Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance

Similar documents
Proof Copy. Controlling the Walking Period of a Pneumatic Muscle Walker. Takashi Takuma Koh Hosoda. Abstract. 1. Introduction

3D Limit Cycle Walking of Musculoskeletal Humanoid Robot with Flat Feet

3D Bipedal Robot with Tunable Leg Compliance Mechanism for Multi-modal Locomotion

Body Stabilization of PDW toward Humanoid Walking

Toward a Human-like Biped Robot with Compliant Legs

Toward a Human-like Biped Robot with Compliant Legs

OPTIMAL TRAJECTORY GENERATION OF COMPASS-GAIT BIPED BASED ON PASSIVE DYNAMIC WALKING

Emergent walking stop using 3-D ZMP modification criteria map for humanoid robot

Compliance Control for Biped Walking on Rough Terrain

Learning Energy Efficient Walking Based on Ballistics

Effects of Ankle Stiffness on Gait Selection of Dynamic Bipedal Walking with Flat Feet

Dynamically stepping over large obstacle utilizing PSO optimization in the B4LC system

Learning Energy Efficient Walking with Ballistic Walking

Humanoid Robots and biped locomotion. Contact: Egidio Falotico

Walking Experiment of Biped Robot with Antagonistic Actuation Using Non-Linear Spring

Toward a human-like biped robot with compliant legs

ZMP Trajectory Generation for Reduced Trunk Motions of Biped Robots

Book Review. I. Background

Robots With Legs. Helge Wrede

YAN GU. Assistant Professor, University of Massachusetts Lowell. Frederick N. Andrews Fellowship, Graduate School, Purdue University ( )

Asymmetric Passive Dynamic Walker

Using GPOPS-II to optimize sum of squared torques of a double pendulum as a prosthesis leg. Abstract

A Bio-inspired Behavior Based Bipedal Locomotion Control B4LC Method for Bipedal Upslope Walking

From Passive to Active Dynamic 3D Bipedal Walking - An Evolutionary Approach -

Sample Solution for Problem 1.a

Motion Control of a Bipedal Walking Robot

Powered Bipeds Based on Passive Dynamic Principles

Decentralized Autonomous Control of a Myriapod Locomotion Robot

Emergency Stop Algorithm for Walking Humanoid Robots

-Elastic strain energy (duty factor decreases at higher speeds). Higher forces act on feet. More tendon stretch. More energy stored in tendon.

Walking and Running BACKGROUND REVIEW. Planar Pendulum. BIO-39 October 30, From Oct. 25, Equation of motion (for small θ) Solution is

Trajectory Planning for Smooth Transition of a Biped Robot

Biomechanics and Models of Locomotion

Faster and Smoother Walking of Humanoid HRP-2 with Passive Toe Joints *

Limit Cycle Walking and Running of Biped Robots

In memory of Dr. Kevin P. Granata, my graduate advisor, who was killed protecting others on the morning of April 16, 2007.

Journal of Chemical and Pharmaceutical Research, 2016, 8(6): Research Article. Walking Robot Stability Based on Inverted Pendulum Model

RECENTLY, various humanoid robots have been

Foot Placement in the Simplest Slope Walker Reveals a Wide Range of Walking Solutions

Effects of a Passive Dynamic Walker s Mechanical Parameters on Foot- Ground Clearance

Design and control of a pneumatic musculoskeletal biped robot

INITIATING NORMAL WALKING OF A DYNAMIC BIPED WITH A BIOLOGICALLY MOTIVATED CONTROL

SUPPORTING ONLINE MATERIAL for Efficient bipedal robots based on passive-dynamic walkers

John Sushko. Major Professor: Kyle B. Reed, Ph.D. Rajiv Dubey, Ph.D. Jose Porteiro, Ph.D. Date of Approval: October 21, 2011

RUNNING ON SOFT GROUND: SIMPLE, ENERGY-OPTIMAL DISTURBANCE REJECTION

Generation of Robot Motion Based on Measurement of Human Movement. Susumu Sakano 1, Satoru Shoji 1

