NOVA 3 INSTRUCTION MANUAL

Similar documents
Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3 RESPIRATOR COMPONENT CONCEPT 4

NIOSH CAUTIONS & LIMITATIONS 3 WARNINGS 4 INTRODUCTION 6 RESPIRATORY OPERATION 6 RESPIRATOR COMPONENT CONCEPT 8

LIGHTWEIGHT ABRASIVE BLASTING HELMET INSTRUCTION MANUAL

EN14594: 2005 INSTRUCTION MANUAL

NIOSH - CAUTIONS AND LIMITATIONS 3 INTRODUCTION 4 RESPIRATORY COMPONENT CONCEPT 5 !WARNINGS! 6 RESPIRATOR OPERATION 8

INSTRUCTION MANUAL. Doc. no. MN4007E Rev. B - Oct NOVA 1 Abrasive Blasting Helmet 0194 EN14594: Surface Treatment Solutions

Z100 SERIES INSTRUCTION MANUAL

CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference.

Astro Sandblast Helmet

The ultimate protection & future-proofed performance

NOVA 2000 INSTRUCTION MANUAL PROTECTING YOU FOR LIFE S BEST MOMENTS

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

Z3 WELDER INSTRUCTION MANUAL

Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3 RESPIRATORY COMPONENT CONCEPT 4

C40 CLIMATE CONTROL INSTRUCTION MANUAL PROTECTING YOU FOR LIFE S BEST MOMENTS

COLD AIR TUBE INSTRUCTION MANUAL PROTECTING YOU FOR LIFE S BEST MOMENTS

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

ASTRO SANDBLAST HELMET

!warnings! 4. RPB and Advancing Your Safety are registered trademarks of RPB Safety.

INSTRUCTION MANUAL. Nova Blast Helmet IMPORTANT WARNING FOR SAFER BLAST CLEANING

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

ALLEGRO INDUSTRIES SERIES 9910 (LP) CONTINUOUS FLOW, SUPPLIED AIR HOOD RESPIRATORS P/N 9910 P/N 9910R P/N 9910D P/N 9910DS P/N 9912D

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Respiratory Protection. Program

The ultimate powered air purifying respirator

The ultimate gas detection monitor

Important: Keep these instructions for reference.

Phalanx Alpha Phalanx Beta and Ultra Elite

TITAN II RESPIRATOR HELMET

AIRBLAST CLIMATE CONTROL TUBE

Checklist for care of Respirators

AIR INLINE METAL SHEAR

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Model ASSEMBLY and OPERATING INSTRUCTIONS

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

MB30 Series Airline Respirator User Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

GenVX Series Airline Respirator User Manual

CLEMCO SUPPLIED AIR RESPIRATOR MODEL 60 HP O.M

(MPV-625) 8 AIR SUPPLIED RESPIRATOR

88VX TM Series Airline Respirator

Head Cover BE-12 Series

PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION

RPB ABRASIVE BLASTING RANGE

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

A. Evaluation of the written program

photo coming soon Product Family Respiratory Replacement Parts Canada (English) Page 1 of 17 Product Numbers & Ordering Information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Hoods R-Series User Instructions for 3M TM Hoods and and 3M TM Hood , Butyl Rubber

GenVX TM Series Airline Respirator User Manual

Respiratory Protection Self-Inspection Checklist

photo coming soon Product Family Respiratory Replacement Parts Corporate - English Page 1 of 23 Product Numbers & Ordering Information

Respiratory Protection Self Inspection Checklist

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

USER S MANUAL For CONTINUOUS FLOW, LOOSE FITTING SUPPLIED AIR SHIELD RESPIRATORS P/N 9903-D P/N 9903-CV P/N 9903-C P/N 9903-HC (TC# 19C-468)

Personal Protective Equipment 29 CFR 1926

SOTR Special Operations Tactical Respirator

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

CS150 CAP STAPLER OWNER S MANUAL

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

University of Dayton Respiratory Protection Program 29 CFR

Fire Escape Hood OPERATION AND INSTRUCTIONS

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

AIRLINE-SERIES HELMET AIR FILTER

HEALTH AND SAFETY MANUAL

Features. Description

SANDBLAST HELMET EXTREME

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

User Manual 0194 EN 270. Table of Contents. Warning

Portable Compressed CO 2 Regulator

Vortex Tube Respirator

Advantage 4000 Abrasi-Blast Respirator

Dual Airline Supplied Air Respirators User Instructions

Respiratory Protection

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Yoke Block Instruction Manual

