Quadruple mass spectrometers (transducer type)

Similar documents
BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Residual Gas Analysis Systems for Industry

High Performance Mass Spectrometers

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Hiden QIC Series Gas Analysers Real-time gas analysis systems

HumiSys HF High Flow RH Generator

Practical approach and problems in in-situ RGA calibration

RM-80 respiration monitor

Choosing a Quadrupole Gas Analyzer Application Note #9

1)! DO NOT PROCEED BEYOND THIS MARK

835 VQM. Features & Benefits

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

PHOENIX L300i Best-in-class Helium Leak Detectors

Mass Spec will not Autotune

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

Oxygen Meter User Manual

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The Broadest Gauging Line in the Industry

The Principles of Vacuum Technology

Gun Vacuum Performance Measurements February 2003

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Vacuum. Methods for in situ QMS calibration for partial pressure and composition analysis. Robert E. Ellefson * abstract

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Selection Guide

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Pneumatic high-pressure controller Model CPC7000

Marc McMullen. Physics Detector Support Group

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Total Pressure Measurement Using Residual Gas Analyzers

Mass Flow Controller (MFC) for Gases

InstruTech, Inc. Hot Cathode Ionization Vacuum Gauge IGM401 Module The Hornet. User Manual

Additel 761 Automated Pressure Calibrators Selection Guide

ELD500 LEAK DETECTOR INSTRUCTION MANUAL. Publication number: D Issue: B Original Instructions. edwardsvacuum.com

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

Additel 761 Automated Pressure Calibrators

Mass Flow Controller (MFC) for Gases

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Go/no-go test for the acceptance of components for unbaked vacuum sectors

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

C-Flow Coriolis Mass Flow Meters

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Panther 5 Acute Care Ventilator

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

The New PHD 4 Portable Helium Detector

Pneumatic high-pressure controller Model CPC7000

Additel 780 Series Pressure Controller

Operation of the Perkin Elmer TGA-GC/MS

Additel 761 Automated Pressure Calibrators

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

TR Electronic Pressure Regulator. User s Manual

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

Resist round robin ELETTRA

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

628 Differential Pressure Decay Leak Tester

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Determination of the Vacuum System for R2R by using a New Pumping Simulation Program

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

UT 3000 Mercury Ultratracer

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

AIR FLOW CALIBRATORS Single Sensor Designs

OXYBABY - MOBILE HAND HELD GAS ANALYSER

Pressure Calibrators. Series PC..., PM...

AX5000 Operational Manual

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

ADDENDUM IMPORTANT DOCUMENT INVITATION TO BID ADDENDUM. OPENING DATE & TIME: January 3, 2018 at 3:00PM

Model 601CV. Mass Flow Controller. Product Features:

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

ADT 761 Automated Pressure Calibrator

Mass Flowmeters. Mass Flowmeters for Gases

InstruTech, Inc. Vacuum Gauge Controller B-RAX User Manual. InstruTech, Inc S. Fordham St. Longmont, CO USA

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Additel 780 Series Pressure Controller

ISO/TC 112/WG 2 N 49. ISO TS QMS WD v6. Date of document Expected action Comment Due Date Background

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

METHODS FOR IN SITU QMS CALIBRATION FOR PARTIAL PRESSURE AND COMPOSITIONAL ANALYSIS

Digital deadweight tester Model CPD8500

Larimax. Residual Gas Analysers and Gas Analysis Systems. Index. Low Cost PC Controlled RGA PC Controlled RGA for gas analysis

InstruTech, Inc. Hot Cathode Ionization Vacuum Gauge With Dual Convection IGM402 Module The Hornet. User Manual

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

UNDERSTANDING, ACCELERATED

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

Transcription:

Quadruple mass spectrometers that meet the need for sensitive analysis and low outgassing which were specifically designed to be controlled by PCs Quadruple mass spectrometers (transducer type) M-070QA-TDF, M-101QA-TDF, M-101/201QA-TDM Overview Quadruple mass spectrometers are widely used in the gas analysis involved with thin film manufacturing equipment, furnaces, accelerators, etc. Quadruple mass spectrometers being used with these applications require low outgassing and sensitive analysis. The quadruple mass spectrometers M-101QA-TDF and M-101/201QA-TDM suit these applications. They are highly sensitive with a high level of functionality, have low outgassing, and are specifically designed to be controlled via PCs. The M-070QA-TDF is a low-priced quadruple mass spectrometer that best-suits the monitoring of residual gasses in various types of vacuum equipments. It can be used in controlling the vacuum quality of production equipment and as a gas analyzer in research and development. Features 1. High sensitivity -A secondary electron multiplier is used as the detector (M-101/201QA-TDM). 2. Low outgassing analyzer tube - Utilizes a low outgassing ion source. - Degassing function included (*1) 3. Superior basic performance Supports sophisticated analysis. -Detailed settings for ionization voltage and emission current (*1). - Wide dynamic range 4. QUADVISION 3 Both Japanese/English versions of easy to operate control software - Windows-compliant - Multi control (Up to 8 units in parallel) - Measurement data can be converted to CSV format. 5. Many I/O functions provided as standard - Automatic measurement signal - Analog signal input - Set point output *1: This function not included in the M-070QA-TDF. Selection guide Application field M-070QA-TDF M-101QA-TDF M-101QA-TDM M-201QA-TDM Residual gas monitoring in PVD process equipment Residual gas monitoring in CVD process equipment Residual gas monitoring in etching equipment Residual gas monitoring in vacuum equipment Residual gas analysis in ultra-high vacuum equipment Vacuum gas monitoring in accelerators Inorganic gas analysis Outgassing analysis in thermobalances Thermal desorption gas analysis Trace gas analysis PFC gas analysis R&D : Best, : Good, : Contact us. The table above shows quadruple mass spectrometers recommended for general use. If you are considering using one for an application other than given above please contact our sales division. 1

Specifications Basic performance Model name Standard model High-sensitivity model M-070QA-TDF M-101QA-TDF M-101QA-TDM M-201QA-TDM Measurable range of mass numbers 1 ~ 70amu 1 ~ 100amu 1 ~ 200amu Resolution M/Δ M 2M Sensitivity(N 2 ) FC 1.5 x 10-6 A/Pa or more 7.0 10-6 A/Pa or more 2.5 10-6 A/Pa or more 1.8 10-6 A/Pa or more SEM ー 2.5A/Pa or more 1.8A/Pa or more Minimum detectable partial pressure 6.7 x 10-9 Pa or less 5.0 10-10 Pa or less 1.0 10-12 Pa or less Operating pressure 1.3 x 10-2 Pa or less Dynamic range 6 digits 7 digits Specifications Detector FC RoHS/CE Applications EM ーー Ion source Cage type (Option: Box type *1) Cage type (Option: Box type *1) Filament Baking temperature Two yttria-coated iridium filaments Two yttria-coated iridium filaments (Option: Tungsten *1) 250 (analyzer tube only) Degassing function ー Electron bombardment Connection flange Rated input voltage AC100V ~ AC240V φ70icf Maximum power consumption 60W 90W Mass Analyzer tube 1.5kg 1.4kg 1.6kg Communication interface Standard software *1: For the optional specifications, please contact us separately. Controller 2.1kg 2.2kg Residual gas monitoring in PVD equipment and various types of vacuum equipment Leak testing of PVD equipment and various types of vacuum equipment RS-232C/485 QUADVISION3 Compliant Residual gas monitoring in PVD equipment, accelerators, and various types of vacuum equipment Inorganic gas analysis, thermal desorption gas analysis, etc. Dimensional outline drawing M-070QA-TDF M-101QA-TDF M-101QA-TDM M-201QA-TDM 2

Quadruple mass spectrometers M-401QA-MU/G Overview Quadruple mass spectrometers of high performance and a high level of functionality that can measure mass numbers up to 410 amu The M-401QA-MGSY/MUSY can measure ten times faster (than our previous models) with general usage. Features 1. High-speed measurements. (M- 401QA-MGSY/ MUSY) Data of M/e = 1 to 400 obtained in just one second. 4. Analyzer tube with low outgassing Utilizes low outgassing ion source. Degassing function included 2. Two types of ion sources Supports both UHV cage and gas introduction box types. 3. Highly sensitive (M- 401QA-MGHY/ MUHY) 8 digits of dynamic range Selection guide Application field M-401QA-MUHY M-401QA-MGHY M-401QA-MUSY M-401QA-MGSY Residual gas analysis in ultra-high vacuum equipment Vacuum gas monitoring in accelerators Inorganic gas analysis Outgassing analysis in thermobalances Thermal desorption gas analysis Trace gas analysis PFC gas analysis R&D : Best, : Good, : Contact us. The table above shows quadruple mass spectrometers recommended for general use. If you are considering using one for an application other than given above please contact our sales division. 3

