HOW TO MANAGE VAPORIZATION IN AN ANALYTICAL SYSTEM By Dean Slejko and Tony Waters

Similar documents
ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

H o w t o U s e a R e g u l a t o r t o R e d u c e T i m e D e l a y i n a n A n a l y t i c a l S y s t e m

Fundamentals of NGL Sampling Systems. By Dominic Giametta & Jim Klentzman

Gerald D. Anderson. Education Technical Specialist

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Chapter 3. Solids, Liquids, and Gases

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Improving distillation tower operation

Rate of Flow Valve Series 120

Using P-T Analysis As A Service Tool

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Cover Page for Lab Report Group Portion. Pump Performance

Micro Motion 3098 Gas Specific Gravity Meter

Generating Calibration Gas Standards

BACK PRESSURE / SUSTAINING

ACV-10 Automatic Control Valve

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

BACK PRESSURE / SUSTAINING

UsER manual for Watersens ph -REDOX

Armfield Distillation Column Operation Guidelines

SAMSON SOLUTIONS Energy and Power (Critical Applications)

Chapter 13 Gases, Vapors, Liquids, and Solids

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

Transient Analyses In Relief Systems

GAS SUPPLY SYSTEMS. for the flat glass industry

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Agilent Flowmeter ADM1000

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

TECHNICAL BULLETIN CRYOGENIC APPLICATION SERVICES. website:

FAS-W. Features. Applications. Automatic condensation hygrometer

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

11.1 Dumas Method - Pre-Lab Questions

TekValSys MP. Multi Phase Separator. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys TEKVALSYS

Degassing ERC KK Saitama, Japan

Influence of real phase equilibria on the sizing of pressure relief devices

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

1. If grams of the vapor of a volatile liquid can fill a 498 ml flask at o C and 775 mm Hg, what is the molecular mass of the gas?

Intermolecular Forces

--- III. itti A. on_ coo. & EP Department DOCUMENT NO: WOC-HSE-ST Section H005 Hydrates

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Quantitative Analysis of Hydrocarbons by Gas Chromatography

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.

What I have learned about SF 6 gas testing.a Practical explanation

Fit for Purpose Compositional Input for Allocation Using Equations of State Thomas Hurstell, Letton Hall Group

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

Calibration and Switching Module

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Outcomes: Operationally define vapour pressure

Under pressure pushing down

Air Eliminators and Combination Air Eliminators Strainers

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Model Series 62 Constant Differential Relay

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

PE096: Overview of Gas Processing Technology

Expansion Tank Design (Chilled Water)

Micro Motion Multiphase Applications

Thermodynamics ERT 206 Properties of Pure Substance HANNA ILYANI ZULHAIMI

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

MMS Mercury Monitoring System for Natural Gas

Operating Guidelines for PermSelect Modules Liquid Contacting

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Chapter 13 Temperature, Kinetic Theory, and the Gas Laws 497

Design Change Notification

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

TECHNIQUES OF COMPOSITE SAMPLING. Kris Kimmel. YZ Systems, Inc Pollok Drive Conroe, Texas 77303

EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS. ASSIGNMENT No. 4

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

44 (0) E:

AMT-Ex Dewpoint Transmitter

TR Electronic Pressure Regulator. User s Manual

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Chapter 3 Atmospheric Thermodynamics

Bubble Tube Installations

Technical Information

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes

Considerations for Sampling Wet, High Pressure, and Supercritical Natural Gas. Presented by: Shannon M. Bromley

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Chapter 8: Reservoir Mechanics

Phase Changes * OpenStax

METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

POWER FLUSH KIT INSTRUCTIONS

4/26/16. Section 1 Understanding Solutions. Solutions and Suspensions. Solutions and Suspensions. Solutions and Suspensions. Solvents and Solutes

Transcription:

