Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Similar documents
Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Operating Instructions

Operating Instructions

Operating Instructions

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Arran LED Floodlight Luminaire

Further technical information is available on

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Type BBS-03, BBS-05, BBS-06, BBS-25

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

MODELS (2 foot Version) (4 foot Version)

Manual Power relay SR853

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

EX-RECESSED CEILING LIGHT FITTINGS

(Certification N:o VTT 08 ATEX 066 or IECEx VTT )

Actuating elements for ComEx

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Junction Boxes Series 8118

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502

Instruction Manual Contact Pressure Vacuum Gauge

Magnetic level switch type MR783 Instruction Manual

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Norrsken Family Booklet

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

INSTRUCTION MANUAL Pressure Relief Device LPT

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

IECEx Certificate of Conformity

LED 14W POLO BULKHEAD WITH MICROWAVE SENSOR

Less power great performances

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Digital Melting Point Apparatus

Pressure switch KP-E. Data sheet

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Pressure Measurement Single-range transmitters for general applications

Declaration of Conformity as per Directive 97/23/EC

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Operating Instructions Temperature Measuring System MF420-5T-100

OPTIBAR P 1010 C Technical Datasheet

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

Instructions for Safe Use

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

A17W49_MASEM_F_EN MANUAL

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

Pressure Measurement Single-range transmitters for general applications

4/2 way Pneumatic Solenoid Valve

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

VG5 Supplementary instructions

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Conductor Bushings Series 8174

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

ATEX heated hoses of series WEX7

Declaration of Conformity as per Directive 97/23/EC

Electro-Pneumatic Converter YT-940 SERIES

FPD20 Series. Gear wheel flow sensor

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures.

Translation of the original Operating Instructions for HKS rubber compensators

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Monitoring device NTS 30

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

M-5071/1111. Electronic Pressure Switch PSW14 series

Siphon vessel / Priming aid

High-performance submersible pressure transmitter For level measurement Model LH-20

Position switches FP series

Pre-filter for Brushless Blower Instruction Manual

Sample Concentrator SBH CONC/1 Instructions for use

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

Pressure controls for hydro carbons, zone II applications, Type KPE

ERS200. Safety Command Devices. Original Phone: operating instructions - Fax: Web:

DWR6-205, DWR16-205, DWR6-206 Safety Pressure Limiters

RTD temperature probes

OPERATION MANUAL PNEUMATIC VALVES

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

Diaphragm Pressure Keeping Valve

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Pressure Relief Valve DHV 718

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

USER MANUAL. JET TST and JET TST S.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Transcription:

Floodlight LED Operating instructions Additional languages www.r-stahl.com

Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity with standards and regulations...3 2 Explanation of the symbols...4 2.1 Symbols in these operating instructions...4 2.2 Warning notes...4 2.3 Symbols on the device...5 3 Safety notes...5 3.1 Operating instructions storage...5 3.2 Safe use...5 3.3 Intended Use...5 3.4 Modifications and alterations...5 4 Function and device design...6 4.1 Function...6 4.2 Device design...6 5 Technical data...7 6 Transport and storage...10 7 Mounting and installation...10 7.1 Dimensions / fastening dimensions...10 7.2 Mounting / dismounting, operating position...12 7.3 Installation...12 8 Commissioning...16 9 Maintenance, Overhaul, Repair...17 9.1 Maintenance...17 9.2 Repair...19 9.3 Returning the device...19 10 Disposal...20 11 Accessories and Spare parts...20 2 Floodlight LED

1 General Information 1.1 Manufacturer R. Stahl Schaltgeräte GmbH Am Bahnhof 30 74638 Waldenburg Germany Phone: Fax: Internet: E-mail: +49 7942 943-0 +49 7942 943-4333 www.r-stahl.com info@stahl.de 1.2 Information regarding the operating instructions ID-No.: Publication Code: The original instructions are the English edition. They are legally binding in all legal affairs. General Information R. STAHL (P) LTD., Plot No. - 5 Malrosapuram Road, Sengundram Indl. Area Singaperumal Koil, Kancheepuram Dist., Tamil Nadu 603 204, INDIA Phone: Fax: Internet: E-mail: +91 44-30 600 600 +91 44-30 600 700 www.rstahl.net sales@rstahl.net 1.3 Conformity with standards and regulations See certificates and EU Declaration of Conformity: www.stahl-ex.com. The device has IECEx approval. See IECEx homepage: http://iecex.iec.ch/ Further national certificates can be downloaded via the following link: https://r-stahl.com/en/global/products/support/downloads/. Floodlight LED 3

