Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Similar documents
Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. Dimensions

Inductive slot sensor

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DK46 - DK800 Supplementary instructions

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

OPTIBAR P 1010 C Technical Datasheet

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure Measurement Single-range transmitters for general applications

Relative pressure transmitter type 520

Manual Power relay SR853

II 2G EEx ia IIC T6. Ignition protection class

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Pressure control, differental pressure control and thermostat Type RT

Pressure switch KP-E. Data sheet

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Magnetic level switch type MR783 Instruction Manual

Operating Instructions

Certificate of Compliance

Operating Instructions

Pressure switch, Differential pressure switch and Thermostat RT-E

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Level sensing relative and absolute pressure transmitter type 712

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

sitrans p Operating Instructions (de/en) Edition 03/2004

VG5 Supplementary instructions

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

Level transmitter LT 100

Pressure Switches Application Guideline

Liquid level instruments BM 24 /BM 51

Further technical information is available on

Pneumatic pressure switch 20DD

I/P Transducer Positioner Module

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Pressure Measurement Single-range transmitters for general applications

Climatic Independent Level Sensor LAR

4/2 way Pneumatic Solenoid Valve

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

SITRANS P measuring instruments for pressure

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Operating Instructions

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

CERTIFICATE OF COMPLIANCE

High-performance submersible pressure transmitter For level measurement Model LH-20

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operating Instructions of BROSA tension load cells, types 0111, 0113

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Arran LED Floodlight Luminaire

Position switches FP series

Electro-Pneumatic Converter YT-940 SERIES

RTD temperature probes

Torque Tube TB300 Digital Transmitters

Orifice Plate Flow Meter

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Bourdon tube pressure gauge for diaphragm seals

Monitoring device NTS 30

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Zelio Relays RSL Slim Interface Plug-In Relays

High-performance submersible pressure transmitter For level measurement Model LH-20

VALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44

Tightness controls TC 1 3 and TC 4

2/2-Way Solenoid Control Valve

High-performance submersible pressure transmitter For level measurement Model LH-10

9700 Transmitter Submersible hydrostatic level transmitter

THERMOSTAT ATEX, Type AMTXs-Ex and AMTXs-Ex/BV Single or double thermostat, rigid rod or capillary exit

Pressure Transmitter P41

Pressure Measurement Single-range transmitters for general applications

Automatic Valve Proving Control

Transcription:

0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SL 2 acc. to EC 61508 LEDs for switching state of sensor and solenoid valve Valve LEDs disconnectable Application The connections to this sensor are sealed with stopping plugs to protect against dirt and moisture. f not all of the connections are used in your application, then seal the remaining stopping plugs on the sensor permanently or check during initial installation and when performing regular maintenance work that the stopping plugs are secure and impermeable. f necessary, tighten the stopping plugs to a torque of 1 Nm. Technical Data specifications Switching element function DC Dual NC Rated operating distance s n 3 mm nstallation flush mountable Output polarity NAMUR Assured operating distance s a 0... 2.4 mm Actual operating distance s r 2.7... 3.3 mm typ. Actuating element Stainless steel 1.4305 / AS 303 8.5 mm x 8.5 mm x 0.5 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 1 Reduction factor r St37 1.3 Reduction factor r Brass 0.6 Nominal ratings Nominal voltage U o 8 V Switching frequency f 0... 3 khz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Suitable for 2:1 technology yes, Reverse polarity protection diode not required Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Time delay before availability t v 1.1 ms Switching state indicator LED, yellow Valve status indicator LED, yellow Functional safety related parameters MTTF d 1470 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Storage temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection (system side) Cage tension spring terminals Core cross-section (system side) 1.5/2.5 mm 2 flexible/rigid Connection (valve side) Cage tension spring terminals Core cross-section (valve side) 1.5/2.5 mm 2 flexible/rigid Housing material PBT Sensing face PBT Degree of protection P67 Tightening torque, housing screws 1 Nm Tightening torque, cable gland M20 x 1.5 ; 7 Nm M12 x 1.5 ; 3 Nm LED switch-off information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 EC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 EC 60947-5-2:2007 nductive sensors for position feedback of standard drives with terminal identification / terminal assignment in accordance with the former DN 45140 T1 available on request. Ask your contact person at Pepperl+Fuchs. Accessories BT65A Activator for F31 series BT65X Activator for F31 series Approvals and certificates UL approval CSA approval CCC approval culus Listed, Purpose ccsaus Listed, Purpose CCC approval / marking not required for products rated 36 V 1

