DM80VC / DC80VC. Two-Stage Variable Speed Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Similar documents
Fully insulated, heavy-gauge steel cabinet stage or single-stage thermostats

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

LENNOX SLP98UHV DIAGNOSTIC CODES

MAINLINE MLA14 AIR CONDITIONERS

COOKTOP SAFETY DANGER WARNING

Industrial Regulator Series 1800/2000

Inductive Proximity Sensors Global Plus Prox

This parts list is current as of the above revision date. See for the current revision.

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

USER S INFORMATION MANUAL

AIR CONDITIONERS WA14**W SERIES

Required Indoor Draft Hood. Optional Outdoor Vent Cap

MPS-003AG-005AG

Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors

ACCESSORY KIT INSTALLATION INSTRUCTIONS

AIR CONDITIONERS WA14 SERIES

INSTALLATION GUIDE Gas Rangetops

RB 4000 Commercial & Industrial Regulator

INSTALLATION INSTRUCTIONS 24" (61.0 CM) GAS SINGLE AND DOUBLE BUILT-IN OVEN

ACCESSORY KIT INSTALLATION INSTRUCTIONS

AE R1 February 2015

INSTALLATION INSTRUCTIONS

Installation Instructions

PROPORTIONAL PRECISION PRESSURE REGULATOR REGTRONIC SERIES

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

Your safety and the safety of others are very important.

ACCESSORY KIT INSTALLATION MANUAL

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

GUARDEX Pump/Motor Mounts & Couplings

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Stainless steel valves for corrosive environments & water base fluids

If you want to offer a more professional look to your

INSTALLATION INSTRUCTIONS

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

VR8205S,T Direct Ignition Combination Gas Controls

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES

BUBBLER CONTROL SYSTEM

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation Instructions

Liquid Level Controls

This parts list is current as of the above revision date. See for the current revision.

Installation Instructions For Natural Gas Conversion

Installation Instructions

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES

GM Series Dual-Block Multi-Function Gas Control Valves

B2KL: 6-way ball valve with male thread, PN 16

Prestige Solo Prestige Excellence 24-32

VR46.5V(A)/VR86.5V(A) SERIES

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

55.109/1. BUT: Three-way unit valve, PN 16. Sauter Components

BUBBLER CONTROL SYSTEM

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

SPECIFICATIONS ATTENTION

ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347

Aquavar SOLO 2 Frequently Asked Questions

Saf-T Vent EZ Seal Plus

LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

If you want to offer a more professional look to your

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F23, F24, F25, F26, F38, F39, F40 & F41

ACCESSORY KIT INSTALLATION INSTRUCTIONS

DANGER WARNING IMPORTANT

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Automatic Valve Proving Control

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

ALF400 to 900, ALT-5/-9

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES

6000SLX HYDRAULIC CRAWLER CRANE

Natural Gas to L.P. Gas Conversion Kit

VR8105, VR8205, and VR8305 Direct Ignition Combination Gas Controls

Remotely-installed Hydraulic Module

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES

Propane Conversion Kit Instruction

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Products no longer available

GAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT

OC Panel High Limit Aquastat Kit, Manual Reset p/n

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES

2/2-Way Proportional Valve (motor-driven)

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

2/2-Way Solenoid Control Valve

TECHNICAL SPECIFICATIONS mA Output MAIN FEATURES

GAS SUPPLY DESIGN GUIDE

CALEFFI. Ball zone valves. series /03 GB

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

ML OXIPRES INSTRUCTION MANUAL

Model 1800 PFM Series Regulator

Transcription:

M80V / 80V Two-Stage Variable Speed Gas Furnace 80% FUE Heating Input: 60,000 100,000 TU/h ontents Nomenclature...2 Product Specifications...3 imensions...5 irflow ata...7 Wiring iagram...14 ccessories...15 Standard Features omfortnet ommunicating Systems compatible Heavy-duty stainless-steel dual-diameter, tubular heat exchanger Two-stage gas valve provides quiet, economical heating urable Silicon Nitride igniter Quiet two-speed draft inducer Utilizes omfortnet communicating, two-stage or single-stage thermostats Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display olor-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation uto-omfort and enhanced dehumidification modes available alifornia Low NOx emissions-compliant models available HRI ertified; ETL Listed abinet Features Multi-position installation: M80V: Upflow, horizontal left or right. 80V: ownflow, horizontal left or right. onvenient left or right connection for gas and electrical service abinet air leakage (QLeak) 2% Heavy-gauge steel cabinet with durable baked-enamel finish Fully insulated heat exchanger and blower section * omplete warranty details available from your local dealer or at www.daikincomfort.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), the 12-Year Unit Replacement Limited Warranty and the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. dditional requirements for annual maintenance are required for the Unit Replacement Limited Warranty. Online registration and some of the additional requirements are not required in alifornia or Quebec. SS-M80V www.daikincomfort.com 5/17 Supersedes 10/16

