Dealing with Electrical Hazards in the Workplace

Similar documents
Why do I need to do an Arc-Flash Analysis?

By: Bruce Bowman, P.E.

Electrical Safety. Toolbox Talk

This training session covers electrical safety for unqualified persons. Unqualified persons are machine operators, operators of powered industrial

Electrical Safety. Unqualified Worker

Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace

Electrical Safety & Arc Flash Awareness DYMAX ENGINEERING. Presented By Rick Edel

Definitions found in several locations:

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs.

PURE H2O FORUM. Safeguarding Operations Personnel Understanding Arc Flash & Developing an Electrical Safety Program

Arc Flash 101. presented by Arc Flash Blaster LLC

This presentation provides an overview of modern methods for minimizing the arc-flash hazard.

Arc Flash. Safety 21

ELECTRICAL FLASHOVER HAZARDS AND SAFETY MEASURES REFERENCE TO DESIGN AND MAINTENANCE. Intrduction: B.MAHARANA, AGM(EM)/HOD NTPC,RAMAGUNDAM

SAFE-WORK PRACTICES Working On Or Near Energized Electrical Equipment CAT A-1 SOP #4

2018 NFPA 70E Significant Changes 7/27/2017. EFCOG Electrical Safety Task Group Workshop, July 2017

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

WHAT IS THE N.F.P.A. 70E

Leader s Guide ERI Safety Videos

Electrical Hazard Assessments: OSHA & The NFPA 70E?

Electrical Safety. Introduction

70e Training - Electrical Safety in the Workplace

2012 NFPA 70E: Electrical Safety In The Workplace

ARC FLASH HAZARD ANALYSIS

Progressive Safety Services LLC - All Rights Reserved

CHAPTER 2: ELECTRICAL SAFETY

Electrical Safety Program

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks

Selection of Electrical PPE Tables

UNDERSTANDING ARC FLASH REQUIREMENTS

CS ENERGY PROCEDURE FOR ELECTRIC SHOCK TREATMENT AND REPORTING CS-OHS-05

Removing Yourself from Hazards During Equipment Operation

Preparer: Owner: Approver: EHS Team Member TES Manager Site Manager

REPORTING AND TREATMENT REQUIRED AS A RESULT OF AN ELECTRICAL INCIDENT CS-OHS-5

Industrial Relations

D Square Construction LLC

POWER PLANT RELAY REPLACEMENT DELIVERABLE ARC FLASH

Innovative Techniques for Mitigating Arc Flash Exposure

Appendix A: Energized Work Permit

protecting your workers from the hazards of arc flash

Electrical Safety Program

Leader s Guide ERI Safety Videos

GENERAL ELECTRICAL SAFETY

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services

Welcome to this training session about arc flash. In this session, we ll talk about the hazards and risks of working around exposed, energized

Electrical Safety in Hospitals

arc flash hazard analysis

NFPA 70E What Changed? Keeping People Safe from Electrical Hazards for over 50 Years

Risk Assessment Procedure

Elements of a Lockout/Tagout Program OSHA

Electrical. OSHA Office of Training and Education 1

to the 2009 Edition Standards & Codes Introduction Background Byron Jordan Sr. Field Engineer

NFPA 70E, Proposed Changes. Electrical Safety in the Workplace NFPA Conference & Expo

Reference Number PDS 10 (RIC Standard: EP SP)

Making Safer Facilities

Doc No: ELECTRIC Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

IWU PHYSICAL PLANT SAFETY PROGRAM. Revision: 1 ELECTRICAL SAFETY Section: 4

SECTION 51 NFPA 70E POLICY. Health & Safety Policy and Procedures Manual

NECA Personal Protective Equipment (PPE) Selector

11/2/2017. Course Objectives. Overview

Solutions SOLUTIONS GUIDE SOLUTIONS GUIDE. It s your responsibility to protect your workers from arc flash hazards

Electrical Safety Guide

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

Electrical Safety. Hazard Awareness

ES18 Security Theory/Regulations Answer Schedule

Safety Powder Spray Systems

GAS FUEL VALVE FORM AGV5 OM 8-03

CSA Z462 2 nd TO 3 rd EDITION DIFFERENCES CHANGES & UPDATES

MANAGING ARC FLASH: A Risk Management Approach. Steve Williams Engineers Australia - Electrical College 14 June 2017, Brisbane

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC

The Electrical Safety Guide. An Educational Training Manual for Industry Professionals

Ground Fault Circuit Interrupter(GFCI) Policy

HIGH-IMPACT SAFETY TRAINING FOR QUALIFIED ELECTRICAL WORKERS

ANSWER SHEET NFPA 70E REVIEW 51. A B C D 76. A B C D 2. A B C D 77. A B C D 3. A B C D 52. A B C D 78. A B C D 4. A B C D 53.