Dimensions 65 M20 x 1.5 S M12 x 1.5 LED V LED Electrical Connection 9 5 35 14 11 9 5.4 77.5 7 40 30 N4-K S V 4 5 1 2 9 / 10 10 / 9 7 / 6 6 / 7 L+ L- L+ L- V+(V-) V- (V+) V- (V+) V+(V-) nterruption of LED: n the case of a polarity reversal of the valve circuit connection/s, the valve status display does not function, i.e. such that low power valves can (also) be connected. 2

ATEX 1G nstruction Device category 1G EC-Type Examination Certificate TÜV 99 ATEX 1479 X 1G Ex ia C T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 gnition protection "ntrinsic safety" Appropriate type NCN3-F31K-N4... Effective internal capacitance C i 100 nf A cable length of 10 m is considered. Effective internal inductance L i 100 µh A cable length of 10 m is considered. and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. f the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. : Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. nstallation, commissioning must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of EC 60079-14 are met. Additional requirements for gas group B/C. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. nformation on electrostatic hazards can be found in the technical specification EC/TS 60079-32-1. The connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also EC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of EC 60079-14, must be used. 3

ATEX 2G nstruction Device category 2G EC-Type Examination Certificate TÜV 99 ATEX 1479 X 1G Ex ia C T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012 gnition protection "ntrinsic safety" Appropriate type NCN3-F31K-N4... Effective internal inductivity C i 100 nf ; a cable length of 10 m is considered. The value is applicable for one sensor circuit. Effective internal inductance L i 100 µh ; a cable length of 10 m is considered. The value is applicable for one sensor circuit. and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. f the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Maximum permissible ambient temperature T amb The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. nstallation, commissioning must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Additional requirements for gas group C. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. nformation on electrostatic hazards can be found in the technical specification EC/TS 60079-32-1. The connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also EC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of EC 60079-14, must be used. 4

ATEX 3G (ic) nstruction Device category 3G (ic) Certificate of Compliance PF 13 CERT 2895 X Standards Effective internal capacitance C i Effective internal inductance L i 3G Ex ic C T6 T1 Gc EN 60079-0:2012, EN 60079-11:2012 gnition protection category "ic" 100 nf ; A cable length of 10 m is considered. 100 µh ; A cable length of 10 m is considered. and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! nstallation, commissioning Maximum permissible ambient temperature T Umax at Ui = 20 V must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of EC 60079-11. The explosion group depends on the connected, energy-limited power supply circuits. The maximum values of the connected, energy-limited valve circuits, must be observed. Each sensor circuit can be operated with the stated maximum values and with simultaneous operation of the valve circuits. for Pi=34 mw, i=25 ma, T6 for Pi=34 mw, i=25 ma, T5 for Pi=34 mw, i=25 ma, T4-T1 100 C (212 F) for Pi=64 mw, i=25 ma, T6 for Pi=64 mw, i=25 ma, T5 for Pi=64 mw, i=25 ma, T4-T1 100 C (212 F) for Pi=169 mw, i=52 ma, T6 for Pi=169 mw, i=52 ma, T5 for Pi=169 mw, i=52 ma, T4-T1 90 C (194 F) Maximum values of the valve circuit U i = 32 V; i = 240 ma; C i = 10 nf; L i = 20 µh The values are applicable to each valve circuit. A cable length of 10 m is taken into account. The sensor must not be mechanically damaged. Connection parts Additional requirements for gas group C. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. nformation on electrostatic hazards can be found in the technical specification EC/TS 60079-32-1. The connection parts are to be installed, such that a minimum protection class of P20 is achieved, in accordance with EC 60529. The connecting cable must be protected from tension and torsional loading or installed in such a way, that an applied force of 30 N, acting in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also EC 60079-11. 5