Adjustable swirl diffuser ODZA TECHNICAL DATA

Similar documents
Supply air diffuser ROFB, RPFB

CHILLED BEAM FLEXICOOL IQID

Chilled beam iq Star WEGA II

CALMO

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES

Round duct nozzle jet diffuser Model DSA-RR

CADENZA

TECHNICAL DESCRIPTION

Krantz Components. Multifunction Sail AVACS. Cooling and Heating Systems

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D

CEILING DIFFUSERS technical CONTROL THE AIR YOU BREATHE. types -CD, CAB. Europair Africa a division of Performancair Products Africa (Pty) Ltd

Automatic extractor outlet

LindabSolus. Supply air beam. lindab we simplify construction

HCD HIGH CAPACITY DRUM LOUVER

vento specification sheet

Air distribution systems Circular displacement outlet with adjustable damper VA-ZD...

Sizes JNŽ-6, ANŽ-3, ANŽ-4

LindabPremax. Supply air beam. lindab we simplify construction

LindabPremum. Supply air beam. lindab we simplify construction

for Asia / Pacific Radial outlet RA-N3... DS 4134 AUS /

-4.~1~ S L 0 T D I F F U S E R S

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Measuring range Δp (span = 100%) Pa

microtec 865 New from Beissbarth: wheel-balancing with the electronic easyfix data recording arm. All the best for your automobile service.

Centriflow Plus High-pressure plug fan - Technical Data

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Automatic balancing valves

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

RA-N radiator valves with integrated presetting and self-sealing tailpiece

Vertical Bladder Tanks

Ducted Reverse Cycle Air Conditioning of Distinction

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Air screwdrivers CSEZ

Vibration isolated tables. Individually tailored to your requirements.

AIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS

MANUAL. Verkstadsvagen 2, SE SKELLEFTEA, Sweden Tel , Fax P17W45_MPREX_F_EN

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Technical Documentation Linear diffusers series LDB

Less power great performances

15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Gas Cylinder Cabinets

CR Series. Special doors for clean room application

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Micro grippers HGPM/HGWM

Automatic balancing valves ASV

Atmospheric Vent Silencers. Industrial & Marine Silencers

Fire- & smoke- tight sliding door FST High quality for demanding architecture

VARIABLE AIR FLOW REGULATOR

Z5160 Load adapter Mounting instructions (1.2 EN)

PRODUCT CONFIGURATOR AT mcr Monsun. smoke extraction and air supply axial-flow fans

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

AXIAL FLOW FANS GENERAL INFORMATION

Gas Pressure Switch for DMV safety shutoff valves

VZL valve - 2/3/4-way

CALEFFI. Ball zone valves. series /03 GB

Safety shut-off valve S 100. Product information

CFSW. Hinges with built-in safety multiple switch

Pressure Independent Control Series

HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR

Parallel grippers HGPM, micro

WaterSource Heat Pump Hose Kit Performance Specification-Summary

INDUSTRIAS IBAIONDO, HYDROPNEUMATIC TANKS

Sand Trap Louvers. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) SAND TRAP LOUVERS

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Safety shut-off valve S 50. Product information

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

Directional Control Valves Series VA13 and VA15 3- and 5-port valves, G1/8

CompacSas BA. Comfort and design for high-security access

KM/ Stainless steel air bellows Single acting Ø 220 to 400 mm

Uniflair LE TDAR-TUAR

Pressure independent control valve (PICV) FLOWMATIC

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

10.2. Basketball Single Post System

Louvre panels & grilles. Self-assembly

TA-FUSION-P. NPT threads / ANSI flanges

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

Ultrasonic level transmitter and indicator

Evaporator (DX) Freon Applications 1 12 Tons MHF

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS

Order No Projection Backboard

Safety Shut-Off Valve HON 720

INSTRUCTION MANUAL Pressure Relief Device LPT

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

A18W35_MASE 130_F_EN MANUAL

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

STAD. Balancing valves DN (MD60, MD61, MD62)

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

The elegant solution for enhanced security. Manual Attack Resistance. Ballistic Resistance. Recyclable product. Eco-design. exit

Pressure Switch for gas and air

Screw Compressors 11-22kW

Transcription:

Adjustable swirl diffuser ODZA TECHNICAL DATA

2 Adjustable swirl diffuser ODZA Adjustable ceiling swirl diffuser ODZA is intended for commercial and industrial buildings with a large room volume and high ceiling interiors, for example market halls, warehouses, factories etc. The function of the diffuser can be adapted to both summer and winter conditions. The air diffusion pattern is controlled by changing the angle of the blades. Half of the blades are fixed as the rest can be rotated. At the end of movement they touch the fixed blade surface. As a result of that, between the fixed and movable blades the holes are created and diffuser starts to work with nozzle effect. Thanks to that it can achieve very long vertical throw length. Swirl diffuser ODZA has an air flow range of between 39 and 2500 l/s (140-9 000 m 3 /h) and has an installation height between 3 and 28 m. ODZA can be adjusted manually or with the help of an electric or thermal element. QUICK SELECTION Size Air flow l/s m 3 /h Installation height H P, m Pressure drop Pa ODZA-25 39-389 140-1400 3-11 4-367 ODZA-31 56-556 200-2000 3-13 3-278 ODZA-40 153-1111 550-4000 3-20 8-428 ODZA-50 222-1667 800-6000 4-23 8-426 ODZA-63 361-2500 1300-9000 5-28 8-368 SPECIFICATIONS Continuous regulation of the throw direction, from horizontal to vertical Very long vertical throw Very efficient in heating high rooms Flush to the ceiling or freely hanging installation Installation directly to the duct or via plenum box PRODUCT CODE EXAMPLE Swirl diffuser ODZA-50-4-1 Terminal of size 50 adjustable by Belimo electric actuator, painted in RAL 9010 colour. Connection box SKKU-50-50-1-0 Duct connection size 50, diffuser size 50, with sound attenuation material, without damper.

Adjustable swirl diffuser ODZA 3 THROW LENGTH ODZA-25 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) ODZA-25 THROW LENGTH FOR HEATING FUNCTION (BLADES SET IN MIDDLE POSITION - AIR SUPPLY AT 45 O ANGLE) L 0,2 [m]

4 Adjustable swirl diffuser ODZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL ODZA-25 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) Horizontal throw L 0.2 has been measured for freely hanging case ODZA-25 AIR FLOW, PRESSURE DROP, SOUND LEVEL [db(a)] - HT [db(a)] - VT [db(a)] - MT P [Pa] 8 HT = horizontal air supply VT = vertical air supply MT = blades set in middle positiion - air supply at 45 o angle)

Adjustable swirl diffuser ODZA 5 THROW LENGTH ODZA-31 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) ODZA-31 THROW LENGTH FOR HEATING FUNCTION (BLADES SET IN MIDDLE POSITION - AIR SUPPLY AT 45 O ANGLE) L 0,2 [m]

6 Adjustable swirl diffuser ODZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL ODZA-31 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) Horizontal throw L 0.2 has been measured for freely hanging case ODZA-31 AIR FLOW, PRESSURE DROP, SOUND LEVEL P [Pa] [db(a)] - HT [db(a)] - VT [db(a)] - MT 8 HT = horizontal air supply VT = vertical air supply MT = blades set in middle positiion - air supply at 45 o angle)

Adjustable swirl diffuser ODZA 7 THROW LENGTH ODZA-40 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) ODZA-40 THROW LENGTH FOR HEATING FUNCTION (BLADES SET IN MIDDLE POSITION - AIR SUPPLY AT 45 O ANGLE) L 0,2 [m]

8 Adjustable swirl diffuser ODZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL ODZA-40 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) Horizontal throw L 0.2 has been measured for freely hanging case ODZA-40 AIR FLOW, PRESSURE DROP, SOUND LEVEL [db(a)] - HT [db(a)] - VT [db(a)] - MT P [Pa] 8 HT = horizontal air supply VT = vertical air supply MT = blades set in middle positiion - air supply at 45 o angle)

Adjustable swirl diffuser ODZA 9 THROW LENGTH ODZA-50 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) ODZA-50 THROW LENGTH FOR HEATING FUNCTION (BLADES SET IN MIDDLE POSITION - AIR SUPPLY AT 45 O ANGLE) L 0,2 [m]

10 Adjustable swirl diffuser ODZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL ODZA-50 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) Horizontal throw L 0.2 has been measured for freely hanging case ODZA-50 AIR FLOW, PRESSURE DROP, SOUND LEVEL [db(a)] - HT [db(a)] - VT [db(a)] - MT P [Pa] 8 HT = horizontal air supply VT = vertical air supply MT = blades set in middle positiion - air supply at 45 o angle)

Adjustable swirl diffuser ODZA 11 THROW LENGTH ODZA-63 THROW LENGTH FOR HEATING FUNCTION (VERTICAL DIFFUSION PATTERN) ODZA-63 THROW LENGTH FOR HEATING FUNCTION (BLADES SET IN MIDDLE POSITION - AIR SUPPLY AT 45 O ANGLE) L 0,2 [m]

