Roofing Primer. Primer 610 Spray PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP

Similar documents
Roofing Adhesive PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Insulation Adhesive for Sarnafil Roofing Systems

PRESSURISED PAINT CONTAINER

Cylinder Spray Adhesive - User s Guide

3M Scotch-Weld Specialty Cylinder Spray Adhesives

Two-stage valve type NE

Solids Content of Adhesive propellant removed (by wt.): Solids Content aerosol (by wt.): 27.4% Volatile Organic Compounds (VOC):

Cylinder Adhesive for Geotextile Seaming

Scotch-Weld Super 77 Cylinder Spray Adhesives

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Technical Data Sheet PART A & PART B

NS Cylinder Spray Adhesive - User s Guide

1. CONDITIONS FOR USE 2. SAFETY

Assembly and Installation Procedures

Yoke Block Instruction Manual

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Flexi-pro Aerosol Delivery System (FADS) Manual

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Under Basin Storage Unit

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

APPLICATION GUIDE ECOSPEED FOR ALUMINIUM SURFACES

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

air/hydraulic nut riveter heavy-duty vacuum system

GAS BBQ 4 burner. instructions for. model no: BBQ10

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Material Safety Data Sheet

As Supplied : 1.67 lbs/gal (200 g/l) Plasite Thinner #71 : 10% by volume 2.18 lbs/gal (261 g/l)

Technical Data Sheet Effective: 04/05/2017 Supersedes: 01/01/2000

RhinoPro Cartridge Gun Manual

MANUAL. Sesame. Thermoplastic Tank Technologies

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 15 HI-SR 200 USA. Operating instruction APR SR 200 full face mask

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

RG1200 Service and Repair Manual

Code AWC20HP Air Compressor

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

TWO POST RAM PACKAGE 55 GALLON

FLANGED TWO-PIECE BALL VALVES

Installation & Operation Manual Proven Quality since 1892

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

User manual. ZX trolley.

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

80 Litre Suction Oil Drainer

Halsey Taylor Owners Manual STOP!

Yoke Block Instruction Manual

ambiente Installation Guide AmbiScreedboard system more than underfloor Customer: Project: Project Reference: Date:

118 - Quick-Start Processing

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Adjustment of SF6 pressure

Installation Instructions for NP100 Series Nitrogen Control Panels

Operating manual for Material pressure tanks Vol./1 and Vol./2

3 Fastbond TM. Cylinder Spray Contact Adhesive 30NF. Technical Data June, 2008

Lab Cock. Contents. User s Manual (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

ST 18 Aluminium Gas Model

Binks SV100 Conventional Suction Feed Spray Gun

ST 18 Aluminium Gas Model

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

MSA AUER SSR 90 [K60]

To be used as a coating for potable water tanks and pipes. Independently tested and certified for potable water storage. Other

Presence PR, PRC & PRE

Application & Care Reflexite V98 Conformable Graphic Sheeting For EMS Vehicle Graphic Applications RSA2340

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 36 C calculated VOC-US/Hong Kong US EPA method 24 (tested)

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Type BBS-03, BBS-05, BBS-06, BBS-25

TEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600

EVOSTONE Solid Surface - Material Safety Data Sheet (MSDS) EVOSTONE PROPERTIES

Velocity USER GUIDE CPU WATER BLOCK. 2nd Revision, October 18th 2018

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

FLANGED TWO-PIECE BALL VALVES

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

Operation and Maintenance Instructions

Tsunami Breathable Air System

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

BS ml Bottle Sampling Unit

Introduction to Ecoseal

Budget Range Operators Handbook

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Velocity USER GUIDE CPU WATER BLOCK. 1st Revision, September 6th 2018

CATALYZER TM 2K 10:1 RATIO Pump

INSTRUCTION MANUAL FOR POLYKEG DISPOSABLE KEG

Hardener: at least 24 months when stored cool and dry

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 33 C calculated VOC-USA / VOC Hong Kong EPA Method 24

TURBO SET 1000 E D $'9 5(9

AREA VALVE SERVICE UNITS

Model Portable Eyewash

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

Aerodur 2111 Chrome Free Primer

CIA-EA Technical Data Sheet

Transcription:

Roofing Primer Primer-610 Spray Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP PRODUCT DESCRIPTION TESTS PRODUCT DATA FORM Solvent-based synthetic-rubber bonding agent in a pressurized canister system. USES Primer 610 is a spray able primer to improve the adhesion for VCL layers, insulation adhesives and self-adhering membranes onto various roof decks. CHARACTERISTICS / ADVANTAGES Multipurpose spray primer Quick and easy professional application Primes to most common substrates No hot works with naked flames SUITABLE SUBSTRATES PIR insulation boards with lamination (glass or mineral fibre fleece) Oriented Strand Boards (OSB), plywood panels, timer boards Concrete, lightweight concrete, screed Metal deck Refurbishment applications (must be determined by testing) APPROVAL / STANDARDS Quality management system EN ISO 9001/14001 CONSISTENCY / COLOUR Liquid Colour PACKAGING Black One way canister: 19.66 kg (Adhesive 13.6 kg) Packaging unit: Pallet or single canister Packaging dimension: Cardboard box 320 mm x 320 mm x 460 mm 15h April 2016,V1 Language/Region/Translation template e.g. template for local adaption 1/5

