High Performance Mass Spectrometers

Similar documents
Hiden QIC Series Gas Analysers Real-time gas analysis systems

Residual Gas Analysis Systems for Industry

Quadruple mass spectrometers (transducer type)

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Mass Spectrometers. for Gas Analysis GAS ANALYSIS

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Practical approach and problems in in-situ RGA calibration

Choosing a Quadrupole Gas Analyzer Application Note #9

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

PHOENIX L300i Best-in-class Helium Leak Detectors

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Determination of the Vacuum System for R2R by using a New Pumping Simulation Program

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

Go/no-go test for the acceptance of components for unbaked vacuum sectors

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

Larimax. Residual Gas Analysers and Gas Analysis Systems. Index. Low Cost PC Controlled RGA PC Controlled RGA for gas analysis

Total Pressure Measurement Using Residual Gas Analyzers

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

The Principles of Vacuum Technology

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

PRC CO ² -LASER PRESENTATION

Major Design Features

Resist round robin ELETTRA

835 VQM. Features & Benefits

The Helium Leak Detector

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Mass Spec will not Autotune

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

Standard Operating Manual

Gun Vacuum Performance Measurements February 2003

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

ISO/TC 112/WG 2 N 49. ISO TS QMS WD v6. Date of document Expected action Comment Due Date Background

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

The Broadest Gauging Line in the Industry

PRad Target. Chris Keith JLab Target Group

Review of the Hall B Gas System Hardware. George Jacobs

How much do customer returns cost you?

Oxford Instruments Austin, Inc.

Operating Procedures for the. SAMCO ICP RIE System

FPG8601 Force Balanced Piston Gauge

Digital Mass Flow Meters and Controllers for Gases

Additel 761 Automated Pressure Calibrators Selection Guide

Thermo K-Alpha XPS Standard Operating Procedure

Additel 761 Automated Pressure Calibrators Selection Guide

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

METHODS FOR IN SITU QMS CALIBRATION FOR PARTIAL PRESSURE AND COMPOSITIONAL ANALYSIS

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

Customer Responsibilities

COMPACT HIGH PERFORMANCE HELIUM LEAK DETECTORS ASM 182 SERIES

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ADDENDUM IMPORTANT DOCUMENT INVITATION TO BID ADDENDUM. OPENING DATE & TIME: January 3, 2018 at 3:00PM

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Positioner type Smart Valve Positioner with diagnostic functions. Presented By: Mr. Gourishankar Saharan. Product management Jens Bargon / V42

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

TECHNICAL DATA. Q = C v P S

MULTIPROBE. A Family of Multi-Technique UHV Surface Science Systems

Additel 761 Automated Pressure Calibrators

HumiSys HF High Flow RH Generator

Additel 761 Automated Pressure Calibrators

The instrument should have a mass range from 2 to 2000 m/z or better Interface

Mass Flow Controller (MFC) for Gases

VIC offers a variety of Calibrated Gas Leaks

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Plasma Asher: March PX-500 User guide (May-30, 2017)

Protec P3000 (XL) Helium Sniffer Leak Detector

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

March Asher Operation

SINGULUS TECHNOLOGIES

780S Ultra High Purity Series

High Va. High Vacuum Pumps. COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units

GA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No

Vacuum System at IUAC

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Convergent Technologys product overview

Detecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.

TECHNICAL DATA. Q = C v P S

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO

FURNACE N 2 DOPING TREATMENTS AT FERMILAB

Differential pressure

Transcription:

High Performance Mass Spectrometers For Vacuum and Semiconductor Process Monitoring

Detailed product information / introduction MOCVD semiconductor processing Applications: XXCVD/MOCVD XXPECVD XXALD XXSputtering XXVacuum coating XXPlasma etching XXMBE plasma etching Key Features XXRobustness and stability for permanent process monitoring XXVersatile systems for different process pressure ranges XXPrecision analyses of residual gases, detection limit to 2x10-15 mbar XXCustomised systems available XXCommunication interfaces for external data analysis in real time PC Software for process monitoring and control: irga MASsoft This newly developed LabVIEW -based software allows a very straightforward analysis of frequently observed residual gases. The visual interface displays measured partial pressures in real time and indicates critical parameters in colour code. Trips can be set to send alarms via the internal I/O system or to external devices. Hiden s MASsoft is a comprehensive software program giving access to trend view, histogram and peak profile modes. The user can set up scan sequences mixing the different modes and customising the scan parameters with additional statistical analysis functions available. RGA Tablet mode MASsoft Professional overview

