AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Similar documents
Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

The Broadest Gauging Line in the Industry

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

CALIBRATION CERTIFICATE # 500

ISO/TC 112/WG 2 N 49. ISO TS QMS WD v6. Date of document Expected action Comment Due Date Background

at NIST: ultra-low outgassing rates

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

10/8/2013. AFS (Agilent Floating Suspension) Technology. Contents. Traditional Cantilever Bearing Suspension

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

The Principles of Vacuum Technology

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO

ali-q TM Gravimetric Verification Procedure

Improve Process Reliability

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Vacuum Pumps. Turbomolecular Pumps F31 F32 F33 F34 F35 F36 F37 F38 F39 F40

GA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No

MagneticTurbo TM. TurboDrag pumps with pumping speed up to 1500 l/s TMH/U 1000 M / TMH/U 1600 M. Pumping speed. Start / Chapter content

M-06 Nitrogen Generator (Nitrogen Making Machine)

EN ISO/IEC Technical Requirements

The Helium Leak Detector

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

6301 TYPE CAST IRON SAFETY VALVES

Total Pressure Measurement Using Residual Gas Analyzers

VIC offers a variety of Calibrated Gas Leaks

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

Development of a high vacuum sample preparation system for helium mass spectrometer

Gas Mixture Two Components. Gas Mixtures Two Components

Chapter 6 Leak detection

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Chapter 22 Testing Protocols

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

Research and Development. Money in the Pipeline

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 3

Central scientific research automobile and automotive engine institute

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

Go/no-go test for the acceptance of components for unbaked vacuum sectors

Customer Responsibilities

Practical approach and problems in in-situ RGA calibration

High Performance Mass Spectrometers

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Gun Vacuum Performance Measurements February 2003

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

GMA FUNCTIONAL TEST SETTING & TESTING OF SPIN UP PARAMETERS. P0586 REV -- 20, June 2000 GPB SCIENCE MISSION PROCEDURE

Determination of the Vacuum System for R2R by using a New Pumping Simulation Program

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

INSTRUCTIONS. VP-100 Ion Pump. Model / R001

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Gas mixtures. Individual solutions specifically for your application

MET-101 Introduction to Metrology

GMC-I Service GmbH Calibration Center

Vortex Meters for Liquids, Gas, and Steam

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Metering Code Gas TSO, measurement by connected party Effective from to the present

Environmental Gasket Company Ltd. 309 Hanzhongmen Ave. Nanjing, PR China. 13EGC-MPA /Hh/Mor/Scr Fishbone Gasket

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

The new PTB standard for dynamic vacuum pressures

PRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL

GPP model GPPT model GPC model CLP model

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Chapter 8: Cryo-sorption pumps

1811G/H PITOT-STATIC TEST SET

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Technical Specifications of Hydrogen Isotope Handling and Recovery System

The ERCB Directive 017 Overview

Interlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories

E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University

Stability and traceability of calibration gases for EN 14181

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Sartorius CCL kg Prototype Mass Comparator

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Maximum precision for quantifiable success.

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

Selecting the right pressure sensor for your application

Instruction Manual Contact Pressure Vacuum Gauge

New ANSI Fall Protection Standards

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Transcription:

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Agilent Vacuum Products: Our Committment to Quality Agilent s commitment to quality and Measurement s philosophy Reference Standards (PNEUROP, ISO) Agilent ETM Environmental Test Methodology Methodology used during measurements (Pumping speed/ Compression/ Ultimate pressure) Agilent Depts. in charge of measurements (Instruments calibration, metrology) Agilent Turbomolecular Pumps Measurement Methodology 2

Agilent Commitment to Quality and Measurement Philosophy Quality is of paramount importance to Agilent. The Agilent mission is to strive to obtain the Best In Industry product quality through a series of strict tests. The Agilent Vacuum Product Division (VPD) reflects this philosophy and make sure that every released product is in compliance of the quality standards and also to the internal ETM Agilent standards and metodology. The vacuum performance measurements applied to turbomulecular pumps are regulated by the following standards: ISO 5302:2003(e) Vacuum Technology Turbomolecular pumps Measurement of performance characteristics, equivalent to PNEUROP 5608 ISO 21360 Vacuum technology Standard methods for measuring vacuum-pump performance The vacuum performances tests applied to the Turbo molecular pumps are: High Pressure Pumping Speed for Argon, Helium, Hydrogen and Nitrogen Low Pressure Pumping Speed for Argon, Helium, Hydrogen and Nitrogen Compression Ratios for Argon, Helium, Hydrogen and Nitrogen Ultimate pressure 3

