Atlantic County Tender Task Force B Bravo Division When Atlantic County Tender Task Force B is required the following procedure should be followed:

Similar documents
The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Chapter 14 Water Shuttle Operations

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

Water Supply for Suburban and Rural Firefighting

Galva Fire Department SOP

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

Wilton Fire Protection District. TRAINING DIVISION New apparatus

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

KILGORE FIRE DEPARTMENT

Apparatus Operator Refresher Training Program

TurboDraft Fire Eductor

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Varying pump capacity affects the required hoseline diameter

2017 Volunteer Week - Course Descriptions

Driver Operator Pumps: Basic Pump Operations

Safe Working On Roads Standard Operating Procedures

San Ramon Valley Fire Protection District

Standard Operating Procedures S.O.P. Sample Template Drafted by: Oklahoma State Firefighters Association Educational Advisory Committee

Cedarville Township Volunteer Fire Department Fire Department Standard Operating Guidelines 2008

Cozumel Turbodraft. Operational Considerations

COVINGTON POLICE DEPARTMENT STANDARD OPERATING PROCEDURE

TurboDraft. Fire Eductor Operating Instructions.

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Idaho Fire Service Technology Fire Fighter II

TRAFFIC ACCIDENT STUDY GUIDE 2003

Township Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines TWO IN TWO OUT

Fire Apparatus Operator: ARFF

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

ICE and WATER RESCUE

Snohomish County Fire Chiefs Association Document #

Emergency Action Plan Alaska Marine Lines/Seattle [3/1/10]

T.A.S.A.R. STANDARD OPERATING GUIDELINES

APPROVED BY: On Original EFFECTIVE DATE: September 14 th 2009

ALAMEDA COUNTY FIRE CHIEFS ASSOCIATION

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

WATER RESCUE RESPONSE SOG

FL AGGER S HANDBOOK January 2012

Fire Apparatus Operator: Pumper

STANDARD OPERATING GUIDELINE

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010

Essentials of Fire Fighting

Introduction to Emergency Response & Contingency Planning

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

SUBJECT: RAPID INTERVENTION CREW (RIC) SOG DATE ADOPTED: OCTOBER 18, 2012 REVISED: PAGES: 7

Watson Chapel School District. School Bus Safety Plan

FIRE CHIEF S ASSOCIATION OF BROWARD COUNTY

Checklist For Planning And Conducting The LSA Materials (Class 7-Radioactive) Emergency Response Drill

Fire Apparatus Operator: Pumper

HAZARDOUS MATERIALS SOGS

Core Elements of a Roadway Incident Safety Program

Yakima County Fire District 12 Standard Operating Guidelines SOG 5-1 Hazardous Materials Operations

TYPE OF ORDER NUMBER/SERIES ISSUE DATE EFFECTIVE DATE General Order /12/2015 6/14/2015

Southwest Florida Local Emergency Planning Committee (SWF LEPC) Hazardous Materials Response in Rural Areas Standard Operating Procedures (SOP)

PBCFR Reserve Battalion Combat Skills Check Off

SUN PEAKS FIRE RESCUE

Bruce Rossmeyer s Destination Daytona Motorcycle Skills Challenge Official Rules (ver.1/4/2018)

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019

COMPANY MEMBERS: All privates, engineers, lieutenants, and captains who are assigned to fire and/or rescue companies.

In addition, all personnel assigned to the Field Operations Division will be trained and prepared to support this effort.

PHILADELPHIA FIRE DEPARTMENT OPERATIONAL PROCEDURE # 38 DECEMBER, 2001

North Carolina Fire and Rescue Commission Live Fire Audit Form

Fire Apparatus Operator (FAO)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Division 09 Special Operations. Chapter 01 Technical Rescue Services February 2009

Accident Investigation (Part 2) Training Who is to be Trained

Lisle-Woodridge Fire District Trench Rescue STANDARD OPERATING GUIDELINES

INCIDENT MANAGEMENT SYSTEM AND TACTICAL OPERATIONS MANUAL

Number of Pages: 13 SOG Number: 1-13

School Crossing Guard. S.A.I.S.D. Office of Safety, Security, & Compliance

UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to:

Essentials of Fire Fighting 6 th Edition Firefighter I

DISCLAIMER TSS is simply providing current information so you can make sound tactical decisions.

