An introduction to modern scleral lenses

Similar documents
Scleral Fitting Guide

DISCLOSURES FITTING AND TROUBLESHOOTING SCLERAL LENSES WHO S A GOOD CANDIDATE SCLERAL LENS ADVANTAGES ANDREW J. BIONDO, OD, FSLS.

FITTING AND TROUBLESHOOTING SCLERAL LENSES

Sofmed breathables XW (comfilcon A) Sofmed breathables XW premium (comfilcon A) Sofmed breathables XW toric (comfilcon A)

POLYMACON HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

Fitting Guide. Minutes-to-Fit 2.0. by SynergEyes Moving Vision Forward

Pardon the Objection (PTO) Contact Lens Clinical Case Debate (2 hours)

NormalEyes Guidelines For Successful Fitting RIGID GAS PERMEABLE SCLERAL CONTACT LENSES. Manufactured in Paragon HDS 1OO (paflufocon D)

Spherical Soft Contact Lens Fitting. J. Perrigin OPTO 6374 Spring 2017

Acknowledgments. Paragon Vision Sciences Adoption of CRT certification slide for this generic talk. Material Considerations

Rejuvenating Aftercare for Contact Lens Patients

Dr. Thomas R. Reim President, DreimLens, Inc.

EVERY TREATMENT IS A TRUE ORIGINAL

The BE Retainer System Certification Course. Supplement

LASIK Wavefront Guided idesign LASIK with IntraLase

Appendix C: Skill Stations Examination - Marking Rubric

Appendix C: Skill Stations Examination - Marking Rubric

Ophthalmology Clinical Pearls A Quick Guide To Crystalens

ARTICLE IN PRESS Contact Lens & Anterior Eye xxx (2012) xxx xxx

How images are formed in the eye

AIR OPTIX BRAND CONTACT LENSES LENS PARAMETER GUIDE November 2016

Orthokeratology. What is Orthokeratology? How does it work?

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR ORTHOKERATOLOGY. (hexafocon B)

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

PROFESSIONAL FITTING GUIDE. for the. HUBBLE Daily. Table of Contents

Rejuvenating Aftercare for Contact Lens Patients

senofilcon A Soft (hydrophilic) Contact Lenses Visibility Tinted with UV Blocker for Daily Disposable Wear

Oxygen tension under a contact lens. Kenneth A. Poise and Marianne Decker

Bulletin NEXT MEETING

Purge Star & Ring Purge Systems

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

Eye Injuries. Chapter 25

Refraction Certificate Examination. Instructions to Candidates

PRODUCT PORTFOLIO RIGID GAS PERMEABLE CONTACT LENSES SOFT CONTACT LENSES LENSCARE SOLUTIONS ACCESSORIES

Contact lenses designed to fit more of your patients

NOVEMBER Why SiHy? The many benefits of silicone hydrogel make it a preferred material for daily disposable lenses

Leadership in Fluid Management

7.9. Flash Column Chromatography Guide

Biometry tips. Marilyn Watkins-Ramdin, COMT ROUB

THE PMI ADVANCED CAPILLARY FLOW POROMETER

Soft Contact Lens Identification Guide

PROFESSIONAL FITTING AND INFORMATION GUIDE. Paragon CRT Manufactured in Paragon HDS (paflufocon B)

LENS EXCHANGE WITH IMPLANTATION OF A BITORIC INTRAOCULAR LENS IN EYES WITH SIGNIFICANT ASTIGMATISM AFTER PREVIOUS CORNEAL SURGERIES

A New Piston Gauge to Improve the Definition of High Gas Pressure and to Facilitate the Gas to Oil Transition in a Pressure Calibration Chain

BACK TO BASICS The Shotgun

Underwater Housing for Canon G7X Mark II

A life without glasses or contact lenses

Quincey Eyewear. Expanding Horizons 2017 PRESCRIPTION SWIMMING GOGGLES

SUPER BLUE INSTRUCTIONS FOR TRIMMING AND INSTALLING ORIGINAL NETS WITH STRIPES

Stephen Lash Post operative instructions- Combined Surgery (Cataract and vitrectomy)

2018 OFFICIAL INDIAN ROCK DISTICT PINEWOOD DERBY RULES & GUIDELINES

Hide and Seek. Adapted from: Activity 38 Hide and Seek Living in Water. The National Aquarium in Baltimore, 1997.

