TECHNICAL CHARACTERISTIC CT 071

Similar documents
Aneroid Sphygmomanometer. Use, Care, & Maintenance

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

STANDARD OPERATING PROCEDURE ARTSANA MERCURY SPHYGMOMANOMETER

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

USE, CARE & MAINTENANCE DIAGNOSTIX TM 972 MERCURIAL BLOOD PRESSURE INSTRUMENT

ADC. Sphygmomanometer Accessories. Directions for Use, Care, & Maintenance AMERICAN DIAGNOSTIC CORPORATION

DIAGNOSTIX TM 922 MERCURIAL BLOOD PRESSURE INSTRUMENT. Use, Care, & Maintenance

ERKA Profi impact-resistant based on internationally recognised standards such as ANSI/ AAMI SP 10.

CELEBRATING 150 YEARS Accuracy starts in the name SPHYGMOMANOMETERS

Klinik ERKAmeter base model with rail holder, available separately.

Blood Pressure Monitor

ESTABLISHED OVER 150 YEARS FROM Accuracy starts in the name SPHYGMOMANOMETERS

Tourniquet Systems Pressure Infusion

ERKA Vario base model with rail holder, available separately.

Diagnostix TM Aneroids

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

SUPERB RAPID YOUR CHOICE FOR EVERYDAY USE

Instruction Manual for Configura Cushionair Portable Pump

Instructions for use Compressed air injector with water trap

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

BLOOD PRESSURE SENSOR 0377i

Semi-Automatic Blood Pressure Monitor with Memory

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

BLOOD PRESSURE SENSOR BT17i USER S GUIDE

Med Aire Alternating Pressure Pump and Pad System

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

VER: A00. Model No:BA2010

Installation, Operation and Maintenance Manual for Back Pressure Regulator

MyControl Bathing System Signature Series

WIKA INSTRUMENT CORPORATION

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

TOURNIQUET SYSTEMS & PRESSURE INFUSION

INSTRUCTIONS. Manual Home Blood Pressure Monitor MODEL Stethoscope Chestpiece. Cuff. Bulb

Contents. Safety Notice. Wrist Type

Model 130M Pneumatic Controller

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG

TOURNIQUET SYSTEMS & PRESSURE INFUSION

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Measurement of Low GAS & Liquid Flows

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Sports Wrist Digital Blood Pressure Monitor Item #

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

LOCK UP VALVES YT-400/405/430/435 SERIES

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Budget Range Operators Handbook

LIGHTWEIGHT TRIWALKER OWNER S HANDBOOK

Pressure Relief Valve DHV 718

B.C.D. Buoyancy Compensator Device User Manual

Decontamination Procedures for Gilson Pipettes

REF REF REF

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Vibration isolation system 1VIS10W. User manual

Declaration of Equivalence Form

User manual STARLOCK. Careways International - Innovation Quality Performance

Purge Star & Ring Purge Systems

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

MODEL CALIBRATION GAS DELIVERY SYSTEM

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Maintenance and Calibration

Blood Pressure Cuffs

80 Litre Suction Oil Drainer

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Horizontal Bladder Tanks

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

INSTRUCTIONS FOR USE BODY ARMOR PRO TERM

Operating manual for Material pressure tanks Vol./1 and Vol./2

INSTALLATION AND OPERATION INSTRUCTIONS

FRONT DERAILLEUR 10/11x3

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Other languages available on our website:

Vertical Bladder Tanks

12S 1st Stage. -Maintenance Procedure-

SANP ACTING RELAYS YT-520/525/530 SERIES

Gas Pressure Regulator HON 502

INTRODUCING SCHEDULE. Lawful owner Stefano Gollini. The paragraphs preceded by this symbol, if not respected can lead to damages to the machine

OPERATING INSTRUCTIONS

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Cobi Positioning Cushions

OPERATION MANUAL obl1 OPERATION MANUAL

CSA Sample Draw Aspirator Adapter Operator s Manual

Circulation and Respiration: Vital Signs Student Version

30T A/Manual Hydraulic Shop Press

GALISO SOAP OPTION FOR PCT-ADW-D

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

Transcription:

MADE IN FRANCE Regulatory information CE Marking Index of classification Notified body CE 0459 Im G-MED PHTALATES LATEX Sphygmomanometer hand-held type with aneroid membrane, very light. This precision manometer graduated from 0 to 300 mmhg is fixed on an anodized aluminum valve, equipped with a decompression knob. Reading of measured values is facilitated by the size of the dial. Accuracy of ± 3 mm guaranteed over the entire measuring range. This flexible and robust design and can be cleaned by machine and decontaminated by immersion after: * Remove the Soft Cuff bladder from cuff. * Seal the connection pipes f cuffs. - Reliability: an INDEX and a Min Max range allow to quickly validate whether the cuff or the cuff is adapted to the patient's limb. - The indication "artery" carried on the cuff makes it possible to perfectly position this one, the pocket being automatically centered on the passage of the artery. - Security : to fight against nosocomial infections, this fabric underwent an antimicrobial treatment. 1 - Device identification Sphygmomanometer with Soft Cuff Sphygmomanometer with Easy Cuff Page 1 / 9

