Modified Setup of 20-L-Sphere for the Determination of Safety Characteristics of Nano Powders

Similar documents
Dust explosion severity characteristics of Indonesian Sebuku coal in oxy-fuel atmospheres

New Findings for the Application of Systems for Explosion- Isolation with Explosion Venting

Rotary air valves used for material feed and explosion protection are required to meet the criteria of NFPA 69 (2014)

THE EXTERNAL EXPLOSION CHARACTERISTICS OF VENTED DUST EXPLOSIONS.

Inert Substances and Explosion Limits of Hybrid Mixtures

Influence of Initial Temperature on Explosion Severity Parameters of Methanol/Air Hybrid Mixture Measured in 1-m 3 Vessel

The Use of Porous Structures in Flameproof Enclosures to Reduce the Maximum Explosion Pressure

Blast Damage Consideratons for Horizontal Pressure Vessel and Potential for Domino Effects

The Explosive Decomposition of Tetrafluoroethylene: Large Scale Tests and Simulations

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Technical Data Sheet MF010-O-LC

Pilot Operated Safety Relief Valves For Liquified Gas Carriers

Ignition Sensitivity of Nonmetallic Materials in Oxygen-Enriched Air NITROX : A Never Ending Story in SCUBA Diving?

SAFE AND ENVIRONMENTALLY FRIENDLY

Supplementary Operator s Manual 42/24-14 EN Rev. 3

NEW DEVELOPMENTS FOR OPTIMAL SELECTION OF FILTER MEDIA IN FINE DUST BAG- HOUSE FILTRATION

Laboratory Mortar Mixer (Testing)

EXPLOSION PROTECTION USING THE DATABASE. Maria Molnarne. formerly at BAM Federal Institute for Materials Research and Testing, Berlin, Germany

CFD SIMULATIONS OF GAS DISPERSION IN VENTILATED ROOMS

Fig. 2. M.I. Yaroslavtsev, 2002

INFLUENCE OF INITIAL PRESSURE ON THE IGNITION AND COMBUSTION OF A PROPELLING CHARGE. Patrice Franco

NGN Series nitrogen generator

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

Guidelines for Handling Dry Materials

STORAGE OF HAZARDOUS CHEMICAL AGENTS (HCA)

CISAP-2 2 nd International Conference on Safety & Environment in Process Industry CISAP-2. May, 21-24, 2006, Naples, Italy

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

SAFETY DATA SHEET CLEARAM CJ MODIFIED STARCH

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Oxygen measurement in diving technology

CASH VALVE TYPE KP BACK PRESSURE VALVES

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

Safety Shut-Off Valve HON 720

School of Chemistry SOP For Operation Of Glove Boxes

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

Instruction Manual. Pipe Friction Training Panel

Determination of explosion characteristics of dust clouds

Analysis and Comparison of Calculation Methods for Physical Explosions of Compressed Gases

PRESSURE REGULATOR LBM SERIES

Equipment Operating Procedure Glove Box

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

ZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION

Determination of explosion characteristics of dust clouds

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

Flexible Method for Corrective Actions Ranking in the Field of Protection Against Explosion

Flexvent floatvents: reliable and easy to mount

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

Standard Test Method for Minimum Explosible Concentration of Combustible Dusts 1

E. MENDOZA, C. KEMPEN, Y. ESTERKIN, S. SUN, K. SUSKO and J. GOGLIA

REACTOR DESIGN AND SAFETY

Processing instructions V REFRAJET Addmix nozzle

Constant Pressure Inlet (CCN) Operator Manual

Flexvent. Venting range and dirt separators. Air pots LTA

DESIGN AND PERFORMANCE OF THE NEW SARTORIUS 1 KG VACUUM MASS COMPARATOR AT PTB

Pipeline Flooding, Dewatering and Venting Dr Aidan O'Donoghue, Pipeline Research Limited, Glasgow, Scotland