Specifications Basic performance Specifications RoHS/CE Applications Model name Mass number Resolution High-sensitivity measurement High-speed measurement M-401QA-MGHY M-401QA-MUHY M-401QA-MGSY M-401QA-MUSY 1 ~ 410amu M/ Δ M 2M N 2 sensitivity FC 4.0 10-7 A/Pa 4.0 10-6 A/Pa Minimum detectable partial pressure Maximum operating pressure SEM 4.0 10-1 A/Pa 4.0A/Pa 4.0 10-1 A/Pa 4.0A/Pa 1.0 10-12 Pa 1.3 10-2 Pa or less 5.0 10-12 Pa Dynamic range 8 digits 7 digits 7 digits (At high speed) 5 digits Ion source Gas introduction type (Box type) UHV type (Cage type) Filament Y203 Note (1) Baking temperature Gas introduction type (Box type) 300 (Analyzer tube only) UHV type (Cage type) Degassing function Ion source heater Electron bombardment Ion source heater Electron bombardment Sweep rate 10mSec/amu ~ 1mSec/amu ~ Connection flange Rated input voltage Maximum power consumption φ 114ICF AC100V ~ AC240V 300W Mass Analyzer tube 5.1Kg Controller Communication interface Standard software 5.7Kg RS-485/USB QUADVISION Compliant Thermal analysis, thermal desorption analysis, outgassing analysis, GC-MS for inorganic gases, high-speed scan measurements, etc. Note (1): Please contact us if optional filament materials are required. Dimensional outline drawing Control unit Analyzer tu 50 cm in length connection cable. 4

Software designed for quadruple mass spectrometers QUADVISION 3 Easy measurements via simple operation Leak test Partial pressure measurement Multiple ion detection Mass peak analog/bar Recipe/sequence measurement Details of QUADVISION 3 Applicable quadruple mass M-070QA-TDF, M-101/201QA series Included as standard: RS-232C/485 for communication spectrometers M-401QA series Measurement mode Multiple ion detection (SIM) Trend monitor of mass numbers with up to 16 channels Mass peak monitor (MPM) Continuous measurement of mass spectra within a specified range Leak test (LT) Leak test using a specified mass number Partial pressure measurement (PPM) Partial pressure measurement of 10 fixed components (H 2, He, CH 4, H 2 O, CO, N 2, HC, O 2, Ar, CO 2, and total pressure) Other functions Recipe function Area calculation Adjustment mode (Mass number calibration, waveform adjustment) Conversion of saved data into CSV format Status check Automatic measurement, analog input (0 to 10 V), set point output Reading of pressure Pressure values can be loaded into QUADVISION 3 via RS-232C communication. *2 Option Reading of temperature Temperature values can be loaded into QUADVISION 3 via RS-232C communication. *3 NIST conversion Saved data can be converted to a format searchable in the NIST library. Personal computer OS Windows XP, 7 specifications Interface RS-232C/485 port Note * 1: For the M-070QA-TDF and M-101/201QA-TDM/F only. * 2: Reading the pressure requires our specific vacuum gauge and cable. * 3: Reading the temperature requires our specific temperature controller and cable. 5

Mobile software designed for quadruple mass spectrometers QUADVISION 3 Mobile Simplified mobile software of QUADVISION 3 Easy and handy operation and measurements via touch panel - Easy and handy operation of partial pressure control and leak tests - Operation via touch panel - Wireless (Bluetooth) measurements also supported. Menu screen Measurement screen Chart screen Trend screen Depending on the application screen switching is supported Numerical value screen Parameter screen Details of QUADVISION 3 Mobile Applicable quadruple M-070QA-TDM, M-101/201TDM series mass spectrometers Communication specifications Wireless specifications: Bluetooth Wired specifications: RS-232C Measurement mode Multiple ion detection (SIM) Mass peak monitor (MPM) Leak test (LT) Partial pressure measurement (PPM) Other functions Operation with a touch panel Set point output (Note 1) Recipe function Status check function Data saving function (Note 2) PC specifications OS: Windows XP, 7 Interface: RS-232C, Bluetooth Note 1: Set points are output from the controller of the quadruple mass spectrometer. Note 2: Saved data can be reloaded and processed using the QUADVISION 3 software. Note 3: No adjustment mode available. The QUADVISION 3 software needs to be used to make any necessary adjustments. 6

