Guidelines for Property owners dealing with Blocked Ducting.

Similar documents
Blue Whale Spa :- Site Preparation and Delivery

FNFB-30 (30 FT FIELDPRO FOOTBALL BACKSTOP SYSTEM) Installation Instructions

Field Instruction. Protect Horizon Power employees and contractors from a potential hazard.

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

Pools and powerlines. Things to know when planning or designing swimming pools for ACT backyards.

Residential and Small Commercial

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

EASY AND SAFE WIRING DEVICES COMPLIANT WITH SAFETY STANDARDS. Get detailed information on many digital or printed supports or contact our sales team

BALL STOP INSTALLTION GUIDE

IRATA International code of practice for industrial rope access. Part 3: Informative annexes Annex H: Equipment inspection checklist

Lecture 10 : Sewer Appurtenances

List all key terms and acronyms used in the procedure, and their definitions.

CORPORATE SAFETY MANUAL

Comments for CPUC Utility Pole Census and Competitive Access Order Instituting Investigation,

Loopie Sling SP-18(0718)

GAS PIPELINE SAFETY GUIDE.

8. Tracking, Marking and Locating. 8. Tracking, Marking & Locating your FTTx Network

Method statement for. The installation of. Precast Concrete Piles. (Site Name).

CABLEGRIPS GALVANISED STAINLESS ARAMID FOR QUICK AND EFFICIENT CABLE INSTALLATION AND SUPPORT

ARCA Guidance Note. Guidance on Air Management in Asbestos Enclosures

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

An Update on IEC TC 81 (Lightning Protection)

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

URBAN SEARCH AND RESCUE - OPERATIONS Undertake structural collapse rescue as part of an urban search and rescue (USAR) operation

Work Standard CABLE PULLING OPERATIONS

AutoChanger Installation & User Guide Issue 2

Original Date of Issue: 04/09

You stand for our success

CS10 # Network Safety Performance Objectives (2016)

Typical Strength of Glued Connection. Typical Strength of Screwed Connection

Flamco Flamco-Fill STA Flamco-Fill STM

Retrofitting kit New Emax Direct Replacement of Megamax and Novomax

USE AND MAINTENANCE LIGHT TOWER

Date: Signature: Yes No

Proof load is the load applied in performance of a proof test. Proof test is a nondestructive tension test performed by the sling manufacturer or an

cricket Premier Portable Cage Winch System Heavy Duty Parks Parks Cages Wooden Bays Stumps Netting Sundries cricket

1. What is the top priority when working on Canadian Pacific (CP) property? 2. When working on CP property what must all Contractors comply with?

gaf traffic 2015 capability statement

Electrical Safety Work Practices

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

Installation and Operation Manual

HYDRAULIC TOOLS: CABLE CUTTER CC0260

Part 3: Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communication Lines

Precision Liquid Settlement Array Manual

Health & Safety: Electrical safety

PF30 Inspection & Maintenance Manual

COUNCIL POLICY. Document No: CPL260.5 Approval Date: 23 March 2010 Obstruction

GL0052K Envireau Mono-Tech Rainwater Recovery System Installation & Operation Guidelines

USE OF REELS IN DIVING

Working with Grantors

SpanSet Gotcha CRD User Instructions. SpanSet Certified Safety

CONTRACTOR SAFETY RULES

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

NCR SelfServ 38 ATM. Site Preparation B D

INSTRUCTION MANUAL Pressure Relief Device LPT

SDX Submersible Depth Transmitter User Manual

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Safe Schools: A Health and Safety Check

Working Alone. Latest revised date: October 26, 2011 Page 1 of 7 Prepared by: Department of Health & Safety S-014

Siting and Installation Manual

CITY OF TORONTO. BY-LAW No

Information Systems ISM 3011

SEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats

Egatube Conduit and Fittings

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

DESIGN CRITERIA DIVISION 4900 TRAFFIC SIGNALS

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

THOR 10 HAMMER CAGE INSTRUCTIONS

Safety System Installation Guide for ARE Wind Poles

LOCK-OUT / TAG-OUT SYSTEM & PROCEDURE

Excavation safety around natural gas

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

FIRE & LIFE SAFETY STANDARD

HV Spiker Kit - CSTE. 30 th April 2014

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

F OVERHEAD CONSTRUCTION & STRINGING EQUIPMENT GRIP SELECTION

Excavation safety around natural gas

GOTCHA CRD. Rescue, hoisting and abseiling equipment EN341 / EN1496 CE0158 TECHNICAL DATA

SWMS No 012 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 6

HOW TO PREPARE FOR THE LEVEL A CRANESAFE CERTIFICATION ASSESSMENT

Height Safety Lifting Load Control Safety Management GOTCHA Rescue Range TECHNICAL DATA

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

woodlander B y w i r e r o p e i n d u s t r i e s

5 IMPLE REASONS T O SWITCH

Status Date Prepared Reviewed Endorsed Approved

CONTROL OF HAZARDOUS ENERGY (LOCKOUT/TAGOUT)

Table of Contents Documentation for PIT TROLLEY A4

Field Instruction. This instruction applies to Horizon Power employees and contractors involved in Horizon Power s underground projects.