Explanation of the symbols 2 Explanation of the symbols 2.1 Symbols in these operating instructions Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere Danger due to energised parts Risk of damage to the eyes caused by optical radiation 2.2 Warning notes Warnings must be observed under all circumstances, in order to minimize the risk due to construction and operation. The warning notes have the following structure: Signalling word:, WARNING, CAUTION, NOTICE Type and source of danger/damage Consequences of danger Taking countermeasures to avoid the danger or damage Danger to persons Non-compliance with the instruction results in severe or fatal injuries to persons. WARNING Danger to persons Non-compliance with the instruction can result in severe or fatal injuries to persons. CAUTION Danger to persons Non-compliance with the instruction can result in light injuries to persons. 4 Floodlight LED

Safety notes 2.3 Symbols on the device 3 Safety notes NOTICE Avoiding material damage Non-compliance with the instruction can result in material damage to the device and / or its environment. Symbol 05594E00 02198E00 Meaning CE marking according to the currently applicable directive. According to marking, device approved for hazardous areas. 3.1 Operating instructions storage Read the operating instructions carefully. Store the operating instructions at the mounting location of the device. Observe applicable documents and operating instructions of the devices to be connected. 3.2 Safe use Read and observe the safety notes in these operating instructions! Observe characteristic values and rated operating conditions on the rating and data plates! Observe additional information plates on the device! Use the device in accordance with its intended and approved purpose only! We cannot be held liable for damage caused by incorrect or unauthorized use or by non-compliance with these operating instructions. Before installation and commissioning, make sure that the device is not damaged! Work on the device (installation, maintenance, overhaul, repair) may only be carried out by appropriately authorized and trained personnel. 3.3 Intended Use The LED floodlight 6525 is equipment for stationary mounting for use in Zones 21, 2, 22 and in the safe area can be used indoors and outdoors for lighting areas, work spaces and objects 3.4 Modifications and alterations Explosion hazard due to modifications and alterations to the device! Non-compliance results in severe or fatal injuries. Do not modify or alter the device. Floodlight LED 5

Function and device design 4 Function and device design 4.1 Function for lighting areas, work spaces and objects 4.2 Device design Explosion hazard due to improper use! Non-compliance results in severe or fatal injuries. Use the device only in accordance with the operating conditions described in these operating instructions. Use the device only for the intended purpose specified in these operating instructions. 13 18668E00 1 - Mounting bracket 8 - Seal 2 - Enclosure cover 9 - Luminaire glass cover 3 - Retaining bracket LED-Driver 10 - Mounting screws 4 - LED-Driver 1 11 - LED-Driver 2 (only for 210 W version) 5 - LEDs 12 - Cable glands 6 - Luminaire enclosure 13 - Connection terminal 7 - Heat sink (only for 210 W version) 6 Floodlight LED

5 Technical data Explosion Protection Global (IECEx) Gas and dust IECEx EPS 15.0032 Ex nr op is IIC T6... T5 Gc Ex tb IIIC T80 C... T95 C Db Europe (ATEX) Gas and dust EPS 15 ATEX 1 991 E II 3 G Ex nr op is IIC T6... T5 Gc E II 2D Ex tb IIIC T80 C... T95 C Db Certifications and certificates Certificates IECEx, ATEX, India (PESO) Technical Data Electrical data Electronic balast Rated voltage Rated current 6525/11..-23..-...-... 6525/11..-44..-...-... AC: 220... 240 V ±10 %; 50... 60 Hz Technical data Power Ambient temperature Max. surface temperature 120 W 210 W ( +60 C T5 / T95 C 6525/1...-23..-...-... 120 W ( +50 C T6 / T80 C 6525/1...-44..-...-... 210 W ( +45 C T6 / T80 C Ambient temperature Power -60... -40 C -40... +60 C 120 W 0.60 A 0.54 A 210 W 1.00 A 0.94 A Inrush current 120 W Version 210 W Version I peak (measured at 50 % I peak ) 62 A; ãt = 330 ms 124 A; ãt = 330 ms max. light fittings per circuit breaker Type B Type C Type B Type C 10 A 4 8 2 4 16 A 8 14 4 7 20 A 11 19 5 9 25 A 20 23 10 11 Power factor > 0.95 THD ( 10 % Floodlight LED 7

