PH300 Fresh powder hopper

Similar documents
OptiAir CA09 Pneumaticfluidizing

Pneumatic-fluidizing unit OptiAir CA12

OptiSpray AP01.1 Application Pump

Squeegee Unit for MRS Multi-Recovery System

Pressure maintenance valve SDV-P / SDV-P-E

MoveRoll Conveyor Operating and Maintenance Manual

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Operating and maintenance manual Filter and reducing station Series / 1.0

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Safety Powder Spray Systems

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Operating Instructions in accordance with the Machines Directive 2006/42/EC

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

original operating manual Operating manual TankQuick 100 F2 Translation of the Item-No.:

Budget Range Operators Handbook

A17W49_MASEM_F_EN MANUAL

For parts and technical support, call your nearest Finishing Customer Support Centre. Find your nearest centre at

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

PRAHER PLC-MP AQUASTAR MANAUL 2009

Operating instructions

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Tribomatic II Powder Pump

[Graphic Division] 10

OPERATION MANUAL PNEUMATIC VALVES

MAINTENANCE AND OPERATING MANUAL

Operating Instructions - Rescue Equipment. RAM Support LRS-T EN Edition (translation of the original operating instructions)

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

RTD Temperature sensor TH11

1. CONDITIONS FOR USE 2. SAFETY

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

VERTICAL AIR COMPRESSORS

Operating instructions

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Siphon vessel / Priming aid

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

neska High-Speed Handpiece P320

STAGE, STADIUM & X-TREME SHOT.

Pilot Check Valve: Metal Body Type

Installation, Operating & Maintenance Instructions. All-metal gate valve with extended pneumatic actuator. Series 48 DN mm (I.D.

HAMA H V compressor

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

Type BBS-03, BBS-05, BBS-06, BBS-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

Pneumatic spool valve islands

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

RH800 & 2000 BASIC OPERATIONS

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Flexi-pro Aerosol Delivery System (FADS) Manual

80 Litre Suction Oil Drainer

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Electro-Pneumatic Converter YT-940 SERIES

Table of Contents Documentation for PIT TROLLEY A4

Pressure Dump Valve Service Kit for Series 2300 Units

ENGLISH. Customer Product Manual Part P/N Transfer pump High-density powder

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Pressure Dump Valve Service Kit for Series 3000 Units

These operating instructions apply to: PKL 190 PKL 2100 PKL 450 PKL 5000 PKL 740 PKL 10000

OPERATION MANUAL NTF-15

SILENTAIRE TECHNOLOGY

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Installation and Operating Instructions Bypass Flow Meter DST

OPERATING INSTRUCTIONS

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Installation and commissioning instructions 255 series and 256 series

OPERATION MANUAL NTF-60 Plus

INTENDED USE TECHNICAL SPECIFICATIONS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating. Airgun

Actuating elements for ComEx

INSTALLATION GUIDE Gas Rangetops

Operating Instructions

Semi-bulk packaging for fine-particle SIPERNAT products. Technical Information 1321

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

SC6H OIL-LESS AIR COMPRESSOR

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Safety instructions and operating manual

Model 130M Pneumatic Controller

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Transcription:

En Operating instructions and spare parts list PH300 Fresh powder hopper Translation of the original operating instructions

Documentation PH300 Copyright 2008 Gema Switzerland GmbH All rights reserved. This publication is protected by copyright. Unauthorized copying is prohibited by law. No part of this publication may be reproduced, photocopied, translated, stored on a retrieval system or transmitted in any form or by any means for any purpose, neither as a whole nor partially, without the express written consent of Gema Switzerland GmbH. MagicCompact, MagicCylinder, MagicPlus, MagicControl, OptiFlex, OptiControl, OptiGun, OptiSelect, OptiStar and SuperCorona are registered trademarks of Gema Switzerland GmbH. OptiFlow, OptiCenter, OptiMove, OptiSpeeder, OptiFeed, OptiSpray, OptiSieve, OptiAir, OptiPlus, OptiMaster, MultiTronic, EquiFlow, Precise Charge Control (PCC), Smart Inline Technology (SIT) and Digital Valve Control (DVC) are trademarks of Gema Switzerland GmbH. All other product names are trademarks or registered trademarks of their respective holders. Reference is made in this manual to different trademarks or registered trademarks. Such references do not mean that the manufacturers concerned approve of or are bound in any form by this manual. We have endeavored to retain the preferred spelling of the trademarks, and registered trademarks of the copyright holders. To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of publication. Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice. For the latest information about Gema products, visit www.gemapowdercoating.com. For patent information, see www.gemapowdercoating.com/patents or www.gemapowdercoating.us/patents. Printed in Switzerland Gema Switzerland GmbH Mövenstrasse 17 9015 St.Gallen Switzerland Phone: +41-71-313 83 00 Fax.: +41-71-313 83 83 E-Mail: info@gema.eu.com