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

SAFETY DATA SHEET ZERO VALENT IRON POWDER

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes

SAFETY DATA SHEET CLEARGUM LG SECTION 1: Identification of the substance/mixture and of the company/undertaking

Instruction Manual Dräger MSI P7 and MSI P7 plus

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

Study on Intensity of Blast Wave Generated from Vessel Bursting by Gas Explosion

SHAPA TECHNICAL PAPER 10 (Revised) SIZING OF EXPLOSION RELIEF VENTS DAVID BURN FIKE UK LTD

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

HP/UHP Spring-Loaded Regulator

Slam Shut Valves SCN

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure

Explosion Parameters of Degas-Air Mixtures at Elevated Temperatures

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

Analysis of the Resistance of Structural Components to Explosive Loading by Shock-Tube Tests and SDOF Models

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Drilling Efficiency Utilizing Coriolis Flow Technology

SAFETY MANUAL PURGING, VENTING & DRAINING PROCEDURE TABLE OF CONTENTS 1. INTRODUCTION SCOPE DEFINITIONS PROCEDURE...

Investigations of Deflagration in a Four-Litre-Autoclave under Atmospheric and Non-Atmospheric Conditions

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

CONSIDERATION OF DENSITY VARIATIONS IN THE DESIGN OF A VENTILATION SYSTEM FOR ROAD TUNNELS

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Experiment 18 Properties of Gases

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

ACCIDENTAL HYDROGEN RELEASE IN GC-LABORATORY; A CASE STUDY

4.1 Why is the Equilibrium Diameter Important?

Sartorius CCL kg Prototype Mass Comparator

AMENDMENTS TO THE IMSBC CODE AND SUPPLEMENTS


The Split of Two-Phase-Flow at Horizontal Side-T-junctions in Unbalanced Pipe Systems for Clean Extinguishing Agents

Safety Shut-off Valve SSV

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

CHAPTER 31 IDEAL GAS LAWS

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Pressure and Flow Control Valves DBGM, German and European Patents

Over the last decade, mechanical vacuum systems

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

Transcription:

805 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 31, 2013 Guest Editors: Eddy De Rademaeker, Bruno Fabiano, Simberto Senni Buratti Copyright 2013, AIDIC Servizi S.r.l., ISBN 978-88-95608-22-8; ISSN 1974-9791 The Italian Association of Chemical Engineering Online at: www.aidic.it/cet Modified Setup of 20-L-Sphere for the Determination of Safety Characteristics of Nano Powders Arne Krietsch* a, Tim-Michael Romahn b, Marc Scheid a, Ulrich Krause b a Federal Institute for Materials Research and Testing (BAM), Department 2 Chemical Safety Engineering, D-12200 Berlin, Germany b Otto-von-Guericke-University of Magdeburg, Chair of System Engineering and Plant Safety, Universitätsplatz 2, 39106 Magdeburg, Germany arne.krietsch@bam.de This paper describes a modified experimental setup for the test apparatus 20-L-Sphere (also known as 20-L Siwek Chamber), that enables the test samples to be kept under inert atmospheric conditions nearly until ignition. This setup was designed to allow the determination of safety characteristics of nanopowders under most critical circumstances (e.g. minimisation of the influence of oxidation before the test itself). The aim of this modification was to determine, whether or not the current setup and procedures underestimate the explosion violence and ignitability of nanopowders. The work includes experimental results of micrometer dusts to validate the modified setup. Moreover first results of nanometer iron and aluminium dusts are presented, which were kept at inert conditions until shortly before the ignition. The tested nano iron was found to react pyrophoric, as soon as it gets in contact with air, while the tested nano aluminium did not generally show such behaviour. 1. Introduction Nanotechnology is one of the fastest growing industries at present and probably will be for the next decades. This development particularly results from the modified properties of materials within the nanometer range. The different types of behaviour of such substances and the lack of knowledge about their interaction with the environment require intensive investigation for risk assessment. For this reason health effects of nanoscale materials on the human organism for example are examined in numerous studies and research projects. Conversely in depth experience and knowledge of fire and explosion risks in the production, handling and transport of nanoscale materials and particles with sizes below one micrometer are not widely available. Based on experience of dusts with particle sizes in the micrometer range it is well known that dusts are classified more critically with decreasing particle size, as their explosion severity and ignition sensitivity increase. Explosion properties of combustible dusts are described with safety characteristics. Experimental data about determination of safety characteristics of nanometer powders published for example by Holbrow et al. (2010) or Bouillard et al. (2010) which are the basis for risk assessment and design of prevention and protection measures are still limited. Furthermore existing studies were carried out in accordance to international standards like EN 14034 series (2011) or ASTM E1226-10 (2010) for the determination of safety characteristics of combustible dusts in general. However it was not verified whether or not these standardised test methods are also suitable for a reliable evaluation of the combustion and explosion behaviour of nano powders. For example surface passivation may however result in a decrease of ignition sensitivity and reactivity before the test itself. Such processes are already well known for metallic micrometer dusts. The effect could be increased by the greater specific surface area of nanoscale powders. This would complicate a direct comparison of safety characteristics of micro- and nanopowders without taking the oxide content into account. Available safety characteristics do usually not contain information about the oxide content of investigated powders. Published explosion characteristics and studies like those from Eckhoff (2012) and Worsfold et al. (2012) on the explosion beaviour of nanodusts