Technical data Technical Data Luminous characteristics Luminous flux decrease 6525/11..-2...-...-... 6525/11..-4...-...-... Power consumption [W] 120 210 Colour rendering [CRI] ) 70 ) 70 Colour temperature [K] 5,700 5,700 wide beam Luminous flux [lm] 12,860 21,026 Luminous efficiency [lm/w] 107 100 medium beam Luminous flux [lm] 12,669 20,966 Luminous efficiency [lm/w] 94 99 narrow beam Luminous flux [lm] 12,081 19,979 Luminous efficiency [lm/w] 101 96 Values apply to T a = +25 C. at ambient temperature 115 % 100 % 85 % 70 % 55 % 210 W Version 120 W Version 40 % 25 % 30 C 35 C 40 C 45 C 50 C 55 C 60 C Ambient conditions Operating temperature range -60... +60 C * * Note: Possible to operate the luminaire at -60 C, provided the luminaire is switched on at -40 C. Delay of 10 seconds below -40 C during cold start Storage temperature -40... +75 C 19597E00 8 Floodlight LED

Technical Data Service life Mechanical data Degree of protection Protection class Impact strength (IK code) Material Enclosure IP66 I (with internal PE connection) IK10 (IEC 62262) Ambient temperature T a Colour Colour white, similar to RAL 9010 Seal Foamed silicone in luminaire cover Lamp cover Toughened glass Bracket Sheet steel, single powder-coated or Stainless steel SS316L (1.4404 or V4A) without powder coating Luminaire locking Screw Mounting / Installation Cable entry 1x cable glands Series 8161 1x cable glands Series 8161 with red stopping plug 1x stopping plugs Series 8290 Connection Standard: Spring clamp terminals 0.5... 4 mm 2 solid / stranded Stripping length: 10... 11 mm Optional: Spring clamp terminals 0.5... 6 mm 2 solid / stranded Stripping length: 13... 15 mm Technical data ( +40 C +45 C +50 C +55 C +60 C L 70 B 10 C 10 100,000 h 80,000 h 80,000 h 60,000 h 50,000 h L x B y C z At the end of the service life: - Luminous flux decreases by x percent. - up to "y" percent of all luminaires fall below "x" - up to "z" percent of all luminaires break down completely 6525/...-...-...-.11 Sheet steel, powder-coated 6525/...-...-...-.42 Stainless steel SS316L (1.4404 or V4A), with double powder coating (offshore coating) Loop in/loop out max. 12 A Alternative material: Enclosure: stainless steel SS304 (1.4301 or V2A) single powder-coated stainless steel SS316L (1.4404 or V4A) without powder coating Bracket: stainless steel SS304 (1.4301 or V2A) without powder-coated Floodlight LED 9

Transport and storage 6 Transport and storage Transport and store the device only in the original packaging. Store the device in a dry place (no condensation) and vibration-free. Do not drop the device. 7 Mounting and installation Explosion hazard due to incorrect installation of the device! Non-compliance results in severe or fatal injuries. Carry out installation strictly according to the instructions and national safety and accident prevention regulations to maintain the explosion protection. Select and install the electrical device so that explosion protection is not affected due to external influences, i.e. pressure conditions, chemical, mechanical, thermal and electric impact such as vibration, humidity and corrosion (see IEC/ 60079-14). The device must only be installed by trained qualified personnel who is familiar with the relevant standards. 7.1 Dimensions / fastening dimensions Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 400 [ 15,75] 600 [ 23,62 ] 131,90 [ 5,19] 400 [ 15,75] 89,50 [ 3,52] 600 [ 23,62 ] 89,50 [ 3,52] 17560E00 Floodlight with cooling element (Version 210 W) 17559E00 Floodlight without cooling element (Version 120 W) 10 Floodlight LED

Mounting bracket 18258E00 Mounting and installation Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 363 [1,38] 3 [0,12] 445 [17,52] 405 [15,94] R 20 [R 0,79] 250[9,84] 3 x Ø13 [3 x Ø 0,51] 20 [0,79] Floodlight with ring bolts with cooling element (Version 210 W) 380 [14,96] 60 [2,36] 363 [14,29] 13 x Ø8,50 [13 x Ø 0,33] Ø 8,50 [Ø 0,33] Floodlight with ring bolts without cooling element (Version 120 W) 17561E00 18257EE00 Floodlight LED 11