Nomenclature M 80 H E 060 3 X * * 1 2 3,4 5 6 7,8,9 10 11 12 13 14 rand Minor Revision - aikin rand - Initial Release - 1st Revision onfiguration M - Upflow/Horizontal Major Revision - ownflow/horizontal - Initial Release - edicated ownflow - 1st Revision FUE NOx 97 97-98% FUE 92-92% FUE N - Natural Gas 96 96% FUE 80-80% FUE X - Low NOx Gas Valve abinet Width M - Modulating H - onvertible Two- Stage - 14" - 21" V - Two Stage S - Single Stage - 17½" - 24½" Motor - Variable Speed EM / omfortnet Maximum E - Multi- Speed EM S - Single Speed 2-800 3-1200 MTU/h 4-1600 040-40,000 TU/h 100-100,000 TU/h 5-2000 060-60,000 TU/h 120-120,000 TU/h 080-80,000 TU/h 140-140,000 TU/h 2 www.daikincomfort.com SS-M80V

Product Specifications M80V 0603* M80V 0604* M80V 0803* M80V 0804* M80V 0805* M80V 0805* M80V 1005* Heating apacity High Fire Input (TU/h)¹ 60,000 60,000 80,000 80,000 80,000 80,000 100,000 High Fire Output (TU/h)¹ (below) Natural Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000 LP Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000 Low Fire Input (TU/h)¹ 42,000 42,000 56,000 56,000 56,000 56,000 70,000 Low Fire Output (TU/h)1 (below) Natural Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000 LP Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000 FUE 2 80 80 80 80 80 80 80 vailable @ 0.5 ESP 1.5-3.0 1.5-4.0 1.5-3.0 3.0-4.0 2.0-5.0 2.5-5.0 2.0-5.0 Temperature Range ( F) 15-45 / 15-45 20-50 / 20-50 30-60 / 35-65 25-55 / 20-50 20-50 / 20-50 20-50 / 30-60 25-55 / 25-55 irculator lower Size ( x W) 10 x 8 10 x 8 10 x 8 11" x 10" 10 x 10 11" x 10" 10 x 10 Horsepower - RPM ¾ ¾ 1/2 1/2 ¾ 3/4 ¾ Speed Variable Variable Variable Variable Variable Variable Variable Vent iameter 3 4 4 4 4 4 4 4 No. of urners 3 3 4 4 4 4 4 Electrical ata Min. ircuit mpacity 4 7.75 10.6 7.75 7.75 10.6 10.6 10.6 Max. Overcurrent evice (amps) 5 15 15 15 15 15 15 15 Ship Weight (lbs) 105 107 110 118 121 129 124 ¹ Natural Gas TU/h; for altitudes above from 0 to 4,500 above sea level, reduce input rating 4% for each 1,000 above 4,500 altitude. Low-fire rate is 70% of high-fire rate. ² OE FUE based upon Isolated ombustion System (IS) ³ Minimum ircuit mpacity = (1.25 x irculator lower mps) + I lower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁴ Maximum Overcurrent Protection evice refers to maximum recommended fuse or circuit breaker size. May use fuses or HR-type circuit breakers of the same size as noted. Notes ll furnaces are manufactured for use on 115 V, 60 Hz, single-phase electrical supply. Gas Service onnection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. SS-M80V www.daikincomfort.com 3

Product Specifications 80V 0603X 80V 0803X 80V 0805X 80V 1005X Heating apacity High Fire Input (TU/h)¹ 60,000 80,000 80,000 100,000 High Fire Output (TU/h)¹ (below) Natural Gas 48,000 64,000 64,000 80,000 LP Gas 48,000 64,000 64,000 80,000 Low Fire Input (TU/h)¹ 42,000 56,000 56,000 70,000 Low Fire Output (TU/h)1 (below) Natural Gas 33,600 44,800 44,800 56,000 LP Gas 33,600 44,800 44,800 56,000 FUE 2 80 80 80 80 vailable @ 0.5 ESP 1.5-3.0 1.5-3.0 2.0-5.0 2.0-5.0 Temperature Range ( F) 25-55 / 40-70 30-60 / 30-60 25-55 / 30-60 20-50 / 25-55 irculator lower Size ( x W) 10" x 8" 10" x 8" 10" x 10" 10" x 10" Horsepower - RPM ¾ ½ ¾ ¾ Speed Variable Variable Variable Variable Vent iameter 3 4" 4" 4" 4" No. of urners 3 4 4 5 Electrical ata Min. ircuit mpacity 4 7.75 7.75 10.6 10.6 Max. Overcurrent evice (amps) 5 15 15 15 15 Ship Weight (lbs) 105 109 125 129 ¹ Natural Gas TU/h; for altitudes above from 0 to 4,500 above sea level, reduce input rating 4% for each 1,000 above 4,500 altitude. Low-fire rate is 70% of high-fire rate. ² OE FUE based upon Isolated ombustion System (IS) ³ Minimum ircuit mpacity = (1.25 x irculator lower mps) + I lower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁴ Maximum Overcurrent Protection evice refers to maximum recommended fuse or circuit breaker size. May use fuses or HR-type circuit breakers of the same size as noted. Notes ll furnaces are manufactured for use on 115 V, 60 Hz, single-phase electrical supply. Gas Service onnection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. 4 www.daikincomfort.com SS-M80V