Standard Operating Guidelines: Swift Water Rescue Operations

Potable Water Truck Safe Work Procedure PTES_HSE_SWP_041. Name Date Signature. Author Geoff Selfe 25/01/2016. Reviewed Solomon Site 25/01/

CONTROL OF HAZARDOUS ENERGY IN THE WORKPLACE

CIRCULAR NO. O-13. Recommended Practices for Manual Protection of Highway/Railway Grade Crossings

FIRE FIGHTER II JPR: FFII-1A

Bowie Police Department - General Orders

Helicopter Operations

POINT PLEASANT BEACH FIRE DEPARTMENT. Firefighter Assistance Search Team (F.A.S.T.) Standard Operating Guideline

Town of Berwick Maine. Request for Proposal Ambulance Services. July 1, June 30, 2014

Scope: This applies to all members of New Kent Fire-Rescue

Engine Compan. pany y Operations. Firefighting and Emergency Operations Volume I - General Firefighting Procedures Book 2 Issued November 2003

A PARTIAL GUIDE TO MCFRS SAFE STRUCTURAL FIREFIGHTING POLICY. Section II Rapid Intervention

Title- FIREFIGHTER ASSIST AND SEARCH TEAM POLICY

Evaluating 2-1/2 Direct Fill Lines Colton, New York

Probationary Firefighter Curriculum

Volunteer Firefighter Applicant Information Package

Ice Rescue. SECTION/TOPIC: Special Rescue Operations REVISED DATE: APPROVED BY: Approver. These SOPs/SOGs are based on FEMA guidelines FA-197

Chapter 1 FF I Orientation and Fire Service History

Manchester Twp. Police

AED Program 2017 January 2017

CITY OF CHICAGO FIRE DEPARTMENT FIRE ENGINEER PROMOTIONAL PROCESS STUDY GUIDE UPDATE FOR THE PROFICIENCY TEST

Probationary Firefighter Orientation Curriculum Will Review:

ENGINE 260 REVISED

Transcription:

Atlantic County Tender Task Force B Bravo Division When Atlantic County Tender Task Force B is required the following procedure should be followed: Notify District 25 Atlantic County Sheriff s Department 609-909-7200 District 25 will then activate Field Comm. 25 and the Fire Coordinators via text message. Then District 25 will call the districts listed below for them to activate the respective participants. Obtain from Caller the following: Location where Tender Task Force B is to report. Type of Incident or situation. Name and Radio call ID of requesting Incident Commander. District 18 Hamilton Township for the following: 609-625-2700 Station 18-2 Mizpah for Tender 18-27 Station 18-4 Weymouth for Tender 18-49 Engine 18-4 District 9 Hammonton 609-561-4000 Station 9 Hammonton # 2 for Tender 9 and Engine 9-5 Gloucester County Dispatch Center 856-694-0911 Station 12-3 Collings Lakes for Tender 12-34 and Engine 12-32 Station 12-1 Richland for Engine 12-1 Station 12-6 Newtonville for Engine 12-66 Station 12-2 East Vineland for Tender 12-22 and Engine 12-23 Station 11-2 Minotola for Engine 11-21 Station 11-1 Landisville for Tender 11-15 and Engine 11-11 Station 31-1 Folsom for Tender 31-16 Station 12-5 Estell Manor for Tender 12-5 Station 12-7 Dorothy for Tender 12-72 Station 43-5 Forest Grove for Engine 43-52 and Tender 43-54 Station 43-4 Malaga for Tender 43-42 Station 43-2 Janvier for Tender 43-21 Station 43-3 Starcross for Tender 43-31 Station 29-5 Cecil for Tender 29-54 and Engine 29-52 29-5 Fire Police District 43 Fire Police