Gyro stabilized biped walking

Stability Control of Bipedal Walking Robot

ZSTT Team Description Paper for Humanoid size League of Robocup 2017

Energetics of Actively Powered Locomotion Using the Simplest Walking Model

A NEW GOLF-SWING ROBOT MODEL UTILIZING SHAFT ELASTICITY

Optimal Gait Primitives for Dynamic Bipedal Locomotion

SUPPORTING ONLINE MATERIAL for Efficient bipedal robots based on passive-dynamic walkers

Human Pose Tracking III: Dynamics. David Fleet University of Toronto

Human-Oriented Biped Robot Design: Insights into the Development of a truly Anthropomorphic Leg

Biped Passive Dynamic Walking: A Review

Compliance for a cross four-bar knee joint

SHUFFLE TURN OF HUMANOID ROBOT SIMULATION BASED ON EMG MEASUREMENT

SIMULATION AND EXPERIMENTAL STUDIES ON WALKING ROBOT WITH FLEXIBLE LEGS

Robot motion by simultaneously wheel and leg propulsion

DETC DESIGN OPTIMIZATION OF A NOVEL TRIPEDAL LOCOMOTION ROBOT THROUGH SIMULATION AND EXPERIMENTS FOR A SINGLE STEP DYNAMIC GAIT

Computer Aided Drafting, Design and Manufacturing Volume 26, Number 2, June 2016, Page 53. The design of exoskeleton lower limbs rehabilitation robot

EXPERIMENTAL STUDY OF EXOSKELETON FOR ANKLE AND KNEE JOINT

Skippy: Reaching for the Performance Envelope

A Study on the End-Effector Exchange Mechanism of a Space Robot

Computer Simulation of Semi-Passive Walking Robot with Four Legs and Verification of It s Validity Using Developed Experimental Robot

Kungl Tekniska Högskolan

Centre for Autonomous Systems

Dynamic analysis and motion measurement of ski turns using inertial and force sensors

Gait Pattern Generation and Stabilization for Humanoid Robot Based on Coupled Oscillators

Stable Upright Walking and Running using a simple Pendulum based Control Scheme

Experimental Results on the First Movements of the Pneumatic Biped Lucy

An autonomous, underactuated exoskeleton for loadcarrying augmentation

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

How Do You Swing? You should be working with new lab partners starting with this lab.

Fail Operational Controls for an Independent Metering Valve

WALKING MOTION ANALYSIS USING SMALL ACCELERATION SENSORS

Improvement of the Cheetah Locomotion Control

Swing leg retraction helps biped walking stability

The Design and Control of a Bipedal Robot with Sensory Feedback

Development of Wearable Sensor Combinations for Human Lower Extremity Motion Analysis

A 3D passive dynamic biped with yaw and roll compensation M. Wisse*, A. L. Schwab**, R. Q. vd. Linde*

Shuuji Kajita and Kazuo Tani

Spider Robot for Motion with Quasistatic. Force Constraints

Gait Analysis of a Little Biped Robot. Received May 2015; accepted July 2015

Simulation of the Hybtor Robot

BUILDING A BETTER PASSIVE WALKER

INSTANTANEOUS ON-LINE MODIFICATION OF BIPED WALK COMPOSED FROM RECONFIGURABLE ADAPTIVE MOTION PRIMITIVES

Gait analysis for the development of the biped robot foot structure

Spring Locomotion Concepts. Roland Siegwart, Margarita Chli, Martin Rufli. ASL Autonomous Systems Lab. Autonomous Mobile Robots

Truba college of Engineering & Technology, Indore, India. Truba college of Engineering & Technology, Indore, India.

