YEOMANS SUBMERSIBLE SOLIDS-HANDLING PUMPS STANDARD SILICON CARBIDE MECHANICAL SEALS FEATURES & BENEFITS

Similar documents
Aquavar SOLO 2 Frequently Asked Questions

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

IMPORTANT SAFETY INSTRUCTIONS

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

USER MANUAL. JET TST and JET TST S.

Installation Instructions

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

100C Air Compressor Kit

Installation Operation Maintenance

TITAN FLOW CONTROL, INC.

200 PSI COMPRESSORS - MODEL NUMBERS

400C & 450C DUAL PERFORMANCE VALUE PACKS

VTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

DEVELOPING YOUR PREVENTIVE MAINTENANCE PROGRAM

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

T Y P E V S A B M S E W A G E P U M P

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Temperature Controllers

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

444C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Goulds 3296 EZMAG. Chemical Process Pump

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

200 PSI HIGH-FLOW AIR SOURCE KIT

Eaton Filtration, LLC

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

SECTION BUTTERFLY VALVES

INSTALLATION INSTRUCTIONS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

200 PSI FAST-FILL AIR SOURCE KIT

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

MODEL NUMBER: P PORTABLE COMPRESSOR

Deep Well Submersible Pump Model MSU/MSUS

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Installation Instructions

THE DISECTION of the SUBMERSIBLE MOTOR and PUMP. Deepwell Submersibles

DTG - LCD Digital Temperature Gauge USER MANUAL

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

MODEL NUMBER: P PORTABLE COMPRESSOR

Hydrogen Cooling System

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Installation Instructions

Zenit. Blue Professional Series. Submersible Electric Pumps.

! Warning, refer to accompanying documents.

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

TWISTER Low Speed Surface Aerator

UCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES

TECHNICAL DATA. Q = C v P S

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

TECHNICAL DATA. Q = C v P S

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Eaton Filtration, LLC

BACK PRESSURE / SUSTAINING

Portable Oil Lube Air Compressors

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS

FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

BACK PRESSURE / SUSTAINING

Compressor Seal Replacement and Upgrades SERVICES

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

TECHNICAL DATA. Q = C v P S

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Liquid ring vacuum pumps in compact design

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Instrument Operating Manual

Evaporator (DX) Freon Applications 1 12 Tons MHF

Maintenance handbook

Installation Instructions

RP series Rotor Pumps

TEST BENCH FOR SAFETY VALVES

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

INSTALLATION, OPERATING AND MAINTENANCE MANUAL Submersible Ballast Pump MANUFACTURED BY

Homestead Series 820 AWWA Butterfly Valves

High-performance submersible pressure transmitter For level measurement Model LH-10

Type BBS-03, BBS-05, BBS-06, BBS-25

WHEATLEY Series 500 Swing Check Valve

Cast iron swing check valve. BS EN 12334:2001 PN16

AquaDDM. Direct-Drive Mixer. Often Imitated Never Duplicated

Installation Instructions

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

Pressure Independent Control Series

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MAINLINE MLA14 AIR CONDITIONERS

Transcription:

YEOMANS SUBMERSIBLE SOLIDS-HANDLING PUMPS STANDARD SILICON CARBIDE MECHANICAL SEALS FEATURES & BENEFITS Yeomans submersible motors are furnished with a tandem mechanical seal arrangement consisting of two (2) independent Type-21 or approved equivalent mechanical seals running in an oil reservoir. The Type-21 mechanical seal is the industry standard for original equipment manufacturers. The seals are readily available from many commercial sources on a worldwide basis thereby providing the customer with easy access to repair or replacement seal parts. The modest cost of Type-21 seals helps reduce the customer s spare parts expense. Non-standard, Non- U.S. manufactured seal designs supplied by some competitors can be very costly to replace and hard to find from local sources. For sewage and wastewater applications, the standard Silicon Carbide vs. Silicon Carbide lower seal face combination is the ideal choice. This hard seal face combination is suitable for most applications including abrasion service with high grit content, standard water, wastewater, high temperature service (up to 90 C), and most chemicals. On the standard seals, the secondary sealing bellows (flexible elastomer bellows) and the stationary cup are Viton material for maximum performance. All metal seal parts, including the spring, are made of Stainless Steel. The standard upper seal is constructed using Silicon Carbide vs. Carbon because the environment of the upper seal is an oil bath and is normally not subjected to the pumped media. Please refer to the following drawing and notations for detail of specific seal features and benefits: 1. The single coil-spring and flexible bellows design provides self-alignment which automatically adjusts to compensate for shaft endplay, run out, primary sealing ring wear, reverse pressure and equipment tolerances. This feature will help increase the seal life and prevent premature failure. 2. The drive band and retainer distribute drive loading evenly and eliminate over-stressing of the flexible elastomer bellows. The head design prevents solids from dislodging the seal face, allows the seal to withstand higher pressure and rotational speed and eliminates the metal shell from contacting the seal ring. 3. The primary and mating seal faces are lapped to 3-helium light bands (33 millionths of an inch) flatness to provide effective sealing and leakage protection. Both primary and mating ring are made of solid-block construction for greater reliability and longer service life compared to the soldered, welded or sprayed hard-face designs used by other manufacturers. PAGE E001

YEOMANS SUBMERSIBLE MOTORS FACTORY TESTING AND RATING STANDARDS All Yeomans submersible motors are manufactured and tested in a controlled work cell environment in our Aurora, Illinois factory. Each rotor core is visually inspected for complete filling of the die-cast end rings and fan blades. Correct core length is verified by measurement. The rotor is then heated and pressfit onto a cooled precision-machined one-piece stainless steel shaft and the assembly is then machined and balanced as a unit. The stator assembly receives a quick, high-voltage surge test (approximately 2500 volts peak) to each phase in sequence, and the decay of the surge through the windings is integrated by the tester and compared phase to phase. This test checks for proper connection, impedance balance between the phases and minor or impending short circuits in the windings. The D.C. resistance of each phase is also checked against the calculated resistance value for the stator and for balanced resistance between each phase. The finished rotor and stator unit is then assembled into a central motor housing unit. The motor assembly is then subjected to a High-Potential (Hi-Pot) Test. An A.C. voltage of 2000 volts is applied between the winding and ground to test the integrity of the insulation between the winding and core iron. Any breakdown of the insulation causes the motor to be rejected. Each Yeomans motor is designed, built and tested in strict accordance with the standards of the latest NEMA MG-1 design criteria for Design B motors. All nameplate ratings are based on a 40 o C ambient, Class H insulated (Class F for 140 frame), totally enclosed non-ventilated motor of explosion-proof design. Other insulation systems are available upon request. Yeomans subscribes to a design and sales philosophy of providing the user with a recognizable and common nameplate rating system. Unlike the Pump Industry, which adheres to the Hydraulic Institute Standards or the Motor Industry, which adheres to NEMA and IEEE standards, today's wastewater industry is generally unregulated and not standardized with regard to submersible motor design and rating standards. At Yeomans we feel compelled to design our motors and pumps in accordance with NEMA and Hydraulic Institute Standards respectively. With this compliance, the user can be assured that the Yeomans equipment that is specified will meet or exceed the common, but specific, standards that they would expect from any other type of pump or motor supplier whether it be for a wastewater, process or clean liquid application. NEMA standards require specific limits for these types of machines with regard to Locked Rotor Amps, Torque, Breakdown and Pull-Up Torque. Specifying and demanding 40 o C ambient, NEMA MG-1 design limits on totally enclosed non-ventilated motors is common practice in the North American market. Yeomans strictly practices these limits and strongly suggests they also be the standard for motor ratings in the submersible wastewater pump market. PAGE E003