Fire Coordinator - Dennis Kappler 856-307-7100 01/04/2010 rev.2 Page 1 of 4 Atlantic County Tender Task Force B Bravo Division (continued) Camden County Dispatch 856-784-6660 X3 Station 25-9 Winslow Twp. Tenders Station 25-8 Station 25-1 Fire Coordinator - William Shaeffer 856-783-4808 Cumberland County Dispatch 856-455-9515 Vineland Sta # 5 Cumberland County Fire Police Fire Coordinator - 856-265-4847 Salem County Dispatch 856-358-8881 Station 22 Willow Grove for two Tenders 22-5a 22-5b Fire Coordinator - John N. Turner 856-769-3500 Shore Regional Fire Coordinator - Craig Augustoni (Cell) 609-475-5328 Delaware Regional Coordinator - Mike Gallagher 609-324-7410

01/04/2010 rev.2 Page 2 of 4 Atlantic County Tender Task Force B Bravo Division ( Continued ) After all activations have been completed, check with County Fire Coordinator or Deputy Fire Coordinator for Cover up assignments. It is the duty of the Incident Commander in charge to designate a predetermined water source. This can be a hydrant system, well or drafting source. All personnel MUST stay with their apparatus at the staging area and wait for an assignment from the Tender Task Force Leader. Radio Communications: Radio transmissions will be kept to a minimum. Fire Departments will respond using your fire company Fire Channel. Switch to Atlantic County Fire Channel South Jersey Net enroute. All operations will be on South Jersey Net unless changed by the Task Force Leader or Incident Commander. Task Force Leader: The Tender Task Force Leader will direct all operations by utilizing Deputy Task Force Leaders and company leaders at strategic locations, to direct that part of the operation. The Company Task Force Leaders shall report to the staging area upon arrival for updates and instructions. Personnel: It is suggested that the number of personnel, per apparatus, be governed by the S.O.P s of the responding department. It is extremely important that the pump operators remain at the pump operators position at all times, and be fully aware of all facets of the operation. When moving large volumes of water, there are certain risks that we have to be watchful for and would required quick response on the part of the operator. All personnel MUST stay with their apparatus at the staging area and wait for an assignment from the Tender Task Force Leader.

01/04/2010 rev.2 Page 3 of 4 Atlantic County Tender Task Force B Bravo Division ( Continued ) Chief Fire Coordinator Edward Vincent 2502 (Cell) 609-839-1584 Deputy Fire Coordinator Advisor Rickey Coraluzzo- F-2523 (Home) 856-697-1896 (Cell) 856-207-5456 Shore Regional Fire Coordinator Craig Augustoni (Cell) 609-475-5328 TENDER TASK FORCE COMMANDER Bill Collins F-2563 Collings Lakes 609-780-3935 DEPUTY TENDER TASK FORCE COMMANDER Mike Ruberton F-2564 Hammonton Danny Santos F-2565 Weymouth STAGING OFFICERS Chris Jones Landisville Mark Corgiglia East Vineland Brad Ruggeri East Vineland Andy Belone Forest Grove Rick Sepe Hammonton