M80V imensions lternate Gas Inlet 1¾ 1 19½ 27 33 lt. Gas Inlet High-Voltage Inlet 20 23 lt. High Voltage Low-Voltage Inlet 13¼ lt. Low Voltage 15 28 23 imensions Widths Model W H M80V0603* 17½" 28" 33⅜" 17½" 16" M80V0604* 17½" 28" 33⅜" 17½" 16" M80V0803* 17½" 28" 33⅜" 17½" 16" M80V0804* 21" 28" 33⅜" 21" 19½" M80V0805* 21" 28" 33⅜" 21" 19½" M80V1005* 21" 28" 33⅜" 21" 19½" M80V1005* 24½" 28" 33⅜" 24½" 23" Minimum learances to ombustible Materials Sides Rear Front ¹ SW Vent ² Top 1 0 3 6 1 1 pproved for line contact in the horizontal position. ¹ 24" clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements. SS-M80V www.daikincomfort.com 5

80V imensions 28 19 ⅝ High-Voltage Electrical Low-Voltage Electrical Gas Inlet 33 ⅜ 18 ⅜ 11 ⅜ imensions Widths Model W H 80V0603X 17½" 28" 33⅜" 17½" 16" 80V0803X 17½" 28" 33⅜" 17½" 16" 80V0805X 21" 28" 33⅜" 21" 19½" 80V1005X 21" 28" 33⅜" 21" 19½" Minimum learances to ombustible Materials Sides Rear Front ottom SW Vent 1 0 3 6 1 1 = If placed on combustible floor, the floor MUST be wood ONLY. Notes: For servicing or cleaning, a 24 front clearance is recommended. Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Refer to the appropriate US and anadian codes: In the US: the National Fuel Gas ode NFP 54 / NSI Z223.1 In anada: the anada National Standard of anada, N/S 149.1 and N/S 142.2 Top 6 www.daikincomfort.com SS-M80V

M80V irflow ata M80V0603** ooling Speeds M80V0603** (@.1 -.5 w.c. ESP; Range: 15-45 F) Minus 10% 628 421 Minus 10% 911 662 N Minus 5% 663 445 Minus 5% 961 698 N Normal 698 468 Normal 1,012 735 44 Plus 5% 732 491 Plus 5% 1,063 772 42 Plus 10% 768 515 Plus 10% 1,113 809 40 Minus 10% 762 525 Minus 10% 988 724 45 Minus 5% 804 555 Minus 5% 1,043 764 43 Normal 847 584 Normal 1,098 804 40 Plus 5% 889 613 Plus 5% 1,153 844 39 Plus 10% 932 642 Plus 10% 1,208 884 37 Minus 10% 930 664 Minus 10% 1,081 787 41 Minus 5% 982 701 Minus 5% 1,141 830 39 Normal 1,034 738 Normal 1,201 874 37 Plus 5% 1,086 775 Plus 5% 1,261 918 35 Plus 10% 1,137 812 Plus 10% 1,321 961 34 Minus 10% 1,128 785 Minus 10% 1,179 841 38 Minus 5% 1,190 828 Minus 5% 1,245 887 36 Normal 1,253 872 Normal 1,310 934 34 Plus 5% 1,316 915 Plus 5% 1,376 981 32 Plus 10% 1,378 959 Plus 10% 1,441 1,027 31 M80V0604** ooling Speeds M80V0604** (@.1" -.5" w.c. ESP; Range: 20-50 F) Minus 10% 540 351 Normal 600 390 Normal 1,250 875 36 Minus 10% 1,125 788 40 Minus 5% 570 371 Minus 5% 1,188 831 37 Plus 5% 630 410 Plus 5% 1,313 919 34 Plus 10% 660 429 Plus 10% 1,375 963 32 Minus 10% 720 468 Minus 10% 1,215 851 37 Minus 5% 760 494 Minus 5% 1,283 898 35 Normal 800 520 Normal 1,350 945 33 Plus 5% 840 546 Plus 5% 1,418 992 31 Plus 10% 880 572 Plus 10% 1,485 1,040 30 Minus 10% 990 644 Minus 10% 1,305 914 34 Minus 5% 1,045 679 Minus 5% 1,378 964 32 Normal 1,100 715 Normal 1,450 1,015 31 Plus 5% 1,155 751 Plus 5% 1,523 1,066 29 Plus 10% 1,210 787 Plus 10% 1,595 1,117 28 Minus 10% 1,260 819 Minus 10% 1,395 977 32 Minus 5% 1,330 865 Minus 5% 1,473 1,031 30 Normal 1,400 910 Normal 1,550 1,085 29 Plus 5% 1,470 956 Plus 5% 1,628 1,139 27 Plus 10% 1,540 1,001 Plus 10% 1,705 1,194 26 See Notes on page 10. SS-M80V www.daikincomfort.com 7