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

"RESPIRATORY PROTECTION AND SAFETY"

PERSONAL AIR BREATHING UNIT

PRODUCT OPERATING MANUAL

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

3/8" Dr. Air Butterfly Impact Wrench

75 Years of Health and Safety Guidance

Operating Manual. Model BAC-30RT30/BAC-30DC

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

INTENDED USE TECHNICAL SPECIFICATIONS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

Yoke Block Instruction Manual

IMPORTANT SAFETY INFORMATION

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Transcription:

NOVA 3 INSTRUCTION MANUAL

CONTENTS INTRODUCTION 4 RESPIRATOR COMPONENT CONCEPT 5 WARNINGS 6 NIOSH CAUTIONS & LIMITATIONS 8 RESPIRATORY OPERATION 9 SPECIAL OR CRITICAL USER INSTRUCTIONS - BREATHING AIR PRESSURE TABLE 0 RESPIRATOR SETUP AND USE INSPECTION, MAINTENANCE, CLEANING & STORAGE 6 PARTS AND ACCESSORIES 20 APPENDIX A 25 Read all instructions and warnings before using this product. Keep this manual for future reference. RPB Safety Global Headquarters 2807 Samoset Rd, Royal Oak, MI 48073, USA. T: -866-494-4599 F: -866-494-4509 E: sales.us@rpbsafety.com rpbsafety.com RPB Safety Asia Pacific Headquarters 652 Halswell Junction Road, Hornby South 8042 New Zealand. T: +64-3-357-76 F: +64-3-357-763 E: sales.nz@rpbsafety.com rpbsafety.com RPB, Advancing Your Safety, Nova, Nova 3, Radex, Zytec, Z-LINK and T-LINK are registered trademarks of RPB Safety LLC For technical assistance contact our Customer Service Department at -866-494-4599 or email: customerservice@rpbsafety.com FORM #: RPB 55 REV: 9 3

NOVA 3 INTRODUCTION The RPB NOVA 3 Respirator is approved by NIOSH as follows: Type CE Supplied Air Respirator - When used with RPB Supplied AIr Hose and Flow Device System. This provides respiratory protection during abrasive blasting. The RPB NOVA 3 Supplied Air Respirators are designed to provide protection from airborne contaminants in atmospheres NOT IMMEDIATELY DANGEROUS TO LIFE OR HEALTH, and from which a user can escape without the aid of the respirator, or that do not exceed concentrations allowed by OSHA, EPA or NIOSH regulations and recommendations. WARRANTY All RPB Safety products are covered by a manufactures warranty of 3 months. The manufacturer warranty covers defects in material, workmanship and does not cover damage caused by misuse or abuse. RPB Safety s only obligation and your exclusive remedy shall be to repair, replace or refund the purchase price of such parts or products upon the presentation of proof of purchase. Maximum liability is in no case to exceed the value of the RPB Safety Product involved. The helmet meets ANSI Z89. Type C Head Protection and the Inner Lens meets ANSI Z87. for Eye Protection. The cape is designed to protect the wearer s upper body from rebounding abrasive. RPB NOVA 3 Respirators are NIOSH Approved for use with the following devices: NV206 Flow Control Valve 4000-0 Cold Air Tube 4000-20 Hot Air Tube 03-500 C40 CLimate Control Tube 4

RESPIRATOR COMPONENT CONCEPT The RPB NOVA 3 Supplied Air Respirator consists of 4 main components, as shown in Fig.. All 4 components must be present and properly assembled to constitute a complete NIOSH Approved Respirator. FIGURE.. Respirator Helmet Assembly 2. Respirator Cape 3. Breathing Tube Assembly 4. Air Supply Hose Assembly or PX4 PAPR!WARNING! Failure to use genuine parts and components that are part of the NIOSH approved respirator assembly will void the approval of the entire respirator assembly. 5