01/04/2010 rev.2 Page 4 of 4 Atlantic County Tender Task Force (B) (SOG s) I. Purpose and Intent A. A fire officer undertakes the responsibility of protecting lives and property in their community. It is the intent of the Tender Task Force (TTF) Guidelines to make the job as easy as possible. B. When the TTF is requested, their job is to deliver a minimum of 1000 gallons per minute (GPM) of water in the quickest and safest way possible by obeying all motor vehicle laws. It is very important that all apparatus in the operation be able to adapt with each other II. Scope A. This guideline applies to all emergency agencies operating with in Atlanic County that have a need to request a water tender task force B. It is the intent of this guideline to ensure compliance with the National Incident Management System (NIMS). Standard terminology, strike team components, and other resources are identified using NIMS guidelines. III. Standard Operating Guidelines A. When an Incident Commander arrives on or is confronted with a fast moving fire and they feel that their local response or water system will not be sufficient, a call to Communications will activate the first alarm from the TTF. B. When the TTF is dispatched, it will respond with two qualified Water Supply Group Supervisors (WSG). Once the qualified WSG's arrives he/she will be appointed by Command as the WSG. He/she shall be identified by wearing a vest stating Water Supply. The second qualified WSG will be the Portable Pond Unit Leader (PPL). He/she will be identified by wearing a reflective vest stating Portable Pond. C. The WSG must decide where the portable pond operation will be set up in relationship to the fire grounds. The water supply point is the unloading point

for the tankers and the point at which water is supplied to the fire grounds. This point must get set up away from the fire grounds where equipment, including the tenders, can flow freely in and out of the fire scene. D. The object of establishing a Water Supply Point is to better utilize and control all incoming tenders and still allow maximum water flow. E. It may be necessary to move some tenders to the fire grounds to supply the scene while the operation is being set up. This way the fire ground does not run out of water. Once the operation is set up and water is flowing to the fire ground, the tender(s) that was supplying the scene can break down and enter the water shuttle. F. The flow required on the fire ground will be determined by the size of hose that was laid into the scene. This will determine how the WSG has to set up the operation. IV. Procedure A. The following basic procedures are common to all TTF operations and should be understood and practiced. 1. Tenders: a. When a full-scale operation is not needed, a supply tender can be used to supply the fire scene. Incoming tenders can unload their water through supply lines from the supply tender. This tender will have a pump size no smaller then 750 GPM. b. When a full-scale operation is needed, the first due tender with a portable pond should drop off the pond and all loose equipment (see Sect.8) and help set up the pond. It also might be necessary for the second and third tender to do the same. The WSG will determine where the ponds will be set up. Once the ponds are set up, tenders can start unloading by using their dump valves which should be 8 or larger. c. After unloading in the pond, the tender will then proceed to the designated refill point(s). When the shuttle loop has multiple refill points, the following system should be utilized: (1) Empty tenders should always stop at the first refill point unless waved around.

2. Nurse Tenders (2) Tender drivers should stop if they can be loaded immediately by one of the two sets of refill lines or if their tender is the first in line behind the two filling tenders. (3) If these conditions do not exist, the tenders should move on to refill point two. a. A nurse tender can be used two different ways. The nurse tender can be setup away from the portable ponds to supply the pond operation when the ponds become low. The nurse tender can also be setup between the ponds and the fire grounds and be used to supply the fire grounds directly while being filled by the pond. B. Refill Points 1. It is extremely important that refill points be established immediately. Command should give these points. If the WSG knows the area, he/she should pick the closest refill point to the area. Ideally, refill points should be set up on the same traffic routes. 2. When setting up refill points, the first one in the loop will be called Refill Point One and the next one Refill Point Two. 3. Refill Engine: a b The refill engine will have at least a 1250 gpm pump. The engine is required to have at least 30 of hard suction. Enough sections should be used to allow for dropping water levels over the length of the operation. c. Required to have at least 400 of either 3 or 2 1/2 or a combination of each and a floating dock. d. Two lines will be stretched to the front of the engine and two to the rear. e. Once the water supply has been established the WSG shall be notified. f. When refilling has started, the crew of the engine will make all connections to the tenders. The tender driver and/or officer shall remain in the tanker. g. Only one tender will be filled at a time. The second may be hooked up and be ready to be filled as soon as the other tender is filled.