M80V irflow ata (cont.) M80V0803** ooling Speeds M80V0803** (@.1 -.5 w.c. ESP; Range 30 F - 60 F) Minus 10% 657 419 Minus 10% 911 662 N Minus 5% 694 442 Minus 5% 961 698 N Normal 730 465 Normal 1,012 735 59 Plus 5% 767 488 Plus 5% 1,063 772 56 Plus 10% 803 512 Plus 10% 1,113 809 53 Minus 10% 790 526 Minus 10% 988 724 60 Minus 5% 834 555 Minus 5% 1,043 764 57 Normal 878 584 Normal 1,098 804 54 Plus 5% 922 613 Plus 5% 1,153 844 51 Plus 10% 966 642 Plus 10% 1,208 884 49 Minus 10% 950 702 Minus 10% 1,081 787 55 Minus 5% 1,003 741 Minus 5% 1,141 830 52 Normal 1,056 780 Normal 1,201 874 49 Plus 5% 1,109 819 Plus 5% 1,261 918 47 Plus 10% 1,162 858 Plus 10% 1,321 961 45 Minus 10% 1,102 832 Minus 10% 1,179 841 50 Minus 5% 1,163 878 Minus 5% 1,245 887 48 Normal 1,224 924 Normal 1,310 934 45 Plus 5% 1,285 970 Plus 5% 1,376 981 43 Plus 10% 1,346 1,016 Plus 10% 1,441 1,027 41 M80V0804** ooling Speeds M80V0804** (@.1 -.5 w.c. ESP; Range: 25 F - 55 F) Minus 10% 771 529 Minus 10% 1,111 817 53 Minus 5% 814 559 Minus 5% 1,172 863 51 Normal 857 588 Normal 1,234 908 48 Plus 5% 900 617 Plus 5% 1,296 953 46 Plus 10% 943 647 Plus 10% 1,357 999 44 Minus 10% 946 668 Minus 10% 1,229 887 48 Minus 5% 998 705 Minus 5% 1,297 937 46 Normal 1,051 742 Normal 1,365 986 43 Plus 5% 1,104 779 Plus 5% 1,433 1,035 41 Plus 10% 1,156 816 Plus 10% 1,502 1,085 39 Minus 10% 1,156 790 Minus 10% 1,351 955 44 Minus 5% 1,220 834 Minus 5% 1,426 1,008 42 Normal 1,284 878 Normal 1,501 1,061 39 Plus 5% 1,348 922 Plus 5% 1,576 1,114 38 Plus 10% 1,412 966 Plus 10% 1,651 1,167 36 Minus 10% 1,454 944 Minus 10% 1,456 1,028 41 Minus 5% 1,535 997 Minus 5% 1,537 1,085 39 Normal 1,616 1,049 Normal 1,618 1,142 37 Plus 5% 1,697 1,101 Plus 5% 1,699 1,199 35 Plus 10% 1,778 1,154 Plus 10% 1,780 1,256 33 See Notes on page 10. 8 www.daikincomfort.com SS-M80V