NOVA 3!WARNINGS!. Do not use this respirator until you have been trained in the respirators use, maintenance and limitations by a qualified individual (appointed by your employer) who has extensive knowledge on the RPB NOVA 3 Respirator. All training must be in accordance with this Users Instruction Manual. 2. Before using this respirator ensure your employer has determined that airborne contaminant concentrations do not exceed those allowed by applicable OSHA, EPA or NIOSH regulations and recommendations for continuous flow supplied air respirators. Federal law requires that the employer measures and monitors airborne contaminant levels in the work area. 3. Do not wear this respirator if any of the following conditions exist Atmosphere is immediately dangerous to your life or health You CAN NOT escape without the aid of the respirator Atmosphere contains less than 9.5% oxygen Work area is poorly ventilated Contaminants are in excess of regulations or recommendations 4. Do not modify or alter this respirator. Use only parts and components that are part of the NIOSH approved respirator assembly. The use of non RPB Safety parts voids the NIOSH approval of the entire respirator assembly. 5. Inspect all components of the respirator daily for signs of damage or wear and tear that may reduce the level of protection originally provided. 6. Do not use silica sand or abrasives containing silica, lead, arsenic or sharp glass particles - use of abrasive containing these elements could result in serious injury or death. 7. Do not wear this respirator until you have passed a complete physical exam including a lung X-ray conducted by qualified medical personnel. 8. Improper use of this respirator or use not in accordance with this User Instruction Manual may cause injury or death. Improper use may also cause life threatening delayed lung diseases such as silicosis, pneumoconiosis or asbestosis. 9. This respirator, when properly fitted and used, significantly reduces but does not completely eliminate the breathing of contaminates by the respirator wearer. 0. Be certain your employer has determined that the breathing air source provides at least a Grade D breathable air as specified in the compressed gas association commodity specification G-7.. The respirator must be supplied with clean breathable air at all times. A carbon monoxide monitor must be used at all times. Contact your RPB Safety distributor for a GX4 08-400 Gas Monitor.. RPB Safety cannot accept any liability of whatsoever nature arising directly or indirectly from the use or misuse of RPB Safety products, including purposes that the products are not designed for. RPB Safety is not liable for damage, loss or expense resulting from the failure to give advice or information or the giving of incorrect advice or information, whether or not due to RPB Safety s negligence or 6

that of its employees, agents or subcontractors. 2. Do not connect the respirator s air supply hose to nitrogen, toxic gases, inert gases or other unbreathable non Grade D air sources. Check the air source before using the respirator. This apparatus is not designed for use with mobile air supply systems i.e. cylinders. Failure to connect the supply hose to the proper air source could result in serious injury or death. 3. If this respirator is used in confined spaces ensure the area is well ventilated and that all contaminate concentrations are below those recommended for this respirator. Follow all procedures for confined space entry, operation and exit as defined in applicable regulations and standards. 4. Leave work immediately if: Any respirator component becomes damaged. Airflow stops or slows down Breathing becomes difficult You become dizzy, nauseous, too hot, too cold or ill. Vision is impaired. 5. RPB NOVA 3 Respirators do not provide hearing protection. Earplugs or earmuffs must be properly fitted when exposed to noise levels that exceed the OSHA permissible exposure levels. RECOMMENDATION: When using a RPB NOVA 3 Supplied Air Respirator. It is recommended to use a Radex Airline Filter (04-900) and a GX4 Gas Monitor (08-400) 7

NOVA 3 NIOSH - CAUTIONS AND LIMITATIONS A B C D E F H I J L M N O Not for use in atmospheres containing less than 9.5 percent oxygen. Not for use in atmospheres immediately dangerous to life or health. Do not exceed maximum use concentrations established by regulatory standards Air-line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G-7. Grade D or higher quality. Use only the pressure ranges and hose lengths specified in the user s instructions Do not use powered air-purifying respirators if airflow is less than 4CFM (5lpm) for tight fitting facepieces or 6CFM (70lpm) for hoods and/or helmets. Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridge and canisters are replaced before breakthrough occurs. Contains electrical parts which have not been evaluated as an ignition source in flammable or explosive atmospheres. Failure to properly use and maintain this product could result in injury or death. Follow the manufacturer s User s Instructions for changing cartridges, canister and/or filters All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA, and other applicable regulations. Never substitute, modify, add or omit parts. use only exact replacement parts in the configuration as specified by the manufacturer. Refer to user s instructions, and/or P S maintenance manuals for information on use and maintenance of these respirators. NIOSH does not evaluate respirators for use as surgical masks. Special or critical user s instructions and/or specific limitations apply. Refer to user s Instruction page 9 (breathing air pressure table) before donning. 8