806 did not consider that subject. This paper shows a possible experimental approach to evaluate the oxidation effect on the explosion behaviour of nanodusts. The test results could be used for the development of new test equipment for the determination of safety characteristics of nanodusts or the modification of standard equipment and procedures. 2. Experimental According to EN 14034 series (2011) and ASTM E1226-10 (2010) the 20-L sphere (Figure 1) is used for the determination of the safety characteristics maximum explosion pressure P max, maximum rate of pressure rise (dp/dt) max or explosibility index (K St ) and lower explosion limit (LEL). It consists of a hollow sphere of 20 litres internal volume made of stainless steel. For testing, a dust sample is placed in the storage chamber, pressurised and then dispersed into the sphere via the outlet valve and the rebound nozzle. Therefore the explosion chamber must be evacuated to 0.4 bar absolute while the dust container is filled with 21 bar absolute of compressed air. The evacuation of the explosion chamber is necessary to ensure ambient pressure after the dispersion process. water outlet outlet pressure sensors ignitors rebound nozzle 20 barg water inlet compressed air dust container outlet valve Figure 1: Schematic of standard 20-L sphere (edited from VDI 2263-1, 1990) 2.1 Modified experimental setup For the determination of the most critical behaviour of nanopowders it is necessary to test powders which were produced and transported, without or with only a minimum of oxygen. To minimize the influence of oxygen passivation during testing it is in addition to that necessary to handle such samples under absence of oxygen until the time of ignition. A suitable experimental setup to implement that is placing test equipment and sample preparation into an enclosure with controllable gas atmosphere. Thus a special glovebox system operated with nitrogen has been developed in which test equipment such as the 20-L sphere and the sample preparation were integrated. For each test also the test chamber of the 20-L sphere is flushed with nitrogen. Especially metallic nanopowders can ignite spontaneously during the injection process into the explosion chamber. Main reasons for that are the high ignition sensitivity of such substances and high shear forces that can occur during the dispersion process into the explosion chamber (Wu et al., 2010). This behaviour may lead to increased wear of parts of the test apparatus (e.g. outlet valve). Moreover, these uncontrolled early ignitions do not allow obtaining reliable safety characteristics of respective. Therefore - contrary to the standard test procedure - the samples were directly placed into the explosion chamber. In order to disperse the dust adequately, a special mushroom nozzle was used. This nozzle is shown in Figure 2. With this method and the inerted explosion chamber the dust sample gets in contact with oxygen only shortly before ignition (approximately 60 ms). In order to ensure ambient oxygen concentration at time of ignition the test gas, which is injected from the dust container through the outlet valve into the explosion chamber, had to be enriched with oxygen. The increased oxygen content of the test gas was calculated on basis of the ideal gas law.