HOW TO MANAGE VAPORIZATION IN AN ANALYTICAL SYSTEM By Dean Slejko and Tony Waters If the analyzer in your analytical system requires gas but your sample is liquid, the only option is to convert the liquid to gas. This process is called vaporization or flash vaporization. The objective is to convert a sample of all liquid to all vapor instantly without changing the composition. It is not easy to vaporize a sample, nor is it always possible, so make sure it s really necessary and possible before you try. You should always analyze a liquid in a liquid phase unless there are strong reasons for analyzing in a vapor phase. If you proceed with vaporization, it s important to understand the difference between evaporation and vaporization. Evaporation occurs gradually with an increase in temperature. Vaporization occurs instantly with a drop in pressure. It s not possible to vaporize a sample by increasing temperature. Heat causes evaporation, and adding more heat simply makes evaporation happen faster. In a mixed sample, evaporation will allow some compounds to evaporate before others, resulting in fractionation. Vaporization, done properly, ensures that all of the compounds vaporize at the same time, preserving the sample s composition. However, it is possible for things to go wrong when vaporizing. Instead of flashing the whole sample into a vapor, you could unintentionally cause a combination of vaporization and evaporation. The result would be fractionation. Once a sample of mixed compounds fractionates, it is no longer suitable for analysis. With fractionation, a common scenario is for lighter molecules to evaporate first and travel on toward the analyzer, while the heavier molecules remain behind in the liquid phase. Even if at some later point in the process a fractionated sample appears to be all gas, the mixture will not be of the same molecular proportions as it was before fractionation. It will no longer accurately represent the product taken from the process line. Let s take a closer look at the process of vaporization and how we can manipulate the variables temperature, pressure, and flow to ensure proper vaporization and an accurate analytical result. Understanding Vaporization To vaporize a sample, one typically uses a vaporizing regulator, also called a vaporizer, which is a pressure-reducing regulator with the capacity to transfer heat to the sample at just the right location. Vaporization consists of a three-stage process (Figure 1). First, the sample enters the vaporizer as a liquid. At this point, the liquid should not be bubbling or boiling. Second, the liquid passes through the regulating orifice in the vaporizer, resulting in a severe and sudden pressure drop, which vaporizes the liquid. At the same time, heat is applied, which enables the vaporized liquid to remain a vapor. Third, the sample, now a gas, exits the vaporizer and travels to the analyzer to be read. Due to the immediate transition to the vapor phase, the composition of the gas is unchanged from that of the liquid, ensuring an accurate reading. In this delicate process, there are many variables or inputs that determine success or failure. For the purpose of this discussion, let s say there are two main sets of inputs. The first set of inputs concerns the composition of the sample. Depending on the composition of the sample, it will begin to bubble and finish vaporizing at different pressures and temperatures. We ll need to know what these pressures and temperatures are to successfully manage the process. Figure 1. The three-stage vaporization process. 1.

The second set of inputs concerns settings that you control in your sampling system: pressure, temperature, and flow. Pressure and temperature are controlled at the vaporizer, while flow is controlled downstream at a rotameter (variable area flowmeter) and needle valve. We set these inputs based on what we know about the first set of inputs. Proper vaporization requires a delicate balance of all inputs. Even when approaching vaporization in a systematic manner like this, the process does require some trial and error, so we ll also talk about how to diagnose and address problems. Understanding Your Sample The best way to understand the first set of inputs is with a phase diagram. A phase diagram plots pressure and temperature, showing at any pair of conditions whether a substance will be vapor, liquid, or solid. The lines indicate the interfaces between two phases. Phase diagrams for most pure gases are available on the Internet, for example at http://encyclopedia.airliquide.com. But diagrams for gas mixtures are very difficult to create without commercial software. Figure 2 represents a phase diagram for 20 percent hexane in pentane. When the sample is above the bubble point (blue line), it s all liquid. We want the sample to be all liquid when it enters the vaporizer. When the mixture is below the dew point (gold line), it s all vapor. The sample must be all vapor when it leaves the vaporizer. Between the bubble point and dew point lines is what we call the no-go zone. This zone is the boiling range of the sample. Here, the mixture is in two phases, part liquid and part vapor. Once a sample falls into the no-go zone, it is fractionated and no longer suitable for analysis. The objective in vaporization is to set the temperature, flow, and pressure so that the sample skips instantly from the liquid side of the no-go zone to the vapor side of the no-go zone. With pure and nearly pure samples, there is little to no boiling range or no-go zone. The bubble point and dew point lines are on top of each other or nearly so. Indeed, pure and nearly pure samples will convert to vapor of the same composition, whether through evaporation or vaporization. Some industrial samples approach this level of purity and convert easily. On the other hand, some samples have such a wide boiling range or no-go zone that they cannot be successfully vaporized. There is no way to skip from the liquid side of the no-go zone to the vapor side of the no-go zone. We are unable to manipulate the variables temperature, flow, and pressure in such a way as to avoid fractionation. Most samples fall between these two extremes. For example, in Figure 2, the band between bubble point and dew point is narrow enough that with the proper settings we can enable the sample to effectively skip from the liquid side of the no-go zone to the vapor side. At the same time, the band in Figure 2 is wide enough that we cannot afford to be careless. Indeed, we will need to be skillful in our manipulation of the variables or we will end up with a sample in the no-go zone. Figure 2. Phase diagram showing 20 percent hexane in pentane, with temperature settings 2.