M80V irflow ata (cont.) M80V0805** ooling Speeds M80V0805** (@.1" -.5" w.c. ESP; Range: 20-50 F) Minus 10% 720 468 Minus 10% 1,350 945 44 Minus 5% 760 494 Minus 5% 1,425 998 42 Normal 800 520 Normal 1,500 1,050 40 Plus 5% 840 546 Plus 5% 1,575 1,103 38 Plus 10% 880 572 Plus 10% 1,650 1,155 36 Minus 10% 990 644 Minus 10% 1,440 1,008 41 Minus 5% 1,045 679 Minus 5% 1,520 1,064 40 Normal 1,100 715 Normal 1,600 1,120 37 Plus 5% 1,155 751 Plus 5% 1,680 1,176 35 Plus 10% 1,210 787 Plus 10% 1,760 1,232 34 Minus 10% 1,260 819 Minus 10% 1,530 1,071 39 Minus 5% 1,330 865 Minus 5% 1,615 1,131 37 Normal 1,400 910 Normal 1,700 1,190 35 Plus 5% 1,470 956 Plus 5% 1,785 1,250 33 Plus 10% 1,540 1,001 Plus 10% 1,870 1,309 32 Minus 10% 1,620 1,053 Minus 10% 1,620 1,134 37 Minus 5% 1,710 1,112 Minus 5% 1,710 1,197 35 Normal 1,800 1,170 Normal 1,800 1,260 33 Plus 5% 1,890 1,229 Plus 5% 1,890 1,323 31 Plus 10% 1,980 1,287 Plus 10% 1,980 1,386 30 M80V0805** ooling Speeds M80V0805** (@.1 -.5 w.c. ESP; Range: 20-50 F) Minus 10% 747 524 Minus 10% 1,798 1,247 33 Minus 5% 789 553 Minus 5% 1,898 1,317 31 Normal 830 582 Normal 1,998 1,386 30 Plus 5% 872 611 Plus 5% 2,098 1,455 28 Plus 10% 913 640 Plus 10% 2,198 1,525 27 Minus 10% 1,025 707 Minus 10% 1,806 1,265 33 Minus 5% 1,082 747 Minus 5% 1,907 1,335 31 Normal 1,139 786 Normal 2,007 1,405 30 Plus 5% 1,196 825 Plus 5% 2,107 1,475 28 Plus 10% 1,253 865 Plus 10% 2,208 1,546 27 Minus 10% 1,405 942 Minus 10% 1,820 1,274 33 Minus 5% 1,483 995 Minus 5% 1,921 1,344 31 Normal 1,561 1,047 Normal 2,022 1,415 29 Plus 5% 1,639 1,099 Plus 5% 2,123 1,486 28 Plus 10% 1,717 1,152 Plus 10% 2,224 1,557 27 Minus 10% 1,769 1,193 Minus 10% 1,842 1,292 32 Minus 5% 1,868 1,260 Minus 5% 1,945 1,363 30 Normal 1,966 1,326 Normal 2,047 1,435 29 Plus 5% 2,064 1,392 Plus 5% 2,149 1,507 28 Plus 10% 2,163 1,459 Plus 10% 2,252 1,579 26 See Notes on page 10. SS-M80V www.daikincomfort.com 9

M80V irflow ata (cont.) M80V1005* ooling Speeds M80V1005* (@.1" -.5" w.c. ESP; Range: 25-55 F) Minus 10% 720 468 Minus 10% 1,553 1,089 48 Minus 5% 760 494 Minus 5% 1,639 1,150 45 Normal 800 520 Normal 1,725 1,210 43 Plus 5% 840 546 Plus 5% 1,811 1,271 41 Plus 10% 880 572 Plus 10% 1,898 1,331 39 Minus 10% 990 644 Minus 10% 1,575 1,103 47 Minus 5% 1,045 679 Minus 5% 1,663 1,164 45 Normal 1,100 715 Normal 1,750 1,225 42 Plus 5% 1,155 751 Plus 5% 1,838 1,286 40 Plus 10% 1,210 787 Plus 10% 1,925 1,348 38 Minus 10% 1,260 819 Minus 10% 1,598 1,121 46 Minus 5% 1,330 865 Minus 5% 1,686 1,183 44 Normal 1,400 910 Normal 1,775 1,245 42 Plus 5% 1,470 956 Plus 5% 1,864 1,307 40 Plus 10% 1,540 1,001 Plus 10% 1,953 1,370 38 Minus 10% 1,620 1,053 Minus 10% 1,620 1,134 46 Minus 5% 1,710 1,112 Minus 5% 1,710 1,197 43 Normal 1,800 1,170 Normal 1,800 1,260 41 Plus 5% 1,890 1,229 Plus 5% 1,890 1,323 39 Plus 10% 1,980 1,287 Plus 10% 1,980 1,386 37 Notes These charts are for furnaces installed at 0-4,500. t higher altitudes, a properly de-rated unit will have the same temperature rise at a particular, while the ESP at that will be lower. The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. o not operate above.5 w.c. ESP in heating mode. Propane gas installations will have a high-stage rise approximately 4 F lower than shown in the tables. Minimum Filter Sizes Model # M80V0604* M80V0805* M80V1005* Filter Size (in²) (1) 16 x 25 (Side or ottom) (1) 16 x 25 (Side or ottom) ¹ (2) 16 x 25 (Side) or (1) 20 x 25 (ottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2-16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. 10 www.daikincomfort.com SS-M80V