Agilent ETM Environmental Test Methodology The Agilent commitment to technology leadership translates into quality, reliability and performance; our products need to comply with strict criteria, to make sure we can meet the most stringent customer expectations. This development includes a broad range of tests and analyses, performed to ensure the highest levels of performance and reliability. Through the ETM tests, Agilent VPD verifies, step by step, product performance and robustness in order to release a Reliable and High Quality product in line with the Agilent Standard, and ready for our customers demanding specifications. Shock Test Temperature Test Humidity Test Vibration Test Life Test Vacuum Test See detailed Flyer for more information 4

High Pressure & Low Pressure Pumping speed ISO 21360 (2012-04) Specific methods are used to get the most accurate measurement through the entire pressure range: 1. Test dome for Standard conductance method (for pressure <10-6 mbar) Fig. 1 The method adopted for the measurements of the volume flow rate is known as standard Conductance in which a thin orifice divides the test dome (Fig.1) into two volumes. Measuring the pressure in each of the two volumes with a gauge having the same sensitivity, the pumping speed is obtained by the following formula: Where: C is the calculated conductance taking account the orifice size and the gas properties. P10 and P20 are the base pressures in the two dome chambers (Fig.1) while the other is the pressure test. where M is molecular mass of the gas, T is the absolute temperature in K, d and l are geometrical orifice parameters and a is the relative calibration factor of the gauges. 5

High Pressure & Low Pressure Pumping speed ISO 21360 (2012-04) 2. Test for the throughput method (for pressure >10-6 mbar) for the throughput method (Fig.2) Measuring the gas throughput Q flowing inside the test dome and the pressure Pin at the pump inlet, the pumping speed is given by the formula: Fig. 2 Remarks: Pumping speed is measured for four different gases, Argon - Nitrogen - Helium - Hydrogen Curve refers to a sample of 5 different pumps under test. Measuring Uncertainties: A ±10% measurement error in accuracy, has to be considered. This is specified by the ISO21360-1 (2012-04) and the same measurement error is common to all manufacturers testing their pumps. 6

Compression Ratio ISO 21360 (2012-04) The Compression Ratio K is the ratio between the pressure (partial) at the pump exhaust and pressure (partial) at the inlet of the pump for a given process gas, It is determinated by flowing the process gas in the pump foreline with no gas injection into the test dome and so at the inlet of the pump. The Compression reatio is obtained for the four major gases Ar, N 2, He, H 2. Measurements are recorded at three points per decade of the backing pressure. Pf = Vacuum pressure in the backing line Pf 0 = Base Foreline Pressure Pi = Inlet Pressure (measured) Pi 0 = Base inlet pressure Remarks: Curve refers to a sample of 5 different pumps under test. Measuring Uncertainties: A ±20% measurement error in accuracy, has to be considered. This is specified by the ISO21360-1 (2012-04) and the same measurement error is common to all manufacturers testing their pumps. 7

Ultimate Pressure ISO 21360 (2012-04) The base pressure is measured in a leak-free test dome after 48 hours of bake-out through the Turbo pump fitted with ConFlat flange. During the test the ambient temperature is in the range of 15-25 C A ±20% measurement error in accuracy has to be considered. This is specified by the ISO21360-1 (2012-04) and the same measurement error is common to all manufacturers testing their pumps. Reporting: Pumping speed and Compression Ratio are measured for four different gases: Argon - Nitrogen - Helium - Hydrogen. A final report including all the tests results with information about instruments (pressure gauges, flow meter,etc..) used for the test is compiled by the Development Project Manager. A copy of the report is filed in the project dossier following the ISO9000 standards. 8

Agilent Departments in charge of measures (competences, skills, ) Instruments calibration and metrology In order to achieve the highest quality of the products all departments in Agilent VPD are involved in the «quality» process and are required to pay the maximum attention to detail and dedication to their work. In particular special attention is paid to the critical issue of instrument calibration to obtain the best performance and readings from every device used during the important step of qualification and measurement, of paramount importance for the Quality process. To do so experienced and skilled Quality Technicians have the responsibility for both the calibration and verification of the instrumentation used to certify tests both in the R&D lab as well as on the production floor. The control equipment and measuring devices involved in the monitoring of components is regulated by the internal procedure Control tools and equipment and it is applied both to those instruments controlled internally and those instruments controlled by third parties. In case of calibrated measuring instruments, there is a calibration certficate in accordance with ISO/IEC 17025. The frequency of calibration settings is typically 6 to 12 months unless there is an instrument malfunction. In particular, the UHV and Capacitance gauge inspection is regulated by the internal procedure and verification frequency is 6 months for UHV and 12 months for Capacitance gauges (0.1/1 mbar). Capacitive gauge above 1 mbar and flow meters are regularly sent to the control center for factory calibration. Internal audits and calibration are regularly performed by authorized certification/ calibration centers, such as the Spinning Rotor used for verifying the UHV and the Capacitance gauges for 0.1/1 mbar are certified by an authorized certification laboratory. 9