STANDARDS FOR COMPRESSED GAS TESTING

Similar documents
DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS

CTG Certification Protocol -- Version 3.0 SUMMARY

SEMI E is due for its Five Year Review. This process is required by the SEMI Regulations to ensure that the standard is still valid.

M-06 Nitrogen Generator (Nitrogen Making Machine)

PENETRATION OF N95 FILTERING- FACEPIECE RESPIRATORS BY CHARGED AND CHARGE- NEUTRALIZED NANOPARTICLES

Technical Information

TECHNICAL INFORMATION

PERFORM Operating Document

SILICA EXPOSURE MEASUREMENT IN REAL-TIME FOR CONSTRUCTION

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

SEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

OPERATION MANUAL NTF-15

Model Series 62 Constant Differential Relay

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

MICRO-BUBBLE TRACER PARTICLES FOR PLANAR AND VOLUMETRIC PIV

PERFORM Operating Document

IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS

FACT SHEET 1. Compressed Air System Selection and Efficient Production. How to save energy, reduce costs and help the environment

MASS CONCENTRATION COMPARISON BETWEEN THE DUSTTRAK DRX AEROSOL MONITOR AND TEOM

Mass Flowmeters. Mass Flowmeters for Gases

Constant Pressure Inlet (CCN) Operator Manual

OPERATION MANUAL NTF-60 Plus

Discussion and guidance on the definition and qualification of porous loads

Note: Additions are indicated by underline and deletions are indicated by strikethrough

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Potter Nitrogen Generators

Compressed Air - Food/Bev. Presented By: Adam Zimmerman

CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 2: 2018

Model Series 63DL Differential Type Flow Controller

OPERATING INSTRUCTIONS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

VIC offers a variety of Calibrated Gas Leaks

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Columbus Instruments

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

In summary, the ISPE comments suggest the following additional improvements to the modified Annex 1 document:

Niltox Breathing Air Purifier Range

Pressure Regulators. Operating Instructions. Instrumentation

AMENDMENTS TO THE IMSBC CODE AND SUPPLEMENTS

Int r oduct ion t o Int egr it y Tes t ing Theor y

Breathable Compressed Air

Model PDT Dewpoint Transmitter

SEMASPEC Test Method for Determination of Cycle Life of Automatic Valves for Gas Distribution System Components

TECHNICAL INFORMATION

CORRECTING FOR HUMIDITY EFFECTS ON TSI GENERAL PURPOSE FLOWMETERS

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

MATHESON s LaserPro Gases and Gas Delivery Equipment

Permission granted to reproduce for educational use only.

SULLAIR SX Filtration Series ,000 scfm

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

AMT-Ex Dewpoint Transmitter

ANSI / ASSE Z88.2 American National Standard Practices for Respiratory Protection (1992 rev. versus 2015 rev.)

NGN Series nitrogen generator

Vibration isolation system 1VIS10W. User manual

Title: Standard Operating Procedure for The Tapered Element Oscillating Microbalance (TEOM)

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

USE OF RESIDUAL PRESSURE VALVES

Nitrogen Generation Systems

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Ontario ENGINEERING STANDARD SPECIFICATION 1.0 PURPOSE

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

Related Products: Auto Drain Valve. Model/Specifications. Model

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Protocol Gas Verification For Compressed Gas Cylinders Containing Either SO 2, NO or CO. Quality Assurance Plan/Standard Operating Procedure

T208VR Series Tank Blanketing Vacuum Regulator

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

THE USE OF Z FACTORS IN GRAVIMETRIC VOLUME MEASUREMENTS

Deltaflux Control Valve

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Gas Control Systems. Product overview

AIRLINE-SERIES HELMET AIR FILTER

Gas Control Systems. Product overview

PRODUCT NUMBER: Rd40 Aluminium Canister HgP3

Calibration and Switching Module

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Part 4 Machinery and systems Chapter 6 Piping systems, pumps and compressors

THE GUIDE TO MEMBRANE NITROGEN GENERATORS

Types ACE95 and ACE95Sr Tank Blanketing Valves

Detection of Micro-organisms in Compressed Gases

EMISSION SURVEY FOR SONAE NOVOBORD: WHITE RIVER. Report No. 565/12 FR.1. March 2013 C & M CONSULTING ENGINEERS PO BOX LYNNWOOD RIDGE 0040

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Type ACE95jr Tank Blanketing Valve

ISO INTERNATIONAL STANDARD

Series IRV1000/2000/3000

Transcription:

STANDARDS FOR COMPRESSED GAS TESTING APPLICATION NOTE HPD-002 (US) Introduction This publication provides excerpts from some of the many guidelines and standards that pertain to compressed gases in cleanrooms. The intent of the publication is to provide owners, engineers, and consultants an overview of the standards and guidelines that pertain to the design and operation of compressed gases in today s cleanrooms. The information provided is arranged by topic. Effort has been made to present the statements that best summarize the topics as they pertain to contamination levels and testing. The excerpts, in most cases, are worded as they appear in the standard or guideline. However, in some instances may be out of context. Please review the actual guideline or standard for more detailed information and to make the best interpretation of each statement. Topic Acceptable Levels of Contamination a ISO 8573-1:2010 Compressed air Part 1: Contaminants and purity 5.2 Particle Classes Table 1 Compressed air purity for particles When it is determined that there are particles with a size greater than 5 µm, then the classification of 1 to 5 cannot be applied. Maximum number of particles per cubic meter as a function of particle size, d b Class a 0.1 < d 0.5 < d 0.5 µm 1.0 µm 1.0 < d 5.0 µm 0 As specified by the user and more stringent than Class 1 1 20,000 400 10 2 400,000 6,000 100 3 90,000 1,000 4 10,000 5 100,000 Class Mass concentration b C p Mg/m 3 6 c 0 < C p 5 7 c 5 < C p 10 X C p >10 TSI and the TSI logo are registered trademarks of TSI Incorporated.

Acceptable Levels of Contamination (cont.) a To qualify for a class designation, each size range and particle number within a class shall be met. b At reference conditions; see Clause 4. c See A.3.2.2. ISO 8573-1:2010. Compressed air Part 1: Contaminants and purity Annex A A.2 Special applications This part of ISO 8573 might not be suitable to fully define the requirements of special applications. It can be the case that, for applications such as breathing air, medical air, food and beverage, it is required to consider controlling other contaminants not identified in a classification or not included as a contaminant, to fully specify that requirement. It can be necessary to consult other sources of information, such as a pharmacopoeia, breathing air specifications and cleanroom standards, before an air purity specification can be established. In addition, national in-use requirements can also stipulate regular testing for applications such as breathing air supplies. ISO 8573-1:2010. Compressed air Part 1: Contaminants and purity Annex A A.3.2.2 Particle 6 and 7 Industrial tools and pneumatic-fluid power-operated machines have traditionally been supplied by general purpose filters with a notional particle size rating of 5 µm (class 6) and 40 µm (class 7) US Food and Drug Administration Guidance for Industry Sterile Drug Products Produced by Aseptic Processing Current Good Manufacturing Practice (2004) IV. Buildings and facilities D. Air Filtration 1. Membrane A compressed gas should be of appropriate purity (e.g., free from oil) and its microbiological and particle quality after filtration should be equal to or better than that of the air in the environment into which the gas is introduced. Compressed gases such as air, nitrogen, and carbon dioxide are often used in cleanrooms and are frequently employed in purging or overlaying. -2-

Acceptable Levels of Contamination (cont.) Designation SEMI E49.8-1103:2003 Guide for High Purity and Ultrahigh Purity Gas Distribution Systems in Semiconductor Manufacturing Equipment Table 2 Summary of Requirements for High Purity and Ultrahigh Purity Components and Sub-Assemblies Description Static Flow Particulate Contribution (valves, regulators, flow controllers) Test procedures per SEMI F70 High Purity Value Particles 0.1 µm 0.7 ( 20) Particles 0.02 µm 2.6 ( 75) Cycle Life (valves, regulators and MFCs) sample at least four and no more than 10 components using a 90% confidence interval and exponential hazard function: Manual valves MTTF of 25 K cycles Pneumatic valves, regulators and MFCs MTTF of 500 K cycles Ultrahigh Purity Value 0.18 ( 5) 0.71 ( 20) Units Ptc/L (ptc/ft 3 ) Ptc/L (ptc/ft 3 ) Following cycling, components must meet the particulate contribution requirements of this table and the leak rate requirements in Sections 6.2, 7.2 and 7.3. ISO 8573-1:2010. Compressed air Part 1: Contaminants and purity 6. Designation 6.1 Designation principle The designation principle of the purity class of compressed air at the specified measuring point shall include the following information in the order given and separated by a colon: ISO 8573-1:2010 [A:B:C] Where A is the purity class for particles; see Table 1 B is the purity class for humidity and liquid water; see Table 2 C is the purity class for oil; see Table 3 6.2 Unspecified designation When a class for any particular contaminant A, B or C is not specified, the designation shall be replaced by a hyphen. In the example given below, there is no humidity or liquid water classification. ISO 8573-1:2010:2010 [A:-:C] 6.3 Class X designation When the contamination level falls within class X, then the highest concentration of the contaminant shall be given in round brackets. In the example given below, the concentration of liquid water, C w, is 15 g/m 3. ISO 8573-1:2010:2010 [A:X(15):C] -3-