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

Electrical Safety A HANDBOOK FOR EMERGENCY PERSONNEL

This is (Enter Company Name Here) Arc Flash Prevention policy. (Enter Name Here) will be responsible for overall direction of the Safety Program.

In the electrical industry the phrase arc flash is generating a lot of

MANAGING ARC FLASH RISKS: A Strategic Approach. Steve Williams Rockwell Automation TechED March 2016, Auckland

100 Questions on Electrical Safety Study Guide

Hazardous Energy Control (Lockout-Tagout)

CONTROL OF HAZARDOUS ENERGY (LOCKOUT/TAGOUT)

First responder beware

Original Date of Issue: 04/09

OSHAcademy Course 715 Study Guide. Electrical Safety Basics

Electrical Safety Guide

Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY

Why an Effective Safety Program is Essential

2. What is the definition of an electrocution hazard? a. Electrocution results when a person is exposed to a lethal amount of electrical energy

Electrical Safety Program

ARC:Gear from Unipart Rail

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Ground Fault Protection for Electrical Tools

THE OSHA LOCK-OUT/TAG-OUT STANDARD

Arc flash versus arc resistant; different concerns

Major Changes. Standard. TECH TOPIC standards and. By Peter Walsh, PE

GFCIs and Swimming Pools A Natural Fit

5 th year (Control department)

INSPECTION OF MEDICAL DEVICES

Electrical Safety Program

Transcription:

Dealing with Electrical Hazards in the Workplace Presented By: Tom Norwood Sr. Safety Specialist A SUBSIDIARY OF MEGGER TRAINING INSTITUTE, INC. Dallas, Texas

Introduction Several hundred electrical fatalities occur annually as a result of electrical shock Over half are from 120-volts Electrical contacts result in (NIOSH): 4,000 non-disabling injuries a year 3,600 disabling injuries a year One death every day

Introduction 10-15 15 employees per day are hospitalized from arc-flash burns Arc-flash injuries are catastrophic to the victim: Physically Psychologically Financially

Introduction Electricity is a Silent killer Cannot be tasted, seen, heard, or smelled Electricity exposes employees to: Shock Serious burns Falls Injury Death Any and everyone is susceptible

Hazards of Electricity Electrical Shock Electrical Arc-Flash Electrical Arc-Blast

Electrical Shock Shock caused by a difference in potential across the body Severity of shock depends on several factors: Resistance of the body Circuit voltage Amount of current flowing through the body Current path through the body Area of contact Duration of contact

Current Range and Effect Current 1 ma 1-3 3 ma 3-9 9 ma 9-25 ma 25-60 ma 60 ma or more 4 A or more 5 A or more Effect Barely perceptible Perception threshold (most cases) Painful sensations Muscular contractions (can t t let go) Respiratory paralysis (may be fatal) Ventricular fibrillation (probably fatal) Heart paralysis (may (probably restart fatal) through CPR) Tissue burning (fatal if vital organ)

Tissue Muscle Bone Nerves Blood vessels Tissue Damage High current passing through the body can cause damage to: Heart Liver Lungs Kidneys Anything else it passes through

Electrical Shock Further demonstration of fatal shock Average working conditions with 120-volts Person is perspiring Average resistance is 1000-ohms from hand-to tohand 250 ohms 500 ohms 250 ohms 1000 ohms Total

Electrical Shock Further demonstration of fatal shock: Ohm s s law: I = E/R or I = 120/1000 I = 0.12 amps or 120 ma Will probably cause ventricular fibrillation

Electrical Shock Some ways of prevention: Insulation Guarding Grounding Electrical protective equipment Safe work practices STAY OUT OF THE CIRCUIT Perform a Shock Hazard Analysis NFPA 70E 2004: 110.8(B) 130.2 CSA Z462 (Pending)

Electrical Arc-Flash A large number of serious electrical injuries involve burns from electric arcs Primarily from ignition of clothing Product of: Short-circuit current Clearing time or arc duration Proximity to the worker Misconception that the arc hazard is condition of only high voltage

