FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS This certificate is issued for the following equipment: FCa4cF1Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 XP-IS / I / 1 / BCD / T6 T1* - 3KXF000028G0009 DIP / II, III / 1 / EFG / T6* I / 1 / Ex d ia / IIB+H2 / T6 T1* - 3KXF000028G0009 h = material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; single digit alpha numeric code not critical to safety j = Density Calibration; single digit numeric code not critical to safety k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; D1, D2, D3, D4, D5, D6, D7, or D8 Additional Output 2; DSN, DSG, DSA, or DST Page 1 of 7
FCa4cF1efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 XP-IS / I / 1 / BCD / T6 T1* - 3KXF000028G0009 DIP / II, III / 1 / EFG / T6*; I / 1 / Ex d ia / IIB+H2 / T6 T1* - 3KXF000028G0009 e = Connection Design/Connection Box Material/Cable glands; U1, U2, A1 or A2 h = Material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; 2-digit alpha code not critical to safety j = Density Calibration; 2-digit numeric code not critical to safety l = Outputs; Y0 m = Power Supply; Y FCT4cF1klm CoriolisMaster Transmitter only XP-IS / I / 1 / BCD / T6 T1* - 3KXF000028G0009 DIP / II, III / 1 / EFG / T6*; I / 1 / Ex d ia / IIB+H2 / T6 T1* - 3KXF000028G0009 k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; R1, R2, R3, R4, R5, R6, R7, or R8 Page 2 of 7
Additional Output 2; DSN, DSG, DSA, or DST FCa4cF2Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / Ex na / IIC / T6 T1* h = material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; single digit alpha numeric code not critical to safety j = Density Calibration; single digit numeric code not critical to safety k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; D1, D2, D3, D4, D5, D6, D7, or D8 Additional Output 2; DSN, DSG, DSA, or DST 3. When m = C provision shall be made external to the equipment, to provide the transient protection device to be set at a level not exceeding 140 % of the peak rated voltage value of 42 V. FCa4cF2efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / Ex na / IIC / T6 T1* Page 3 of 7
, IP68 e = Connection Design/Connection Box Material/Cable glands; U1, U2, A1 or A2 h = Material of wetted parts; A1, A2, H1, H2, C1, C2, T1 or L1 i = Flow calibration; 2-digit alpha code not critical to safety j = Density Calibration; 2-digit numeric code not critical to safety l = Outputs; Y0 m = Power Supply; Y FCT4cF2klm CoriolisMaster Transmitter only NI / I, II, III / 2 / ABCDEFG / T6 T1* I / 2 / Ex na / IIC / T6 T1* k = Connection Design/Transmitter Housing Type/Transmitter Housing Material/ Cable Glands; R1, R2, R3, R4, R5, R6, R7, or R8 Additional Output 2; DSN, DSG, DSA, or DST Page 4 of 7
3. When m = C provision shall be made external to the equipment, to provide the transient protection device to be set at a level not exceeding 140 % of the peak rated voltage value of 42 V. Equipment Ratings: FCa4cF1Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups BC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIB+H2; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA12.27.01 FCa4cF1efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups BC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIB+H2; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA12.27.01 FCT4cF1klm CoriolisMaster Transmitter only Explosionproof with intrinsically safe communications per control drawing - 3KXF000028G0009 for Class I, Division 1, Groups BC&D; Dust-ignitionproof for Class II Division 1, Groups EF&G and Class III, Division 1 and 2; Flameproof with intrinsically safe communications options for Class I, Zone 1 Group IIB+H2; Protected by enclosure with intrinsically safe communications options for Zone 21 Group IIIC hazardous (classified) locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T6 for Class II and III dependent on ambient temperature and process temperature per ABB instruction Manual. Temperature class T80 C for Zone 21 dependent on ambient temperature and process temperature per ABB instruction Manual. FCa4cF2Y0fghijklm CoriolisMaster Integral single seal double seal with option TE2 FCa4cF2efghijY0lm CorioisMaster - Remote sensor single seal double seal with option TE2 Nonincendive for Class I, II and III, Division 2, Groups ABCDEF&G; Type of protection na for Class I, Zone 2, Group IIC Hazardous (Classified) Locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Dual Seal or Single Seal per ANSI/ISA12.27.01 FCT4cF2klm CoriolisMaster Transmitter only Nonincendive for Class I, II and III, Division 2, Groups ABCDEF&G; Type of protection na for Class I, Zone 2, Group IIC Hazardous (Classified) Locations. Temperature class T6 T1 for Class I dependent on ambient temperature and process temperature per ABB instruction Manual. Page 5 of 7
FM Approved for: ABB Automation Products GmbH Göttingen, Germany Page 6 of 7
This certifies that the equipment described has been found to comply with the following Approval Standards and other documents: CSA C22.2 No. 30 2012 CSA C22.2 No. 94 2011 CAN/CSA C22.2 No. 142-M1987 2009 CAN/CSA C22.2 No. 213-M1987 2013 CAN C22.2 No.157-92 2012 CAN C22.2 60079-0 2011 CAN C22.2 60079-1 2011 CAN C22.2 60079-11 2014 CAN C22.2 60079-15 2012 CAN/CSA C22.2 No. 60529 2010 CSA C22.2 No. 1010.1 2004 ANSI/ISA 12.27.01 2003 Original Project ID: 0003050239 Approval Granted: October 22, 2015 Subsequent Revision Reports / Date Approval Amended Report Number Date Report Number Date RR203300 December 29, 2015 FM Approvals LLC J.E. Marquedant Manager of Electrical Systems 29 December 2015 Date Page 7 of 7