Mounting and installation 7.2 Mounting / dismounting, operating position Explosion hazard due to inadmissible heating! Non-compliance results in severe or fatal injuries. Avoid external heat sources and/or direct sunlight (risk of change of temperature class or change of maximum permissible surface temperature). Do not exceed the maximum ambient temperature due to external heat sources (premature failure of equipment). CAUTION Risk of damage to the eyes caused by optical radiation! Minor injuries are possible! The minimum distance for the narrow beam version between the luminaire and the viewer's eyes must be 8.23 m. suitable for use indoors and outdoors designed for wall, ceiling, pole mounting with bracket max torque value between bracket and floodlight 10 Nm pendant mounting using ring eyes (M6). 7.3 Installation 7.3.1 Opening and Closing of the Enclosure Risk of electric shock due to improper opening! Non-compliance results in severe or fatal injuries. Open luminaires without switch only in de-energized state (see information plate on the lock)! NOTICE Danger due to electrostatic discharge. Electronic components can be destroyed if touched. Do not touch the LED-PCBs! 12 Floodlight LED

Opening the luminaire (1) loosen the four mounting screws. (2) carefully open the enclosure cover. (3) open the enclosure cover fully. Mounting and installation 18669E00 Closing the luminaire (4) liften the enclosure cover. (5) carefully close the enclosure cover. (6) securely tighten the four screws (torque value 5 Nm). 18670E00 Floodlight LED 13

Mounting and installation 7.3.2 Cable entries WARNING Not approved cable glands and stopping plugs. Explosion protection is impaired! Only use separately certified cable glands and stopping plugs. Cable glands and stopping plugs must be approved for the following types of protection: a) restricted breathing (nr) and dust (IIIC) b) increased safety (e) Recommendation: Use of cable glands and stopping plugs supplied by R. STAHL Schaltgeräte GmbH. see data sheet on our homepage www.stahl-ex.com. Please observe the following, if cable glands and stopping plugs are used, but not provided by R. STAHL Schaltgeräte GmbH: Permissible cable diameter range, torques, temperature range of use IP level of protection, at least IP 65 or according to details on rating plate Operating instructions of the cable glands and stopping plugs additionally, observe the following for cable glands and stopping plugs of the type of protection "increased safety" (e): valid EC type examination certificate and confirmation of the manufacturer for the combination of the cable and screw connection Explosion hazard if breathers are used! Accidents or fatal injury are almost certain to happen! Do not use breathers. 14 Floodlight LED

7.3.3 Electrical connections Electrical connection Observe the maximum clamping possibility of the connecting terminals (see chapter "Technical data"). Note: Clamping must be carried out precisely! Do not clamp any part of the conductor insulation! Do not interchange the conductors! Observe the technical regulations when connecting the conductor! Clamp the conductor firmly. Connection terminals Standard: Spring clamp terminals 0.5 to 4 mm 2 (rigid and flexible) Stripping length: 10... 11 mm 5-pole N L1 L2 L3 N L1 L2 L3 15516E00 Legend L1, L2, L3 = phase (3-pole: L1; 5-pole: L1, L2, L3) N = neutral conductor PE = protective conductor Mounting and installation Optional: Spring clamp terminals 0.5 to 6 mm 2 (rigid and flexible) Stripping length: 13... 15 mm 5-pole 16526E00 Floodlight LED 15

Commissioning 8 Commissioning Explosion hazard due to incorrect installation! Non-compliance results in severe or fatal injuries. Check the device for proper installation before commissioning. Comply with national regulations. Explosion hazard due to incorrect installation! Non-compliance results in severe or fatal injuries. Carry out the restricted breathing test prior to first commissioning. (See chapter "Restricted breathing test") Before commissioning, ensure the following: Check the mounting and installation. Inspect enclosure for damage. If necessary, remove foreign bodies. If necessary, clean the connection chamber. Check if the conductors have been inserted correctly. Check if all screws and nuts have been tightened firmly. Check whether all the cable entries and stopping plugs have been tightened firmly. Check if all conductors have been clamped firmly. Check if the line voltage and the rated operational voltage are consistent. Check if the permissible conductor diameter for the corresponding cable entries have been used. Check if the device is closed according to regulations. Check whether the bracket mounting & cover mounting screws are tightened with proper torque. NOTICE Malfunction or device damage caused by condensation. Non-compliance can result in material damage! operate the luminaire continuously or periodically over extended periods of time. avoid thermal bridges. 16 Floodlight LED

