Adult All Integrated Mini Bypass System

Similar documents
INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

INSPIRE TM C The integrated closed system oxygenator for gentle perfusion

A complete family of Pediatric Perfusion Systems

INSPIRE TM Inspired choice

Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

S5 TM. Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

INSPIRE Oxygenator Family

INSPIRE TM8 PH.I.S.I.O.

Clinical Engineering. Equipment (Heart-lung machines)

Considerations in Circuit Miniaturization

INSPIRE 6 PH.I.S.I.O.

Optimized Perfusion Management and Patient Outcome

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

CAPIOX FX Advance. Oxygenator with Integrated Arterial Filter and Hardshell Reservoir

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

Patients come in a range of sizes. Now your oxygenator does, too.

Alfred ECMO Circuit Priming and Storage Guide

Blood Parameter Monitoring System 550

ila ACTIVVE SYSTEM PLATFORM

Prescriptive Oxygenation

PERFUSION SYSTEMS MECC SMART SMART SUCTION SYSTEM

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

WARNING: All medications should be closely monitored to detect any alterations in the effective concentration due to the ultrafiltration process.

CAPIOX SX Family of Oxygenators

InFlow Modular perfusion bioreactor

CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

Equipment and monitoring for cardiopulmonary bypass

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

(12) United States Patent (10) Patent No.: US 6,524,267 B1

DIAGNOSTIC CARDIOLOGY

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

Perfusion Safety Review in Japan

An In Vitro Analysis of a One-Way Arterial Check Valve

Point-of-Care Testing: A Cardiovascular Perfusionist s Perspective

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

An In-Vitro Study Comparing the GME Handling of Two Contemporary Oxygenators

MyoSure Setup Simplified

ENT 318/3 Artificial Organ. Artificial Lung. Lecturer Ahmad Nasrul bin Norali

Recommendations for Standards. Monitoring. Cardiopulmonary Bypass

Citation for published version (APA): Somer, F. M. J. J. D. (2003). Strategies for optimisation of paediatric cardiopulmonary bypass s.n.

Indications for Use: Caution: Note:

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

The next generation of Blood and Fluid Warming

Diacan and Diacan S. The safe and gentle vascular access for dialysis

INTERNATIONAL MARKETING. 61, avenue Tony Garnier Lyon France Tel.: 33 (0) Fax: 33 (0)

The next generation of Blood and Fluid Warming

AQUADEX FLEXFLOW SYSTEM QUICK REFERENCE GUIDE

Emboli Production in Hardshell Venous Reservoirs at Low Reservoir Levels Devin Eilers, BS, Willie Glaze, BS, & David Holt, MA, CCT Clinical Perfusion

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

Supporting you in saving lives!

Contacts. Quick Start Guide

Bloodlines, Tubing Systems, Accessories

Recommendations. For Standards of. Monitoring and Safety during. Cardiopulmonary Bypass

Recommendations for Standards of Monitoring and Alarms During Cardiopulmonary Bypass

Development of a Practical Membrane Lung System

CARDIOHELP System designed to save lives

Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius

Limitations Using the Vacuum-Assist Venous Drainage Technique During Cardiopulmonary Bypass Procedures

AQUARIUS Continuous Renal Replacement Therapy Competency

WORKHOLDING APPLICATION BOOKLET

Thoracic Key Fastest Thoracic Insight Engine

VACCUPERM Vacuum chlorine gas dosing systems

The centerpiece of a comprehensive anaesthesia workstation

FAST EVAPORATION AT NORMAL PRESSURE

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

Kinetics Fluid Systems - Process Flow Products. 18 February

ISE Subsea Tools and Toolsleds

Installation and commissioning instructions 255 series and 256 series

AQUARIUS Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation (RCA) Competency

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

healthy volunteers were included in the study.

