Breathing Circuits. Product training

Similar documents
Breathing Systems. Professor Khalid Bashir

DAR History page Anaesthesia Breathing Circuits page

DAR: Our History page Anaesthesia Breathing Circuits page

Selecting and Connecting Breathing Systems

LISTADO DE CIRCUITOS DE PACIENTE

Breathing systems. Non-rebreathing system using a unidirectional valve pair. Non-rebreathing systems

Anesthesiology Research and Scholarship. Follow this and additional works at:

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

Anesthesia Breathing Circuit

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

International Journal of Science, Environment and Technology, Vol. 5, No 5, 2016,

Recommendations on Checking Anaesthesia Delivery Systems

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Great products available through ROI!

DPA 02 TM Diamedica Portable Anaesthesia System INSTRUCTIONS AND USER GUIDE

We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

Heated Wire - Neonate Ø10mm Infant Ø12mm

Keeping anaesthetic pollution to minimum in theatre environment

ekom Compressor for Medical Air Sonata with Ekom

Medical Instruments in the Developing World

27/10/58. Background and Rationale. Background and Rationale. Background and Rationale. Objective. Background and Rationale

Anesthesia Machine Intro

Flow meter. bellow vaporizer. APL valve. Scavenging system

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

GE Healthcare. Aestiva/5. More than superior ventilation

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Sterile product catalogue

Draeger Fabius GS Pre-Use Check

System Flow Chart. ventilation patient connection

Homecare Pneumology NEONATOLOGY ANAESTHESIA INTENSIVE CARE VENTILATION Step beyond the future

The centerpiece of a comprehensive anaesthesia workstation

Checking a Breathing System

Operation and Maintenance of the EPV200 Portable Ventilator

M5400 Operators Manual

Aespire 7100 Essential performance Compact design

Historically, rebreathing anesthesia systems

Table of contents. Breathing Circuit. Neonatal Care. Anesthesia Circuit. Accessories

General Anaethesia Airway

State-of-the-art anesthesia technology

Mechanical Ventilation

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

INTRODUCTION. EN ISO 13485: AC:2012, EN ISO 9001:2008

Anesthesia. Midmark Animal Health Products

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care


Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Comparison Of The Efficacy Of Two Low Fresh Gas Flow Techniques In Low Flow Anaesthesia

respiratory care aerosol therapy

Guidelines on Monitoring in Anaesthesia

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

CATALOGUE. Adult and Infant Respiratory Care Catalogue

Health Professional Info

TUBINGS / CONNECTION PIECES

Corporate Overview and Product Summary

D Accessories that actively cooperate DRÄGER INFINITY ID-ACCESSORIES

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

NARKOVET ANAESTHETIC UNIT

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

URN (UNIVERSAL RODENT NOSE CONE) (17mm diameter) Figure 1

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

Anaesthesia breathing circuits

Hallowell EMC Anesthesia WorkStation Operating Manual

FRESH GAS UTILIZATION OF EIGHT CIRCLE SYSTEMS

TOPO. operating Manual

The anaesthesia workstation focused on you

MACS Mask CPAP System

Technical Data and Specifications

Index. Filtration and cross contamination 3. Mechanical filters Sterivent range 8 Sterivent range configurations 9

Anaesthetic infrastructure and supplies

Inspire rpap REVOLUTION FROM THE FIRST BREATH

Anesthesia Products & Circuits

Welcome to Maxstar Medical

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Merlin Training for Vets and Nurses

Anes Machine Use and Pre-use Check - CA1 focus

INTENSIVE CARE VENTILATORS

AUTOVENT 4000 VENTILATOR

QED-100 Clinical Brief

Siesta i Whispa Integrated technology

Respiratory Care. and Aerosol Therapy

II. Set up the monitor

ANAPOD. The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature. Heated Humidification System for Anesthesia

ACUC ۰ ROUTINE PROCEDURE

GE Healthcare. Avance Carestation. Upgrade promotions guide

Ventilators. Dr Simon Walton Consultant Anaesthetist Eastbourne DGH KSS Basic Science Course

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

Mechanical Ventilation

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

The anaesthesia workstation focused on you

Monitoring, Ventilation & Capnography

CLINICAL ANAESTHESIA AND THE MULTIPLE-GAUZE CONDENSER-HUMIDIFIER

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

Disclosures. The Pediatric Challenge. Topics for Discussion. Traditional Anesthesia Machine. Tidal Volume = mls/kg 2/13/14

PRODUCT CATALOG. Every Breath Matters. ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck Cowan Road Tucker, GA 30084

Hallowell EMC Vacuum / Scavenging Interface

Transcription:

Breathing Circuits Product training

Agenda Introduction to Breathing Circuits Anaesthesia Circuits Intensive Care Circuits Accessories 2 Covidien

Introduction 3 Covidien

What is a breathing circuit? In general, a breathing circuit is a system of tubes and accessories connecting the patient to an Anaesthesia equipment or to an Intensive Care ventilator Elements -Tubes -Water traps -Y-piece -Breathing Bags -Valves 4 Covidien