Setting Temperature, Pressure, and Flow Let s continue to work with the sample in Figure 2 (20 percent hexane in pentane) and see how we can set our inputs to ensure successful vaporization. In general, at the inlet, we want high pressure and low temperature. At the outlet, we want high temperature and low pressure. But there are limits as to how high and low these parameters can be, and not all of them are under our control completely. Vaporization is basically a balancing act between the variables. Here is a four-step process for setting your inputs. First, determine the inlet pressure at your vaporizer. This pressure, which is fixed, is your process pressure, provided your vaporizer is located close to your sample tap. In Figure 2, that pressure is 4 bar. Higher pressure is better because it allows you to keep the vaporizer temperature higher without boiling the incoming liquid. Second, let s set your inlet temperature, or the temperature of your vaporizer. There are two objectives. First, the temperature must be low enough that when the sample enters the vaporizer it is entirely a liquid and isn t bubbling. In Figure 2, the bubble point at 4 bar is 88 C, but we want to build in a cushion, so let s choose 80 C, a round number far enough away from 88 C to be safe. The second objective is that the temperature must be high enough to contribute to the complete flashing of the sample, ensuring that only vapor leaves the vaporizer. When you vaporize the sample, the temperature drops, in accordance with the laws of energy conservation. The sample temperature must be high enough at the outset so that after the pressure drop, the sample is not in the boiling range or no-go zone. In Figure 2, the vapor temperature after the pressure drop is 60 C, just on the vapor side of the dew point line Third, let s set the outlet pressure at the vaporizer. Your objective is to drop the pressure below the gold dew point line. In Figure 2, the outlet pressure is set to 1.5 bar. If the outlet pressure were any higher in this example, the sample would not vaporize entirely. It would fractionate. Fourth, set your flow. Flow is set downstream at a valve and rotameter, not at the vaporizer. In a sampling system, high vapor flow is desirable because it moves the sample to the analyzer faster. However, high flow can be problematic, too, because with high flow, more heat is required to vaporize the sample. In other words, high flow results in a greater drop in temperature at the time of vaporization. In Figure 2, the purple line illustrates the temperature drop. As flow increases, the purple line angles more sharply to the left. Another variable influencing the temperature drop is the heat transfer capability of the vaporizer. Some vaporizers are constructed in such a way that heat transfers more efficiently to the sample. When the liquid sample converts to a vapor and its temperature drops, it draws heat from the stainless steel surrounding it. The critical question is how efficiently can the vaporizer replace that heat and keep it flowing to the sample. The more heat the sample can draw, the less its temperature drops during vaporization. In some instances, it is possible for the vaporizer to be hot to the touch on the outside but cold at the core inside. That s because the vaporized sample is drawing lots of heat and the vaporizer cannot transfer enough heat to keep up. The best solution is to reduce the flow. In sum, the angle of the purple line in Figure 2 is a product of the flow rate and the heat transfer capability of the vaporizer. With a good vaporizer and low flow, the line will become more vertical. Unfortunately, there is no easy way to calculate the location of the purple line, and it is not generated by any known software program. As a result, vaporization involves some approximation. As a rule of thumb, keep the flow rate as low as possible without causing an unacceptable delay in the sample s travel time to the analyzer. It s better to start with a low flow rate and experiment with increasing it than to start with a higher flow rate. 3.

