6 267013 5 NPT 2 6.7 170 FRS 725/6 269326 5 NPT 2 1/2 9.1 230 FRS 730/6 269329 5 NPT 3 10.4 265 Dimensions [inch] Dimensions [mm] a b c d e f 4.5 115 5.1 130 5.7 145 7.7 195 7.7 195 11.2 285 11.2 285 0.9 24 1.1 28 1.3 6 1.6 1.6 1.9 47 3.7 95 3.7 95 5.6 143 6.5 165 7.5 190 12.2 310 15.9 5 15.9 5 G 1/4 8.9 225 G 1/4 9.6 245 G 1/4 12.2 310 G 1/2 14.2 365 G 1/2 14.2 365 G 1/2 17.7 450 G 1/2 23.2 590 G 1/2 23.2 590 Weight [lbs] [kg] 1.3 0,6 2.2 1,0 2.6 1,2 5.9 2,7 5.5 2,5 7.7 3,5 16.5 7,5 22.0 10,0 3 8

Lockup Rating Parameters Per ANSI Z21.80, lockup is defined as an outlet pressure not more than 150 % or 5 in. W.C,whichever is greater, above the setpoint after a downstream safety shutoff valve closes with 2 seconds, and the two following conditions exists: 1) outlet pressure is set to the highest set point of the spring, and 2) the regulator is set to maximum capacity or flow at which the regulator will control lockup pressure within the acceptable limits. This means that in a given application, a lockup greater than 150 % or 5 in. W.C could occur, depending out the inlet pressure, the outlet pressure of the regulator, the flow rate of the regulator, and the pipe volume downstream the regulator and upstream the safety shutoff valve. Per EN 881, lockup is +30 % of the outlet pressure setting after downstream shutoff valve slowly closes within 30 seconds. Therefore, in a given application, a lockup greater than +30 % or 5 in. W.C could occur, depending out the inlet pressure, the outlet pressure of the regulator, the flow rate of the regulator, and the pipe volume downstream the regulator and upstream the safety shutoff valve. If in a given application the Lockup pressure is too high, employing one or more of the following should reduce the lockup pressure: 1) increase the size of the regulator. 2) increase the pipe volume downstream the regulator and upstream the safety shutoff valve. 3) decrease the inlet pressure. 4) decrease the oulet pressure. 5) reduce the flow rate. Outlet Pressure Spring Selection (outlet pressure values are for horizontal pipe mounting) The output pressure is controlled by the force of the adjustable spring. The pressure regulator is supplied with the blue spring No. 4. By exchanging springs, other output pressures can be attained. Subtract 1 W.C. when mounted vertically. FRS 7../6 Type Order No. as Class I Regulator Outlet pressure range as Class I FRS 705/6 267002 4 12 in. W.C. 10 22 in. W.C. FRS 707/6 269320 4 12 in. W.C. 10 22 in. W.C. FRS 710/6 269321 4 12 in. W.C. 10 22 in. W.C. FRS 712/6 269322 4 12 in. W.C. 10 22 in. W.C. FRS 715/6 267010 4 12 in. W.C. 10 22 in. W.C. FRS 720/6 267012 4 12 in. W.C. 10 22 in. W.C. FRS 725/6 269325 4 12 in. W.C. 10 22 in. W.C. FRS 730/6 269328 4 12 in. W.C. 10 22 in. W.C. Monitoring Regulator as Overpressure Protection device. Outlet Pressure Protection Range FRS 7../6 Type Order No. as Class II FRS 705/6 269319 24 in. W.C. FRS 707/6 267004 24 in. W.C. FRS 710/6 267006 24 in. W.C. FRS 712/6 267008 24 in. W.C. FRS 715/6 269323 24 in. W.C. FRS 720/6 267013 24 in. W.C. FRS 725/6 269326 24 in. W.C. FRS 730/6 269329 24 in. W.C. Regulator Outlet pressure range as Class II 4 8

Pressure Taps FRS 7../6 Threaded Version 1 Vent/breather connection FRS 705/6 FRS 710/6, G 1/4 in. FRS 712/6 FRS 730/6, G 1/2 in. 2 External feedback pressure connection FRS 705/6 FRS 710/6, G 1/4 in. one side. FRS 712/6 FRS 730/6, G 1/4 in. both sides. 3 Upstream pressure connection FRS 705/6 FRS 710/6, 1/4 in. NPT one side. FRS 705/6 FRS 710/6, G 1/4 in. one side. FRS 712/6 FRS 730/6, 1/4 in. NPT both sides. 4 Downstream pressure connection FRS 705/6 FRS 710/6, 1/4 in. NPT one side. FRS 712/6 FRS 730/6 1/4 in. NPT both sides. FRS 7../6 sectional drawing regulator in operating position 1 Housing 2 Regulating cup 3 Internal feedback tube 4 Balancing diaphragm 5 Diaphragm disk 6 Atmospheric diaphragm 7 Vent limiter 8 Vent line connection 9 Setpoint spring 10 Adjustment device 10 9 8 7 6 5 Protect the pressure regulator from debris by using a suitable filter. p 1 p 2 4 3 2 1 Pressure drop for other gases To determine the pressure drop when using a gas other than natural gas, use the flow formula below and f value located in the table below to determine the corrected flow rate in CFH through the valve for the other gas used. For example, when using propane, divide the volume (CFH) of propane required for the application by the calculated value f (f = 0.66 for propane). Use this corrected flow rate and the flow curve on the next page to determine pressure drop for propane. Determining equivalent flow through valves using another gas f = V gas used = V Natural gas x f Density of Natural gas Density of gas used Type of gas Density [kg/m 3 ] s.g. Natural gas 0.81 0.65 1.00 Butane 2.39 1.95 0.58 Propane 1.86 1.50 0.66 Air 1.24 1.00 0.80 f 5 8

Mechanically Opened Curve Class II Regulator Pressure Drop Curve Pressure drop for a Class I regulator is in worst case twice the value of the Class II regulator. NPT 1/2 NPT 3/4 NPT 1 NPT 1 1/4 NPT 1 1/2 NPT 2 NPT 2 1/2 NPT 3 100 80 60 50 30 Pressure Drop (in. W.C.) 20 10 8 6 5 4 3 2 1 100 200 300 0 600 800 1000 2000 00 6000 10,000 20,000,000 60,000 100,000 Flow of Natural Gas (cubic feet/hr) 6 8

Flow Curve Using Natural Gas for class II regulator. Use as a quick reference for sizing a regulator in the regulated state at: Outlet pressure = 8 in. W.C. Inlet pressure = 20 in. W.C. Vmin = 0.05 x Vmax Flow tables for other outlet pressures are available Pressure drop for a Class I regulator is in worst case twice the value of the Class II regulator. Pressure Drop (in. W.C.) Operating Range Inlet Pressure 20 in. W.C. Outlet Pressure 8 in. W.C. Flow (CFH) of natural gas; s.p. 0.65 at 60 F 7 8

Line Pressure Regulators Class I or Class II FRS 7../6 Series We reserve the right to make any changes in the interest of technical progress. Karl Dungs, Inc. 3890 Pheasant Ridge Drive NE Suite 150 Blaine, MN 55449, U.S.A. Phone 763 5821700 Fax 763 5821799 email info@karldungsusa.com Internet http://www.dungs.com/usa/ Karl Dungs GmbH & Co. KG P.O. Box 12 29 D73602 Schorndorf, Germany Phone +49 (0)718180 Fax +49 (0)7181804166 email info@dungs.com Internet http://www.dungs.com 8 8