Understanding Hatchery Ventilation

Similar documents
Hatchery Management Columns. cobb-vantress.com. hatchery

Effective Management Practices to Reduce the Incidence of Ascites in Broilers

Hatchery Tips from Jamesway s Technical Team. Essential Hatchery Tools by Phillip Perry

Humidity in incubation

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

Kansas State University Fume Hood Operation

QUALITY ASSURANCE HATCHERY

Paw Q Story 10/9/ Steps to Drier Houses & Better Paw Quality. Step 1 Manage Moisture

Ventam 85 Installation & Commissioning Instructions

CONCENTRATION CARBON DIOXIDE

Active Fire Prevention by Oxygen Reduction Systems

Lung Volumes and Capacities

IC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring

Medical Instruments in the Developing World

July Safety Topic: Grain Bin Safety & Heat Exhaustion

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

SECTION 6 SECTION 6. Positioning POSITIONING

How to... The only equipment required for measuring eggshell temperature is a medical infrared ear thermometer. It is recommended to use a Braun

Selecting the right pressure sensor for your application

Minimum Ventilation. Bernard Green Ventilation Technical Service Manager - Asia

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Applied Fluid Mechanics

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Comparing Respiratory Systems

In Vessel Composter Installation & Commissioning Manual

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

HVAC Considerations for Gaseous Decontamination of Laboratory Spaces using Hydrogen Peroxide Vapor

BP OIL -- TOLEDO REFINERY

/ /

PDMS Report 2012, NZG Consultation Process National Membership Statistics, Casual Golf Membership Research.

Chicken Farmers of Canada ANIMAL CARE PROGRAM UPDATE

Home Oxygen Therapy Patient Handbook

Anatomy and Physiology Part 11: Of Blood and Breath by: Les Sellnow

! Time required for inertisation output to interact with and extinguish a fire.

Recommended Fish Handling Guidelines for Bass Tournaments in Alabama Waters

Animal Systems: The Respiratory System

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Trout Care Egg preparation & placement

TACTICAL VENTILATION Graeme Bowser, Tyne & Wear Fire Brigade, U.K.

GUIDELINES ON KILLING CHICKENS

HAP e-help. Obtaining Consistent Results Using HAP and the ASHRAE 62MZ Ventilation Rate Procedure Spreadsheet. Introduction

Oxygen Concentrator Instruction

3.3.2 Gas Exchange SPECIFICATION

Product Recognition Program

BMO Capital Markets 2013 Farm to Market Conference New York, New York. May 14, 2013

2010 NFHS Football Rules Changes

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

Best Practice in the Breeder House

GEN-1e CO2 Generator OVERVIEW INSTALLATION PROPANE GENERATORS ONLY NATURAL GAS GENERATORS ONLY

Goldman Sachs Eighteenth Annual Agribusiness Conference New York, New York. March 12, 2014

BMO Capital Markets New York Road Show New York, New York. December 5, 2013

The last of her species Further development at the Abidjan Zoo

PROBLEM SET 9. SOLUTIONS April 23, 2004

Respiratory Protection Self-Inspection Checklist

Important for you: Please fill in and send back your GUARANTEE CARD straight away!!

DFT Valves. Selecting Control Valves

fact file use of UV in swimming pools The use of UV for destruction of combined chlorine Ing A Beyer, Ing H Worner and BaE R van Lierop

Use of Instrument at Different Altitudes

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

HVAC Air Duct Leakage. Tech University 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

Sizing Enclosures for SCR Power Controllers

Sidoti & Company, LLC West Coast Road Show. San Francisco, California

Respiratory Protection Self Inspection Checklist

UNDERSTANDING A DIVE COMPUTER. by S. Angelini, Ph.D. Mares S.p.A.

Mechanics of compound bow stabilisation

ACTU GUIDELINES FOR WORKING IN SEASONAL HEAT

Respiratory Physiology Gaseous Exchange

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

Ball Beating Lubrication in Refrigetation Compressors

API Canada. Table of Contents

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

Oxygen Dialflow Meter. Instructions for Use

25/4/2016. Physiology #01 Respiratory system Nayef Garaibeh Rawan Alwaten

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Corporate Overview and Product Summary

Simplicity in VRU by using a Beam Gas Compressor

Electron Microscopy Centre

By: Aseel Jamil Al-twaijer. Lec : physical principles of gas exchange

A Referee s Guide to Positioning

Disposal: Science and Theory

Self-Rescue Equipment and Skill Development for Mine Escape

Collin County Community College. Lung Physiology

PSI Chemistry: Gases Multiple Choice Review

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

COATINGS SPRAY GUIDE Urethane 520

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

Respiratory Lecture Test Questions Set 1

Post-Brooding Management

Fan and air movement essentials

FV Flash Vessel Installation and Maintenance Instructions

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

bespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program


2803/01 Transport. January Mark Scheme

Transcription:

Understanding Hatchery Ventilation By Steve Tweed: Hatchery Specialist, Cobb World Technical Support Team. The importance of good ventilation is taken for granted on the farm but it doesn t always attract the same attention in the hatchery. Yet it is here where the foundations for the good broiler performance are laid. Getting the basics right for hatchery ventilation will help achieve a timely hatch, prevent bacterial contamination, ensure high chick quality, help to avoid ascites and contribute to healthy overall returns. It is important to understand why the correct ventilation is so vital. An oxygen level of 19.6% by volume is integral to successful embryonic development, so providing an adequate air supply to the eggs while they are inside the machines is a top priority. While oxygen enters the egg through its porous shell, carbon dioxide escapes in the same manner. A lack of oxygen adversely affects the hatch. As the developing embryo creates heat, it needs additional oxygen and must exhaust carbon dioxide. If the embryo is unable to dissipate this heat satisfactorily, it will develop too quickly, resulting not only in early hatch but also in dehydration and a high likelihood of mortality on the farm. Scattered hatching times reduce hatchery production. With incorrect ventilation, the embryo experiences stress from the cold and there is impaired growth. There is slow development of the circulatory system and heart as well as reduced efficiency of the yolk When there is a lack of oxygen, ascites can occur in today s high-yielding birds at an early age due to decreased capillary flow. Clinical signs of ascites include an enlarged heart and muscle congestion. Fluid builds up in the bird s abdomen, and the heart grows in size from overwork. Regulating air volumes in the hatchery is the first step towards implementing a good ascites prevention program. Pressure controls are excellent tools for attaining a positive pressure on the fresh air intake side of the machines and a neutral pressure on the exhaust sides, thereby preventing the development

of micro-environments within the machines and the fresh air supply itself. This careful balance can deter bacterial contamination and ensure better overall chicken performance following hatch. Every hatchery needs to pay careful attention to field performance. After hatching, it is crucial to move the chicks as quickly as possible into the brooding area and to give them water. Each and every chick needs to be robust and healthy on arrival at the farm. It is the earlier access to an adequate oxygen supply in the hatchery that is paramount for both the development of strong embryos and an on-time hatching process, giving the chicks the best opportunity to thrive. How to achieve effective ventilation The good news is that hatchery ventilation is not complicated as long as the system in place is properly designed, installed, monitored and controlled. For best effectiveness, the system must address the following: Air volumes to meet oxygen demand, even in high altitudes Pressure control throughout the hatchery Humidity control for good air quality Temperature requirements The first steps in establishing a successful ventilation program is an understanding, measuring and monitoring pressure inside the fresh air area, also referred to as a room or plenum. The best fresh air supply systems react to the needs of the hatchery environment from one moment to the next. Pressure controls regulate air movement and manage air volume supply. Positive pressure in the room is an indicator that the available air supply surpasses that which the room demands. A neutral fresh air area means that the air supply and air demand are equal, with no air to spare should demand increases. On the other hand, a negative air supply signifies that the area s air needs exceed the available supply. Pressure measurement to any area besides atmosphere requires a different approach when setting the controls. When the pressure is measured from the room/plenum to atmosphere, you only have to set the controls to what you want. If the pressure for the exhaust plenum is measured to the room and the room is set at +.02, then the plenum control must be set to -.02 to have a neutral pressure in the plenum. When the pressure is all measured to atmosphere and the room is set at +.02 and you want the exhaust plenum to be 000, then you can set it at 000. Consider two 2

separate examples in which the objectives are identical but the references for measurement differ slightly: Measuring exhaust plenum pressure to the fresh air supply pressure Objectives: Neutral exhaust plenum pressure =.000 Fresh air supply pressure= +.015 Required Settings: Exhaust plenum pressure = -.015 Fresh air supply pressure= +.015 Measuring exhaust plenum pressure AND fresh air supply to atmosphere Objectives: Neutral exhaust plenum pressure =.000 Fresh air supply pressure= +.015 Required Settings: Exhaust plenum pressure =.000 Fresh air supply pressure= +.015 As these examples demonstrate, regulating exhaust pressure is a major concern in any ventilation system. A variable speed fan and a pressure equalization device are required for controlling exhaust from designated areas. If through correct administration of pressure controls both the exhausts and fresh air supply react to machine demand, then hatchery management can easily set and monitor effective profile settings rather than make continual manual adjustments to the machines. As mentioned earlier, an oxygen level of 19.6% by volume is the target, and air volume is the only acceptable source of oxygen for a hatchery. Therefore, a hatchery must not only provide adequate air volume to the eggs inside the machines but also stay up-to-date on the air volume needs within different areas, including the incubators, hatchers and chick handling and holding areas. The following factors affect air volume requirements: Total number of eggs in the incubator or hatcher rooms Room volume Desired room pressure Type of ventilation system in use While careful pressure control in a hatchery maintains advantageous bio-security of air movement by pushing air from clean toward dirty areas, it also ensures that air volume is indeed available when machine demand increases. To create good air distribution within the machines, the table below shows both recommended pressure scales and air volume requirements for standard divisions within a hatchery. 3