RESPIRATOR OPERATION AIR QUALITY This respirator must be supplied with clean breathable air at all times. Breathable air must at least meet the requirements for Type gaseous air described in the Compressed Gas Association Commodity Specifications G.7. (Grade D or higher) and as specified by Federal Law 42 CFR 84, subpart J.84.4(b) and 29 CFR 90.34 (i) the RPB NOVA 3 does not purify air or filter contaminants. AIR SOURCE Supplied Air Locate the air source in a clean air environment, always use a filter on the inlet of your air source. Do not park vehicles beside your air inlet as this will cause carbon monoxide to be drawn into your air supply. Always use suitable after coolers / dryers with filters and carbon monoxide alarms to ensure clean breathable air is supplied at all times. The air should be regularly sampled to ensure that it meets Grade D requirements. BREATHING AIR SUPPLY HOSES AND FITTINGS RPB air supply hoses and fittings must be used between the point of attachment and the respirator breathing air connection at the wearer s belt. The hose sections must be within the correct length and the amount of sections must be within the number specified in the breathing air pressure table on page 0. BREATHING AIR PRESSURE The air pressure must be continually monitored at the point of attachment. Air pressure must be read from a reliable pressure gauge whilst the respirator has air flowing through it.!warning! Failure to supply the minimum required air pressure at the point of attachment for the length of air supply hose could result in contaminants being inhaled as the pressure in the helmet may become negative due to peak inhalation flow when working at very high work rates. The RPB NOVA 3 Breathing Air Pressure table on page 9 defines the air pressure ranges needed to provide the respirator with a volume of air which falls in the required range of 6-5cfm or 70-425 Its/min.!WARNING! Make sure you understand the Breathing Air Pressure table before using this respirator.. Determine your air source (column ). 2. Identify your breathing tube assembly (column 2). 3. Confirm the part number of the air supply hose you are using (column 3). 4. Check your RPB Safety Air Supply Hose is within the correct length (column 4). 5. Set the air pressure at the point of attachment within the range specified (column 6) for your breathing tube assembly, hose length and number of hose sections (column 5). Make sure air is flowing through your respirator when setting the air pressure. 9

NOVA 3 SPECIAL OR CRITICAL USERS INSTRUCTIONS BREATHING AIR PRESSURE TABLE Figure 2. This table lists air pressure ranges needed to provide the RPB NOVA 3 with the volume of air that falls within the required range of 6-5cfm or 70-425 lts/min according to U.S government regulations.. AIR SOURCE 2. BREATHING TUBE ASSEMBLY AND FLOW CONTROL DEVICES 3. AIR SUPPLY HOSE 4. SUPPLY HOSE LENGTH (FT) 5. MAX NUMBER OF SECTIONS 6. PRESSURE RANGE (PSIG AIR) Portable or Stationary Compressor NV202B/NV206 Flow Control Valve assembly NV2028 (25ft) NV2029 (50ft) NV2027 (00ft) 04-352-25-RZ (25ft) 04-352-50-RZ (50ft) 04-352-00-RZ (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 27-28 28-29 30-3 33-34 36-37 38-39 4-43 Portable or Stationary Compressor NV202B/4000-0 Cold Air Tube Assembly NV2028 (25ft) NV2029 (50ft) NV2027 (00ft) 04-352-25-RZ (25ft) 04-352-50-RZ (50ft) 04-352-00-RZ (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 55-56 56-57 60-62 65-67 70-72 77-78 80-82 Portable or Stationary Compressor NV202B/4000-20 Hot Air Tube Assembly NV2028 (25ft) NV2029 (50ft) NV2027 (00ft) 04-352-25-RZ (25ft) 04-352-50-RZ (50ft) 04-352-00-RZ (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 67-68 69-70 73-74 77-78 8-82 86-87 9-92 Portable or Stationary Compressor NV202B/03-500 Climate Control Assembly NV2028 (25ft) NV2029 (50ft) NV2027 (00ft) 04-352-25-RZ (25ft) 04-352-50-RZ (50ft) 04-352-00-RZ (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 50-80 55-85 60-95 65-95 70-00 75-00 85-00 Note: Please see Appendix A for other hose configurations.!warning! The NOVA 3 Supplied Air Respirator must be supplied with respirable air meeting the requirements of CGA G-7. Grade D or higher quality. 0

RESPIRATOR SETUP AND USE INNER LENS FIGURE 3. FIGURE 3.2 Place RPB Inner lens (NV3-722) into the left of the Inner lens frame (NV3-723) and work it round locating it into the frame and finally clipping it into place on the right. Secure locating Inner lens frame pins into visor latch mount rolling the frame round the inner lens seal and securing it onto the clips at the visor hinge mount. FIGURE 3.3 FIGURE 3.4 TEAR OFF AND OUTER LENSES To remove the Inner lens frame pull frame from the visor hinge mount rolling it round and then dislocate the locating pins from the Visor latch mount. Place 3 Tear Off Lenses (N3-725) and Outer Lens (N3-724) on top of each other, make sure the tabs are folded the same way.