9 Maintenance, Overhaul, Repair 9.1 Maintenance Maintenance, Overhaul, Repair WARNING Risk of electric shock or malfunctioning of the device due to unauthorized work! Non-compliance can result in severe injuries and material damage. Work performed on the device must only be carried out by appropriately authorized and qualified electricians. To be carried out as per 60079-17 and as per 60079-19. Explosion hazard due to hot built-in components! Accidents or fatal injury are almost certain to happen! Only open the enclosure in switched-off state. The device must be allowed to cool down for at least 15 minutes before opening it. NOTICE Danger due to electrostatic discharge. Electronic components can be destroyed if touched. Do not touch the LED-PCBs! Observe the relevant national regulations in the country of use. Determine the type and extent of inspections in compliance with the relevant national regulations. Adapt inspection intervals to the operating conditions. The following tests and measures must be carried out during regular maintenance. Check the permissible ambient temperature the enclosure components for formation of cracks and damage. its intended use if the conductors are clamped properly the cables for ageing and damage Measures If exceeding the permissible ambient temperature or falling below the device must be taken out of operation. Replace the exchangeable enclosure components. If the enclosure components are non-exchangeable, the device must be taken out of operation. If the device is not used according to its intended use, it must be taken out of operation. clamp loose conductors tightly. replace damaged or aged cables. Floodlight LED 17

Maintenance, Overhaul, Repair Check the seals for ageing and damage Measures replace damaged, aged and porous seals and completely change enclosure components with foamed seal. the inside and outside of the luminaire for clean the luminaire. pollution Restricted breathing of enclosure (see chapter "Restricted breathing test"). If the restricted breathing test has failed, take the device out of operation! NOTICE Moisture inside the light fitting can result in damage to electric and electronic components. Remove moisture with a cloth! Determine the source and eliminate the cause! Avoid condensation and thermal bridges! WARNING Restricted breathing is not guaranteed any longer! Explosion protection is impaired! After replacing seals or enclosure components carry out the restricted breathing test acc. to IEC/ 60079-15, para. 23.2.3.2.1.1. 9.1.1 Restricted breathing test The luminaire is equipped with a test device for restricted breathing. Restricted breathing must be checked after installation and during regular maintenance acc. to IEC/ 60079-15. Inspection according to IEC/ 60079-15, para. 23.2.3.2.1.1 Recommendation Check the luminaire by using the handheld testing instrument for restricted breathing from R. Stahl Schaltgeräte GmbH (see data sheet). The test should only be carried out at constant temperature conditions. 18 Floodlight LED

Maintenance, Overhaul, Repair In order to test restricted breathing (pressure test), the luminaire is equipped with a cable entry with red stopping plugs. Remove the red stopping plug. Insert the hose of the test device into the cable entry for testing restricted breathing. Hand-tighten the cable entry. Use the hand pump to create a vacuum of 0.3 kpa (3 mbar). The test has been passed if after 90 seconds a vacuum of at least 0.15 kpa (1.5 mbar) is still present in the luminaire. After inspection: Remove the hose of the test device for testing restricted breathing from the cable entry. Close the luminaire using the red stopping plug. Alternative pressure and time specifications: Alternative 1 Alternative 2 Vacuum at start of test 3.0 kpa (30 mbar) 0.3 kpa (3 mbar) Test duration 14 seconds 14 seconds Vacuum after testing 2.7 kpa (27 mbar) 0.27 kpa (2.7 mbar) If the luminaire is only marked with the type of protection for dust (IIIC), the cable entries and stopping plugs do not need to meet the requirements for restricted breathing (nr). 9.1.2 Cleaning Clean the device only with a cloth, brush, vacuum cleaner or similar items. When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching cleaning agents. Do not use aggressive detergents or solvents. 9.2 Repair Explosion hazard due to improper repair! Non-compliance results in severe or fatal injuries. Repair work on the devices must be performed only by R. STAHL Schaltgeräte GmbH. 9.3 Returning the device Use the "Service form" to return the device if repair or service is required. On the internet site "www.stahl-ex.com" under "Downloads > Customer service": Download the service form. Fill out the service form. Send the device along with the service form in the original packaging to R. STAHL Schaltgeräte GmbH. Floodlight LED 19

Disposal 10 Disposal Observe national and local regulations and statutory regulation regarding disposal. Separate materials when sending it for recycling. Ensure environmentally friendly disposal of all components according to the statutory regulations. 11 Accessories and Spare parts NOTICE Malfunction or damage to the device due to the use of non-original components. Non-compliance can result in material damage. Use only original accessories and spare parts from R. STAHL Schaltgeräte GmbH. For accessories and spare parts, see data sheet on our homepage www.r-stahl.com. 20 Floodlight LED