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

Sizing Pulsation Dampeners Is Critical to Effectiveness

Everything you need to know about flatteners and levelers for coil processing

Density and Stress in Plastics Mary V. McCrary

TITAN FLOW CONTROL, INC.

Columbia Taping Tools. Hydra Reach Handle. Manual

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

SPWE Series. Setup Instructions. Version 2.0

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR CONTACT LENS CORNEAL REFRACTIVE THERAPY

Discussion and guidance on the definition and qualification of porous loads

OPESAVER Super Irrigation System

Translation of the original Operating Instructions for HKS rubber compensators

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

General Accreditation Guidance. User checks and maintenance of laboratory balances

THERMALLING TECHNIQUES. Preface

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Figure 2: Principle of GPVS and ILIDS.

"EYE CARE AND SAFETY"

Surface Tension Student Handout

THE TOP 100 KEYWORDS FOR AN

Table of Contents. Introduction. Content written by: Osuagwu Levi RO, RCLP Content originally published in the Spring 2010 edition of The Eighth Line

V E J A R A N O P R O T O C O L FOR T H E M A N A G M E N T O F Q U E R A T O C O N O SURGICAL T I PS

Wooden Dummy Construction

Pythagorean Combinations for LEGO Robot Building

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR)

Operating manual Analogue refractometer

NHS Training for Physiotherapy Support Workers. Workbook 16 Gait re-education

Operating Instructions

3M Eyewear Fit System

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

Force & Motion. Objective 6.P.1. 6.P.1 Understand the properties of waves and the wavelike property of energy in earthquakes, light and sound.

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Structure of Mechanically Agitated Gas-Liquid Contactors

Setting up and running a column

The Agility Association of Canada

Fly Rocket Fly: Design Lab Report The Zlatan 10W Submitted 12/22/2016 Student: James Hofmann Partner: Manuel Colino Parra Max Distance: 210 yds

SINGLE BRAID INSPECTION

CLEAN ROOM Innovation applied to sterilizable devices

KS3 Science Practise Test

Model 23H Hand Crank Seamer

Movement Options. Pairs

Underwater Housing for Canon EOS M

Gait Analyser. Description of Walking Performance

WXG-4 Manual Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Use this key to determine which sections of this Product Manual apply to your job.

Solutions. Digital pressure management solutions. Copyright 2013 GaleMed Corporation

Transcription:

An introduction to modern scleral lenses The subject of scleral lenses seems to divide eye care practitioners more than just about any other type of contact lens. Views range considerably-some believing them to be no more than a piece of optics history, that they would need training in taking impressions to fit them (which is no longer the case) or that the fitting process is too lengthy and complex to be used in every day practice. At the other end of the scale are eye care practitioners who are regularly identifying the most suitable cases for these lenses and enjoying fitting them with great success and happy patients. Interestingly, these are also customers that are not an obvious target for the multiples or internet sellers of contact lenses so in addition to being interesting to fit and having significant clinical benefits to some of your patients, they also represent a great business opportunity for the independent practitioner. Why do we still need scleral lenses? To fully understand the role of scleral lenses in today s contact lens market, we need to firstly be clear on the roles of other lenses that are likely to be more familiar. It s probably fair to say that soft lenses account for the majority of the contact lens business in most practices and rightly so. These lenses are fantastic, generally very easy to fit, patient friendly and if structured well, business friendly too. So what about when there isn t a suitable soft lens available? There may usually appear to be, but is it really the right lens for the job or just the nearest thing you have to it that s convenient to use? Think about the number of presbyopic patients you have. Almost half of them will have cyls of 0.75D or above in at least one eye 1. This then takes them out of range of most manufacturers fitting guidelines for soft multifocals. There are one two toric multifocals around but the process starts to become more complex, as trials usually need to be made to order, stability can be an issue and costs increase. Monovision is sometimes an option but does represent a compromise and research shows that multifocals outperform monovision in real world situations. Combined with the fact that we know the presbyopic age range is subject to the highest rate of drop outs, using a compromise as a starting point can only increase the chances of this unfortunate outcome. Gas permeable multifocal lenses can give your patient excellent distance and near vision, and can be toric if required without complicating the fitting process. Ordered empirically using accurate measurements and the appropriate fitting guide, these lenses will land on your desk in 2-3 days and most of the time the first pair will be successful.