NOVA 3 RESPIRATOR SETUP AND USE CONTINUED TEAROFF AND OUTER LENSES (CONTINUED) FIGURE 3.5 FIGURE 3.6 Place the lenses onto the Lens Locator at the centre of the visor (N3-726). Slide the lenses under the lens locators that are positioned at the sides of the visor. CONNECTING THE AIR SUPPLY FIGURE 3.7 FIGURE 3.8 Thread on the loose running nut of the Breathing Tube (NV202B) on to the Flow Control Device (e.g 03-0). Screw the running nut in a clockwise direction until tight. Connect the Breathing Tube (NV202B) to the Helmet. This end is labelled Attach this end to helmet. Turn anti clockwise until tight. 2

FIGURE 3.9 FIGURE 3.0 Connect the Breathing Air Supply Hose to the point of attachment (04-900 Radex Airline Filter) shown.!warning! Make sure that the air from the point of attachment is Grade D or higher quality and meets OSHA requirements. Now connect the Breathing Air Supply Hose to the Flow Control Device. Air should be now flowing through the Respirator.!WARNING! Check the air pressure at the point of attachment is within the range specified in column 6 of the Breathing Air Pressure Table for the hose length and amount of hose sections. Make sure air is flowing through your respirator when setting the air pressure. 3

NOVA 3 RESPIRATOR SETUP AND USE CONTINUED DONNING YOUR HELMET Once you have set up, you are ready to fit your RPB NOVA 3 Supplied Air Respirator. Firstly check inside the helmet to ensure that it is free of dust, dirt or contaminates. FIGURE 4. FIGURE 4.2 Adjust the Respirator padding size by turning the ratchet knob located under the cape collar at the back of the respirator padding. Fold back cape, open the Inner Bib and place your fingers on the Inner Bib and the side of helmet at approximately ear position. Lift the helmet and place onto your head. Make sure air is flowing into the respirator prior to fitting. FIGURE 4.3 FIGURE 4.4 Pull the Inner Bib around your neck and adjust the elastic cord to ensure a snug fit. This helps provide a barrier to airborne contaminates. Adjust the Respirator Cape around your body and fasten the snap hooks on each side of the cape. 4

FIGURE 4.5 FIGURE 4.6 CLICK Fasten the NV2022 belt at waist or hip level and adjust for comfort. Move the Flow Control Device away from spine. Re check the air pressure and adjust if necessary. With air flow into your respirator you are now ready to enter the work area. DOFFING YOUR HELMET When you have finished working, leave the work area wearing the respirator with air flowing into the helmet. Once outside the contaminated area remove the respirator and disconnect the air supply hose.!warning! NEVER remove your Respirator while you are in the work areas as this may result in serious injury or death. 5

NOVA 3 INSPECTION, MAINTENANCE, CLEANING AND STORAGE As the RPB NOVA 3 Supplied Air Respirator has a limited service life, a regular inspection and replacement programme must be conducted. Before using the Respirator all parts should be inspected for damage or wear and tear. Replace all worn or damaged parts immediately. Use only parts and components that are part of the NIOSH approved respirator assembly. Refer to Parts and Accessories section on pages 20-24 part numbers.!warning! Do not clean this respirator with volatile chemicals. HELMET AND LININGS FIGURE 5. FIGURE 5.2 The side padding is mounted on a hinge and can be removed by pulling away from the helmet. The covers can be removed from the padding and washed in a conventional washing machine or with light detergent and water. 6

FIGURE 5.4 FIGURE 5.3 Remove rear Pad Remove Head Liner padding from the head liner, the padding can be washed or disposed. The padding is secured with hook fasteners. FIGURE 5.5 a FIGURE 5.6 To remove the Head Liner, first remove the 4 clips (a) then lift out. To clean, rinse in a light detergent and water, or place in a conventional washing machine. Do not clean with volatile e chemicals. The inside of the helmet can be wiped clean with a liquid detergent. 7