Table of contents General safety regulations 3 Safety symbols (pictograms)... 3 Proper use... 3 Product specific security regulations... 4 General information... 4 Installation... 5 Grounding... 5 Repairs... 5 About this manual 7 General information... 7 Product description 9 Field of application... 9 Utilization... 9 Reasonably foreseeable misuse... 9 Technical data... 10 Powder transport... 10 Electrical data... 10 Pneumatic data... 10 Dimensions... 10 Processible powders... 10 Sound pressure level... 11 Rating plate... 11 Design and function... 13 General view... 13 Compressed air indicators... 14 Feed Control Hood... 15 Principle of function... 16 Commissioning 17 Set-up and assembly... 17 Preparation for start-up... 17 Compressed air supply... 17 Grounding of the fresh powder hopper... 18 Coating operation 19 Before switching on... 19 Start up with the single control... 19 Start up with the main control... 20 Cleaning 21 Setting values 23 Compressed air... 23 PH300 Table of contents 1

Fault localization 25 General information... 25 Maintenance 27 Monitoring during operation... 27 Daily maintenance... 27 Additional monthly maintenance work... 27 Decommissioning, storage 29 Introduction... 29 Safety rules... 29 Requirements on personnel carrying out the work... 29 Storage conditions... 29 Storage duration... 29 Space requirements... 29 Physical requirements... 29 Hazard notes... 30 Shut-down... 30 Decommissioning... 30 Cleaning... 30 Disassembly/attachment of transport safety devices... 30 Packing... 30 Identification... 30 Maintenance during storage... 30 Maintenance schedule... 30 Maintenance works... 30 Return to service... 30 Commissioning following storage... 30 Packing, transport 31 Introduction... 31 Safety rules... 31 Requirements on personnel carrying out the work... 31 Packing material... 31 Transport... 31 Data concerning goods to be transported... 31 Mode of transportation... 32 Loading, transferring the load, unloading... 32 Spare parts list 33 Ordering spare parts... 33 PH300 Fresh powder hopper... 34 Pneumatic unit PH300... 35 Fluidized hopper PH300... 36 2 Table of contents PH300

General safety regulations Safety symbols (pictograms) This chapter sets out the fundamental safety regulations that must be followed by the user and third parties using the PH300. These safety regulations must be read and understood before the PH300 is put into operation. The following warnings with their meanings can be found in the Gema Switzerland operating instructions. The general safety precautions must also be followed as well as the regulations in the operating instructions. DANGER! Danger due to electrically live or moving parts. Possible consequences: death or serious injury WARNING! Improper use of the equipment could damage the machine or cause it to malfunction. Possible consequences: minor injuries or damage to equipment INFORMATION! Useful tips and other information Proper use 1. The PH300 is built to the latest specification and conforms to the recognized technical safety regulations and is designed for the normal application of powder coating. 2. Any other use is considered non-compliant. The manufacturer shall not be liable for damage resulting from such use; the user bears sole responsibility for such actions. Gema Switzerland GmbH must be consulted prior to any use of the PH300 for any purposes or substances other than those indicated in our guidelines. 3. Observance of the operating, service and maintenance instructions specified by the manufacturer is also part of conformity of use. The PH300 should only be used, maintained PH300 General safety regulations 3