Many cases of early keratoconus or other corneal irregularities can be managed well with corneal gas permeable lenses too, and there are specific designs available to help further in these cases. Why then do we need scleral lenses? They are available in a much wider range of prescriptions than most mass produced lenses as each pair is individually made to order, and available in spheres, cyls and multifocals. When keratoconus becomes more advanced and the cornea is protruding further, it can be more difficult to get a good fit and good comfort for your patient. The ideal situation in these cases is to take the bearing off the cornea completely and rest it on a tougher, less sensitive surface and this is the primary feature of the scleral lens. Scleral lenses are effectively fitted to the sclera (via the conjunctiva) and vault over the cornea, having absolutely no direct interaction with it at all-in fact it could be argued that if we are referring to the cornea it s not technically a contact lens at all! This results in comfort comparable with a soft lens even immediately after application, due to bearing on the less sensitive sclera rather than the cornea, and also having also eliminated any lid interaction with the lens edge-two of the main causes of contact lens awareness.this is what we are trying to achieve (figure 1). Figure 1 A commonly reported symptom of contact lens related discomfort during the wearing day is dryness. Scleral lenses address this impressively and could be another reason you may choose to fit them 2. The lens is filled with unpreserved sterile saline which is sealed in behind the lens, therefore ensuring that the cornea is protected all day long by this liquid reservoir. Lack of tear exchange is not the concern it would have once been due to the use of modern high dk gas permeable materials. The measurable vision with these lenses is usually better than with any of the possible alternatives, and your patient likely to report fewer visual symptoms such as fluctuations with blink, haloes and streaks.

Fitting So now we have established why these lenses are useful so let s look at how to fit them. Fitting is done by sag rather than the more traditional BCOR, and as a general guide, the more the cornea protrudes, the larger the sag required to vault over it and the larger the overall diameter will need to be to support the lens. The fitting process consists of 4 simple steps using a simple trial set and fitting guide. It is essential that the steps are followed in the correct order to achieve a good fit whilst minimising chair time. Step 1 Diameter Start with a trial lens that s around 4-5mm larger than HVID. The ideal lens will have no limbal touch-seen here as a darker crescent on the left of the cornea (Figure 2). If this is observed, the overall diameter of the lens needs to be increased. Figure 2

There should also be a 1mm complete ring of limbal clearance visible as a bright band surrounding the cornea. This ensures no interference with the function of the limbal stem cells. (Figure 3) Figure 3 Step 2: Sag & Vault (Clearance) The trial set should come with a fitting guide which will tell you where to begin. Remember these lenses are fitted by sag rather than BCOR which involves a slight alteration to your approach. Generally normal corneas or cases of early keratoconus will require starting with a lens with a smaller sag and more protruding or more irregular corneas will require a larger sag to enable it to vault over and totally clear the cornea. For example: Clearance should be a minimum of around 250-300 microns initially, settling back to around 150 after about 30 minutes. The cornea is around 500 microns thick so you can use this as a guide, but if you are aware of the thickness of your trial lens (for example Bausch & Lomb Maxim CV is 250 microns) this can make comparing the thickness of the liquid layer with something of a known thickness more accurate.

The back surface of the cornea, just visible (Figure 4), can be seen to be roughly the same thickness as the liquid layer which would imply it measures around 500 microns, so too thick 3, it should be closer to half this value. This means the sag needs to be smaller. Figure 4 Excess clearance or vault may also result in bubbles or debris visible with the slit lamp, and can also make the lens less comfortable. This would mean a smaller sag is required. (Figure 5) Figure 5

Central touch (too little vault or corneal clearance) is sometimes easier to see when new to fitting these lenses so it can be helpful to err on the side of smaller sag to begin with. For every 1mm of touch observed, you will need to increase the sag by around 0.10mm (Figure 6) Figure 6 Step 3: Edge The edge should sit flat across the sclera and should not cause impingement/blanching or compression of the conjunctival vessels. If it does then it is too tight and you would need to ask the manufacturer to make a looser edge (Figure 7). Figure 7

Bubbles should not be visible under the edge, nor should any lifting be observed. These are signs the edge is too loose (Figure 8). Figure 8 A well-fitting edge (Figure 9) Figure 9

Step 4 Over refraction, essentially the same as with any other lens, sphere first, cyl if needed but do be careful not to over minus and remember to compensate for BVD-the over refractions you are dealing with here may be larger than usual so it can be quite significant. Manufacturers provide excellent technical support to assist you when you are getting started with these lenses, and practical, CET accredited training is available to help build your confidence if required. -End-