Process and Residual Gas Analyser (HPR-30 system) Hiden s HPR-30 system is a gas analyser optimised for the analysis of gases and vapours in vacuum processes and vacuum diagnostics. XXDirect process analysis through the pressure range 10-4 mbar to 1 mbar and extendable to 1000 mbar XXUnique sampling probe orifice can be extended directly into the process region for optimised response and sensitivity XXSensitivity to 100 parts-per-billion as standard and 5 partsper-billion with optional triple stage mass filter XXIntegrated high conductance valve option for residual gas analysis at chamber pressures < 10-4 mbar XXPneumatic valve control option for automatic sampling operation with manual override and fail-safe interlock in case of over pressure or power failure XXMass range is 200 amu as standard with high mass range options to 300 amu, 510 amu and 1000 amu with triple stage mass filter Mobile pole-mounted HPR-30 with foreline pump at the base XXFlexible configuration options including pole-mounted/cart integrated systems providing a portable vacuum diagnostics platform that is readily utilized across multiple vacuum chambers and process tools SIM : torr 1e-06 TiN Deposition Cycles 1e-07 1e-08 1e-09 1e-10 0.00 1.00 2.00 3.00 4.00 Scan 1 : mass 28.00 Scan 2 : mass 32.00 Scan 3 : mass 44.00 Scan 4 : mass 40.00 Time mm:ss Scan 5 : mass 2.00 Scan 6 : mass 18.00 5.00 6.00 7.00 8.00 9.00 Scan 7 : mass 15.00 Scan 8 : mass 14.00 Scan 9 : mass 20.00 HPR-30 data from a TiN deposition process

Vacuum accessories and systems for RGA operation HMT High Pressure RGA Hiden s HMT RGA system is a unique dual mode RGA that operates as a conventional RGA for vacuum diagnostics and monitoring at pressures of less than 10-4 mbar and can switch into a high pressure mode for process analysis at pressures up to 5x10-3 mbar without a requirement for differential pumping or a sampling system. Key Features XXHMT mode for high pressure operation to 5x10-3 mbar XXRGA mode for high sensitivity operation to 2x10-13 mbar XX100 amu mass range XXstability better than +/- 1% over 24 hours XXfast access mixed mode scanning Vacuum process sampling Hiden offers vacuum sampling accessories and components that are available as bolt-on low cost modules or part of an integrated system. Vacuum accessories for process monitoring: XXSample lines and options for sampling over a range of process pressures XXRGA gauge housing with ports for vacuum pumping, pressure gauge and sampling line XXRGA gauge head sampling tube with aperture for sampling XXUHV turbomolecular pump system XXreal-time background subtraction HP-Faraday: torr 0.0012 HMT measurement (Ar) 0.001 0.0008 0.0006 0.0004 Chamber pressure (Torr) 0.0002 0 00.00 01.00 02.00 03.00 04.00 05.00 06.00 07.00 08.00 09.00 10.00 Time mm:ss Argon 1.80E-04 Chamber pressure vs Ar flow in chamber 1.60E-04 1.40E-04 Chamber pressure (Torr) 1.20E-04 1.00E-04 8.00E-05 6.00E-05 4.00E-05 2.00E-05 0.00E-05 0 5 10 15 20 25 Ar flow in chamber (sccm) HMT HMT Analyser measuring Argon in the process chamber