ON PASSIVE MOTION OF THE ARMS FOR A WALKING PLANAR BIPED

University of Twente

A Neuromuscular Model of Human Locomotion and its Applications to Robotic Devices

E.I. Kugushev, 7.6. Jaroshevskij Institute of Applied Mathematics, the USSR Academy of Sciences, Moscow, A-47, Miusskaya Sq», 4

Impact Points and Their Effect on Trajectory in Soccer

CHARACTERISTICS OF LEAK DETECTION BASED ON DIFERENTIAL PRESSURE MEASUREMENT

Study of Dynamic Biped Locomotion on Rugged Terrain - Derivation and Application of the Linear Inverted Pendulum Mode -

Managing and Recycling Human Energy: A Mechanical Redesign of the UCSC Lower Limb Exoskeleton. Rachel Rieger, Jacob Rosen

Craig Honeycutt. Major Professor: Kyle Reed, Ph.D. Rajiv Dubey, Ph.D. Jose Porteiro, Ph.D. Date of Approval: October 21, 2011

Transcription:

Controlling Walking Behavior of Passive Dynamic Walker utilizing Passive Joint Compliance Takashi TAKUMA, Koh HOSODA Department of Adaptive Machine Systems, Graduate School of Engineering Osaka University Yamadaoka 2-1, suita, Osaka, Japan {takuma, hosoda}@ams.eng.osaka-u.ac.jp Abstract The passive dynamic walker (PDW) has a remarkable characteristic that it realizes cyclic locomotion without planning the joint trajectories. However, it cannot control the walking behavior because it is dominated by the fixed body dynamics. Observing the human cyclic locomotion emerged by elastic muscles, we add the compliant hip joint on PDW, and we propose a phasic dynamics tuner that changes the body dynamics by tuning the joint compliance in order to control the walking behavior. The joint compliance is obtained by driving the joint utilizing and McKibben pneumatic actuators. This paper shows that PDW with the compliant joint and the phasic dynamics tuner enhances the walking performance than present PDW with passive free joints. The phasic dynamics tuner can change the walking velocity by tuning the joint compliance. Experimental results show the effectiveness of the joint compliance and the phasic dynamics tuner. I. INTRODUCTION One of the interesting characteristics of human locomotion is that they realize stable cyclic locomotion. Cyclic locomotion is obtained by phasic actuation [1] on the passive joints, and it does not require planning the joint trajectories. On the other hand, present bipedal walkers plan joint trajectories based on some criteria such as Zero Moment Point [2] or an inverted pendulum model [3]. Although the bipedal walkers realize stable locomotion utilizing such approaches, they require precise models of robot dynamics and environment to calculate the joint trajectories. The passive dynamic walker (PDW) also realizes cyclic locomotion without planning the joint trajectories [4]. PDW walks on shallow slope utilizing its body dynamics and the interaction with the terrain. It also walks on flat plane with simple actuation [5]. However, it cannot change its walking behavior because the behavior is dominated by body dynamics, and each dynamics of the present PDW is fixed. Observing human locomotion, it seems that they change their dynamics by tuning the joint compliance to control control the walking. In [6], though it is case of running, the hip joint compliance is changed according to desired stride frequency. Although some researches on bipedal walkers have also reported the importance of compliant joints [7], [8], there is no report that shows a contribution of the joint compliance by the physical bipedal walker to the best of our knowledge. In this paper, the hip joint compliance is focused to realize enhanced walking performance of the PDW. We propose a phasic dynamics tuner to change the robot dynamics by tuning the joint compliance. By utilizing the phasic dynamics tuner, this paper shows experiment results that the walking velocity is changed by tuning the joint compliance. This result shows that the joint compliance contributes to enhance the walking performance of the PDW. In order to change the hip joint compliance, the McKibben pneumatic actuator [9], [10] is adopted. The McKibben pneumatic actuator has elasticity and that can be changed according to the inner pressure. We set the actuators on and position around the joint in order to change joint compliance as well as actuation. The actuator is driven by opening supply / expel valves, and the phasic dynamics tuner is realized by determining the duration to open / close supply / expel valves. In order to show the contribution of the joint compliance, we have experiments to observe the walking performance when the robot walks with passive free hip joint and when the robot walks with passive compliant joint. II. A 2D BIPEDAL WALKER WITH PNEUMATIC ACTUATORS A. Joint mechanism driven by pneumatic actuators It is expected that passive compliance of the robot joint contributes to operate a walking behavior, walking velocity in this paper, of the passive walker. In order to realize the passive hip joint compliance, it is effective to adopt the joint mechanism driven by the and McKibben pneumatic actuators [7]. Figure 1 shows the architecture of a planar bipedal walker driven by the pneumatic actuators. When the air is supplied into the actuator, the actuator shrinks, generating tensile force. The actuator has a nonlinear springy nature, and the stiffness increases according to the increase in the pressure. The joint compliance is therefore determined by the pressure of the actuators. Three-position solenoid valves are adopted to operate the pressure. The valve switches three states: supplying air from the source, expelling air to the atmosphere, and closing valves to quit both supplying and expelling. Figure 2 shows a pressure profile when the compressed air ( MPa) is supplied into the actuator. The solid line shows the profile when the supply valve is always open. It takes about 0.8 s to reach MPa. Considering that the supply / expel valve can be closed at arbitral time and that the response time to open / close valve