12 Adjustable swirl diffuser ODZA THROW LENGTH, AIR FLOW, PRESSURE DROP, SOUND LEVEL ODZA-63 THROW LENGTH FOR COOLING FUNCTION (HORIZONTAL DIFFUSION PATTERN) Horizontal throw L 0.2 has been measured for freely hanging case ODZA-63 AIR FLOW, PRESSURE DROP, SOUND LEVEL [db(a)] - HT [db(a)] - VT [db(a)] - MT P [Pa] 8 HT = horizontal air supply VT = vertical air supply MT = blades set in middle positiion - air supply at 45 o angle)

Adjustable swirl diffuser ODZA 13 DIMENSIONS AND INSTALLATION ALTERNATIVES DIMENSIONS AND WEIGHT - MANUAL VERSION ØD2 INSTALLATION ALTERNATIVES Directly to circular duct ØDN ØD1 Note! Length of the straight duct before diffuser shouldn t be shorter than 0,8xØDN. SKKU connection box 12 K L x B 80 min 25 ODZA-25, 31, 40 H ØD1 ØD2 1/2H 50 ODZA-50, 63 Connection box SKKU, model 1:1 Size ØD1 ØD2 H Weight (mm) (mm) (mm) (kg) 25 373 284 176 2,0 31 468 313 210 3,6 40 625 397 271 4,0 50 770 497 297 5,0 63 930 627 350 9,0 Size ØD1 ØD2 H L B K (mm) (mm) (mm) (mm) (mm) (mm) 25-25 249 250 295 700 570 260 31-31 314 315 360 700 570 310 40-40 399 400 455 700 570 300 50-50 499 500 555 700 570 350 63-63 629 630 685 800 800 400 Connection box SKKU, model 1:2 Size ØD1 ØD2 H L B K (mm) (mm) (mm) (mm) (mm) (mm) 20-25 199 250 245 650 480 218 25-31 249 315 295 700 570 260 31-40 314 400 360 700 570 310 40-50 399 500 455 700 570 350 50-63 499 630 555 800 800 400

14 Adjustable swirl diffuser ODZA DIFFUSION PATTERN AND ADJUSTMENT DIFFUSION PATTERNS Cooling function, horizontal flow t N = -12K Heating function, vertical flow t N = +15K Combined function, diagonal flow ADJUSTMENT The change of diffusion pattern is made via turning rotating blades. horizontal diffusion pattern vertical diffusion pattern combined diffusion pattern Depending on version, the change of diffusion pattern can be done: manually, via the handle placed in the middle of diffuser, automatically, via electric actuator, automatically, via thermal element which reacts to the supply air temperature.

Adjustable swirl diffuser ODZA 15 AIR FLOW VOLUME AND DISTANCE BETWEEN DIFFUSERS MAXIMUM AIR FLOW VOLUME* *Assuming that average metabolic activity level is 2.0 met and clothing insulation is 0.5 0.6 clo. Premises which meet these conditions are e.g. sport halls, warehouses and light industry halls. MINIMUM DISTANCE BETWEEN DIFFUSERS

16 Adjustable swirl diffuser ODZA SOUND DATA, PROJECT DESIGN EXAMPLE PROJECT DESIGN EXAMPLE Definitions q tot total air flow m 3 /h q D diffuser air flow m 3 /h q V volume air flow m 3 /h x m 2 A served floor area m 2 H p installation height above the floor m t distance between diffuser m t min minimum distance between diffusers m t r room temperature C t v temperature difference between the supply air and the room air K L 0,2 throw equivalent to 0.2 m/s in final velocity m Assumptions Total air flow q tot = 30 000 m³/h Served floor area A = 2000 m 2 Room temperature t r = 24 C Required throw length L 0.2 = 10 m 1. Selection of diffuser, size ODZA-50 Assumed number of diffusers, n 12 pcs. Diffuser air flow, q D 2 500 m 3 /h Assumed t v for heating +10 K Min air flow taken from the graph for the diffuser heating function 2 140 m 3 /h Assumed distance between diffusers, t 12.5 m Volume air flow, q V (from graph) 16.0 m 3 /h x m 2 Max volume air flow, for H p = 11.8 m and t r = 24 C 79 m 3 /h x m 2 Min distance between diffusers, t min where q Vmax = 79 m 3 /h x m 2 is not exceeded 5.6 m SOUND POWER LEVEL Size DEFINITIONS Correction of sound level K oct in db for octave bands, mean frequency (Hz) 63 125 250 500 1000 2000 4000 8000 25 15 6 1 3 0-9 -14-15 31 15 6 1 3 0-9 -14-15 40 9 4 1 2 1-9 -6-20 50 13 8 2 3-1 -9-14 -15 63 13 8 2 3-1 -9-14 -15 The sound power levels for different octave bands are obtained by adding together the sound pressure level L A10, in db(a), and the corrections K oct for the octave bands in the table with the help of the following formula: L W = + K oct Correction K oct is the mean value for the range of application of ODZA. V air flow l/s, m 3 /h Δp t total pressure drop Pa L 02 throw m sound pressure level with a room attenuation of 4 db (10 m 2 room absorption area) db(a) L W sound power level db K oct octave band correction db 2. Selection of diffuser, size ODZA-31 Assumed number of diffusers, n 22 pcs. Diffuser air flow, q D 1 363 m 3 /h Assumed t v for heating +10 K Min air flow taken from the graph for the diffuser heating function 1 330 m 3 /h Assumed distance between diffusers, t 9.0 m Volume air flow, q V (from graph) 16.8 m 3 /h x m 2 Max volume air flow, for H p = 11,8 m and t r = 24 C 79 m 3 /h x m 2 Min distance between diffusers, t min where q Vmax = 71 m 3 /h x m 2 is not exceeded 4.2 m You can obtain 3D visualizations of diffusion patterns from our online selection software called SELECT.

