Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Similar documents
Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 2 mm

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DK46 - DK800 Supplementary instructions

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

II 2G EEx ia IIC T6. Ignition protection class

Manual Power relay SR853

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pressure switch KP-E. Data sheet

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Pressure Measurement Single-range transmitters for general applications

Position switches FP series

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Pressure control, differental pressure control and thermostat Type RT

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Relative pressure transmitter type 520

Pressure Switches Application Guideline

Level sensing relative and absolute pressure transmitter type 712

Pressure switch, Differential pressure switch and Thermostat RT-E

Level transmitter LT 100

VG5 Supplementary instructions

Further technical information is available on

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

OPTIBAR P 1010 C Technical Datasheet

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

SITRANS P measuring instruments for pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Magnetic level switch type MR783 Instruction Manual

Operating Instructions

sitrans p Operating Instructions (de/en) Edition 03/2004

Automatic Valve Proving Control

Tightness controls TC 1 3 and TC 4

Operating Instructions

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Certificate of Compliance

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Liquid level instruments BM 24 /BM 51

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

Orifice Plate Flow Meter

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

TeSys protection components

RTD temperature probes

I/P Transducer Positioner Module

[Instruments for vacuum measurement, checking and adjustment] 3

Zelio Relays RSL Slim Interface Plug-In Relays

Torque Tube TB300 Digital Transmitters

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Monitoring device NTS 30

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

High-performance submersible pressure transmitter For level measurement Model LH-20

THERMOSTAT ATEX, Type AMTXs-Ex and AMTXs-Ex/BV Single or double thermostat, rigid rod or capillary exit

Prewired position switches FA series

Pressure Measurement Single-range transmitters for general applications

Pneumatic pressure switch 20DD

High-performance submersible pressure transmitter For level measurement Model LH-10

DSL, DSH: Specially designed pressure limiter

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

4/2 way Pneumatic Solenoid Valve

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Types and approvals. Page 1/6. Data Sheet

High-performance submersible pressure transmitter For level measurement Model LH-20

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Gas density monitor With integrated transmitter Model GDM-100-TI

Certificate of Compliance

Transmitter CS 21 Operation Manual

Transcription:

Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery directive EC-Type Examination Certificate TÜV99 ATEX 1479X Connection N4-K Accessories BT65A BT65X BT115A BT115X BT65B BT115B S V 4 5 1 2 9 / 10 10 / 9 7 / 6 6 / 7 L+ L- L+ L- V+(V-) V- (V+) V- (V+) V+(V-) 77.5 7 LED Technical Data specifications Switching element function DC Dual NC Rated operating distance s n 3 mm nstallation flush mountable Output polarity NAMUR Assured operating distance s a 0... 2.3 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 1 Reduction factor r St37 1.2 Reduction factor r Brass 0.63 Nominal ratings Nominal voltage U o 8.2 V (R i approx. 1 kω) Switching frequency f 0... 100 Hz Hysteresis H typ. 5 % Reverse polarity protected reverse polarity protected Short-circuit protection yes Suitable for 2:1 technology yes, Reverse polarity protection diode not required Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma ndication of the switching state LED, yellow Valve status indication LED, yellow Functional safety related parameters MTTF d 1980 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Mechanical specifications Connection (system side) Cage tension spring terminals Core cross-section (system side) Flexible: 0.2... 1.5 mm 2 rigid: 0.2... 2.5 mm 2 Connection (valve side) Cage tension spring terminals Core cross-section (valve side) Flexible: 0.2... 1.5 mm 2 rigid: 0.2... 2.5 mm 2 Housing material PBT Sensing face PBT Protection degree P67 Tightening torque, housing screws 1 Nm Tightening torque, cable gland M20 x 1.5 ; 7 Nm M12 x 1.5 ; 3 Nm Note LED switch-off information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 EC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 EC 60947-5-2:2007 Approvals and certificates 30 S LED M12 x 1.5 V 1

UL approval CSA approval CCC approval nterruption of LED: n the case of a polarity reversal of the valve circuit connection/s, the valve status display does not function, i.e. such that low power valves can (also) be connected. culus Listed, Purpose ccsaus Listed, Purpose Products with a maximum operating voltage of 36 V do not bear a CCC marking because they do not require approval. 2