Submersible Solids-Handling Pumps Minimum Submergence Considerations Proper design and operation of submersible pump systems necessitates consideration of minimum submergence requirements. The water level in the wet-well must normally be maintained at a minimum level for two primary reasons: 1- Prevention of motor overheating 2- Prevention of vortexing and associated problems From experience, many customers recognize the concern about motor overheating but fail to understand the concern about prevention of vortexing and the associated pump damage that can occur. In this paper we will address both issues and offer recommendations to help prevent both problems. 1- Prevention of motor overheating Conventional submersible non-clog pump motors are air-filled non-jacketed type designed to be cooled by convection heat transfer to the surrounding media. Typically, these motors are conservatively rated for continuous operation in a fully submerged condition or for at least 15 minutes in a non-submerged condition. The minimum recommended submergence to prevent overheating will normally be noted in the pump manufacturer s product information. A common question: "But what if my pump occasionally runs non-submerged for longer than 15 minutes? Will it overheat and be damaged"? Answer: No. Due to varying wet-well levels and inflow conditions, there may be occasions when the pump motor may be partially or fully non-submerged for periods longer than 15 minutes. To prevent any motor damage due to overheating, Yeomans pumps are equipped with three (3) normally-closed, automatic-reset thermostats connected in series and embedded in adjoining phases of the motor stator windings. Should the motor winding temperature rise excessively, the thermostats will open before the temperature can reach a level that can cause damage to the motor. When the thermostats open, power to the motor is interrupted. When the motor has cooled down, the thermostats automatically reset and the pump can resume normal operation. Caution: This should not be understood to mean that a submersible pump can be run for extended periods of time without adequate suction conditions, as that is detrimental to the pump seals. For applications requiring the motors to operate in a non-submerged condition for sustained periods longer than 15 minutes, four (4) primary methods have been developed for motor cooling: A- Oversizing of conventional submersible motors For low horsepower applications, it is normally cost effective to utilize conventional non-jacketed submersible motors that are de-rated for continuous-in-air service. For example, a typical 7-1/2 HP, 4- pole non-jacketed submersible motor may, in some cases, be de-rated and nameplated at 5HP for continuous-in-air service. (The pump motor manufacturer should be consulted for any specific application.) For medium and larger horsepower sizes, this method is generally not cost effective. PAGE E005

SECTION 9000 Solids-Handling Submersible Wastewater Pumps Minimum Submergence Considerations B- By-pass (pumpage-cooled) jacketed motor design For medium and larger horsepower sizes, some manufacturers elect to offer by-pass (pumpage cooled) jacketed motor designs. These designs utilize an internal by-pass system to circulate the pumped liquid throughout the motor cooling jacket. For cleanwater applications, this is an effective and reliable method for motor cooling. For dirty water or sanitary sewage applications, clogging of the cooling jacket passages can easily occur due to a build-up of solids, grease, corrosion and other matter. When this buildup and clogging occur, serious motor damage may result due to overheating and premature insulation failure. Periodic inspection and cleaning are required to prevent these problems. C- External water cooled jacketed motor design When a reliable external source of clean, cool water is available, this type of system has proven to be an effective means of motor cooling. In most cases however, a suitable external water supply is not available or the cost of the clean water is prohibitive. Thus, this type of system has very limited applicability for most customers. D- Closed loop cooled (self-contained cooling system) motor design The closed-loop cooled jacketed motor design offers practical solutions to problems found with other designs. Initial cost is comparable to that of by-pass cooled or external cooled jacketed motor. The selfcontained cooling system eliminates the need for an external water supply. The clear, environmentally safe cooling fluid eliminates clogging, associated maintenance and premature failure commonly associated with pumpage-cooled motors and makes this system the most cost effective when considering overall operating costs. PAGE E006