0.7 on/off touch information Single chip micro computer H8 air flow Air bottle three position solenoid valve with closed center position pressure [MPa] 0.4 0.3 0.2 infinete 0.25 [s] 0.15 [s] 0.1 [s] 6.0 [MPa] 4.6 [MPa] 3.5 [MPa] 2.7 [MPa] 0 0.2 0.4 0.8 1 time [s] Fig. 2. Pressure profile after opening supply valve. The air of [MPa] is fulfilled for 0.8 [s] (solid line). The pressure is controlled by tuning the supply duration (broken line : closed at 0.1, 0.15, and 0.25 s). touch sensor Fig. 1. Architecture of a planar bipedal walker driven by McKibben pneumatic actuators. The main feature of the walker is the threeposition solenoid valve with a closed center position that enables the robot to control joint compliance. is less than 0.03 s, it is possible to stop supplying / expelling before the air is completely fulfilled or expelled. By tuning the duration to open the valve, it is possible to realize continuous pressure change. Broken lines in Figure 2 show the pressure profile when the valve is open for certain period (0.1, 0.15, and 0.2 s) and then close. When the duration is shorter, the pressure after closing the valve is lower and vice versa. Because joint compliance is changed according to the pressure, joint compliance is then controlled by tuning the durations to open supply / expel valve. The difference between [11] is that [11] adopts a two-position solenoid valve that either supplies or expels. Therefore, it cannot maintain certain compliance of the joint. B. Specification Figure 3 shows real-world prototype Que-kaku. All of the joints are driven by McKibben pneumatic actuators [9], [10] by HITACHI Medical Corporation [12]. The length and radius (in contraction) of the actuators are 0.15 m and 0.027 m, respectively. The prototype generates approximately 800 N when the pressure is 0.7 MPa. The walker has three joints: two knees and one hip. All joints are driven by the pneumatic actuators. It is 0.75 m high, 0.35 wide, and weighs 5.0 kg. Its four legs keep it from swaying side to side. The legs are connected in pairs. The thigh is 0.3 m long and weighs 2.16 kg, and the shank is 0.35 m long and weighs 0.48 kg. The self-contained robot has two 1.2 MPa CO 2 bottles weighing 0.7 kg each with regulators as air sources, a micro- Fig. 3. A 2D bipedal walker driven by McKibben pneumatic actuators. The robot is self-contained and has two air bottles with regulators, three-position air valves, a microcomputer board, and an electrical battery. computer (H8), and an electrical battery weighing 1.0 kg. The robot s six three-position solenoid valves (SMC Corporation [13] SYJ3340-6M-M5) weigh a total of kg. The regulator on each bottle maintains air pressure at 5 MPa, and valves supply regulated air to muscles. Its feet have round soles with a curvature of 0.125 m and 0.08 m long. Its on / off switches detect contact with the ground (Figure 1). Based on on / off information fed to the microcomputer, the computer outputs open and close commands to solenoid valves. III. PHASIC DYNAMICS TUNER FOR LIMIT CYCLES It is important for the passive walker to design a robot dynamics including the center of mass and the radius of feet. We designed them by try and error to enable the robot to walk on a flat plane using simple phasic actuation. This paper adopts two feed-forward controller to show the contribution of the