807 0 50 100 (mm) Figure 2: Image of the so called mushroom nozzle within the explosion chamber of the 20-L sphere Glovebox 1 Glovebox 2 5 7 1 2 9 12 8 13 14 15 4 3 6 11 16 KSEP 310 KSEP 332 10 1. exhaust gas cleaner 9. safety switch 2. 20-L explosion chamber 10. vacuum pump for explosion chamber 3. dust storage container 11. vacuum pump for preparation chamber 4. outlet valve 12. antechamber 5. oxygen sensor 1 13. nitrogen pressure reducing valve 6. oxygen sensor 2 14. glove box inerting pressure reducing valve 7. oxygen sensor 3 15. glove box inerting pressure reducing valve (during operating vacuum cleaner) 8. oxygen sensor 4 16. oxygen pressure reducing valve Figure 3: sketch of the modified setup

808 A sketch of the modified experimental setup is shown in Figure 3. The modified experimental setup consists of two separated work stations. Glove box 2 is used for storage and preparation (e.g. weighing of the sample), while the 20-L sphere (or any other test apparatus) is placed into glove box 1. Both work stations are linked by an antechamber (12), which can be locked on both sides. This gives the opportunity to operate both glove boxes independently from each other under inert conditions. Especially the box for sample preparation needs to be kept under inert conditions constantly. Otherwise the total amount of powder to be examined would be exposed to oxygen. In order to monitor the oxygen content inside the glove boxes and to ensure an inert atmosphere two oxygen sensors are installed in each box (5-8). The test gas is premixed in the dust container before each test. For this purpose, first oxygen is injected into the dust container. The pressure is controlled by a fixed pressure reducing valve (16). The gas supply is manually regulated by a diaphragm valve. An additional ball valve is used to limit the volume of the dust container to the standardized 0.6 L (otherwise the volume of the dust container would be enlarged by the volume of the pipes). It also prevents the backflow of the test gas, when the dust reservoir is fully loaded with 21 bar absolute. Nitrogen is supplied to both glove boxes with 21 bar absolute. The inlet pressure is reduced by another pressure reducing valve (14) to avoid sudden overpressure inside. Nitrogen is injected into the glove boxes by perforated stainless steel tubes. The supply is controlled by solenoid valves and can additionally be accurately dosed via needle valves. 3. Validation To validate the modified setup, tests with two different dust samples have been conducted. A lignite and a maize starch dust were chosen for these tests. The tested lignite dust has a median value of 37.7 μm and a specific surface area of 4.9110 m² g -1 (BET surface area), while the median value of maize starch amounts to 13.5 μm and the specific surface area is 2.4857 m² g -1 (BET surface area). Table 1: Validation results for lignite and maize starch Characteristic lignite maize starch Standard test Modified setup Standard test Modified setup P max [bar] 8.7 8.3 8.4 8.7 dp/dt max [bar s -1 ] 793 883 614 596 K St [bar m s -1 ] 215 240 167 162 LEL [g m - ³] 30 30 30 30 Pmax maximum explosion overpressure dp/dtmax maximum pressure rise KSt dust explosion constant LEL lower explosion level The validation results for both dusts are shown in Table 1. It can be seen that tests with modified setup and standard method delivered mostly comparable results within the margin of uncertainty that is usually reached in dust explosion tests. The values for P max are really close to each other. While for lignite the maximum overpressure determined with the modified setup is a little bit lower (8.3 bar instead of 8.7 bar with standard test method) it is vice versa for maize starch (8.7 bar with modified setup and 8.4 bar with standard test method. But values for P max are still within the tolerance level (10 % for P max ). The results for the pressure rise (614 bar s -1 with standard method and 596 bar s -1 with modified setup) and K St -value respectively for maize starch show a good agreement as well. Only for lignite the K St -value determined with the modified setup (883 bar s -1 ) is higher than the result of the standard test (793 bar s -1 ). Although this value is considerably higher, it is still within the tolerance level. Results for the lower explosion level are for all dusts and methods the same. This preliminary validation has shown that modified setup and standard test method deliver comparable results for the tested dusts. For a final validation a much higher amount of different dust samples needs to be tested. 4. Results of first tests with nano dusts For first tests with dusts produced in the nanometer range, nano iron and nano aluminium were chosen. Properties of both dusts are listed in Table 2. Although particles of both dusts are produced in the upper nanometer range, laser diffraction analysis has shown, that these primary particles form agglomerates in the lower micrometer range. While iron seems to form smaller agglomerates (about 1.4 μm) than the tested aluminium (about 4 μm) it has a much smaller specific surface area (7.6 m² g -1 ) than the aluminium which has a specific surface area of 18.3565 m² g -1.