NOVA 3 INSPECTION, MAINTENANCE, CLEANING AND STORAGE (CONTINUED) LENSES AND LENS GASKETS Check Inner Lens Gasket (NV3-72) and the Inner Lens Frame (NV3-723) for splits, cracks or wear and tear. Replace any damaged or worn parts immediately with RPB Safety genuine parts. The Inner Gasket and Inner Lens fame can be sponged with warm water and a gentle detergent, rinsed and air dried. AIR SUPPLY HOSE The air supply hose should be inspected for cuts, cracks, blisters and signs of abrasion. Make sure the fittings are firmly crimped to the hose and air cannot escape. Make sure the hose has not been crushed or kinked. Replace the hose immediately if there are any signs of damage. Do not run water through the inside of the hose. Clean the Quick Disconnect Couplings with an air blow down gun to remove any sand or dirt that may jam the coupler. BREATHING TUBE ASSEMBLY Inspect the Breathing Tube NV202B for splits or excessive wear. Check that the fitting are secured into the tube and are not allowing any air to escape. Replace the tube as soon as signs of damage or excessive wear become evident. Do not remove the foam that is inside the Breathing Tube as it reduces the noise level of the incoming air.!warning! USE ONLY RPB SAFETY AIR SUPPLY HOSES. VISOR ASSEMBLY FIGURE 5.7 There is an Allen Key mounted in the padding connector. Rotate the Allen Key out of the holder then pull down to remove. 8

FIGURE 5.8 FIGURE 5.9 To remove the Visor, undo the hinge lock (NV3-727-2) and slide back, this will expose the hinge pin to remove the Visor. The Hinge Mount (NV3-727) and Latch Mount (NV3-728) can be removed using the Allen Key. STORAGE FIGURE 5.0 FIGURE 5. After you have used the respirator, hang it up by the hand strap in a clean environment, this will help keep the inside free of contaminants. After the respirator components have been cleaned and inspected, place them in a plastic bag or an airtight container. Store respirator parts away from excessive heat, dust, cold, moisture and harmful chemicals. 9

NOVA 3 PARTS AND ACCESSORIES FIGURE 6. Helmet Components Figure 6.2 Padding System Figure 6.6 Visor and Lenses Figure 6.3 Respirator Capes Figure 6.5 Breathing Tube & Flow Control Devices Figure 6.4 Filtration & Monitoring Please refer to RPB Catalog Air Supply Hose Figure 6.7!WARNING! Use only parts and components that are part of the NIOSH approved respirator assembly. The use of non RPB parts voids the NIOSH approval of the entire respirator assembly. 20

HELMET COMPONENTS Figure 6.2 All kits contain screws and nuts when necessary NV3-727-2 NV3-729 NV3-730 NV3-759 NV3-727/8 NV3-727-2 NV3-727/8 NV3-729 NV3-730 NV3-759 Visor Hinge Lock Visor Latch Mount Kit - Includes: Latch Mount, Hinge Mount, Covers Air Inlet Kit - Includes: Air Inlet, O-Ring, Back Plate, Hanging Strap Padding Connectors (left & right) Cape Coverband VISOR AND LENSES Figure 6.3 All kits contain screws and nuts when necessary NV3-72 NV3-723 NV3-722 NV3-726 NV3-724 NV3-72 Inner Gasket NV3-722 Inner Lens pk 0 NV3-723 Inner Lens Frame NV3-724 Outer Lens pk 50 NV3-725 Tear Off Lens pk 50 NV3-726 Visor Kit - Includes: Visor with Hinge Pin and Latch, Hinge Lock NV3-725 2

NOVA 3 PARTS AND ACCESSORIES CONTINUED BREATHING TUBE & FLOW CONTROL DEVICE Figure 6.4 4000-20 NV206 4000-0 NV202B NV2022 NV202B Breathing Tube (dark grey) NV2022 Belt NV206 Flow Control Valve Assembly - Includes: Flow Control Valve, Belt 4000-0 Cool Air Tube Assembly - Includes: Cool Air Tube, Belt 4000-20 Hot Air Tube Assembly - Includes: Hot Air Tube, Belt 03-500 C40 Climate Control Tube - Includes: C40, Belt 03-500 RESPIRATOR CAPES Figure 6.5 NV202 NV3-755 NV3-752 NV3-753 NV3-754 NV3-750 NV3-75 NV3-750 NV3-75 NV3-752 28 Nylon Cape 38 Nylon Cape 28 Leather Cape NV3-753 NV3-754 NV3-755 38 Leather Cape Blast Jacket Size XL Blast Jacket Size XXL NV202 Inner Bib 22