Anaesthesia Circuits Clinical practice 5 Covidien

The process of Anaesthesia Anesthesia: the process by which a patient is rendered able to undergo surgery Goals: Anaesthesia: lack of awareness of surrounding events Akinesia: keeping the patient still to allow surgery to take place Muscle relaxation: to enable access through muscles to bones and body cavities Autonomic control: to prevent dangerous surges in hemodynamics 6 Covidien

Anaesthesia and its stages Premedication conducted in the surgical ward or preoperative holding area Aim is to have patient arrive in the operating room in a calm, relaxed frame of mind while causing minimal interference with breathing and cardiovascular status Administered orally or intravenously 7 Covidien

Anaesthesia and its stages Induction From awake to anesthetized patient Administered intravenously or by slow inhalation of anaesthetic vapours or combination of both Combined with narcotic analgesia Natural breathing or endotracheal intubation ET tube needed if muscle relaxant is administered 8 Covidien

Anaesthesia and its stages Maintenance Keep patient anesthetized with a maintenance agent Delivery of anesthetic gases into the patient s lungs Inhaled as the patient breathes himself or delivered under pressure by each mechanical breath of a ventilator Level of anesthesia altered to give the minimum amount necessary to ensure adequate anesthetic depth 9 Covidien

Anaesthesia and its stages I m awake again! Anaesthetic vapors decreased or switched off Musle relaxation is reversed Long-acting narcotic analgesic to keep patient comfortable in the recovery room Patient is restored to breathing by himself Removal of the endotracheal tube only performed when the patient has regained sufficient control of airway reflexes 10 Covidien

What is an anaesthetic circuit? Assembly of components to connect the patient s airway to the anaesthetic machine Fresh gas entry port Exhalation valve (APL) Patient connection Reservoir bag/tube 11 Covidien

What does it need to do? Deliver the gases from the machine to the alveoli in the same concentration as set and in the shortest possible time Effectively eliminate CO2 Minimal dead space and low flow resistance Economy of fresh gas Adequate humidification of inspired gas Light weight, compact and sturdy Efficiency during spontaneous as well as controlled ventilation Efficient removal of waste exhaled gases 12 Covidien

Several Classifications Open Semiclosed Closed no rebreathing partial rebreathing total rebreathing MacMohan, 1951 Mapleson, 1954 Semi-Closed Systems The arrow indicates the fresh gas flow entry 13 Covidien

Mapleson systems Elimination of CO2 with these systems depends on FGF Mapleson systems functioning can change depending on parametres change, such us: FGF, dead space etc. FGF is crucial for breathing system working. If there is no FGF patient will not be ventilated. If FGF is too low, majority of systems doesn t effectively remove CO2. If FGF is too high, anesthetic gases are being lost. Setting appropriate FGF is the key here. 14 Covidien

Magill/Mapleson A Breathing System Mechanism of action of the Magill Breathing System during spontaneous ventilation FGF = fresh gas flow 15 Covidien

Lack Breathing System a) Coaxial Lack Breathing System b) Parallel Lack Breathing System 16 Covidien

Mapleson B and C Fresh gas entry near the patient to optimise FGF and reduce rebreathing during controlled ventilation FGF and exhaled gases are mixed: not very efficient neither during spontaneous or controlled ventilation Also known as MBU or bagging system Used also in ICU and Emergency 17 Covidien

Mapleson D, E, F Breathing System Reservoir is in the limb which carries expired gas from the patient and vents it to the atmosphere through the expiratory valve/port. This to reduce FGF requirements Work efficiently for controlled ventilation if FG entry and expiratory valve are separated by a volume equivalent to at least one tidal volume of the patient Not economical during spontaneous breathing. 18 Covidien

Mapleson D during spontaneous breathing 19 Covidien

Bain Breathing System Coaxial version of the Mapleson D Fresh gas flows along the inner tube and the exhaled gases flow along the outer tube Not efficient for spontaneous ventilation Fresh gas flow rate required is 150-200 ml/kg/min Efficient during controlled ventilation Fresh gas flow rate required is 70-100 ml/kg/min 20 Covidien

Circle Breathing Systems (semi-closed and closed system) Soda lime canister with two unidirectional valves attached to inspiratory and expiratory tubings APL valve and reservoir bag are connected to the canister Soda lime consists of 94% calcium hydroxide, 5% sodium hydroxide and a small amount of potassium hydroxide Soda lime absorbs the exhaled carbon dioxide and produces water and heat Very efficient breathing system using low fresh gas flow and reducing pollution A high initial flow is required 21 Covidien

Circle Breathing Systems 22 Covidien

Anaesthesia Circuits DAR range 23 Covidien

DAR: a very comprehensive range Standard configurations for : 1. Anaesthesia 2. Intensive Care 3. Neonatology 4. Home Care Custom made program: special breathing systems can be designed according to customer s needs 24 Covidien