80V irflow ata 80V0603X* ooling Speeds Minus 10% 568 371 80V0603X* (@.1" -.5" w.c. ESP; Range: 25-55 F); NR = Not Recommended Normal 631 412 Normal 1,107 784 40 Minus 10% 996 706 45 Minus 5% 599 391 Minus 5% 1,052 745 42 Plus 5% 663 433 Plus 5% 1,162 823 38 Plus 10% 694 453 Plus 10% 1,218 862 36 Minus 10% 755 513 Minus 10% 1,078 766 41 Minus 5% 797 542 Minus 5% 1,138 808 39 Normal 839 570 Normal 1,198 851 37 Plus 5% 881 599 Plus 5% 1,258 894 35 Plus 10% 923 627 Plus 10% 1,318 936 34 Minus 10% 945 646 Minus 10% 1,184 830 38 Minus 5% 998 682 Minus 5% 1,250 876 36 Normal 1,050 718 Normal 1,316 922 34 Plus 5% 1,103 754 Plus 5% 1,382 968 32 Plus 10% 1,155 790 Plus 10% 1,448 1,014 31 Minus 10% 1,115 758 Minus 10% 1,266 865 35 Minus 5% 1,177 800 Minus 5% 1,337 913 33 Normal 1,239 842 Normal 1,407 961 32 Plus 5% 1,301 884 Plus 5% 1,477 1,009 30 Plus 10% 1,363 926 Plus 10% 1,548 1,057 29 80V0803X* ooling Speeds Minus 10% 579 381 80V0803X* (@.1" -.5" w.c. ESP; Range: 30-60 F;) NR = Not Recommended Normal 643 423 Normal 937 690 NR Minus 10% 843 621 NR Minus 5% 611 402 Minus 5% 890 656 NR Plus 5% 675 444 Plus 5% 984 725 60 Plus 10% 707 465 Plus 10% 1,031 759 57 Minus 10% 704 524 Minus 10% 940 669 NR Minus 5% 743 553 Minus 5% 993 706 60 Normal 782 582 Normal 1,045 743 57 Plus 5% 821 611 Plus 5% 1,097 780 54 Plus 10% 860 640 Plus 10% 1,149 817 52 Minus 10% 884 621 Minus 10% 1,039 726 57 Minus 5% 928 656 Minus 5% 1,097 767 54 Normal 982 690 Normal 1,155 807 51 Plus 5% 1,031 725 Plus 5% 1,213 847 49 Plus 10% 1,080 759 Plus 10% 1,270 888 47 Minus 10% 1,080 722 Minus 10% 1,127 783 53 Minus 5% 1,140 762 Minus 5% 1,191 827 50 Normal 1,200 802 Normal 1,254 870 47 Plus 5% 1,260 842 Plus 5% 1,317 914 45 Plus 10% 1,320 882 Plus 10% 1,379 957 43 See Notes on page 12. SS-M80V www.daikincomfort.com 11