4. Refill Engine With A Manifold a. In some cases it might be necessary for the refill point to be off the roadway or a distance from the loop. b. Drop the manifold with 300 of 3 or 2 ½ hose. Hook up two 50 sections and two 100 sections to four different discharges of the manifold. Leave a crewmember with the manifold with a portable radio. c. Lay a LDH line from the manifold into the draft point. Supply the manifold by connecting directly to a LDH discharge or by using a clapper valve. d. Once the refill engine establishes a water supply, that engine will communicate with the crewmember at the manifold to send the water and bleed off the air from the LDH. C. Pond Operations

1. Supply Engine a. The supply engine will have at least a 1250 gpm pump and carry a low level strainer (pond sucker). This engine will draft out of the main supply pond using the side suction. When a large amount of water is needed, both front and side suctions will be used. b. When connecting to the supply line, a clapper valve (3 to 1) must be used to connect to the supply line that was laid to the scene. 2. Transfer Engine a. The transfer engine will have a least a 1000 gpm pump. b. This engine will draft from the main pond while moving water from the transfer ponds to the main pond. This will de done using a jet transfer fitting connected to a section of hard suction and two 1 ½ or 1 ¾ hand lines. c. The hard suctions are placed between the transfer pond (s) and the supply pond with the jet transfer fitting in the transfer pond (s). The hard suctions will be tied down to eliminate fluctuations in the hose. d. When a tender is unloading, this is the pond that you will be transferring water out of to the supply pond. This will help eliminate a tender backup at the pond operation

D. Staging: V. Responsibilities 1. There should be at least two engine companies in staging during the operations. These engines could be used to replace an engine that might breakdown, supply a nurse tender, operate in the shuttle, etc. A. Water Supply Group Supervisor (WSG): 1. Determine if a full-scale operation is needed or if a supply tender can handle the operation. 2. Placement of the equipment 3. Additional equipment needed to supplement the tender operation. 4. Establish refill points 5. Determine need for fire police B. Portable Pond Unit Leader (PPL): 1. Assist WSG in setting up his/her operation 2. Set up safety cones 3. Assign tanker spotter 4. Monitor tanker unloading 5. Maintain record of total gallons unloaded 6. Keeps communication with the WSG

C. Refill Unit Leader: 1. Establish control and monitor refill operations 2. Request additional equipment 3. Monitors flow of empty tenders so there is no backlog at their point. 4. Keeps communication with the WSG D. Staging Area Manager: 1. In charge of all apparatus in Level II staging. 2. Position apparatus so that any unit can immediately be released to its assignment. E. Drivers: 1. Must know and understand the operating principles and procedures of this guideline. 2. Must operate their apparatus in a safe manner by obeying all speed limits. 3. Monitor radio for instructions and use SJ net 154.265 4. When in staging, listen to the Staging Area Manager for assignments. VI. Dispatching Guidelines A. Apparatus will be dispatched using the term TTF Assignment. B. Apparatus on the first alarm will be dispatched to the fire ground unless otherwise indicated by the IC. C. Cover assignments will be dispatched automatically unless an officer requests that his/her station not be covered. D. The Atlantic County Fire Coordinator shall be notified on the first alarm of the TTF. E. The Atlantic County Fire Police shall be dispatched on the Second Alarm. VII. Radio Guidelines A. Radio traffic must be kept to an absolute minimum. If directions are needed, this should be done via telephone prior to leaving the station. B. Apparatus responding to the fire grounds, staging area, or cover assignment will switch their radios to a designated channel as directed by Central Communications.