Which material? 1. Smoothbore PVC - single use 2. Extendible Corrugated PP (Darmonia) - single use 3. Polyethylene - single use 4. Smoothbore Hytrel autoclavable (up to 20 times, temp. 121 123 C) 25 Covidien

Advantages of Smoothbore PVC Internally Smooth Clear Very resistant Low Compliance Flex connector 10, 15, 22 mm Single Use Custom made option 26 Covidien

Polypropylene (Darmonia) Space saver Extendible Lightweight Low cost Disposable 22 mm only (adult) 27 Covidien

Material and size 22 mm Adult 15 mm Paediatric 10 mm Neonatal PVC x x x PVC Heated Wire x x x PE PP x x Hytrel x x 28 Covidien

Questions to ask to offer the right circuits in anaesthesia 1. Type of patient being treated (adult, pediatric, neonates) this will determine the diameter and material we can offer 2. Type of anaesthesia: closed or semiclosed; this will determine if they need a mapleson system or a standard y-piece; closed with low flow: this might often require water traps 3. Preferred material: help by describing features 4. Diameter inspiratory/expiratory connector on ventilator: usually 22M for adult ventilators 5. Length of tube for connection between y-piece and ventilator 6. Length of extra limb with breathing bag (if needed) 7. Size of bag (1/2 l, 1 l, 2 l, 3 l): 2 l usually for adult patients 8. Accessories: elbow with CO2 port, filters, pressure line 29 Covidien

Basic Y-piece circuit Available in all materials Extendible in 22 mm only Various lengths available Can be supplied with temp and pressure ports on the Y piece (usually for ICU) Can be supplied with water trap (ICU) Can be supplied with heated wire limb for use with hot water bath humidifiers (ICU) Suitable for use with closed systems 30 Covidien

Triplex: 3-lines-in-1 The inspiratory limb is inserted in the external expiratory limb An additional line for capnography to be connected directly to the instrument The circuit is built using three different materials: PVC for the inner line PE for the outer line PP for the extendible limbs 31 Covidien

Why Triplex Light, flexible and less bulky than conventional circuits Fresh gases are heated and maintain their humidity without using additional devices Just one tube in the area of patient s head No need to change the circuit for patient transportation DUO (no capnoline) for ICU also with FHME 130, 200, 260 cm 32 Covidien

Anaesthesia circuit with machine side filters 33 Covidien

Anaesthesia circuit with patient side filters 34 Covidien

Intensive Care Circuits 35 Covidien

Questions to ask to offer the right circuits in ICU 1. Type of patient being treated (adult, pediatric, neonates) this will determine the diameter and material we can offer 2. Type of humidification: active or passive: this will determine if they need a standard y-piece or a heated/water trap circuit 3. Preferred material: help by describing features 36 Covidien

Circuit for active humidification 10 9 8 YES NO 1 2 5 6 7 YES NO TYPE: 3 4 HUMIDIFIER Swivel connector Angled Straight 37 Covidien

Circuit for active humidification Check for the following parameters! 1. Diameter inspiratory connector on ventilator - female or male (usually 22M for adult ventilators) 2. Length of tube for connection between ventilator and humidifier 3. Diameter inlet connector on humidifier (usually 22M or 15F) 4. Diameter outlet connector on humidifier (usually 22M) 5. Length of inspiratory limb between humidifier and water trap 38 Covidien

Circuit for active humidification Check for the following parameters! 6. Length of inspiratory limb between water trap and Y -piece 7. Type of Y -piece (available with pressure & temperature ports at different I.D.) 8. Length of expiratory limb between Y -piece and water trap 9. Length of expiratory limb between water trap and ventilator 10. Diameter expiratory connector on ventilator -female or male (usually 22M for adult ventilators) 39 Covidien

DAR embedded heated wire circuits The DAR smooth bore circuits with heated wire built in outer tube spiral Target: ICU s (Neonatal) Unique product Compatible with all active humidifiers such as Kendall, F&P, Hudson, DAR 40 Covidien

DAR embedded heated wire circuits Product Positioning The unique embedded heated wire circuit to ensure maximum safety for patients and staff Can be customised for specific needs Objectives Penetrate ICU s breathing systems market where Filter/HME s are not used (esp. Neonatal) Obtain premium price Increase customer loyalty by offering the most complete range of circuits 41 Covidien

Basic Y-piece circuit Available in all materials Extendible in 22 mm only Various lengths available Can be supplied with temp and pressure ports on the Y piece (usually for ICU) Can be supplied with water trap (ICU) Can be supplied with heated wire limb for use with hot water bath humidifiers (ICU) Suitable for use with closed systems 42 Covidien

ICU circuit without patient side filter always water bath humidifier and inspiratory and expiratory water traps/heated tubing 43 Covidien

ICU circuit with patient side filter no water bath humidifier breathing system without water traps! 44 Covidien