Adjustable swirl diffuser ODZA 17 GENERAL EXECUTION AND FUNCTION ODZA is a swirl ceiling mounted supply air terminal that is recommended to be mounted with SKKU plenum box or directly to the duct. Its diffusion pattern can be changed from horizontal to vertical in order to adapt summer or winter conditions. Position of the blades can be controlled manually or automatically. In latter case, it is available with regulation via thermal element or electric actuator. Patented method of controlling supply air direction, ensures very good performance in terms of vertical throw length. Smaller sizes of SKKU plenum box (duct connection size up to 315mm) features an extremely quiet patented measurement and adjustment ZAEF damper for multipoint measuring with balanced and accurate values. The adjustment handle of the measurement and adjustment damper has a position indicator and a locking device. The measurement and adjustment damper can be easily removed (only 1:2 model) for inspection and cleaning without changing the setting. SKKA connection box is available with or without sound attenuation material. In each plenum box, there are lugs attached to the walls for hanging purposes. ODZA is fixed to the box by screws. MATERIAL AND SURFACE FINISH Diffuser is made from steel and aluminium sheet. Plenum box is made from steel sheet. ODZA is powder-coated for a high surface finish. The standard colour is RAL 9010, 30% of gloss. Sound attenuation lining is made of elastomeric foam based on synthetic rubber. Electric actuators used in automatic version comply with RoHS directive. INSTALLATION, ADJUSTMENT AND MAINTENANCE The instructions for installation, adjustment and maintenance are available at www.flaktgroup.com TECHNICAL DATA AND DIMENSIONING For complete design details, please see the Fläkt Woods product selection program SELECT. The program can be found on the Internet at www.flaktgroup.com. SPECIFICATIONS TEXT EXAMPLE The ODZA is a ceiling supply swirl diffuser that consists of external casing and internal movable blades, which position can be set due to actual demand in terms of diffusion pattern shape. Unit can be controlled manually or automatically via thermal elements or electric actuator. The SKKU plenum box includes effective sound attenuation elements.

18 Adjustable swirl diffuser ODZA PRODUCT CODE AND ACCESSORIES PRODUCT CODE ACCESSORIES Swirl diffuser ODZA-aa-b-c Damper BDEP-1-bbb-c Size (aa) 25, 31, 40, 50, 63 Flow pattern regulation (b) 1 = manual 2 = by thermal element 4 = by Belimo electric actuator Colour (c) 1 = standard RAL 9010 X = any other colour from RAL palette Size (bbb) 025-063 Model (c) 1 = standard Connection box 1:1 SKKU-aa-bb-c-d Size (aa-bb) 25-25, 31-31, 40-40, 50-50, 63-63 (duct connection size - diffuser size) Sound attenuation material (c) 0 = without 1 = with Damper (d) 0 = without 2 = measurement and adjustment damper ZAEF (only for duct connection sizes 25 and 31) Connection box 1:2 SKKU-aa-bb-c-d Size (aa-bb) 20-25, 25-31, 31-40, 40-50, 50-63 (duct connection size - diffuser size) Sound attenuation material (c) 0 = without 1 = with Damper (d) 0 = without 2 = measurement and adjustment damper ZAEF (only for duct connection sizes 20, 25 and 31)

Adjustable swirl diffuser ODZA 19

FG_DC_9367GB_ODZA_TE_20180320_R0 Copyright 2018 FläktGroup WWW.FLAKTGROUP.COM ODZA 9367 FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. PRODUCT FUNCTIONS BY FLÄKTGROUP Air Treatment Air Movement Air Diffusion Air Distribution Air Filtration Air Management & ATD s Air Conditioning & Heating Controls Service» Learn more on www.flaktgroup.com or contact one of our offices