PADDING SYSTEMS Figure 6.6 NV3-734 07-733 NV3-735- NV3-734- 07-900 NV3-735 07-73 07-732 NV3-73 Side Padding Frames (left & right) NV3-732-XXX Side Padding Foam Pads pk 5 pairs (A0 Thin - A5 Medium - A20 Thick) ** NV3-734 Head Liner Kit - Includes: Head Liner, Head Liner Foam Padding, Head Liner Clips x4 NV3-734- Head Liner Clips, pack of 4 NV3-735 Head Liner Padding NV3-735- Neck Pad 07-900 Adjustable Head Support ** Note that the A0 is for larger head sizes and the A20 is for smaller head sizes. 23

NOVA 3 PARTS AND ACCESSORIES CONTINUED AIR SUPPLY HOSES Figure 6.7 Series. Couplers 2. Plugs RPB Quick Disconnect NV2025 /4 FM NPT 3. Supplied-Air Hose Assemblies NV2028 RPB 25ft NV2029 RPB 50ft NV2027 RPB 00ft RPB RZ Quick Connect 03-052-CB-RZ RZ Coupler 03-052-PB-RZ RZ Plug Hose Tail 03-052-PM-RZ RZ Plug /4 Male Thread 03-052-PMS-RZ RZ Swivel Plug 04-352-25 RZ 25ft 04-352-50 RZ 50ft 04-352-00 RZ 00ft Schrader Twist Lock 03-042-CF /4 FM NPT 03-042-PM /4 M NPT 03-042-PMS /4 M NPT SWIVEL 04-342-25 Schrader 25ft 04-342-50 Schrader 50ft 04-342-00 Schrader 00ft 25ft 50ft 00ft 24

APPENDIX A - SCHRADER AIR PRESSURE TABLE. AIR SOURCE 2. BREATHING TUBE ASSEMBLY AND FLOW CONTROL DEVICES 3. AIR SUPPLY HOSE 4. SUPPLY HOSE LENGTH (FT) 5. MAX NUMBER OF SECTIONS 6. PRESSURE RANGE (PSIG) Portable or Stationary Compressor NV202B/NV206 Flow Control Valve Assembly 04-342-25 (25ft) 04-342-50 (50ft) 04-342-00 (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 28-30 30-32 33-35 36-38 40-42 44-46 48-50 Portable or Stationary Compressor NV202B/4000-0 Climate Control Tube Assembly 04-342-25 (25ft) 04-342-50 (50ft) 04-342-00 (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 60-65 60-65 65-70 70-75 75-80 80-85 85-90 Portable or Stationary Compressor NV202B/4000-20 Climate Control Tube Assembly 04-342-25 (25ft) 04-342-50 (50ft) 04-342-00 (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 70-75 70-75 75-80 80-85 85-90 90-95 95-00 Portable or Stationary Compressor NV202B/03-500 Climate Control Tube Assembly 04-342-25 (25ft) 04-342-50 (50ft) 04-342-00 (00ft) 25 50 00 50 200 250 300 2 3 4 5 6 60-80 65-85 70-95 75-95 80-00 85-00 95-00 25

NOVA 3 NOTES 26

NOTES 27

OTHER PRODUCTS RPB C40 CLIMATE CONTROL Looking for an advanced climate control device that can heat and cool your supplied air just by the slide of a lever? Look no further than the RPB C40. From the searing heat of an Arizona summer to a severe Scandinavian winter the RPB C40 will keep you comfortable. AIRLINE FILTRATION The RPB RADEX AIRLINE FILTER offers increased capacity, versatility and filtration. This optional equipment combines the versatility of either floor or wall mounting with increased filtration capacity, enabling customization to meet worker s needs and working environments. AIR QUALITY MONITORING Do you need an intelligent gas monitor that can give you complete confidence in the air you and your employees are breathing? The RPB GX4 Gas Monitor has the ability to detect up to 4 gases simultaneously, giving you total peace of mind. 866 494 4599 www.rpbsafety.com