809 Table 2: Properties of tested dusts produced in the nanoscale nano aluminium nano iron Median value (laser diffraction) 4.028 μm 1.493 μm BET surface area 18.3565 m² g -1 7.6036 m² g -1 Median primary particle size 90 110 nm 90 110 nm (supplier information) Oxide content 9 mass-% 4 mass-% Both dusts were furthermore examined with a Scanning Electron Microscope (SEM). Figure 4 shows two SEM images of nano aluminium. The left picture illustrates the agglomerate of a lot of smaller primary nanoparticles. On the first view there seems to be no difference to particles within the smaller micron range. But a closer look (picture on the right side of Figure 4) reveals that there are a lot of cavities and pores which increase the specific surface area. For a better comparison BET measurements of an aluminium dust, consisting of spherical primary particles with a median diameter of about 4 μm, have been carried out. These measurements with micrometer aluminium resulted in a specific surface area of 1.9981 m² g -1. Hence, although the nano particles formed agglomerates within in the micrometer range, even these agglomerates have a much higher specific surface area than comparable micrometer particles. It needs to be further investigated, whether or not this trend is generally applicable to even smaller nanoparticles and if or how this higher surface area affects the explosion behaviour. Figure 4: SEM images of nano aluminium at different resolutions Results of first tests in the 20-L-Sphere with nano aluminium and nano iron are presented in Table 3. Nano iron has shown pyrophoric behaviour. Thus it was not possible to determine explosion characteristics with the standard test method. With the modified setup it was possible to handle this dust until dispersion within the explosion chamber. Nevertheless the results cannot be considered as real explosion characteristics, because first of all iron ignited spontaneously, as soon as the oxygen/nitrogen-mixture was injected into the explosion chamber (that means before the ignition was triggered). The second problem is that the mentioned spontaneous ignition occurred when the pressure inside the explosion chamber was still below ambient conditions. This means, that the dust ignited below 1 bar absolute, at a much lower oxygen concentration and when the outlet valve was still open. The latter leads to the problem of an bigger volume of the test apparatus. Unfortunately these tests with nano iron needed to be aborted already at a concentration of 250 g m -3 because the damage to the outlet valve was too high. It can be furthermore seen that maximum overpressure and lower explosion level of nano aluminium are comparable or equal. However measured values with the modified setup for the pressure rise are lower than the results with the standard test method. One could assume that oxidation of the test sample before ignition does not influence safety characteristics because of these results. This is not necessarily the case, because aluminium needs to be oxidised partially after manufacturing in order to be safer for transport. Although the manufacturer tried to reduce the oxide content to a minimum, measurements have shown that the dust was already partially oxidised (Table 2). Responsible for the lower values with the modified setup is thus probably the weaker dispersion by the bowl nozzle of very heavy dusts like metallic dusts. For those heavy dusts (which can be dispersed weakly) further tests with passivated samples under