Recommended Pressure Scales and Air Volume Requirements by Hatchery Area Room/Plenum Air Exchange Pressures Egg Holding 2.00 CFMS per 1000 eggs.000 -.005 + Incubator 8-12 CFMS per 1000 eggs.015 -.020 + Hatcher 17-25 CFMS per 1000 eggs.005 -.01 + Hallways 5 per minute air exchange.000 Dirty Pull 40-60 CFMS per 1000 chicks.010 -.020 Clean Holding 1 per minute per room volume.020 -.025 + Chick Holding 40-60 CFMS per 1000 chicks.000 -.005 All wash areas 1 minute air exchange.020 -.025 Exhaust Equal to machine demand.000 Even Pressure conversion (0.01 inches H20 = 2.5 Pascal s, 0.01 mbar, 0.1016 mmh20) Air Exchange (1cfm = 1.69chm) Satisfying the minimum oxygen level requirement for a hatchery can be more difficult when special circumstances, such as high altitude, apply. The answer is to increase the positive pressure in the fresh air supply area to funnel more air volume through the machines. Each type of machine has a maximum pressure level that also allows for an appropriate damper opening to accept an adequate air volume. The chart below compares altitude and partial pressure of available oxygen in the air. Note that it is virtually impossible to obtain the 19.6% usable oxygen in the air at locations above 762 metres (2,500 feet). Relationship between Altitude and Partial Pressure of Available Oxygen in Air Altitude Reduction Available Sea Level 0% 20.5-21.0% 1,500 feet 457 meters 3.5% 19.8-20.3% 2,000 feet 610 meters 5.1% 19.5-19.9% 2,500 feet 762 meters 8.1% 18.9-19.3% 4,000 feet 1,219 meters 11.2% 18.2-18.6% 6,000 feet 1,829 meters 16.6% 17.1-17.5% 4

No ventilation program is complete without providing eggs with a defence against moisture loss. During incubation, an egg loses water vapour through pores in the shell. Humidity and temperature are key factors in every egg s battle to stay hydrated. When a hatchery applies water while the humidifiers are running, the temperature drops for as long as the humidifiers are in operation. In addition, running heaters will fight to maintain the pre-set temperature. Consequently, the humidifiers and heaters race against one another and ultimately increase the facility s energy expenses unnecessarily. The best method for controlling relative humidity is through steam humidification, which uses the hatchery s air supply. By introducing steam in the room or fresh air supply duct, humidification occurs without a costly drop in temperature. Fresh air, when tempered by humidity and temperature, increases machine efficiency, fosters an ideal environment for embryonic development and meets air volume demand. A delicate equilibrium among temperature, humidity and fresh air supply is necessary for protecting incubating eggs. The table below is a guide for temperature and humidity requirements for the various hatchery areas. Temperature and Humidity Requirements by Hatchery Area Room/Plenum Temperature Range Relative Humidity Egg Holding Cooler 65-68 F (18-20 C) 65% Incubator Room 75-80 F (24-27 C) 55% Hatcher Room 75-80 F (24-27 C) 55% Chick Holding 75-78 F (24-26 C) 70% Guidelines for Smooth Ventilation System Operation 1. All of the internal as well as external doors must remain closed unless someone is passing through them. 2. The fresh air supply, air volume demand and exhaust must be balanced at all times. 3. A variable volume air supply (HVAC) and exhaust/recirculation volume must be available to assist with maintaining a dependable, consistent hatchery environment. 5

4. When natural chimney exhausts are used, the effects of the chimneys will vary drastically as the outdoor temperature changes. Mechanically controlled exhausts are a better alternative, so seasonal or temperature-related swings do not affect production. 5. Any variable speed fan that controls pressure in a room or plenum must have a good back draft shutter. In summary, good chick quality is the prerequisite for good broiler performance and attractive profit margins. Chick quality is directly related to good hatchery management. This depends on hatchery-wide pressure control, adequate air volumes for oxygen delivery and well-maintained humidity and temperature levels. In a modern-day twist to the old conundrum What came first? the answer is neither the chicken nor the egg. quite simply it s the correct ventilation. Steve Tweed Residing in the United Kingdom: Company: Cobb Vantress. Member of the World Technical Support Team Hatcheries: (South America, Africa, Middle East and Europe) E-mail: steve.tweed@cobb-europe.com 6