RGA - Residual Gas Analysis Faraday : torr 1.4e-08 1.2e-08 1e-08 8e-09 6e-09 4e-09 2e-09 0 0:00:00 2:00:00 4:00:00 6:00:00 8:00:00 Time hh : mm:ss Process analysis multiple species monitored over 8 hours XXQuadrupole mass spectrometers provide for fast sensitive measurement of all vacuum residuals from light elements, hydrogen and helium through to volatile organic species. XXThe RGA gauge head protection accessory is recommended for applications where the RGA can be used pre-process, placing the analyser out of the line of sight of potentially harmful condensing species and isolating it when the processing at higher pressures begins. XXHiden s range of residual gas analysers are based on high performance quadrupole mass spectrometers, and provide a unique window into the vacuum environment for contamination monitoring, leak detection, and for analysis of species of interest within the vacuum chamber. SEM : torr 1.8e-09 1.6e-09 1.4e-09 1.2e-09 1e-09 8e-10 6e-10 4e-10 RGA analyser gauge 2e-10 0 0 10 20 30 40 50 60 70 80 90 100 mass : amu Residual gas spectrum of a clean chamber at UHV RGA gauge head protection accessory a UHV housing with 90 degree elbow (RAH-9 housing).

Residual Gas Analysers for vacuum process monitoring ITEM DESCRIPTION PARTCODE Vacuum Process Sampling Systems HPR-30 HPR-30 CART HPR-30 Vacuum process sampling system, including HAL 201 RC mass spectrometer with Faraday and Electron Multiplier Detectors. Mass range 200 amu. Process pressure range for sampling: 1 mbar to 10-4 mbar. The sampling pressure range may be extended with special options. The HPR-30 system includes: XXRe-entrant probe with user changeable sampling orifice XXVacuum system all dry turbomolecular pump set with total pressure gauge and safety interlock for protection of the mass spectrometer in case of over pressure HPR-30 Vacuum process sampling system mounted on a compact mobile cart with flexible height adjustment for coupling to multiple chamber types 305300 305320 QC 2.1 Extended mass range to 300 amu with triple filter mass spectrometer 305021 QC 2.2 Extended mass range to 510 amu with triple filter mass spectrometer 301200 QA 1.0 Extended mass range to 1000 amu with triple filter mass spectrometer 301300 LKV-30 Extended sampling pressure range up to 1000 mbar Process sampling leak valve with flexible stainless steel bellows and DN-35-CF flanged coupling 305325 VS 3.3 Pneumatic valve option with automatic control module 303603 Vacuum Process Sampling Accessories And Components RAH-9 RGA analyser housing with 90 elbow 202110 HTM HPR-30 UHV Manifold bakeout heater set 303330 VPA-1 VPA-2 1 m long sampling line for optimum conductance for sampling the pressure regime: 10-4 mbar to 10-2 mbar 2 m long sampling line for optimum conductance for sampling the pressure regime: 10-2 mbar to 1 mbar 303331 303332

Dimensions in mm HPR-30 Cart ITEM DESCRIPTION PARTCODE High Pressure Residual Gas Analysers HMT 100 High pressure RGA system 100 amu Faraday Detector Minimum detectable partial pressure 2x10-11 mbar Maximum operating pressure 5x10-3 mbar 151100 HMT 101 High pressure RGA system 100 amu Faraday and Electron Multiplier Detector Minimum detectable partial pressure 2x10-13 mbar Maximum operating pressure 5x10-3 mbar 151101 Residual Gas Analysers HAL0 100 RC RGA sytem 100 amu Faraday Detector Minimum detectable partial pressure 2x10-11 mbar Maximum operating pressure 1x10-4 mbar 141100 HAL 201 RC RGA sytem 200 amu Faraday and Electron Multiplier Detector Minimum detectable partial pressure 5x10-14 mbar Maximum operating pressure 1x10-4 mbar 144100

Hiden s quadrupole mass spectrometer systems address a broad application range in: GAS ANALYSIS dynamic measurement of reaction gas streams catalysis and thermal analysis molecular beam studies dissolved species probes fermentation, environmental and ecological studies SURFACE ANALYSIS UHV TPD SIMS end point detection in ion beam etch elemental imaging 3D mapping PLASMA DIAGNOSTICS plasma source characterisation etch and deposition process reaction kinetic studies analysis of neutral and radical species Hiden Analytical Ltd. 420 Europa Boulevard Warrington WA5 7UN England T +44 [0] 1925 445 225 F +44 [0] 1925 416 518 E info@hiden.co.uk W www.hidenanalytical.com VACUUM ANALYSIS partial pressure measurement and control of process gases reactive sputter process control vacuum diagnostics vacuum coating process monitoring Sales Offices: We have sales offices situated around the globe. Visit our website for further information. TDS 144/1