810 variation of the ignition delay time need to be conducted, in order to verify whether or not comparable results with the standard test method are possible. Table 3: Test results of nano aluminium and nano iron Test result nano aluminium nano iron Standard test Modified setup Standard test Modified setup P max [bar] 9.7 9.1-3.4 (only until 250 g m -3 ) dp/dt max [bar s -1 ] 1806 1267-525 (only until 250 g m -3 ) K St [bar m s -1 ] 490 344-143 (only until 250 g m -3 ) LEL [g m³] 30 30-60 5. Conclusion/Final Remarks The aim of this paper was first of all to introduce a new approach to investigate the influence of oxide content to safety characteristics of dusts consisting of primary nano particles. Therefore a modified setup was designed. It has been shown that there are still some problems that need to be solved. Even though with the modified setup it is possible to investigate, how the higher oxide content influences test results, because oxidation before the test itself can be avoided. It is furthermore able to get rough information about the explosion behaviour of pyrophoric dusts, which cannot be tested in general with the standard procedure so far. To fully understand the influence of oxygen on explosion behaviour of nano dusts further research will be done. It is therefore first of all necessary to determine the oxygen content of the sample to be tested. Besides the determination of the specific surface area this is crucial for the characterisation of the sample and for a proper clarification of the determined characteristics. The next research steps will include the improvement of the modified setup to ensure comparable results with the standard setup even for heavier dusts like metal dusts. In addition to that more dusts with different oxide contents and particle sizes will be tested. The research was funded by the DGUV (Deutsche Gesetzliche Unfallversicherung). The responsibility for the content of this publication lies with the authors. References ASTM E1226-10, 2010, Standard Test Method for Explosibility of Dust Clouds. ASTM International. Bouillard, J., A. Vignes, O. Dufaud, L. Perrin and D. Thomas, 2010, "Ignition and explosion risks of nanopowders." Journal of Hazardous Materials 181 2010: 873-880. Eckhoff, R. K. 2012, "Does the dust explosion risk increase when moving from μm-particle powders to powders of nm-particles?" Journal of Loss Prevention in the Process Industries 25 (2012): 448-459. EN 14034-1, 2004+A1:2011, Determination of explosion characteristics of dust clouds - Part 1: Determination of the maximum explosion pressure pmax of dust clouds. European Committee for Standardisation (CEN). EN 14034-2, 2006+A1:2011, Determination of explosion characteristics of dust clouds - Part 2: Determination of the maximum rate of explosion pressure rise (dp/dt)max of dust clouds. European Committee for Standardisation (CEN). EN 14034-3, 2006+A1:2011, Determination of explosion characteristics of dust clouds - Part 3: Determination of the lower explosion limit LEL of dust clouds. European Committee for Standardisation (CEN). EN 14034-4, 2004+A1:2011, Determination of explosion characteristics of dust clouds - Part 4: Determination of the limiting oxygen concentration LOC of dust clouds. European Committee for Standardisation (CEN). Holbrow, P., M. Wall, E. Sanderson, D. Bennett, W. Rattigan, R. Bettis and D. Gregory, 2010, Fire and explosion properties of nanopowders, prepared by the Health and Safety Laboratory for the Health and Safety Executive (HSE) 2010,. S. Morgan Worsfold, Paul R. Amyotte, Faisal I. Khan, Ashok G. Dastidar and R. K. Eckhoff, 2012, "Review of the Explosibility of Nontraditional Dusts." Industrial & Engineering Chemistry Research 2012,. VDI 2263-1, 1990, Dust Fires and Dust Explosions; Hazards - Assessment - Protective Measures; test methods for the Determination of the Safety Characteristics of Dusts. VDI - Verein Deutscher Ingenieure.