passive joint compliance on changing walking behavior. One is a simple actuation pattern that the robot walks with a free hip joint, and the other is the pattern that names phasic dynamics tuner such that the robot walks with a passive compliant hip joint. By tuning joint compliance, robot dynamics is controlled, and then it is expected that walking behavior is changed. A. Feed-forward Controller for walking with the free hip joint The valve operation procedure is as follows. The valve opening timing chart is shown in Figure 4: (i) Begin to swing a leg by opening the supply valve to the. Let the duration to open the supply valve be T s. (ii) In order to swing with passive free hip joint, the expel valve for the is open until landing. The expel valve for the is always open while walking. (i) ant. Tk ago. (ii) Ts T(k) supply expel close time Fig. 4. Feed-forward controller for walking with free hip joint : activating and relaxing muscles. The rectangles in the picture indicate the and s. Note that the supply duration for the knee actuator T k is tuned so as to avoid foot collision on the ground. T (k) shown in the figure is defined as the walking cycle at the kth step. B. Controller for walking with a passive compliant hip joint (phasic dynamics tuner) The valve operation procedure is as follows. The valve opening timing chart is shown in Figure 5: (i) Begin to swing a leg by opening the supply valve to the. Let the duration to open the supply valve be T s. Expel valve to the is open simultaneously for T e. (ii) Close both supply and expel valves. When the landing signal is fed from on / off switch on the foot, return to (i). In (ii), the air remains after closing the valves. Mentioned in previous section, pressure is determined by supplying / expelling duration, and then the joint compliance is changed by duration T s and T e. (i) Fig. 5. Tk Te (ii) Ts T(k) supply expel close time Timechart for walking with the passive compliant hip joint For each valve procedure, air is supplied to an before walking. A knee of support leg keeps extended by closing both valves of and actuators. A knee of swing leg bends by opening supply valve to an for certain period, T k in Figure, and it extends again by opening expel valve to the. We tune T k to avoid the foot collision on the ground. In the preset paper, we fix T k at 0.3 s. Since the movement of the knee is small, it does not strongly affect the behavior. Pressure profiles of 5 steps on and actuator of the hip joint is shown in Figure 6. Supply duration T s and expel duration T e are T s = 0.2, T e = 0.28 s, respectively. The pressure of the actuator increases due to air supply and the pressure in actuator decreases due to air expel. Each pressure keeps almost same after closing the valve, and both actuators co-contract after both valves are closed. Hip joint compliance keeps same without air consumption while closing both valves. The swing leg travels with the passive compliant hip joint. IV. EXPERIMENT A. Experiment setup The robot walks on the floor using two types of feedforward controller: controller for walking with free hip joint and for walking with compliant hip joint. An average walking velocity is measured by measuring walking cycle and walking distance of the step. The velocity is measured after 10th step assuming that the walking behavior is converged into the limit cycle after 10th step. In both case, the velocity is measured with various walking parameter values. When the robot walks with passive free hip