and started up by trained personnel, who are informed about and are familiar with the possible hazards involved. 4. Start-up (i.e. the execution of intended operational tasks) is forbidden until it has been established that the PH300 has been set up and wired according to the guidelines for machinery (2006/42 EC). EN 60204-1 (machine safety) must also be observed. 5. Unauthorized modifications to the PH300 exempt the manufacturer from any liability from resulting damage. 6. The relevant accident prevention regulations, as well as other generally recognized safety regulations, occupational health and structural regulations are to be observed. 7. Furthermore, the country-specific safety regulations also must be observed. Explosion protection II 3 D Protection type IP54 Product specific security regulations General information The PH300 fresh powder hopper unit is a constituent part of the equipment and is therefore integrated in the system's safety concept. If it is to be used in a manner outside the scope of the safety concept, then corresponding measures must be taken. NOTE: For further information, see the more detailed Gema safety regulations! 4 General safety regulations PH300

Installation Installation work to be done by the customer must be carried out according to local safety regulations. Grounding The fresh powder hopper grounding is to be checked at every start-up. The grounding connection is customer specific and is fitted on the booth base, on the cyclone and on the powder management center. The grounding of the workpieces and other plant units must also be checked. Repairs Repairs must be carried out by trained personnel only. Unauthorized conversions and modifications can lead to injuries and damage to the equipment. The Gema Switzerland GmbH guarantee would no longer be valid. NOTE: We point out that the customer himself is responsible for the safe operation of the equipment! Gema Switzerland GmbH is in no way responsible for any resulting damage. By carrying out repairs, the fresh powder hopper must be disconnected from the mains, according to the local safety regulations! NOTE: Only original Gema spare parts should be used! The use of spare parts from other manufacturers will invalidate the Gema guarantee conditions! PH300 General safety regulations 5

About this manual General information This operating manual contains all important information which you require for the working with the PH300. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system. Information about the function mode of the individual system components - booth, axis, gun control unit, powder gun or powder injector - should be referenced to their enclosed corresponding documents. DANGER: Working without operating instructions Working without operating instructions or with individual pages from the operating instructions may result in damage to property and personal injury if relevant safety information is not observed. Before working with the device, organize the required documents and read the section "Safety regulations". Work should only be carried out in accordance with the instructions of the relevant documents. Always work with the complete original document. PH300 About this manual 7

Product description Field of application The PH 300 fresh powder hopper serves to continually supply powder to the coating plant. Utilization The PH300 fresh powder hopper is suitable for use in single color plants. As a part of the process controlled coating plant, the fresh powder hopper is laid out for semi-automatic operation. Reasonably foreseeable misuse - Use of moist powder - Insufficient fluidization - Operation without the proper training PH300 Product description 9

Technical data Powder transport PH300 Conveying performance Electrical data PH300 Connected load Frequency Protection type Pneumatic data PH300 Input pressure Compressed air consumption: - Fluidization - Conveying - Ventilation Water vapor content of compressed air Oil content of compressed air 6 kg/min. 1x230 V 50/60 Hz IP54 min. 6,5 / max. 10 bar approx. 40 Nm³/h approx. 11 Nm³/h approx. 2.5 Nm³/h max. 1.3 g/m³ max. 0.1 mg/m³ Dimensions PH300 Base area (width x depth) (mm) 1230 x 1210 Overall height (mm) 1500 Weight (kg) approx. 185 (with two PP06 pumps) Processible powders PH300 Plastic powder Metallic powder Enamel powder yes yes (bonded powders only) no 10 Product description PH300

Sound pressure level PH300 Normal operation Cleaning operation mode < 55 db(a) < 67 db(a) The sound pressure level was measured while the unit was in operation; measurements were taken at the most frequent operator positions and at a height of 1.7 m from the ground. The specified value is applicable only for the fresh powder hopper itself and does not take into account external noise sources or cleaning impulses. The sound pressure level may vary, depending on the powder management center configuration and space constraints. Rating plate NOTE: Fields with a gray background contain contract-specific data! PH300 Product description 11

Design and function General view 7 6 5 1 4 2 3 PH300 structure 1 Powder pump 5 Powder filling cover 2 Fluidizing plate 6 Ventilation 3 Fluidized hopper 7 Pneumatic unit 4 Feed Control Hood PH300 Product description 13