2 References Reference sphygmomanometer with cuff : Designation Ref with Soft Cuff Ref with Easy Cuff Manometer A10370 New born TS50001 TI50001 Child TS50002 TI50002 Small adult TS50003 TI50003 Adult TS50004 TI50004 Adult large TS50005 TI50005 Lower limb cuff adult TS50006 TI50006 Reference and size of Soft Cuff : Circumference in Dimensions in mm Reference Designation Tube cm Tube color Min Max A B C D E BT101 New born 1 6 12 173 55 95 40 43 GREY BT102 Child 1 11 22 348 97 180 80 85 GREY BT103 Small adult 1 16 28 458 130 230 110 120 GREY BT104 Adult 1 26 33 528 149 260 129 70 GREY BT105 Adult large 1 33 41 633 174 330 150 75 GREY CT104 Lower limb cuff adult 1 39 55 828 214 440 190 145 GREY Page 2 / 9

A B Position indication index Product Brand C D E F G H I J K L M N Number of batch Name and product number Range of the product Original product marking Validity range of product use Indication for placement of the artery Machine wash at 60 C Do not use bleacher Do not iron Latex free Can be dry cleaned using any solvent Indication of the number of tube Page 3 / 9

Reference and size f : Circumference in Dimensions in mm Reference Designation Tube cm Tube color Min Max A B C D E BM101 New born 1 6 12 170 40 95 47,5 43 WHITE BM102 Child 1 11 22 338 80 180 90 85 PINK BM103 Small adult 1 16 28 423 110 230 115 120 PARMA BM104 Adult 1 26 33 516 129 256 129 70 BLUE SKY BM105 Adult large 1 33 41 616,8 150 330 165 80 TURQUOISE CM104 Lower limb cuff adult 1 39 55 816,5 190 440 220 160 PURPLE Page 4 / 9

A Indication of the position of the index B Product Brand C Name and product number D E F G H I J K Original product marking Range of product use Date of manufacture See operating instructions Latex free Manufacturing Lot Number Validity range of product use Indication for placement of the artery Page 5 / 9

3 - Use of the device Operating instructions Select a cuff adapted to the morphology of the patient. The size and range of use are indicated on the cuff. Position the center of the bladder pocket represented by a heart on the axis of the brachial artery. Roll the cuff around the limb. Once the cuff positioned and ready to use, the INDEX must be between the Min and Max (axis of the heart). If INDEX exceeds the Max index located at the axis of the heart, replace the cuff by the model of the larger size. If INDEX exceeds Min index located at the tip of the range, replace the cuff by the model of smaller size. When the cuff and INDEX are positioned correctly the procedure for measuring blood pressure can begin. Correctly roll the cuff around the limb and ensure its continuation with the fastening system provided. Place the tips of the lyre of the stethoscope in your ears, the microphone in the listening position, just below the cuff, on the passage of the artery. Ensure that the vent screw of the pear is in the closed position 30 and to inflate or 40 mmhg above the estimated pressure. Blood no longer circulates at the microphone, no sound is heard with a stethoscope. Loosen the vent screw the bulb to slowly reduce the inflation pressure and allow blood to flow again, the first beats are perceptible stethoscope. Read this pressure gauge reading now, this value corresponds to the maximum pressure or systolic pressure. Continue decompression beats levied stethoscope amplify then fade to become inaudible. Read this moment the pressure indicated, this reading corresponds to the minimum pressure or diastolic pressure. Unscrew the knob further relief to completely purge the remaining air in the bladder. Remove the cuff. Page 6 / 9

4 - Identification and characteristics of differents subsets Identifier Reference Denomination Characteristics A Soft Cuff Arm cuff Velcro + bladder Fabric with coating and antibacterial treatment and PU coated fabric bladdert A Easy Cuff Monobloc cuff Welded PU coated fabric + antibacterial treatment B A10362 Glass Polycarbonate C A10363 Upper protector Polyurethane D A10364 Casing Aluminium E A10365 Body Aluminium F A10226 Bulb Phtalates - free PVC G A10366 Lower cover Polyurethane H A10367 Mechanism 0-300 mmhg Brass I A10368 Valve + filter + washer + circlips J A10372 Intermediate protector EPDM Page 7 / 9

A- Soft Cuff A- Easy Cuff 5 Cleaning and disinfection 1/Cleaning of manometer : Spray disinfecting solutions. do not use detergent, do not immerse. 2) Cleaning of arm cuff by dry cleaning : A) Spray a foam detergent, disinfectant, bactericidal on the arm cuff, taking care to distribute the product well on the surface. B) Leave 15 minutes. C) Do not rinse. D) Product recommended: Surface Safe / Anios. 3) Cleaning of arm cuff by immersion (after removing the bladder) : A) Remove the arm cuff bag B) Clean the arm cuff with water or with washing machine. Washing machine at 40 (60 being the maximum), without a spin cycle. The number of washing machine and the washing temperature decreases the life of the cuff. C) Immerse the arm cuff assembly in a decontaminating solution. D) Immersion time : 15 minutes. Rinse thoroughly with water, renewing the dipping bath after each use. Product recommended : Aniosyme DD1 manufactured by Anios Page 8 / 9

6 Maintenance : Control calibration every 12 months for the manometer. 7 Packaging Reference Packaging unit TS50001 TI50001 1 TS50002 TI50002 1 TS50003 TI50003 1 TS50004 TI50004 1 TS50005 TI50005 1 TS50006 TI50006 1 8 Storage Type of packaging Storage area Temperature Humidity Atmospheric pressure Original packaging Ventilated area -10 to 40 c 30 to 40 % 500 to 1060 hpa 9 Warranty This warranty provides assurance for the customer who purchases a D & D product that should the product fail to function to D & D published specifications during the term of this warranty, will either replace or repair. The guarantee period is 2 (two) years from the date of purchase. The product must be used in accordance with its labeling and may not be altered or subjected to misuse, abuse, accident or improper handling. Page 9 / 9