Preclinical Evaluation of a New Hollow Fiber Silicone Membrane Oxygenator for Pediatric Cardiopulmonary Bypass: Ex-vivo Study

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

Intelligent Ventilation solution from ICU to MRI

Huber needle EZ Huber JetCan. Quality and Experience

Airox Supportair Ventilator

An intuitive and innovative answer to your anaesthesia challenges

Tube Puller CP/CPS series. Pullers designed with cutting edge technology

Drilling Efficiency Utilizing Coriolis Flow Technology

Tradition & Technology

HelixAR. Electrosurgical Generator with Argon Beam Coagulation

A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM

INTERVENTIONAL CARDIOLOGY

CATALOGUE. Adult and Infant Respiratory Care Catalogue

Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters

Leadership in Fluid Management

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

Compact medical oxygen generator for : J Anaesthesia machines / OTs J Recovery ventilators / ICUs J Oxygenotherapy J Cylinder filling systems

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

DONOR TM Pre-Evacuated Post-Operative Autologous Blood Reinfusion System

Haemodialysis. Bloodlines, Tubing Systems, Accessories Product Range. Product name / Headline Subline

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

fabian Therapy evolution Our 2-in-1 device

MEDAP-MOBILE GAS SUPPLY

icon i150 / i350 Installation / Operation Manual

Transcription:

Adult All Integrated Mini Bypass System

Clinical Flexibility without Sacrificing Patient Safety Imagine a new, innovative, completely closed system that includes a venous bubble trap, centrifugal pump, heat exchanger/oxygenator and arterial filter, all integrated into one single device. Synergy is based on a compact, dedicated HLM platform complete with all standard safety features and includes the use of the BRAT ATS system for suction blood sequestration. S5 minibypass HLM configuration SCP + provides a simple, ergonomic user interface for managing SYNERGY Mast mounted S5 double head roller pumps ideal for shortening APC and cardioplegia lines APC - maximizing entrained air management 3 position S5 optimal for all mini bypass cases ERC - maximun patient safety, unique to Sorin Group Extension arm permits positioning of SYNERGY as close as possible to patient

SCPC+SCP Centrifugal Pump System The Synergy was developed around the Revolution Centrifugal Pump, which offers many key safety features including: Excellent air handling capability Low prime volume Low heat generation Low index of hemolysis Estremely efficient design Low blood transit time No areas of stagnating flow BRAT2 Autologous Blood Recovery System Performance, Speed, Versatility, and Quality Processing Dedicated processing keys to start processing quickly and easily Built-in reservoir holder eliminates the need for additional holder Flat, clear lid with safety lock provides visibility of the bowl and a flat writing surface Smaller profile fits well in any size operating room Storage area for additional supplies Three position wheel locking mechanism maximizes mobility Easy to load disposables snap correctly into place without hassle Automatic re-pack feature removes excessive plasma free hemoglobin and ensures proper bowl filling Patented Baylor Bowl provides a high hematocrit and fast processing

Purge line used with roller pump + APC Bubble sensor for APC ERC Bubble sensor for ERC Electric Remote Clamp (ERC) Offers the same level of safety as a fluid level sensor of a conventional venous reservoir Can be manually operated from the SCP Centrifugal Pump Control Console Closes automatically when air is detected coming from venous bubble trap Prevents retrograde flow and closes when arterial flow goes to LPM Air Purge Control (APC) Dedicated module for the S5 control panel Used in conjunction with a bubble sensor on the venous inlet line as shown above to manage venous air Uses a dedicated roller pump on the SIII and S5 Purged volume is sent to a storage reservoir or cardiotomy in the circuit to prevent loss of autologous blood