Troubleshooting Phase diagrams will enable you to approximate temperature, pressure, and flow settings, but some troubleshooting will still be required. One sure indication of a problem is poor repeatability in analyzer results. There are two possibilities when the sample is fractionating instead of vaporizing, with Problem #1 being the more common: Problem #1: Only part of the sample is being vaporized. Liquid is passing through the vaporizer and sitting in the tubing on the downstream side. Eventually, it evaporates. When it does, it draws heat from the surrounding tubing, making the tubing cold to the touch or causing frost or ice to form. Indicators: Vaporizer outlet and downstream tubing is cold to the touch or has frost or ice on it. (Note that in many cases, liquid on the downstream side of the vaporizer may pass beyond the area of the vaporizer and into other components, such as flowmeters and filters, where it can cause considerable damage.) Solution: In the approach above, your best option would be to reduce the flow rate. Another option would be to lower the vaporizer outlet pressure, if that is possible. A third option would be to increase the heat to the vaporizer, but in this case you risk causing Problem #2 (see below). Problem #2: The sample is boiling at the inlet to the vaporizer. It is fractionating before it can be vaporized. Lighter molecules evaporate and produce a large cloud of vapor molecules. Some of these lighter molecules move on to the analyzer, giving an inaccurate analysis. The remainder create a vapor wall, which pushes the liquid back into the process. A portion of that vapor wall then cools and condenses. Finally, the liquid sample moves again toward the vaporizer, where the lighter molecules evaporate, starting the cycle all over again. Eventually, the heavier molecules reach the vaporizer and move on toward the analyzer giving an entirely different analysis. This cyclical fractionation process causes the measurement values to oscillate. Indicators: The inlet tube to the vaporizer twitches, sometimes violently, and the measurement values oscillate with the light component cycles out of phase with the heavy ones. Solution: Lower the vaporizer temperature. Conclusion Vaporizing a liquid sample is challenging. In many sampling systems around the world, vaporizers are fractionating samples and sending unrepresentative samples to the analyzer every minute of every day. You can dramatically increase your chances of success by researching a phase diagram of your system s particular mixture of compounds. You can further increase your chances of success by understanding what is occurring in the process specifically, by knowing what the variables are (temperature, pressure, and flow) and their role in influencing the process outcome. With this framework in place, you can reach the right settings, making adjustments in accordance with the signs and symptoms you observe. Resource For more information, see the Swagelok book Industrial Sampling Systems (2013), the definitive sampling systems reference guide by expert Tony Waters. 4.

Author Biographies Dean Slejko is product manager for analytical instrumentation for Swagelok Company, focusing on advancing the company s solutions and services in sample handling system applications. Prior to joining Swagelok, Dean held market and product management positions involving solutions for process control, power management, and utility metering applications. Dean earned a bachelor of science in environmental engineering and a master s degree in business administration from Case Western Reserve University and is a licensed professional engineer in the state of Ohio. Tony Waters has 45 years experience with process analyzers and their sampling systems. He has worked in engineering and marketing roles for an analyzer manufacturer, an end-user, and a systems integrator. He founded three companies to provide specialized analyzer services to the process industries and is an expert in the application of process analyzers in refineries and chemical plants. Waters is particularly well known for process analyzer training courses that he has presented in many of the countries of Asia, Europe, and the Middle East, as well as North and South America. His presentations are always popular and have equal appeal to engineers and maintenance technicians. 2017 Swagelok Company, CORP-0148-05 5.