Electrical Arc-Flash Possible to generate higher energy from low- voltage sources than from high-voltage Arc temperatures can reach about 20,000 0 C Approximately 36,000 0 F Three different issues with an arc: Incident energy 1.2 cal/cm 2 (173 0 F or 78.3 0 C @ 0.1 sec.) - onset of 2 nd degree burn Temperature 203 0 F or 95 0 C @ 0.1 sec. (1.6 cal/cm 2 )- incurable (3 rd degree) burn Blast or explosion

Video of Test Shot 3 Phase, 600V Arc In 20 Inch Cubic Box 1.25" Electrode Gap 6 Cycle Arc Bolted Fault - 36.3 ka Arc Current - 28.6 ka Arc Power - 11.7 MW Incident Energy @ 2 Feet - 6.1 cal/cm 2 Not in text for example only

Electrical Arc-Flash Perform a Flash Hazard Analysis Establish the Flash Protection Boundary NFPA 70E-2004: 110.8(B) & 130.3 IEEE 1584 CSA Z462 (Pending) Treatment of arc burns is lengthy Debridement Skin grafting Reconstructive surgery Physical trauma Infection is common

Electrical Arc-Flash Burn Injury - Probability of Survival % Survival 100% 80% 60% 40% 20% 0% 20-29.9 30-39.9 40-49.9 50-59.9 Age Range - Years 25% Body Burn 50% Body Burn 75% Body Burn American Burn Association 1991-1993 1993 Study

Electrical Arc-Blast Copper vaporized by electrical arc expands 67,000 times (1 in. 3 copper = 1.44yds. 3 vapor) Expansion produces explosion with: Droplets of molten metal Plasma Fragmented metal High temperatures Pressure on the body

Pressure vs. Distance from Arc

Electrical Arc-Blast Pressures from a 25,000 amp fault: (human body is approximately 3 sq. ft.) 1-foot - 325 lbs./sq. ft. = 975 on body 2-feet - 160 lbs./sq. ft. = 480 on body 5-feet - 70 lbs./sq. ft. = 210 on body 50-feet - no pressure = 0 on body

Electrical Arc-Blast DO NOT USE electrical equipment rooms for: Offices Walkways Storage rooms Break rooms Maintenance shops

FIGURE 12 Switchgear Room Post Arc Flash and Fire 07-0007

Electrical Hazards Analysis NFPA 70E-2004 requirements Shock hazard analysis [110.8(B) & 130.2] Limited Approach Boundary Restricted Approach Boundary Prohibited Approach Boundary Flash Hazard Analysis [110.8(B) & 130.3] Flash Protection Boundary

Approach & Protection Boundaries Limited Approach Boundary Restricted Approach Boundary Prohibited Approach Boundary Energized part or Initiation of arc Flash Protection Boundary

Flash Hazards Analysis A Key component of the Flash Hazard Analysis is the over-current protective device clearing time. Primarily circuit breakers and relays Primary focus should be on the maintenance issues of circuit breakers and relays

Flash Hazards Analysis Molded case and low-voltage power circuit breakers (600-volts or less) will generally clear a fault condition in 3 to 8 cycles. The majority of older medium-voltage circuit breakers (2300-volts or greater) will clear a fault in around 8 cycles with the newer ones clearing in 3 to 5 cycles.

Flash Hazards Analysis Protective relays will generally add approximately 3 to 4 cycles to the clearing time of the medium-voltage circuit breaker. Where proper maintenance and testing are not performed, extended clearing times could occur creating an unintentional time delay that will effect the results of a flash hazard analysis.

Flash Hazards Analysis All maintenance and testing of the electrical protective devices must be accomplished in accordance with the manufacturer s s instructions. The NETA Maintenance Testing Specifications for Electrical Power Distribution Equipment and Systems 2001 Edition is an excellent source of information for performing the required maintenance and testing of these devices.

Flash Hazards Analysis Since most molded-case circuit breakers have riveted frames, maintenance is limited. We can help ensure appropriate clearing times through: proper mechanical mounting maintaining electrical connections periodic manual operation

Flash Hazards Analysis All other molded-case circuit breakers that are UL approved are factory-sealed to prevent access to the calibrated elements. Broken seals would indicate the integrity of the device could be questionable

Flash Hazards Analysis Molded case circuit breakers installed in a system are often forgotten. Without proper attention, there are several things that can go wrong. Circuit breakers can fail to open due to a burned out trip coil, or Fail because the mechanism is frozen due to dirt, dried lubricant, or corrosion.