Instrumentation Full-flow sampling 6 Selection of method The method to be selected depends on the concentration range and the sizes of particles in the compressed air. For choosing the method most suitable for the concentration range and sizes of particles estimated to be present in the sample, see Table 1. The applicability of particular measurement equipment to a method should be verified with the equipment manufacturer. Table 3 Compressed air purity for oil Applicable concentration range Method particles/m 3 Laser particle 0 to10 counter 5 Condensation 10 nucleus counter 2 to 10 8 Differential mobility Not applicable analyzer Scanning mobility 10 particle sizer 2 to 10 8 Sampling on membrane surface 0 to 10 in conjunction with 3 a microscope Applicable solid particle diameter d µm 0,10 0,5 1 5 7 Sampling techniques 7.1 General Solid particles can be measured at atmospheric pressure or under ambient pressure conditions depending on equipment used. Measurement can be carried out at partial or full flow. a) Full flow sampling of total airflow b) Partial flow sample taken from a percentage of the airflow If the particle diameter is greater than 1 µm, then sampling shall be isokinetic. 7.2 Full-flow sampling 7.2.1 General For full-flow sampling using physical methods, if the particle diameter is greater than 0.5 µm, a gridded membrane shall be used Particular attention shall be paid to the cleanliness of the test equipment, and other precautions shall be taken, e.g. valve purging and stabilization to constant test conditions 7.2.2 Test Equipment Full-flow sampling shall be carried out by gridded membrane only. -4-

Isokinetic sampling High Pressure Diffuser Design Qualification Manufacturing Qualification 7.3 Isokinetic sampling 7.3.1 General Accurate isokinetic sampling is not critical for small particles (less than 1 µm), although approximate isokinetic conditions are advisable 7.4 Reducing system pressure before measurement If the system pressure is reduced before the measurement, the reduction method shall not influence the resulting particle count and particle distribution. SEMI 49.6-1103:2003 Guide for Subsystem Assembly and Testing Procedures Stainless Steel Systems 9 Assembly Qualification and Quality Assurance 9.3 Design Qualification Gas delivery system design performance should be qualified in terms of two parameters: particulate generation and contaminant spike recovery. This testing should be performed on the initial gas delivery system prototype and on any design revision system which significantly impacts the component selection or system configuration. 9.3.1 Particulate Generation Static and dynamic particle testing should be performed in accordance with SEMI F70 with a flow rate of at least 3 times the maximum process flow rate at the recommended supply pressure, except during mass flow controller testing when test flow rates should be between 0% and 100% of the MFC (Mass Flow Controller) value. Testing should be performed on all flow paths that differ significantly in components or configuration. Dynamic test protocols should be as follows: Each valve in the test flow path should be cycled individually. Starting with the valve furthest upstream, cycle each valve once every 20 seconds. MFC valves should be cycled from 0% to 100%. SEMI 49.6-1103:2003 Guide for Subsystem Assembly and Testing Procedures Stainless Steel Systems 9 Assembly Qualification and Quality Assurance 9.4 Manufacturing Qualification Manufacturing qualification tests should be performed to verify the manufacturing and quality control procedures followed in the manufacturing of the gas delivery system. As the configuration of gas systems varies greatly from process to process, no specification should be given here other than to state that static and dynamic particle testing, moisture level, oxygen level and hydrocarbon testing should be performed to show that the gas delivery system will meet the purity levels required. 9.5 Certification Certification for gas delivery systems should include: leak rate certification, particle counts with specified flow rates at specified pressures and flow schematic indicating which flow paths were tested and which components were cycled -5-

References SEMI 49.6-1103:2003 Guide for Subsystem Assembly and Testing Procedures Stainless Steel Systems. 2003 ISO 8573-1:2010 Compressed air Part 1: Contaminants and Purity Classes. 2010 ISO 8573-4:2001 Compressed air Part 4: Test methods for solid particle. 2001 US Food and Drug Administration Guidance for Industry. Sterile Drug Products Produced by Aseptic Processing Current Good Manufacturing Practice. 2004 TSI Incorporated Visit our website www.tsi.com for more information. USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 HPD-002 Rev. A (1/13/2017) US 2017 TSI Incorporated Printed in U.S.A.