2- Prevention of surface "vortexing" and associated problems Inadequate submergence can result in pre-rotation of the water in the wet-well, resulting in the formation of strong free-surface air core vortices and the entrance of air into the pump suction inlet. This phenomenon is commonly called "vortexing". "Vortexing" can cause unstable pump operation, vibration, pulsation and severe mechanical damage. The U.S. based Hydraulic Institute has produced the following guidelines for recommended minimum submergence of the pump suction inlet to reduce the probability that strong free-surface air core vortices will occur: S = Minimum submergence to prevent vortexing, in inches D = Pump suction inlet diameter (available from the pump manufacturer), in inches Q = Pump design flow rate, in USGPM S = D + [( 0.574 x Q) / D 1.5 )] Source: American National Standard for Pump Intake Design, Hydraulic Institute, ANSI/HI 9.8-1998, Section 9.8.7 In most cases, the recommended submergence for prevention of free-surface air vortices is more than adequate to prevent motor overheating. The following illustration provides a typical example: Typical 4" Submersible Non-Clog Pump with Guiderail Installation Rated Capacity: 400 USGPM Suction Inlet Diameter: 4" A = 32.70" = Recommended submergence per ANSI/HI standards for prevention of "vortexing" B = 33.25" = Distance from sump floor to top of motor stator housing PAGE E007

SECTION 9000 Solids-Handling Submersible Wastewater Pumps Minimum Submergence Considerations A common question: "What if I operate my pump at a very low level for sump cleanout purposes? Answer: It is normally acceptable to pump the wet-well completely down for purposes of cleaning, inspection or maintenance. This is a common practice and should not result in any damage to the unit. Sustained operation at extremely low levels should be avoided to prevent premature pump seal damage from "vortexing". Conclusions Pump system designers and end-users should consider both motor overheating and prevention of "vortexing" (inadequate suction conditions) when designing systems and specifying non-clog submersible pumps, regardless of the preferred pump manufacturer(s). Proper consideration of both items will help the customer determine suitable sump pit dimensions and level control elevations. For wet-pit installations, it is recommended that the low water level elevation be specified to meet or exceed the minimum submergence to prevent vortexing. In many cases it will be found that the minimum recommended submergence to prevent vortexing will be equal to, or greater than, the minimum submergence required to prevent overheating. This is particularly true if it has been confirmed that the submersible motor has been rated in strict conformance with NEMA standards as is recommended by the Submersible Wastewater Pump Association (SWPA). Thus, once proper anti-vortexing submergence is established, the concern about motor overheating will frequently be eliminated. For applications that require continuous non-submerged operation, such as dry-pit submersible installations, it is recommended that the design engineer specify the motor type best suited for the intended service. For sewage or similar water-based mixtures containing solids, grease or fat, the closedloop-cooled motor design is the preferred choice whenever the horsepower size required exceeds the practical limit for de-rating of conventional submersible motors. Since all applications have specific requirements, the pump manufacturer should be consulted for verification of the proper application of their products and for recommendations of specific equipment for the intended service. PAGE E008

Start-Up Instructions Thank you for your purchasing Yeomans submersible pumps! The pump Warranty requires that the pump be properly installed and that start-up be performed by qualified personnel. Completion of the Start-Up & Warranty Registration Report is required to register the pump start-up with the factory and to support any warranty claims. Copies of electrical schematics (wiring diagrams) for the pump control system may also be required. 1- Review the Installation, Operation & Maintenance instructions supplied with the pump(s). 2- Review the electrical wiring diagrams and related instructions supplied by the manufacturer of the control system. 3- For general start-up procedures and guidelines, please refer to the latest edition of the Start-up & Field Check-Out Procedures Manual published by SWPA (Submersible Wastewater Pump Association). To order copies of this document please contact: Submersible Wastewater Pump Association 1866 Sheridan Road, Suite 201 Highland Park IL 60035-2545 PH: 847-681-1868 FX: 847-681-1869 www.swpa.org 4- Complete the Start-Up & Warranty Registration Report and mail to: Yeomans Pump P.O. Box 6620 Aurora, IL 60598-0620 Attn: Sales Department Administrator The following additional publications may be useful for reference purposes: - Submersible Sewage Pumping Systems (SWPA) Handbook (available from Submersible Wastewater Pump Association) - Submersible Motor Megger Testing (technical paper) (available from Yeomans Pump) PAGE E011