STORAGE STORAGE CONDITIONS Store in dry conditions at temperatures between +5 C to +30 C SHELF-LIFE 12 months from date of production if stored properly in original, unopened and undamaged sealed container. Expiry date on container. The adhesive will have a limited life once the container is opened. TECHNICAL DATA CHEMICAL BASIS Synthetic Rubber/Resin APPLICATION FIGURES Temperature +30 C +20 C +10 C +5 C Open Time T gel 10 minutes 20 minutes 30 minutes 40 minutes SYSTEM INFORMATION APPLICATION DETAILS CONSUMPTION Consumption depends on the roughness and absorbency of the substrate and ranges from 75 g/m 2-125 g/m 2 on closed substrates to 200 g/m 2 on very absorbent substrates. One single canister can cover from 150 to 200 m 2 depending on application and substrate. SUBSTRATE QUALITY The substrate must offer sufficient cohesive and structural strength. SUBSTRATE PREPARATION The substrate must be resistant to solvent, firm, clean, dry, free of chemicals oil and grease. Metal must be cleaned before the primer is applied. COMPATIBILITY Do not use on the below substrates: EPS/XPS insulation boards Copper plate Waterproofing membranes (thermoplastics/elastomers) 2/5

APPLICATION METHOD GENERAL INFORMATION Based on the valid installation instructions of the relevant roof waterproofing membrane. The canister and gun will remain usable after opening. However if it used intermittently the primer in the hose and gun may require purging with approx. 250ml of primer through the system. If the canister and gun have been left for a prolonged period and appear blocked then it may require flushing with the Sika Canister Flushing System. Once the canister is empty, the gun/hose can be transferred to a new canister. CANISTER SET-UP It is important to set-up your Canister Adhesive correctly before use to ensure the best possible performance and to avoid leakage or system failure. 01. Remove the black cap form the canister valve. 02. Attach the rubber-hose to the canister valve (using the small nut) and attach the other end of the hose to the spray-gun (using the large nut). Tighten with a spanner. 03. Attach the other end of the hose to the spray-gun (using the large nut). Tighten with a spanner. 03. Using the locking-nut provided, attach the spray-tip to the end of the spray-gun. 04. Fully open the valve on the canister. 05. Pull the trigger on the spray-gun to apply adhesive. 06. Adjust the spray pattern by turning the black valve on the spray-gun anti-clockwise until you have a spray pattern approximately 300mm in width. CANISTER MAINTENANCE GUIDE Once work has been completed, ensure the valve on the canister remains open. Failure to do this may cause the primer to block the hose. 01. Turn the spray-gun off by turning the black valve clockwise until it is fully closed. 02. Unscrew the spray-tip and the end of the spray-gun. Clean the spray-tip and the end of the spray-gun with Flushing Spray Cleaner using a soft nylon brush to ensure that the aperture is clear. This is essential. Failure to clean the spray-tip and the end of the spray-gun may result in damage to the aperture and prevent the system from working. Place the spray-tip and locking-nut in a container with a small amount of Flushing Spray until it is needed again. Ensure the container is closed and airtight. 3/5

CANISTER FLUSHING SYSTEM 01. Ensure the valve on the canister is completely turned off before attaching the assembly. 02. Unscrew the hose from the canister valve. 03. Attach the assembly to the valve. Ensure the assembly remains upright whilst you tighten the nut on it. Attach the hose to the assembly. Ensure the assembly remains upright whilst you tighten the hose. 03. Check the tap on the assembly is off before applying the Flushing Spray Cleaner. Screw the Flushing Spray Cleaner into the hose and open the red valve. 04. Aiming the gun into a waste container, apply pressure to the trigger on the gun to push cleaner trough the hose and gun until the adhesive starts to dispense. Keep pressure on the trigger until the hose and gun are thoroughly cleaned. CANISTER DISPOSAL SYSTEM 01. The canister contains compressed gas. It should be emptied by carefully opening the valve, which will release any excess adhesive and/or pressure. Allow any excess adhesive and/or pressure to fully escape into a suitable container. Leave the valve open. Once the canister is empty and completely depressurized, the circular disk can be pierced using a non-ferrous bar/rod. Allow any remaining adhesive to cure. The empty depressurized canister should be disposed/recycled in accordance to regulatory requirements.. TOOL CLEANING Tools and equipment must be cleaned with Sika Spray Cleaner immediately after use. Purging the primer through the hose & application gun (approx. 250ml) may be necessary if it has stood for a long period. Alternatively flush the hose and application gun with the adaptor valve and Flushing Spray. NOTES ON INSTALLATION / LIMITS Installation works to be carried out only by trained Sika Roofing Contractors. Temperature limits for the installation of the primer: Substrate temperature: At least +5 C Ambient temperature: At least +5 C Installation of some ancillary products, e.g. contact adhesives / cleaners is limited to temperatures above +5 C. Please observe information given by s. Special measures may be compulsory for installation below +5 C ambient temperature due to safety requirements in accordance with national regulations. VALUE BASE All technical data stated in this are based on laboratory tests. Actual measured data may vary due to circumstances beyond our 4/5

2016 Sika Services AG control. LOCAL RESTRICTIONS HEALTH AND SAFETY INFORMATION LEGAL NOTES Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local for the exact description of the application fields. For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local for the product concerned, copies of which will be supplied on request. It may be necessary to adapt the above disclaimer to specific local laws and regulations. Sika Limited Sika Liquid Plastics Sika House, Miller Street, Preston, PR1 1EA United Kingdom Phone: 01772 259781 Fax: 01772 255670 Mail: liquidplastics@uk.sika.com 5/5