OHD Quantifit Training

Similar documents
QUANTIFIT....the gold standard in respirator fit testing. Product Information Brochure

Instructions for using TSI Model mm or 8025-CEN Fit Test Adapter Kit

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Don t Forget About Fit What You Need to Know About Respirator Fit-testing

Respiratory Protection Program

MMR Air Mask With. with Quick-Connect Hose

Section1. Knowledge of RPE Sets out the minimum knowledge requirements in respect of respiratory protective equipment. [Mandatory] 1.

RESFT 101 Intro to Quantitative Fit Testing

Model 6202 Reduced Oxygen Breathing Device 2

Installation Instructions

Installation Instructions

Respiratory Protection. Program

VINAYAK PHARMA TECHNOLOGY

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Respirator Fit Testing and Respirator Fit Testers. Operation and Service Manual

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Performance Examination 4100 Sub JAC Handbook

Installation Instructions

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Alpha Solway Ltd. Respiratory Qualitative Face Fit Test Kit - QLTK1

Donning Personal Protective Equipment

European Technical Standard Order (ETSO)

Dräger X-plore 3500 Half Mask

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

3M Full Facepiece 6000 Series and 3M Continuous Flow Supplied Air Respirator System Dual Airline Introduction

Device overview. 6 Breathing circuit connection. Note: When the remote control foot pedal is connected, the manual switch is disabled.

Product Information News

A. Evaluation of the written program

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

One Mask. Countless Possibilities. [ Introducing the new Advantage 4000 Facepiece ]

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

Vortex Tube Respirator

Barry Sanders has the following disclosures to make:

[MSA The Safety Company] TURBO-FLO. Blowers. Replacement Parts. Accessories. Masks. Exploded Diagrams. safetyscope. Product Portfolio for FABA

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

"RESPIRATORY PROTECTION AND SAFETY"

ST53SD. Self Contained Breathing Apparatus. User Manual

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

Phalanx Alpha Phalanx Beta and Ultra Elite

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

Section 1: Overview... 6 Features... 6 Supported Software Part 1: Getting Started 7

N95 Respirator Fit-testers Training. UMDNJ Office of Environmental Health & Safety Services (EOHSS)

Installing ASI Umbilical Delivery Systems

Pressure Dump Valve Service Kit for Series 3000 Units

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

BIOPAK 240R MAINTENANCE TOOL KIT. TOOL KIT PART NUMBER: B Revision A

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

RESPIRATORS & FIT TESTING

Checklist for care of Respirators

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

FIRE FIGHTER I EMERGENCY PROCEDURES WHEN USING SCBA TOPIC: TIME FRAME: 0:30. Level II LEVEL OF INSTRUCTION:

A COMPARISON STUDY OF THE OVERALL FIT FACTORS BETWEEN THE PORTACOUNT AND THE FIT TESTER Jeff Funke. A thesis submitted to the

HOW TO USE A RESPIRATOR

NIOSH Task Number 18388

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

BioPak 240 Revolution

RK-IR Sample Draw Aspirator Adapter Operator s Manual

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

Focus Area Campaign for November 2014 SCBA

Welding Safety & Health RESPIRATORY PROTECTION

Respiratory Protection for Producers

PPE Refresher Using your SCBA

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

The McHenry Township Fire Protection District (MTFPD) invites interested and qualified parties to submit a request for proposal for SCBA.

BioPak 240 Revolution

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

RESPIRATORY PROTECTION PROGRAM

Training. Level of training on the Scott 4.5 SCBA air pack must be completed in the order stated on the pages below.

Using a Filtering Facepiece Respirator

Respiratory Protection

Service and Repair Manual

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

Double Emulsion Droplet generation and collection protocol Version Author Date Reviewer Change 1 Introduction

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

MASSACHUSETTS STATE POLICE CRIME LABORATORY. Certificate of Calibration Procedure for the Alcotest 9510

Chromat Calibration Updated October 27th, 2017

Mirage Vista Nasal Mask

ETT Olfactometer: Getting started guide 2013a. ETT Olfactometer quick start

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

stormrider Instructions for Use Version 08/2017

PAPR Flow Tester. instructions. part no WARNING

Installation Instructions

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Combination Breathing Apparatus

Respiratory Protection Training

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

The Walkstation. User Instructions. FitWork Walkstation

Grayslake Fire Protection District Request for Self-Contained Breathing Apparatus (SCBA) Bid

Respiratory Protection Program 29CFR

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Transcription:

OHD Quantifit Training

This training does not supersede users reading product information and manuals that are received with these products. Be sure to consult your department or organizational guidelines in the operation of these products.

