SCHEDULE-V-I SPECIFICATION OF FIRE PROXIMITY SUIT Srl. No TECHNICAL SPECIFICATION Complied Not Complied Deviation, if any Page No. at which Tech Literature attached (1) (2) (3) (4) (5) (6) 1 Fire Fighting Jacket:- 1)Fire Fighting Jacket is provided with FR Zipper (Hook & Loop) 2) Special features to be provided under the armpits for easy movement of arms. 3) FR Knitted round cuff material is provided at the wrist for firm fit and to ensure that heat is not transmitted through the wrists. 4)Two Strips of 2 FR Reflective trim is used at middle round and arms round of the jacket ensure high visibility and one additional strip at the bottom. 5)Two Pockets with flaps at the bottom Hip on both sides 6)The entire Jacket is stitched with inherent flame Retardant threads. 7) Double close front, Velcro fixing device and safety zipper. 8) Chest packet on the jackets installed with Radio Packets and Microphone brackets. 9) Front opening closed with dress zipper which is covered by a Velcro Sealed Plate. 10) Cuff can be adjusted by Velcro and with fire Proof, water Proof and thumb ring design. 11) 3m Reflective trims installed to enhance high visibility of fire fighters at work. 2 Fire Fighting trouser:- 1) Fire Fighting Pant is provided with one central fly zippers for easy wear and removal with comfort white wearing or removing. 2)The Zipper is concealed by a flap of the outer shell. 3)The Concealed FR Elastic is provided at the waist for firm fit.
4)Two Side thigh Pockets are provided for storing any important accessories. 5)The entire pant is held in place by adjustable FR suspenders. 6)An additional Layer of outer shell fabric is provided at the knee portion as on additional reinforcement to enhance the garment during kneeling or any such operation. 7. Two layer flapped packets in front and flapped below packet on each leg. 3 Anty Flash Hood:- 1) Anty lash hood made from Nomey R 111A knitted fabric. 2)The entrie Hood is double layered to ensure to proctect the fire man from any flash of head. 4 Fire Fighter Helmet:- 1)The helmet is made out of flame-retardant material. 2)The helmet is having flame retardant collapsible visor. 3)The helmet is having soft cushion head band and adjustment system to adjust the size of the helmet depending upon the wearer head size. 4)The helmet is having reflective stripe on the shell for high visibility. 5)The helmet is having extra detachable neck protection. 5 Fire Fighter Boot:- 1)The boot is made up of good quality flame retardant rubber material. 2)The boot is provided with metal tac cap. 3)The Boot is having good quality fire resistance bottom sole 6 Fire Fighter Gloves:- 1) Fire Fighter Gloves is made up of multi-layer assembly having outer layer as FR leather and middle Layer as moisture barrier and inner layer as thermal barrier and cut resistant lining. 2) The design of the gloves is fire finger type. 3)The Fire Fighter Gloves is having FR knit wrist for firm fit. 4)2 Reflective firm provided at back portion of palm for visibility.
SCHEDULE-V-2 SPECIFICATION OF LACHRYMATORY CRUSHING UNIT SL TECHNICAL SPECIFICATION COMPLIED NOT COMPLIED DEVIATION, IF ANY NO 1 IT SHOULD FLAME PROOF MOTOR 2 ALL CONTACT PARTS CAN EASILY BE DISMANTLED AND CLEANED ON THE BASIC OF REQUIREMENT 3 BREAKING OF CHEMICAL LACHRYMATORY COMPOSITION 4 FEED HOPPER a CAPACITY - 50 KG/HR b SIZE 600X 600 X 500 MM 5 ELECTRO MAGNETIC VIBRATORY FEEDER a CAPACITY - 50 KG/HR b TRAY SIZE 600 X 300 X 100 MM c SUPPLY VOLT SINGLE PHASE, 230 VAC, 50 Hz d FREQUENCY 50Hz e POWER 175 WATTS, 1 PHASE f VPM 2000 3000 VPM 6 DOUBLE ROLL CRUSHER a CAPACITY 50 KG/HR b TYPE SMOOTH ROLL c ROLL SIZE 300(DIA) X 400(W) MM d INPUT SIZE BELOW-15 MM PAGE NO, AT WHICH TECH LITERATURE IS PLACED