Compressed air indicators DR1 DR2 DR1 DR2 Powder container fluidizing air Compressed air input 14 Product description PH300

Feed Control Hood The PH 300 Powder Hopper has a powder outlet in the fluidizing plate with a Dense Phase Conveyor. If the powder hopper is switched off directly after conveying, the still fluidized powder flows into the opening into the Dense Phase Conveyor. At the next 'restart' this can lead to clogging, so that the conveyor hose must be emptied first. In order to prevent this problem, this feed control hood is fitted in the outlet opening. A ring slot around the outlet opening is created by the hood, so that powder can only flow slightly. The ring slot setting is, however, very much dependent on the flow characteristics of the powder and must, therefore, be set individually. Because the Feed Control Hood is only a push fit, it can be removed for setting or cleaning. PH300 Product description 15

Principle of function The PH 300 fresh powder hopper serves to continually supply powder to the coating plant. The hopper is fitted with a fluidizing plate, as well as with a Powder transport. As soon as the coating plant is put into operation, the powder hopper is supplied with compressed air. The ventilation switches on to vent the hopper. The powder hopper is filled manually with powder, preferably from 25 kg powder bags. The large surface platform on the hopper for the powder bag, and the inclined filler plate serve the simple, and dust-free filling of the hoppers. Resulting dust is sucked up by the ventilation and can be fed back into the booth or the powder recovery. Because of additional dust development it is not recommended to refill during transport cycles. If powder is now requested through the level sensor of the powder hopper, the fluidizing air, and the powder pump(s) are switched on. The powder is moved to the powder hopper, as long as the level sensor still requests powder. The fresh powder hopper is not equipped with level monitoring, as the level sensor in the powder hopper releases a booth alarm as long as the correct powder level is not reached within the specified time. 16 Product description PH300

Commissioning Set-up and assembly NOTE: Installation work to be done by the customer must be carried out according to local safety regulations! WARNING: The fresh powder hopper must only be installed in locations with an ambient temperature of between +20 and +40 C, i.e. never next to heat sources (such as an enameling furnace) or electromagnetic sources (such as a control cabinet). - All hose connections should be as short as possible. - The venting hose should be laid out without loops so that depositing, and clogging are prevented. - Check the hose connections for a good seal, and firm seating - Check the interlocking, so that the fresh powder hopper only works when the exhaust system is switched on. Preparation for start-up Compressed air supply NOTE: The compressed air must be free of oil and water! The fresh powder hopper requires a connection to a sufficient dimensioned compressed air circuit. In order to ensure a perfect operation, a pressure of 6 bar must be adjusted with the main pressure regulator. PH300 Commissioning 17

Compressed air supply Grounding of the fresh powder hopper DANGER: The fresh powder hopper must be grounded according to the general, local safety regulations. The grounding of the fresh powder hopper must be checked regularly. A corresponding connection point at the fresh powder hopper is reserved for the grounding. Grounding connection 18 Commissioning PH300

Coating operation Before switching on Before switching on the fresh powder hopper, the following points must be observed: - Observe the safety regulations - Check the grounding of the fresh powder hopper, the booth and the other plant units and ensure it, if necessary - Check the compressed air supply Start up with the single control The start-up takes place according the following steps: 1. Turn the main switch of the control unit to ON 2. Switch on the exhaust system - With this step the compressed air must also switch on and the pressure gauge on the control must display the following reference values: Conveying air: approx. 1.5 bar Valve pressure: approx. 2 bar Fluidizing air: approx. 2-3 bar Airmover: approx. 2.5-3.5 bar 3. Fill in powder - Because of additional dust development it is not recommended to refill the fresh powder hopper during a transport cycle. 4. The PH300 fresh powder hopper is ready for operation - When powder is requested through the level sensor in the powder hopper, a conveying cycle is released. 5. Switching off the exhaust system also automatically switches off the PH300 fresh powder hopper. PH300 Coating operation 19