Objectives: o Understand Quantifit and its components o Understand the approved Protocol & CNP o Understand test performance o Overview of troubleshooting issues o Overview of FitTrack Gold Software

Quantifit Fit Tester: o No Alcohol o Self sufficient (if necessary) o Control Panel o Ports Overview

Power Supply: o Locking Collar

Triple Tubes: Connects to Front Ports Connects to Adapter & Rear Ports

Trigger Response Button: o Initiates testing process

Adapter: o Adapter will vary based upon mask style. o Pictured below: Kit 1 40mm adapter

Additional Components o Keyboard o Carrying Case o Software CD-ROM o Training Video CD-ROM o User Manual

Overview: o Written into Federal Register 1910.134 Appendix A in September of 2004 o Utilizes Controlled Negative Pressure (CNP) o 5 tests, each 8-9 seconds long o Complete test can be performed in as little as 2-3 minutes. o Proven scientific accuracy

Controlled Negative Pressure (CNP) o Creating Negative Pressure Quantifit removes air from the mask and establishes and maintains a slight pressure. o Maintain Negative Pressure The negative pressure, or challenge pressure, is held constant by removing any air that leaks into the respirator. o Measure the Leakage The amount of air removed to keep the pressure constant is equal to the amount of air that is leaking into the respirator.

Computation of Fit Factor o Breathing Rate (BR) expressed in L/Min o Leak Rate (LR) expressed in cc/min o Fit Factor = Breathing Rate / Leak Rate OSHA Required Fit Factors o Full Face 500 o Half Face 100

REDON Protocol: Step 1 o Face Forward: stand and breathe normally. Face forward while holding breath for measurement.

REDON Protocol: Step 2 o Bend Over: bend at the waist, as if to touch your toes. Face parallel to the floor, while holding breath for measurement.

REDON Protocol: Step 3 o Shake Head: For about three seconds, shake head back and forth vigorously several times while shouting. Stop and face forward while holding breath for measurement.

REDON Protocol: Step 4 o Re-don, 1: Remove the respirator mask, loosen all facepiece straps, and then re-don the respirator mask. Face forward while holding breath for measurement.

REDON Protocol: Step 5 o Re-don, 2: Remove the respirator mask, loosen all facepiece straps, and then re-don the respirator mask. Face forward while holding breath for measurement.

Requirements: Clean shaven, no facial hair coming in contact with the seal Valid medical clearance to don a respirator

Daily Calibration: Initial Start-Up **Read ALL Prompts Before Proceeding.**

Daily Calibration: Zero Sensors **Read ALL Prompts Before Proceeding.**

Daily Calibration: Connect Dual Tubes **Read ALL Prompts Before Proceeding.**

Daily Calibration: Successful Disconnect tubes from the back

Data Entry Personnel ID First Name Last Name Job Code/Title Test Operator Name **Mask Size/Style **Proper Protocol Selected

Test Preparation: Test Protocol o Re-Don Protocol: recommended for Scott M110, MSA Millennium, and similar style masks o SCBA Protocol: recommended for Scott AV2000/AV3000 and similar style masks

Test Preparation: Inhalation Valves o Inhalation valves must be propped open Allows air to be evacuated Make sure gaskets remain in place

Test Preparation: Adapter o Attach fit test adapter to mask o Connect tubing Clear tubes connect to the twin plugs Blue tube connects to the single tube inline with the adapter gasket

Subject Instructions: o Breathing Take a normal breath Lips closed Hold breath for 8-10 seconds o Posture Remain still No swallowing or chewing

Five Step Fit Test: 8 Seconds Per Test 1. Face Forward run step 2. Bend at the Waist run step 3. Shake Head Shake head, stop, face forward run step 4. Redon 1 Remove mask, redon, face forward run step 5. Redon 2 Remove mask, redon, face forward run step

Operator Instructions: o Press and hold trigger button for duration of each 8 o o o o second test Once 8 seconds has lapsed and Quantifit has exhausted, direct subject to breathe normally and release trigger button Results are saved after a step passes When a pass occurs Quantifit will advance to the next step If a step fails (or is aborted) you will be prompted to save or retry

Common Challenges: o Subject not following instructions: Subject movement Subject opening mouth, swallowing, etc. Subject not keeping mouth closed Subject distracted (nervous, distracted, sabotage, not following directions)

Common Challenges: o Involuntary subject issues: Coughing, hiccups, etc. Nasal air leakage (nose-clips)

Common Challenges: o Mask Donning and Placement Issues: Mask not centered on the head Mask sized incorrectly Hair trapped in the seal Sunken temple Visible facial scars Facepiece not donned properly Facepiece straps worn, stretched or not tightened down sufficiently

Competency Skills, Main Takeaway 1. Set-up Quantifit 2. Daily Calibration 3. Data-entry 4. Conduct a Fit Test

Overview: o o o o o o Updated Interface: Dashboard Comprehensive Security Settings Firmware Upgrades Directly Through Software Customizable Reporting Synchronizing With Other Databases Importing / Exporting Data o Lets Try It!