Start-Up & Warranty Registration Report Owner s Name: Address: Location of Installation: Person in Charge: Phone #: Fax #: Purchased From: Series: Model: S/N: Voltage: Phase: Hertz: HP: RPM: Rotation (viewed from bottom): Clockwise Counterclockwise Does impeller turn freely by hand: Yes No Condition of Equipment: Good Fair Poor Condition of Cable Jacket: Good Fair Poor Resistance of Cable and Pump Motor (measured at pump control panel) Red-Black Ohms; Red-White Ohms; White-Black Ohms Resistance of Ground Circuit Between Control Panel and Outside of Pump: Ohms Motor Thermal Sensors connected and circuit closed: Yes No MEG Ohm Check of Insulation: Winding Temperature: ºF ºC Red to Ground Ohms; White to Ground Ohms; Black to Ground Ohms Condition of Equipment at Start-Up: Dry Wet Muddy Was Equipment Stored: Yes No If YES, length of Storage: Describe Station Layout: Liquid Being Pumped: Debris in Bottom of Station? Yes No Was Debris Removed in Your Presence? Yes No Are Guide Rails Exactly Vertical (plumb)? Yes No Is Base Elbow Installed Level? Yes No Liquid Level Controls Model: Is Control Installed Away from Turbulence? Yes No Operation Check: Tip lowest float (stop float), all pumps should remain off. Tip second float (and stop float), one pump comes on. Tip third float (and stop float), both pumps on (alarm on simplex). Tip fourth float (and stop float), high level alarm on (omit on simplex). If not our level controls, describe type of controls: Does liquid level ever drop below volute top? Yes No (Continued on reverse side) PAGE E013

(Continued from reverse side) Control Panel Mfr: Number of Pumps Operated by Control Panel S/N: NOTE: At no time should hole be made in top of control panel, unless proper sealing devices are utilized. Short Circuit Protection: Type: Number and Size of Short Circuit Device(s): Amp Rating: Overload Type: Size: Amp Rating: Do Protective Devices Comply With Pump Motor Amp Rating? Yes No Are All Connections Tight? Yes No Is the Interior of the Panel Dry? Yes No (If No, correct the moisture problem.) Electrical Readings: Single Phase: Voltage Supply at Panel Line Connection, Pump Off, LI, L2: Voltage Supply at Panel Line Connection, Pump On, LI, L2: Amperage: Load Connection, Pump On, LI L2 Three Phase: Voltage Supply at Panel Line Connection, Pump Off, LI-L2 L2-L3 L3-LI Voltage Supply at Panel Line Connection, Pump On, LI-L2 L2-L3 L3-LI Amperage, Load Connection, Pump On, LI L2 L3 Final Check: Is Pump Seated on Discharge Properly? Yes No Was Pump Checked for Leaks? Yes No Do Check Valves Operate Properly? Yes No Flow: Does Station Appear to Operate at Proper Rate? Yes No Noise Level: Acceptable Unacceptable Comments: Describe any equipment difficulties during start-up: Manuals: Has Operator Received Pump Instruction and Operations Manual? Yes No Has Operator Received Electrical Control Panel Diagram? Yes No Has Operator Been Briefed On Warranty? Yes No Name/Address of Local Representative / Distributor: I Certify This Report To Be Accurate. Start-Up Person: (Print Name) (Signature) Employed By: Date: Date and Time of Start-Up: Present at Start-Up: ( )Engineer's Name: ( )Operator's Name: ( )Contractor's Name: ( )Others: Please mail the completed form to: Yeomans Pump, P.O. Box 6620, Aurora, IL 60598-0620, Attn: Sales Administrator or FAX to: 630-236-5511 PAGE E014