pressure [MPa] 2.8 2.4 2 1.6 OPEN supply air valve CLOSE supply air valve forward velocity [m/s] 0.7 5 5 0.45 0.4 0.35 1.2 0 0.1 0.2 0.3 0.4 0.7 OPEN expel air valve CLOSE expel air valve 0.05 0.1 0.15 0.2 0.25 0.3 0.35 supply duration Ts [s] Fig. 7. Relationship between supply duration for the T s and average forward velocity when T s = 0.12, 0.14 and 0.16 s when the robot walks with a free hip joint Fig. 6. Pressure profiles of and actuator at one step 0.8 joint, the supply duration T s, a period of phasic actuation, is changed. When the robot walks with passive compliant hip joint, the expel duration T e of the phasic dynamics tuner is changed. By changing the parameter T e of the tuner, the joint compliance as well as the period of phasic actuation is tuned. T s of the tuner is fixed as 0.2 s considering that the compliance can be tuned by changing the expel duration and the supply duration is fixed (see Figure 9). B. Result 1: Walking with a free hip joint Figure 7 shows the relationship between supply duration T s and average walking velocity when the robot walks with a passive free hip joint. The velocity and error indicated correspond to average velocity and error of 20 steps at each supply duration. The robot walks when T s = 0.12, 0.14, and 0.16 s. Even though the energy required to swing a leg increases according to longer supply duration, this result shows that the walking parameter does not control the velocity. The walking velocity is dominated by the robot body dynamics. This result shows that the supply duration to swing the leg is not responsible for controlling the velocity and that it is much dominated by the robot body dynamics. C. Result 2: Walking with a compliant hip joint Figure 8 shows the relation between expel duration T e and the average walking velocity and error. They are obtained from 20 steps at each parameter value. The walking parameter T e is changed from 0.22 sto0.4 s. The walking velocity is higher when T e is shorter. This result shows that the walking parameter controls the walking velocity when the robot walks with the proposed phasic dynamics tuner. D. Relationship between compliance and velocity As shown in the Figure 5, air is supplied to the actuator of the hip joint and expelled from the actuator when the robot walks with the passive compliant hip joint. When the parameter is changed, the pressure profiles of forward velocity [m/s] 0.75 0.7 5 5 0.45 0.2 0.25 0.3 0.35 0.4 expel duration Te [s] Fig. 8. Relationship between expel duration for actuator T e and average forward velocity. both actuators as shown in Figure 6 are varied. As explained in [10], tensional force of the pneumatic actuator is proportional to pressure. Therefore, considering that the pressures after closing supply and expel valves are almost same and that the hip compliance is determined by both pressure, there is a strong correlation between the pressure at heel strike and hip compliance. We then observe the relationship between the compliance and walking velocity from the relationship between velocity and the pressures of and actuator at heel strike. Figure 9 shows the relationship between the walking parameter T e and the pressure in the (left axis) and (right axis) actuators. This relationship shows that the pressure at heel strike is changed according to the parameter. When T e is longer, both pressures are lower. It means, considering that the tensional force is smaller when the pressure is lower, that the hip compliance is lower when T e is longer and vice versa. In order to confirm the relationship between hip joint compliance and velocity, we show the relationship between the pressure of actuator and velocity by combining above results shown in Figure 8 and in Figure 9. Figure 10 shows

actuator pressure [MPa] 0.2 0.18 0.16 0.14 0.12 actuator actuator 0.22 0.26 0.3 0.34 0.38 expel duration Te [s] 0.38 0.37 0.36 0.35 0.34 Fig. 9. Relationship between the walking parameter T e and the pressure in the actuator at heel strike. the relationship between pressure of the actuator and walking velocity. Considering that the joint compliance is higher when the actuator pressure is higher, this result shows that the walking velocity is higher when hip joint compliance is higher and vice versa. We confirmed similar relationship between pressure of the actuator and walking velocity. This result shows that the walking velocity is changed by the joint compliance and that the phasic dynamics tuner controls walking behavior of PDW. forward velocity [m/s] 0.8 0.75 0.7 5 5 0.45 0.1 0.12 0.14 0.16 0.18 0.2 actuator pressure [MPa] Fig. 10. Relationship between the pressure in the actuator at heel strike and the forward velocity. V. CONCLUSION AND DISCUSSION In this paper, we built real passive walker that has characteristic joint mechanism driven by and McKibben pneumatic actuators. In order to obtain tunable joint compliance, we utilize air valves that switch supplying, expelling, and stopping both supplying and expelling. We showed that the walking behavior, the walking velocity, is changed by tuning the joint compliance. In order to change the passive hip joint compliance, we used the phasic dynamics tuner that tune the hip joint compliance. By changing the joint compliance, the robot dynamics is changed. We then changed the walking parameter of the tuner actuator pressure [MPa] and observed the walking velocity. In order to confirm the contribution of the passive compliant hip joint, we used two types of feed-forward controllers. One is for walking with passive free hip joint, and the other is for walking with passive compliant hip joint (phasic dynamics tuner). We compared the walking performance with free and compliant hip joint. The experimental results showed that the velocity could be controlled by changing walking parameter when the robot walks with passive compliant hip joint. On the other hand, the velocity could not be controlled when the robot walks with passive free hip joint. These results lead us that the velocity could be changed by the phasic dynamics tuner. It is difficult to analyze waling behavior of the passive dynamic walker with the pneumatic actuators because the actuator has complex non-linearity such as a hysteresis. Therefore, it is difficult to explain why the walking velocity is changed by tuning the joint compliance. The issue to analyze remains to be solved. In order to show the contribution of the compliant joint, we will investigate the effect not only of the hip joint but of another joint. One of the candidates to be investigated is an absorption and a reutilization of the collision impact at heel strike by ankle and knee joint. This effect will play important role not only in case of walking but in case of running. Lastly, we discuss the relationship between air consumption and the walking velocity. Figure 11 shows the relationship between air consumption (l per 50 steps) and the expel duration S e while S f is fixed as 0.2 s. Due to the limitation of the experiment space, this result is not observed when the robot walks on the floor explained in previous section but on a treadmill. This result indicates that air consumption is smaller when S e is shorter. Combining this result and the one shown in Figure 8, air consumption is smaller when the walking velocity is higher, S e is shorter, and vice versa. Note that air is consumed for driving the hip joint and knee joint, and it is not corresponding to metabolic cost in human case that includes energy consumption to preserve contracting the muscle. air consumption [l/50 steps] 2.3 2.25 2.2 2.15 2.1 2.05 2 1.95 1.9 1.85 Fig. 11. 0.15 0.2 0.25 0.3 0.35 0.4 expel duration Te [s] relation between expel duration S e(k) and the air consumption