Improved Patient Outcomes Optimised Bypass - Combining the clinical benefits of phosphorylcholine and suction blood separation with low prime, significant reduction of the blood-air interface, and reduced foreign surface area in contact with the patient circulating volume. The concept of optimized or Mini Bypass combines all the known benefits into one total systemic approach to improve patient outcomes on pump. Several clinical studies have demonstrated the efficacy of the mini bypass concept in terms of reduced Hemodilution and subsequent reduction in blood products use. Blood Hemoglobin, On Pump 13 12 11 1 9 8 7 6 5 Pre bypass After cardioplegia Crossclamp off cecc Frequency of transfusions Units of blood transfused Units FFP cecc p,27 ±,45,43 ±,5.5,53 ±,9 1,3 ± 1,93 <.5 3 <.1 Cumulative Post Operative Bleeding (during ICU stay) 1, 8, 6, 4, 2,, cecc Dr M Perthel, Bad Bevensen Blood Product Usage in Routine CABG Compared to Conventional Bypass Presented at the Canadian Cardiothoracic Meeting, Montreal 25 Creatine Kinase 6 * p<.5 5 * p<.5 Further studies have demonstrated the clinical benefits of higher on pump hematocrit in terms of quality of perfusion, as well as the benefits in terms of reduced platelet activation and systemic inflammatory response. 4 3 (U/L) 2 1 ICU ICU 2h ICU 8H ICU POD 29 261 299 45 Control 211 256 453 53 Dr MJM Hybregts et al, Free University Hospital Amsterdam, The Netherlands Quality of Perfusion in Mini Bypass as Compared to Conventional Bypass Presented at FECECT, Orosei, Sardinia June 25 P-Selectin Plasma Level Prothrombin fragment formation 8 7 6 5 4 3 2 1 P=.3 P=.3 t t1 t2 t3 t t1 t2 t3 1,5 1,2,9,6,3 Prothrombin and P-Selectin plasma levels (mean ± SD) at various time points: prior the sternotomy (TO), at the end of CPB (T1), at 6 (T2) and 24 hours (T3) after CPB P<.3 P<.3 Standard CPB Dr A. Farneti and Dr M Glauber, Ospedale S. Pasquinucci, Massa Italy Reduction of coagulative response and monocyte-platelet interaction following the use of minimal extracorporeal circulation system in CABG patients Presented at EACTS 25, Barcelona Spain

SYNERGY: the evolution of CPB, emphasising clinical flexibility and biocompatibility without sacrificing patient safety Key Functional Characteristics, SYNERGY System Prime volume 68 ml Oxygenator Surface Area 2. m 2 SYNERGY Maximum Recommended Rated Flow 8 LPM Pressure Drop, Oxy/Filter Module 3 Oxygen Transfer 5 ΔP (mmhg) 25 2 15 1 5 ml / min 4 3 2 2 3 4 5 6 7 8 1 Testing was performed with bovine blood at standard AAMI conditions and at a barometric pressure of 76 + 1 mm Hg. Mean values are shown for comparison purposes only and may not represent clinical performance., 2, 4, 6, 8, Blood Flow Rate (l/min) CO 2 Transfer 6 Qg/Qb,5/1 Qg/Qb 1/1 Qg/Qb 2/1 Heat Exchange 1. 5.9.8 ml / min 4 3 2 1 Performance Factor.7.6.5.4.3.2.1, 2, 4, 6, 8, Blood Flow Rate (l/min). 1 2 3 4 5 6 7 8 Blood Flow Rate (LPM)

Venous Optiflow Cannulaa Specifically designed for active venous drainage The special-design injection-molded 13 cm tip with multiple holes grants an optimal venous drainage independent of the position of the heart Wire reinforced PVC tubing with depth markings and introducer Available size: 29 French Arterial Cannula 3 dimensional dispersion of the blood flow big opening outlet area Optiflow Characteristics avoids jet stream homogenous flow profile with low velocities reducing dislodgement of plaques and so the risk of atheroembolic complications with low pressure gradients and no increasing of the haemolysis smooth tip for easy insertion The OPTIFLOW is another dedicated product in our range, to improve the biocompatibility of the whole ECC system, our multifactorial approach. CSC-14 The CSC -14 Cardioplegia Heat Exchanger. With a priming volume of 3 ml, superior heat exchange characteristics and excellent blood flow path visibility, the CSC-14 provides the clinician with a means of managing myocardial protection in a safe and flexible way.

ORDER GUIDE SYNERGY SYSTEM DESCRIPTION CODE Standard Closed System 74622 Standard Open System (with Cardiotomy reservoir) 74632 Closed to open system conversion kit 84392 Synergy Holder 5131 Mini bypass Reservoir Bag Holder (for 74622) 5124 D716 Holder for D764 Cardiotomy reservoir (for 74632) 573 D712 Holder for Sampling Manifold 569 For more information regarding the S5 mini HLM, the Brat2 System, and order information, please contact your local representative. Please contact Sorin Group North America for the standard SYNERGY configuration in the US market. Please read all product instructions for use prior to clinical use of the system. according to MDD 93/42/ECC emended by Directive 27/47/EC manufactured by: Sorin Group Italia S.r.l. Via Statale 12 Nord, 86 4137 Mirandola Modena Italy Tel +39 535 29811 Fax +39 535 24312 www.sorin.com info.sorin-cp@sorin.com 933-42 9/9