e OUTPUT SIZE - < 2MM f CAPACITY 50 KG/HR g CRUSHER ROLLER SPEED 36 RPM h DRIVE 36 RPM 2 X 2.2 KW, 3 PHASE, 415 V, 50 Hz i LINER ALUMINIUM WITH REDUCTION GEAR BOX 7 DISCHARGE CHUTE a CAPACITY - 50 KG/HR b LINER - ALUMINUM 8 COLLECTING BIN 50 KG/HR
SCHEDULE-V-3 SPECIFICATIONS OF PLASTIC PELLET SL NO SPECIFICATION COMPLIED NOT COMPLIED 1 Size-1200 mm (L)x 100 mm (W)x180 mm (H) + 5% 2 Material HDPE perforated deck 3 Loading bearing Capacity-- Static- Min. 3000 kg Dynamic- Min. 800 Kg 4 Should have IS Certification. 5 Should be Aesthetic DEVIATION IF ANY PAGE NO AT WHICH TECHNICAL LITERATURE IS PLACED
SCHEDULE-V-4 SPECIFICATION OF MEDICAL SPINE BOARD STRETCHER SL NO SPECIFICATION COMPLIED NOT COMPLIED 1 Length :2.2 Mtr 2 Width :1.0 Mtr 3 Material : Polyolefin 4 Thickness 3.0 mm 5 Colour : Golden Yellow 6 Retainstraips : 6 Straps Of 25 mm Polyester Webbing For Tightening The Stretcher With The Wounded Fully Secure In It. 7 Carry Handles : 4 Nos For Easy Transportation 8 Lifting Slings : 2 Nos For Lifting Or Lowering The Wounded In Horizontal Position. 9 Kern Mantle Rope : 9 Mtr Of Dia 10.5mm For Vertical Lifting Or Lowering 10 Weight : 5.5 Kgs 11 Metallic Assembly :Made Of Brass Therefore No Risk Of Corrosion. 12 Load Carrying Capacity :200 Kgs DEVIATION IF ANY PAGE NO AT WHICH TECHNICAL LITERATURE IS PLACED
SL NO SCHEDULE V-5 SPECIFICATIONS OF 510 KVA 3 PHASE OIL COOLED SERVO CONTROLLED MOTOR OPERATED LINE VOLTAGE CORRECTOR SPECIFICATION COMPLIED NOT DEVIATIO COMPLIED N IF ANY Item Value Unit 1 Phase 3 Phase 4 Wire 3 Phase System 2 Rated Capacity 510 KVA 3 Input Voltage Range 320-480 V V 4 Output Voltage Range 415 V V 5 Output Volt Precision + 1% (adjustable) +1% 6 Working Frequency 50 Hz + 5 Hz Hz 7 Efficiency 98 % % 8 Load Power Factor 0.8 to 0.90 9 Protection Requirement Yes 10 Meters Requirement Yes 11 Other Special 12 Insulation Class Oil Cooled servo Controlled Voltage Stabilizer 13 IP grade for cabinet Indoor 14 Application of Load Unbalanced (Where to use it, for which type of machine) 15 Approvals required ISO: 9815-1994 PAGE NO AT WHICH TECHNICAL LITERATURE IS PLACED
16 Packing Requirements Yes 17 Features a Individual phase voltage control b Auto/Manual Control c Digital display with selector switch for voltage & Ampere d High & Low Voltage Indicator / alarm/ hooter e Overload and short circuit protection by providing fuse unit at appropriate level
SCHEDULE V-6 SL NO. SPECIFICATIONS OF INDUSTRIAL VACUUM CLEANER SPECIFICATION COMPLIED NOT COMPLIED 1 Mopping machine should have provision to clean all types of floors 2 Machine should height adjustable operating handle and the adjustable brush drive(power flow) are idle for fatigue free operation 3 Motor of mopping machine should be of low noise level and flame proof motor 4 Clean water tank should capacity have between 20 to 25 Ltrs 5 Dirty water tank capacity should have between 20 to 25 Ltrs 6 Mopping machine should have brush pressure between 20 to 22 kg 7 Mopping Mac hine Shouyld have working speed up to 04 km/hrs 8 Mopping Machine should stainless/fiber tank (rust proof, shock proof and earth provided) 9 Mopping Machine should have arrangement to clean wet & dry dust surface 10 Tank should be emptied quickly and easily through outlet hose 11 Inlet (Power) Pressure - 6 bar DEVIATI ON IF ANY PAGE NO AT WHICH TECHNICAL LITERATURE IS PLACED
12 Min. air Consumption - 22I/s 13 Suggested air feed - 25I/s 14 Depressure (at 6 bar) - 29.4 kpa 15 Depressure (at 6 bar) - (3000 mm H2O 16 Airflow (at 6 bar) - 100 I/s 17 Tank Capacity - 1001-10.58 gal 18 Acuslic Pressure - 70 db(a) 19 Filteration Area - 15000 cm 2