VIII. Personal Safety Guideline A. Personal safety of the firefighters at a TTF operation is of primary importance. B. Firefighters are required to bring approved personal protection equipment during a TTF Operation. C. Each apparatus responding should have a crew size no more than equal to the seating capability. D. Each officer and firefighter responding must use an approved accountability procedure. E. If an apparatus must leave the incident for any reason, a head count must be taken. F. Apparatus will be responding from all parts of Atlantic and other Counties. Chiefs and apparatus operators must consider their apparatus is traveling in an area that is out of their normal coverage area. Different and unfamiliar roads and confused motorists increase our exposure for a problem. Every apparatus operator must use extreme caution during his/her response. Responding and arriving safely with your crew is very important. G. All firefighters committed to an operation must stay within that particular operation. IX. Apparatus Guidelines A. Apparatus needed for a TTF Operation are: X. Equipment 1. Tenders with at least 2500 gallons of water. 2. Engines with l250 gpm pumps or greater to be able to draft, supply or refill. 3. Nurse Tenders 4. Transfer Engines with at least 1000 gpm pumps. 5. The unit ID. number will be placed on the front bumper. 6. Apparatus should have a minimal restriction on maneuverability. A. The following equipment is recommended for this operation: 1. Tenders: a. 4 1/2" NST hydrant adaptor. b. Rear Dump with an 8" minimum discharge. c. Side Dumps d. Portable Pond (minimum of 3000 gal.). e. Number signs for portable ponds ex. 1, 2, and 3. f. Vests with WATER SUPPLY and Portable Pond Unit Leader. g. 6" Low Level Strainer

h. Jet Transfer Fitting (s) i. Wheel Chocks j. Safety Cones 2. Engines: a. Adaptors to 4 1/2", 5", and 6". b. 400 of 2 ½ or 3"hose. c. Hard Suction (30') d. Floating Dock e. Manifold w/4 discharges f. Wheel Chocks g. Safety Cones B. Companies dropping ponds should place all loose equipment next to their pond. C. All equipment should have the company's name or identifying number on it. XI. Terminology Guidelines A. Portable Pond(s): Are portable reservoirs, (of at least 3000 gal.) and are used when a full-scale operation is needed. Incoming tenders unload their water through dump valves. This water is then sent to the fire ground by either a supply engine or to a nurse tender then sent to the fire ground. B. Portable Pond Unit Leader: Assists the Water Supply Group Supervisor in setting up the operation. He/she also sets up safety cones, assigns tender spotters, monitors the tender unloading, and maintains records of the total gallons unloaded. C. Refill Engine: Is an engine with at least a 1250 gpm pump to draft or hookup to a water supply to fill tenders. D. Refill Point: Is the location where tenders are sent when they are empty to refill. This water supply can be from drafting out of lakes, streams, ponds, dry hydrants, municipal hydrants, or basically from any water source available. E. Staging Area Manager: Monitors the staging areas and keeps a list of equipment that is in staging. He/she also positions apparatus so they can move in and out freely. F. Supply Engine: Is an engine of at least 1250 gpm to draft out of the portable ponds to supply the fire grounds. G. Supply Pond: This is the main portable pond that a supply engine drafts from to supply the fire grounds. H. Supply Tender: Is a tender with a pump size no smaller then 750 gpm. This tender is used when a full-scale operation is not needed. Incoming tenders unload their water through discharge lines that hook--up directly to the supply tenders rear intakes.

XII. I. Tender: Is an apparatus capable of holding at least 2500 gallons of water. J. Transfer Engine: Is an engine of 1000 gpm or more to transfer water from the transfer pond(s) to the supply pond. K. Transfer Pond: Are ponds where tenders unload their water. These ponds provide water for the supply pond. L. Water Supply Group Supervisor (WSG): Is in charge of all water supplied to the fire grounds. He/she determines if additional equipment is needed. Also establishes refill points. Closing A. All fire departments in Atlantic County shall receive a copy of this plan. All Chief Officers shall become familiar with this plan. B. Any plan previously published that is in conflict with this plan is hereby rescinded. ASSESTS: All tenders within the County having a minimum capacity of 2500 gallons of water. Accountability Tags for your Apparatus Tenders Blue Engines Red with pump size and tank size Accountability Roll Call Sheet with all member on scene NOTE: All tenders are to be equipped as outlined in the Tender Task Force guidelines as published by the Atlantic County Fire Chief s Association. Any Question Contact Bill Collins F- 2563 Nextel 168*71*46446 609 780 3935 Rev2 01/04/2010. Any plan previously published that is in conflict with this plan is hereby rescinded.