Flash Hazards Analysis Most manufacturers recommend that if a molded-case circuit breaker has not been operated within as little as six months time, it should be removed from service and manually exercised several times.

Flash Hazards Analysis Manually exercising helps: keep the contacts clean due to their wiping action ensures that the operating mechanism moves freely This exercise DOES NOT operate the mechanical linkages in the tripping mechanism

Flash Hazards Analysis The only way to properly exercise the entire breaker operating and tripping mechanisms is to: remove the breaker from service and test the overcurrent and short-circuit tripping capabilities A stiff or sticky mechanism can cause an unintentional time delay in its operation under fault conditions and increase the arc/flash incident energy level.

Flash Hazards Analysis Several studies have shown that low- voltage power circuit breakers,, which were not maintained within a 5-year 5 period, have a 50% failure rate. Maintenance will generally consist of keeping them clean and properly lubricated. The environment can have an impact on maintenance intervals

Flash Hazards Analysis Most of the inspection and maintenance requirements for low-voltage power circuit breakers also apply to medium- voltage power circuit breakers. Most manufacturers recommend that these breakers be removed from service and inspected at least once per year. Always follow the manufacturer s instructions.

Flash Hazards Analysis Relays continuously monitor complex power circuit conditions, such as: current and voltage magnitudes, phase angle relationships, direction of power flow, and frequency. When an abnormal condition is detected, the relay responds and causes a portion of the system to be deenergized via the circuit breaker.

Flash Hazards Analysis The ultimate goal of protective relaying is to disconnect a faulty system element as quickly as possible. Sensitivity and selectivity are essential to ensure that the proper circuit breakers are tripped at the proper speed to: clear the fault, minimize damage to equipment, and reduce the hazards to personnel.

Flash Hazards Analysis Several things may happen to prevent primary relaying from disconnecting a power system fault: Current or voltage supplies to the relays are incorrect. DC tripping voltage supply is low or absent. Protective relay malfunctions. Tripping circuit or breaker mechanism hangs up. Relays not properly set per RFCS

Flash Hazards Analysis Most manufacturers recommend that periodic inspections and maintenance be performed at intervals of one to two years.

Flash Hazards Analysis The periodic inspections, maintenance, and testing are intended to ensure that the protective relays are functioning properly and have not deviated from the design settings. If deviations are found, the relay must be retested and serviced as described in the manufacturer s s instructions.

Flash Hazard Analysis All calculations for determining the incident energy of an arc and for establishing a flash protection boundary require the protective device clearing time. This clearing time is derived from the engineering coordination study, which is based on what the protective devices are designed to do.

Flash Hazard Analysis Maintenance is a very critical part of the flash hazard issue. The information provided here clearly indicates the need for a preventive maintenance program on these circuit protective devices. Evidence has proven that inadequate maintenance can cause unintentional time delays in the clearing of a short circuit condition.

Flash Hazard Analysis If, for example, a low-voltage power circuit breaker had not been operated or maintained for several years and the lubrication had become sticky or hardened, the circuit breaker could take several additional cycles, seconds, minutes, or longer to clear a fault condition.

Flash Hazard Analysis A Flash Hazard Analysis is performed based on what the system is suppose to do. An unintentional time delay, due to a sticky mechanism on a breaker, can extend the clearing time from 5 cycles to 30 cycles, increasing the incident energy the worker would be exposed to. This could seriously injure or kill the worker because he/she would under protected.

Flash Hazard Analysis Arc/Flash situation: 20,000-amp short-circuit, 480 volts, 3-inch arc gap, the worker is 18 inches from the arc, with a 5 cycle clearing time for a 3-phase 3 arc in a box (enclosure). Next slide illustrates this:

Conclusion Circuits operating at 50-volts or higher Three Hazards of Electricity Electrical Shock Electrical Arc-Flash Electrical Arc-Blast Best way to avoid exposure to these hazards: STAY OUT OF THE CIRCUIT

Conclusion With the proper mixture of common sense, training, manufacturers literature and spare parts, proper maintenance can be performed and power systems kept in a safe, reliable condition.

Conclusion Circuit breakers, if installed within their ratings and properly maintained, should operate trouble-free for many years. However, if operated outside of their ratings or without proper maintenance, catastrophic failure of the power system, circuit breaker, or switchgear can occur causing not only the destruction of the equipment but serious injury or even death of employees working in the area.