80V irflow ata (cont.) 80V0805X* ooling Speeds Minus 10% 735 479 80V0805X* (@.1" -.5" w.c. ESP; Range: 30-60 F; NR = Not Recommended) Minus 10% 1,261 878 47 Minus 5% 776 505 Minus 5% 1,331 927 45 Normal 817 532 Normal 1,401 976 42 Plus 5% 858 559 Plus 5% 1,471 1,025 40 Plus 10% 899 585 Plus 10% 1,541 1,074 38 Minus 10% 1,011 659 Minus 10% 1,346 943 44 Minus 5% 1,067 695 Minus 5% 1,420 996 42 Normal 1,123 732 Normal 1,495 1,048 40 Plus 5% 1,179 769 Plus 5% 1,570 1,100 38 Plus 10% 1,235 805 Plus 10% 1,645 1,153 36 Minus 10% 1,301 848 Minus 10% 1,421 1,009 42 Minus 5% 1,373 895 Minus 5% 1,500 1,065 40 Normal 1,445 942 Normal 1,579 1,121 38 Plus 5% 1,517 989 Plus 5% 1,658 1,177 36 Plus 10% 1,590 1,036 Plus 10% 1,737 1,233 34 Minus 10% 1,675 1,077 Minus 10% 1,516 1,073 39 Minus 5% 1,768 1,137 Minus 5% 1,600 1,132 37 Normal 1,861 1,197 Normal 1,684 1,192 35 Plus 5% 1,954 1,257 Plus 5% 1,768 1,252 34 Plus 10% 2,047 1,317 Plus 10% 1,852 1,311 32 80V1005X* ooling Speeds 80V1005X* (@.1" -.5" w.c. ESP; ( Range: 20-50 F) Minus 10% 763 500 Minus 10% 1,432 1,035 NR Minus 5% 806 528 Minus 5% 1,511 1,093 49 Normal 848 556 Normal 1,591 1,150 47 Plus 5% 890 584 Plus 5% 1,671 1,208 44 Plus 10% 933 612 Plus 10% 1,750 1,265 42 Minus 10% 1,059 754 Minus 10% 1,481 1,069 50 Minus 5% 1,118 796 Minus 5% 1,564 1,129 47 Normal 1,177 838 Normal 1,646 1,188 45 Plus 5% 1,236 880 Plus 5% 1,728 1,247 43 Plus 10% 1,295 922 Plus 10% 1,811 1,307 41 Minus 10% 1,332 928 Minus 10% 1,532 1,090 48 Minus 5% 1,406 979 Minus 5% 1,617 1,150 46 Normal 1,480 1,031 Normal 1,702 1,211 44 Plus 5% 1,554 1,083 Plus 5% 1,787 1,272 41 Plus 10% 1,628 1,134 Plus 10% 1,872 1,332 40 Minus 10% 1,693 1,169 Minus 10% 1,611 1,156 46 Minus 5% 1,787 1,234 Minus 5% 1,701 1,220 44 Normal 1,881 1,299 Normal 1,790 1,284 41 Plus 5% 1,975 1,364 Plus 5% 1,880 1,348 39 Plus 10% 2,069 1,429 Plus 10% 1,969 1,412 38 Notes: These charts are for furnaces installed at 0-4,500. t higher altitudes, a properly de-rated unit will have the same temperature rise at a particular, while the ESP at that will be lower. The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. o not operate above.5 w.c. ESP in heating mode. Propane gas installations will have a high-stage rise approximately 4 lower than shown in the tables. ontinuous Fan Speeds Model Furnace Maximum ontinuous Fan Speed ¹,² 80V0603X* 1,760 530 80V0803X* 1,760 530 80V0805X* 2,000 600 80V1005X* 2,000 600 12 www.daikincomfort.com SS-M80V

Temperature Range hart 100 90 80 70 60 50 40 30 20 10 TU TU OUTPUT Output vs Vs. TEMPERTURE Temperature RISE hart HRT 600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 Formulas FORMULS TU TU/h OUTPUT Output = x x 1.08 1.08 x x RISE TU OUTPUT RISE = TU/H Output = 1.08 x 1.08 30 40 50 60 70 80 90 100 110 120 130 140 150 OUTPUT Output TU/h TU/HR x 1,000 x 1000 TEMPERTURE Temperature RISE SS-M80V www.daikincomfort.com 13