REFERENCES [1] R.Shiavi. Electromyographic patterns in adult locomotion: a comprehensive review. Journal of Rehabilitation Research and Development, Vol. 22, No. 3, pp. 85 98, 1985. [2] S.Kajita, M.Morisawa, K.Harada, K.Kaneko, F.Kanehiro, K.Fujiwara, and H.Hirukawa. Biped walking pattern generator allowing auxiliary zmp control. In Proceedings of IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 2993 2999, 2006. [3] S.Kajita, F.Kanehiro, K.Kaneko, K.Fujiwara, K.Yokoi, and H.Hirukawa. Biped walking pattern generation by a simple three-dimensional inverted pendulum model. Advanced Robotics, Vol. 17, No. 2, pp. 131 147, 2003. [4] T. McGeer. Passive dynamic walking. International Journal of Robotics Research, Vol. 9, No. 2, pp. 62 82, 1990. [5] F. Asano, M. Yamakita, N. Kawamichi, and Z. W. Luo. A novel gait generation for biped walking robots based on mechanical energy constraint. In Proceedings of the 2002 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 2637 2644, 2002. [6] C.T.Farley and O.González. Leg stiffness and stride frequency in human running. Journal of Biomechanics, Vol. 29, No. 2, pp. 181 186, 1996. [7] R.Q.van der Linde. Passive bipedal walking with phasic muscle contraction. Biological Cybernetics, Vol. 81, No. 3, pp. 227 237, 1999. [8] A. D. Kuo. Energetics of actively powered locomotion using the simples walking model. Journal of Biomechanical Engineering, Vol. 124, No. 1, pp. 113 120, February 2002. [9] C. P. Chou and B. Hannaford. Measurement and modeling of mckibben pneumatic artificial muscles. IEEE Transactions on Robotics and Automation, Vol. 12, No. 1, pp. 90 102, 1996. [10] R. Q. van der Linde. Design, analysis, and control of a low power joint for walking robots, by phasic activation of mckibben muscles. IEEE Transactions on Robotics and Automation, Vol. 15, No. 4, pp. 599 604, 1999. [11] M. Wisse and J. van Frankenhuyzen. Design and construction of mike ; 2d autonomous biped based on passeive dynamic walking. In 2nd International Symposium on Adaptive Motion of Animals and Machined (AMAM), 2002. [12] HITACHI Medical corporation web page. http://www.hitachimedical.co.jp/english/index.htm. [13] Smc web page. http://www.smcworld.com.