Scope of Work for Traffic Signal and Interconnect Design Services for Santa Rosa Road

CITB Construction site safety update

BackCountry ebikes 2019 MULE Assembly

TECHNICAL DATA. Trimpac 257a. September 16, 2013

GENERAL GUIDELINES FOR PROPER RIGGING PRACTICES AND INSPECTION & REMOVAL CRITERIA FOR SLINGS PER OSHA

TECHNICAL DATA. Trimpac 256a. October 31, 2013

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)

Transcription:

Guidelines for Property owners dealing with Blocked Ducting. NOTE: Issues relating to Ducting should be resolved by a competent person or Contractor. The meanings of capitalised terms when used in this document are explained in the Acronyms section at the end of the document. For premises where Telecoms infrastructure is delivered via an underground duct, it is the responsibility of the property owner to ensure that this duct is not damaged or blocked and there is a free moving Draw Rope installed. The property owner should ensure their duct is fit for purpose in advance of placing an order, to provide adequate time to resolve any issue that might exist. Damaged or blocked ducting will prevent or delay service being installed in the premises. Duct route. The duct will run from the premises access point to the Point. The point can be either a Telephone pole or an Access box. The ends of the duct should be identified both at the premises and at the Point. Locating both ends of the duct will establish if there is a Draw Rope present. Depending on the length of the duct (> 50 m) there may one or more access boxes along the length of the duct. Each box should be opened for inspection. A Cat and Genny can be used to identify the duct route if necessary. Point (Pole) Point (Access box) Point is a pole. Probable duct route to NTP. point is an Access box.

Premises where access box is fitted and duct is fitted on external wall. Premises where access box is fitted and duct enters premises under the floor. Premises where an access box and ETU are fitted. ETU at premises with draw rope installed.

Network touch point with multiple ducts. A draw rope present in one duct. Duct at network touch point. No draw rope present. Draw Rope present (The network touch point is a pole) If there is a draw rope present then it is possible to establish if the duct is blocked by pulling the rope back and forth within the duct. This procedure should be carried out by two competent people. If the rope moves freely then the duct should be free of obstructions. This Duct can be considered Fit for Purpose for the installation of Fibre or other telecoms services. Note: (It is essential to ensure that the rope is securely fastened at both ends before carrying out this procedure to avoid inadvertently pulling the rope into the duct.) Where the duct enters the premises under the floor, the customer must locate the end of the duct internally. Otherwise it may be necessary to install a new duct between the nearest Access box and the external wall of the premises. A rope is present but it will not move freely: This duct may be blocked at some point along its length. A contractor is required to unblock the duct and ensure the Draw Rope is free moving.

Tasks involved in unblocking a duct: Locate the ends of the duct. Locate and open any access boxes along the duct route. Rod the duct from each access point. Rod will stop at point of blockage. Withdraw rod from duct and lay on ground along route of duct. Blockage will be located at the end of the rod. Civils work is required to expose the duct and unblock. An Access box should be installed at the point of the blockage. Continue this process until the duct has been Rodded from end to end. No rope present: A Draw Rope must be installed. Rod the duct. Attach a rope to the end of the rod. Pull the rope into the duct by pulling the rod out of duct. The Point is an Access box: (Not a pole) In this circumstance it will not be possible to test the draw rope if one is present. The following procedure should be followed: The duct location should be identified at the premises boundary. (Close to the NTP) Civils work should be executed to expose the duct and an Access box installed. Check the rope is free moving. (If a rope is present) Unblock duct if necessary. Install a rope if no rope is present. If installing a rope, it should be long enough to reach past the newly installed Access Box to 1 Metre past the Point. (Access box) The additional rope should be left coiled safely in the newly installed Access box. The rope should be securely fastened at both ends.

Acronyms: ETU External Termination Unit FTTH Fibre to the home. NTP Access Box Draw Rope Point Cat and Genny Telecoms connection box installed in the external wall of the premises generally when the premises is initially being constructed. (IP66 rated external junction box of dimension W 150mm x H 230mm x D 150mm.) Fibre broadband service which is delivered into the premises via a Fibre Optic cable. An access box (sometimes called a small access chamber) is a plastic or concrete structure set below ground with a lid flush to the surrounding surface to facilitate the installation and maintenance of the Telecoms duct and fibre cable. (Sometimes called the Draw Wire.) A rope (usually 6 mm nylon) inserted in a duct for the purpose of pulling a cable through the duct during service installation or maintenance. (Sometimes called the Distribution Point.) The point on the open eir network from where service will be delivered. It can be a telephone pole or an underground box or chamber. A hand held electronic device used to identify the route of underground cables.