2 1 EHUM Wiring iagram NOTES: 2 1 EM MTR HRNESS K R R GY K 0140F02299- HOT SURFE IGNITER 2 IRUIT ONNETOR L 3 TWO STGE GS VLVE (HONEY WELL) HI PM 2 R K URNER OMPRTMENT LOWER OMPRTMENT 4 IRULTOR LOWER 2. MNUFTURER'S SPEIFIE REPLEMENT PRTS MUST E USE EN SERVIING. 3. IF NY OF THE ORIGINL WIRE S SUPPLIE WITH THE FURNE MUST E REPLE, IT MUST E REPLE WITH WIRING MTERIL HVING TEMPERTURE RTING OF $. USE OPPER ONUTORS ONLY. GN 24V HUM. 5. TO RELL THE LST 6 FULTS, MOST REENT TO LEST REENT, EPRESS SWITH FOR MORE THN 2 SEONS ILE IN STNY (NO THERMOSTT INPUTS) 6. HUMIIFIER INSTLLTION OPTIONS: USE HUM TERMINL TO RUN HUMIIFIER URING HET LL (OMMUNITING OR LEGY MOES). USE HUM-IN N HUM-OUT TERMINLS TO RUN HUMIIFIER URING HET LL ( OMMUNITING MOE OR LEGY MOE) OR INEPENENTLY FROM HET LL (OMMUNITING MOE ONLY - SETUP IS ONE WITHIN OMMUNITING THERMOSTT) 1 3 2 5 4 3 2 1 YL PU GN INUE RFT LOWER K YL R L K INUTOR OIL (ON SOME MOELS) YL R K MNUL RESET ROLLOUT LIMIT ONTROLS 1 LOW FIRE PRESSURE PU SWITH 3 1 I LOWER TWO-STGE PRESSURE L K GR PK SWITH SSEMLY YL 4. UNIT MUST E PERMNENTLY GROUNE N ONFORM TO N.E.. N LOL OES. R 1. SET HET NTIIPTOR ON ROOM THERMOSTT T 0.7 MPS. T LEST 105 2 24 V 3 NO HIGH FIRE PRESSURE SWITH UTO RESET PRIMRY LIMIT ONTROL PU HET OFF LY NO PU R OLOR OES: PK PINK R ROWN ITE L LUE GY GRY R RE YL YELLOW OR ORNGE PU PURPLE GN GREEN K LK HSSIS GROUN OR K 24 V 115 V K WRNING: ISONNET POWER EFORE SERVIING. WIRING TO UNIT MUST E PROPERLY POLRIZE N GROUNE. INTEGRTE ONTROL MOULE K JUNTION OX YL UTO RESET UXILIRY LIMIT ONTROL (TWO ON SOME MOELS) 40 V TRNSFORMER FLME SENSOR GN LOWER OMPRTMENT OOR SWITH (OPEN EN OOR OPEN) 24V THERMOSTT ONNETIONS 24V HUM. TO R LINE TO MIRO LOW VOLTGE (24V) HI VOLTGE (115V) HI VOLTGE FIEL HUM-OUT TO +V GN (4) + V (1) RX (2) TX (3) UX INTEGRTE ONTROL MOULE TERMINL INTERNL TO INTEGRTE ONTROL PLUG ONNETION PS1 (2) HUMIIFIER GN FLME SENSOR 115 V MVH (14) INOOR IR IRULTOR LWR HOT SURFE IGNITER WRNING:ISONNET POWER EFORE SERVIING. WIRING TO UNIT MUST E PROPERLY POLRIZE N GROUNE. TO 115V/ 1Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION EVIE R Y1 W1 W2 Y2 G O ISONNET OOR SWITH LINE LOW VOLTGE FIEL JUNTION INUTOR OIL (ON SOME MOELS) FUSE 3 TO MIRO HUM E IGN FS IN HI IN LO TH (4) PSO (7) HIGH FIRE PRESS. SWTIH MV (8) JUNTION OX HUMIIFIER ELETRONI IR LENER I LWR 24V HUM. NO N GN INOOR IR IRULTOR LWR NEUTRL 40 V TRNSFORMER 24 V UTO RESET UXILIRY LIMIT UTO RESET PRIMRY ONTROLS (TWO ON SOME MOELS) LIMIT ONTROL HLO (10) PS2 (12) HLI (1) MVL (13) GN (5) TR (11) TO GN 115 V/ 1 Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION EVIE L L NO N SWITH (TEMP.) IGNITER NEUTRL NEUTRL OVERURRENT PROT. EVIE ISONNET LOW FIRE PRESS. SWITH MNUL RESET ROLLOUT LIMIT ONTROLS EQUIPMENT GN FIEL GN FIEL SPLIE SWITH (PRESS.) GN NEUTRL NEUTRL NEUTRL PM HI GS VLVE INTEGRTE ONTROL MOULE L R R YL R YL R 4 1 FUSE 14 11 5 2 LINE 15 12 9 6 TRIM % HET F EHUM ENLE TRIM ENLE TWO-STGE INTEGRTE 5 IRUIT ONNETOR 4 IRUIT MOTOR ONTROL ONNETOR MOULE IP SWITHES HUM E 13 10 7 HUM- IN HUM- OUT 8 K L YL 3 NEUTRL Y2 Y1 W1 G R OOL PRFL FS OR GN SEE NOTE 5 OOL F ONT FN T-STT W2 24 V THERMOSTT ONNETIONS 5 4 3 2 1 4 3 2 1 IGNOSTI LE'S EHUM O PU K R L HUM-IN SEE NOTE 6 HUMIIFIER Wiring is subject to change. lways refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: isconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 14 www.daikincomfort.com SS-M80V

ccessories Model escription LPM-06 LP onversion Kit (Springs & Orifice) ¹ FE18-60 Fossil Fuel Kit (must be used in a dual-fuel application with a compatible thermostat) SS Electronic ir leaners (sizes = -10, -11, -12 or -18) MU Media ir leaners (sizes = 1620, 2020, 1625 or 2025) ¹ White-Rodgers and Honeywell valves SS-M80V www.daikincomfort.com 15

Notes Our continuing commitment to quality products may mean a change in specifications without notice. 2017 Houston, Texas Printed in the US. 16 www.daikincomfort.com SS-M80V