ATEX 1G nstruction Device category 1G Standard conformity EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007 gnition protection "ntrinsic safety" EC-Type Examination Certificate Appropriate type Highest permissible ambient temperature Electrostatic charging 1G Ex ia C T6 TÜV 99 ATEX 1479 X NCN3-F31K-N4... 100 nf A cable length of 10 m is considered. 100 µh A cable length of 10 m is considered. sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. f the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of EC 60079-14 are met. When used in group B/C non-permissible electrostatic charges should be avoided on the plastic housing parts.. The connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also EC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of EC 60079-14, must be used. 3

ATEX 2G nstruction Device category 2G Standard conformity EN 60079-0:2006, EN 60079-11:2007 gnition protection "ntrinsic safety" EC-Type Examination Certificate Appropriate type Highest permissible ambient temperature 1G Ex ia C T6 TÜV 99 ATEX 1479 X NCN3-F31K-N4... 100 nf ; a cable length of 10 m is considered. The value is applicable for the sensor circuit. 100 µh ; a cable length of 10 m is considered. The value is applicable for the sensor circuit. sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. f the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Electrostatic charging When used in group C non-permissible electrostatic charges should be avoided on the plastic housing parts. The connection cables should either be fixed when laid and mechanically protected or installed in such a way, that a force of 30 N applied in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also EC 60079-11. Depending on the type of installation, a suitable cable in accordance with Type A oder B of EC 60079-14, must be used. 4

ATEX 3G (nl) Note nstruction This instruction is only valid for products according to EN 60079-15:2003, valid until 31-May-2008 Device category 3G (nl) Standard conformity EN 60079-15:2003 gnition protection category "n" Maximum permissible ambient temperature T Umax at Ui = 20 V 3G EEx nl C T6 X 100 nf ; A cable length of 10 m is considered. 100 µh ; A cable length of 10 m is considered. sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of EC 60079-15. The explosion group depends on the connected, energy-limited power supply circuits. The maximum values of the connected, energy-limited valve circuits, must be observed. Each sensor circuit can be operated with the stated maximum values and with simultaneous operation of the valve circuits. for Pi=34 mw, i=25 ma, T6 for Pi=34 mw, i=25 ma, T5 for Pi=34 mw, i=25 ma, T4-T1 for Pi=64 mw, i=25 ma, T6 for Pi=64 mw, i=25 ma, T5 for Pi=64 mw, i=25 ma, T4-T1 for Pi=169 mw, i=52 ma, T6 for Pi=169 mw, i=52 ma, T5 for Pi=169 mw, i=52 ma, T4-T1 90 C (194 F) Maximum values of the valve circuit U i = 32 V; i = 240 ma; C i = 10 nf; L i = 20 µh The values are applicable to each valve circuit. A cable length of 10 m is taken into account. The sensor must not be mechanically damaged. The connecting cable must be protected from tension and torsional loading or installed in such a way, that an applied force of 30 N, acting in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also EC 60079-11. 5

ATEX 3G (ic) nstruction Device category 3G (ic) Standard conformity EN 60079-11:2007 gnition protection category "ic" 3G Ex ic C T6 X 100 nf ; A cable length of 10 m is considered. 100 µh ; A cable length of 10 m is considered. sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Maximum permissible ambient temperature T Umax at Ui = 20 V must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of EC 60079-11. The explosion group depends on the connected, energy-limited power supply circuits. The maximum values of the connected, energy-limited valve circuits, must be observed. Each sensor circuit can be operated with the stated maximum values and with simultaneous operation of the valve circuits. for Pi=34 mw, i=25 ma, T6 for Pi=34 mw, i=25 ma, T5 for Pi=34 mw, i=25 ma, T4-T1 for Pi=64 mw, i=25 ma, T6 for Pi=64 mw, i=25 ma, T5 for Pi=64 mw, i=25 ma, T4-T1 for Pi=169 mw, i=52 ma, T6 for Pi=169 mw, i=52 ma, T5 for Pi=169 mw, i=52 ma, T4-T1 90 C (194 F) Maximum values of the valve circuit U i = 32 V; i = 240 ma; C i = 10 nf; L i = 20 µh The values are applicable to each valve circuit. A cable length of 10 m is taken into account. The sensor must not be mechanically damaged. Electrostatic charging Connection parts When used in group C non-permissible electrostatic charges should be avoided on the plastic housing parts. The connection parts are to be installed, such that a minimum protection class of P20 is achieved, in accordance with EC 60529. The connecting cable must be protected from tension and torsional loading or installed in such a way, that an applied force of 30 N, acting in the direction of the cable inlet for one hour, does not lead to any visible displacement of the cable connections, even though the cable sheathing is displaced, see also EC 60079-11. 6