System Quadruple mass spectrometer that can be used for various types of analysis through retrofitting it with other equipment: Compact gas analysis system M-070/101/201/401GA-D series Simplified gas analysis system that utilizes a differential pump - Incorporation of a pump system (TMP + MP) enables the analysis of gasses at pressures not within the normal operating range of a quadruple mass spectrometer, such as processing pressure or atmospheric pressure. - Depending on the application a quadruple mass spectrometer or gas introduction system, etc. can be retrofitted. Applications Residue analysis in various types of vacuum equipment Process gas analysis Inorganic gas analysis Thermal desorption spectrometry Gas analysis for research and development Ordering information Product code Model name Trade name Product name Remarks 20110 M-401QA-MGSY Quadruple mass spectrometer (gas introduction type ion source) Gas introduction type (box type), high-speed sweep, Y203-FIL 20111 M-401QA-MUSY Quadruple mass spectrometer (UHV type ion source) UHV type (cage type), high-speed sweep, Y203-FIL 20012 M-401QA-MGHY Quadruple mass spectrometer (gas introduction type ion source) Gas introduction type (box type), high sensitivity, Y203-FIL 20013 M-401QA-MUHY Quadruple mass spectrometer (UHV type ion source/y203) UHV type (cage type), high sensitivity, Y203-FIL 20090 M-201QA-TDM (W) Quadruple mass spectrometer 200 amu, M type, W-FIL, an AC adapter included, no communication cable * 20091 M-201QA-TDM (Y) Quadruple mass spectrometer 200 amu, M type, Y-FIL, an AC adapter included, no communication cable * 20092 M-101QA-TDM (W) Quadruple mass spectrometer 100 amu, M type, W-FIL, an AC adapter included, no communication cable * 20093 M-101QA-TDM (Y) Quadruple mass spectrometer 100 amu, M type, Y-FIL, an AC adapter included, no communication cable * 20094 M-101QA-TDF (W) Quadruple mass spectrometer 100 amu, F type, W-FIL, an AC adapter included, no communication cable * 20095 M-101QA-TDF (Y) Quadruple mass spectrometer 100 amu, F type, Y-FIL, an AC adapter included, no communication cable * 20190 M-201QA-TDM (Re) Quadruple mass spectrometer (box type ion source) 200 amu, M type, Re-FIL, a box type ion source, an AC adapter included, no communication cable * 20191 M-101QA-TDM (Re) Quadruple mass spectrometer (box type ion source) 100 amu, M type, Re-FIL, a box type ion source, an AC adapter included, no communication cable * 20096 M-070QA-TDF Quadruple mass spectrometer Configuration: An analyzer tube, a controller, an AC adapter, and software (QUADVISION) 20493 Ion source for M-070 For maintenance 20290 RS-232C cable for quadruple mass spectrometer (1.5 m) 20291 RS-232C cable for quadruple mass spectrometer (3 m) 20292 RS-232C cable for quadruple mass spectrometer (5 m) 20293 RS-232C cable for quadruple mass spectrometer (10 m) 20296 RS-485 cable for quadruple mass spectrometer (5 m) RS-485 cable (5 m) + Y cable 20297 RS-485 cable for quadruple mass spectrometer (10 m) RS-485 cable (10 m) + Y cable 20298 RS-485 cable for quadruple mass spectrometer (15 m) RS-485 cable (15 m) + Y cable RS-232C conversion PARANI-SD1000 Serial number BLUETOOTH conversion adapter BLUETOOTH specifications of QUADVISION3 MOBILE 20299 RS-485 cable for quadruple mass spectrometer (20 m) RS-485 cable (20 m) + Y cable 20390 RS-485 card 20391 RS-485 board 20392 COM-1PD (USB) H COM-1PD (USB) H USB-RS485 converter 20395 AC adapter extension cable (5 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070. 20396 AC adapter extension cable (10 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070. 20397 AC adapter extension cable (15 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070. 20398 AC adapter extension cable (20 m) For M-101/201QA: The AC adaptor cable extension can also be used with the 070. 20418 NIST library data conversion software for M-QA For M-100/200/400QA 20490 TD-W-FIL W filament for quadruple mass spectrometer For M-101/201 20491 TD-Y-FIL Y filament for quadruple mass spectrometer For M-101/201 20492 TD-Re-FIL Re filament for quadruple mass spectrometer (for box type ion For M-101/201 source) 20130 401G-Y203-FIL QMS401-FILAMENT-Y203 GAS INTRODUCTION TYPE 20131 401U-Y203-FIL QMS401-FILAMENT-Y203 UHV TYPE 30111 V-040LV-MMI DN40 manual L-shape valve MSB Protective valve for M-101/201 February 2011