Start up with the main control The start-up takes place according the following steps: 1. Turn the main switch of the booth control unit to ON 2. Switch on the control with key switch. 3. Switch on the plant 4. The exhaust air system is switched on - With this step the compressed air must also switch on and the pressure gauge on the booth control must display the following reference values: Conveying air: approx. 1.5 bar Valve pressure: approx. 2 bar Fluidizing air: approx. 2-3 bar Airmover: approx. 2.5-3.5 bar 5. Fill in powder - Because of additional dust development it is not recommended to refill the fresh powder hopper during a transport cycle. 6. The PH300 fresh powder hopper is ready for operation 7. Switching off the plant also automatically switches off the PH300 fresh powder hopper. 20 Coating operation PH300

Cleaning WARNING: If no dust mask or one of an insufficient filter class is worn when cleaning the fresh powder hopper, then the dust that is stirred up from the coating powder can cause respiratory problems. The ventilation system must be turned on for all cleaning work. A dust mask corresponding to filter class FFP2 or N95 at minimum must be worn during any cleaning work. WARNING: If no safety glasses are worn when cleaning the fresh powder hopper, then the dust that is stirred up from the coating powder can cause eye irritations. Safety glasses must be worn during any cleaning work! PH300 Cleaning 21

Setting values Setting values are reference values, and must be set according to operational experience. Compressed air PH300 Conveying air Pinch valve pressure Airmover Fluidizing air 1,5 bar 2 bar (must not be increased because a higher pressure will lead to damage of the sleeves) 2.5-3.5 bar 2-3 bar PH300 Setting values 23

Fault localization General information The causes of these errors must be eliminated, before further procedures are carried out. Always check the following points first when there are faults in the fresh powder supply: - Is Mains voltage present? - Is compressed air present (min. 4 bar)? Fault Powder discharges from the fresh powder hopper conveying performance too low Conveying runs continuously Error/solution - Too little air pressure at the Airmover - Venting hose clogged - Heavy sintering in the Airmover - Fluidizing in the fresh powder hopper not switched on - Too little fluidizing air - Powder pump defect - Control incorrectly set PH300 Fault localization 25

Maintenance Monitoring during operation - Check the compressed air: Displays on the pressure gauges remain the same. Daily maintenance - Check the compressed air: Displays on the pressure gauges correspond exactly with the values set - Transport hose: Check for sintering on the inside - Transport hose connection: Check for sintering on the inside - Airmover: Check for sintering - Venting hose: Blow out, and check for sintering Additional monthly maintenance work - Intermediate hopper - Check for sintering on the inside - Check the fluidizing plate PH300 Maintenance 27

Decommissioning, storage Introduction Storage conditions Safety rules Suitable equipment (e.g. a crane) must be used when moving parts that are sometimes bulky and heavy. Components being disassembled must be adequately secured before they are detached. Requirements on personnel carrying out the work Use only technical personnel who are trained in operating the respective equipment (e.g. a crane). If there are any uncertainties, please contact Gema. Storage duration If the physical conditions for metal parts and electronics are maintained, the unit can be stored indefinitely. On the other hand, the installed elastomeric components (pinch valve collars, O-ring seals, etc.) can become brittle over time and crack when put under repeated loads. Space requirements The space requirements correspond to the size of the fresh powder hopper. The load-bearing capacity of the floor should be at least 200 kg/m². There are no special requirements concerning distance to neighboring equipment. Physical requirements Storage must be inside a dry building at a temperature between +5 and +40 C. Preferably in a cool, dry and dark space. Do not expose to direct sunlight. PH300 Decommissioning, storage 29

Hazard notes There is no danger to personnel or the environment if the unit is stored properly. Shut-down Decommissioning Before starting any kind of work, the fresh powder hopper must be disconnected from the compressed air supply. - Relieve pneumatic pressure on the system - Unplug the power cable - Unplug the ground cable - Empty the powder container (see "Cleaning") Cleaning The complete fresh powder hopper is to be cleaned according to the instructions in the operating manual. Disassembly/attachment of transport safety devices - Fasten the powder container cover Packing It is recommended that the fresh powder hopper is placed on a dimensionally stable, adequately large palette using a forklift truck with long forks. To prevent damage to the components, collisions with other parts must be prevented. Identification Apply the label "Protect from dampness and moisture" on the product and the packaging. Maintenance during storage Maintenance schedule No maintenance schedule is necessary. Maintenance works During long-term storage, periodically perform a visual check. Return to service Commissioning following storage Following storage of more than 3 years, the rubber components must be checked and replaced if necessary. 30 Decommissioning, storage PH300

Packing, transport Introduction Packing material This chapter describes special precautions that must be taken during internal transport of the product if: or - the customer himself must pack, transport and ship the product, such as to have renovations or service work carried out by the manufacturer - the product must be shipped for disposal (recycling). Safety rules Suitable equipment (e.g. a crane) must be used when moving parts that are sometimes bulky and heavy. Components being disassembled must be adequately secured before they are detached. Requirements on personnel carrying out the work Use only technical personnel who are trained in operating the respective equipment (e.g. a crane). If there are any uncertainties, please contact Gema. A suitably stable pallet must be used. Transport Data concerning goods to be transported - The space requirements correspond to the size of the components plus the packaging - Weight see "Technical Data" - Points of attachment, see "Mode of transportation" PH300 Packing, transport 31

Mode of transportation For short distances/shifts of position within the same room, parts for the booth must be transported using a forklift truck with long forks or a crane. Transport the unit only in the position according to its intended use. Loading, transferring the load, unloading Suitable lifting equipment is to be used for all procedures. 32 Packing, transport PH300

Spare parts list Ordering spare parts When ordering spare parts for powder coating equipment, please indicate the following specifications: - Type and serial number of your powder coating equipment - Order number, quantity and description of each spare part Example: - Type PH300 Serial number 1234 5678 - Order no. 203 386, 1 piece, Clamp Ø 18/15 mm When ordering cable or hose material, the required length must also be given. The spare part numbers of this bulk stock is always marked with an *. Wearing parts are always marked with a #. All dimensions of plastic hoses are specified with the external and internal diameter: Example: Ø 8/6 mm, 8 mm outside diameter (o/d) / 6 mm inside diameter (i/d) WARNING! Only original Gema spare parts should be used, because the explosion protection will also be preserved that way. The use of spare parts from other manufacturers will invalidate the Gema guarantee conditions! PH300 Spare parts list 33

PH300 Fresh powder hopper 1 OptiFeed PP06 Powder pump see corresponding operating manual 2 Pneumatic unit see corresponding spare parts list 3 Fluidized hopper see corresponding spare parts list 4 Fluidizing plate 365 009# # Wearing part 2 1 4 3 PH300 Fresh powder hopper 34 Spare parts list PH300

Pneumatic unit PH300 1 Y-connection fitting 1/4"-Ø 8 mm 260 215 2 Solenoid valve 1/2", NW13.5 mm, without coil 1005 120 3 Valve coil 24 VDC-Ex 1005 119 4 Pressure gauge 0-4 bar, 1/8" 258 997 5 Pressure regulator 0-4 bar, 1/4" 240 141 6 Pressure gauge 0-10 bar, 1/8" 259 179 7 R/F unit 0-8 bar, 1/4", incl. pos. 8 and 9 1008 236 8 Filter cartridge 20 µm 1008 239# 9 Condensate container with drain valve 1008 238 # Wearing part 3 5 2 7 1 4 6 8 9 PH300 Pneumatic unit PH300 Spare parts list 35

Fluidized hopper PH300 1 Geka coupling 1" 1000 854 2 Connecting piece 1005 503 3 Pinch valve DN15 complete, incl. pos. 3.1 1006 255 3.1 Pinch valve sleeve DN15 not shown 1006 256# 4 Elbow joint 1/4"-Ø 8 mm 254 029 5 Cap screw M4x12 mm 216 798 6 Throttle valve 1/8"-1/8" 1002 127 7 Screw-in nipple 1/8"-Ø 8 mm 240 087 8 Base piece 1006 655 9 O-ring Ø 64x3 mm, NBR70 255 335 10 Gasket 395 439 11 GEKA coupling with grommet Ø 16 mm 1003 872 12 Hose clamp 17-25 mm 223 085 13 Powder hose Ø 16/23 mm, anti-static 1010 040*# # Wearing part * Please indicate length 13 12 11 10 1 2 3 4 5 6 9 8 7 Fluidized hopper PH300 36 Spare parts list PH300

PH300 Spare parts list 37