DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

Similar documents
DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

Materials : Stainless steel ASTM A351 CF8M

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Materials : Forged carbon steel A105N

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A105N

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Materials : Brass body dezincification-resistant up to DN1 1/4

Materials : Forged carbon steel A105N

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Forged stainless steel ASTM A182 F316

Materials : Brass body dezincification-resistant

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Materials : Stainless steel ASTM A351 CF8M

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

Materials : Carbon steel ASTM A216 WCB

Materials : Electro galvanized steel flanges

Materials : Galvanized steel flanges

Materials : Dichromate zinc plated steel flanges or AISI 316

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Materials : Dichromate zinc plated steel flanges

STAINLESS STEEL OVERFLOW VALVE TYPE 417

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

GUKO FDA. einfach. gut. beraten.

// ADapters GUIDelines

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

GUMMIKOMPENSATOR GKF8000 / GKF8130

FULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

SPECIALIST GAS VALVES AND FITTINGS

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

2-port seat valves PN25 with externally threaded connections

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Flanged pressure reducer/stabilizer VRCD

Two-port valves, male threaded, PN25

Safety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air

Installation, commissioning and servicing instructions

Engineering Data Sheet

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

USER INSTRUCTIONS FOR VALVES WITH MEMBRANES

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

MAINTENANCE PROCEDURE FOR X 650

differential pressure regulating valve - threaded

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

OPERATING INSTRUCTIONS

PRESSURE REDUCING VALVE EUROBRASS 143 FF

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Rapidmain Installation Guide

4/2 way Pneumatic Solenoid Valve

AVP-F. p setting range (bar) Code No. 003H6200

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

ELKHART BRASS MANUFACTURING COMPANY

Products no longer available

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Pressure Dump Valve Service Kit for Series 2300 Units

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD

MANUAL. Sesame. Thermoplastic Tank Technologies

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Pressure Reducing Valve DMV 750 set range: bar

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Anti-flood device Model B-1

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Overview of types. Technical data. Safety notes

About. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.

WHEATLEY Series 822/820 Swing Check Valve

Mainsboost Installation, Operation & Maintenance Instructions

Parker Legris Machine Safety: Product Sheets

KTM 50 (DN ) Installation, maintenance and operating instructions

B2KL: 6-way ball valve with male thread, PN 16

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Model MC Circuit Setter Hose Kits Supply Valve Options: Ball Valve, UBY

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

PRESSURE REDUCING VALVE EUROBRASSBLU CR FF

776 Cryogenic Safety Valve

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Transcription:

Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore Materials : Brass CW 617N Page 1 sur 6

SPECIFICATIONS : Heavy type For steel pipe Full bore Anti blow-out stem Solid ball Double o ring NBR on stem Flat yellow color steel handle USE : Gas MOP 5 class Natural Gas : obtained from petroleum ( methane ) and mix of propane / air LPG : Butane or Propane Installation in building NF E29-141 Min Temperature Ts : - 5 C Max Temperature Ts : + 60 C Max Pressure Ps : 5 bars HEAD LOSS GRAPH : RANGE : Female / Female BSP threaded valve for gas with flat yellow steel handle Ref. 620 from DN 1/2" to 2" Page 2 sur 6

MATERIALS : Item Designation Materials 1 Body Brass CW 617 N according to EN 12165 2 Ball Brass CW 617 N according to EN 12165 chromed 3 Seat PTFE 4 Nipple Brass CW 617 N according to EN 12165 5 O ring NBR 70 according to EN 549 6 Stem Brass CW 614 N according to EN 12164 7 Handle nut Steel 8 Handle Steel 9 Handle cover Plastic Page 3 sur 6

SIZE ( in mm ) : Ref. DN 1/2" 3/4" 1" 1"1/4 1 1/2 2 Ø P 15 20 25 32 40 47 L 62 70 82 98 109 125 L1 17 18.5 21 22 22 26 620 E 90 115 115 115 115 150 H 42.5 57 61 66 73.5 84 W on flat 26 32 40 49 55 68 Weight ( Kg ) 0.236 0.378 0.620 1.034 1.380 2.113 Page 4 sur 6

STANDARDS : Fabrication according to ISO 9001 : 2008 DIRECTIVE 2014/68/EU : Products excluded from directive ( Article 1, 2f.V ) GAS certificate N ROB 02 according to NF E 29-141 Designing according to EN 331 :1998+A1:2010 Marking according to directive N 305/2011 for building products Threaded female BSP cylindrical according to EN 10226-1 Rp ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. USE : Our liability can not be engaged for a non agreed using. Especially for domestic using with a flexible gas pipe where a valve with automatic closing (ROAI) is mandatory. Page 5 sur 6

GENERAL GUIDELINES : INSTALLATION INSTRUCTIONS Ensure that the valves to be used are appropriate for the conditions of the installation (type of fluid,pressure and temperature). Be sure to have enough valves to be able to isolate the sections of piping as well as the appropriate equipment for maintenance and repair. Ensure that the valves to be installed are of correct strenght to be able to support the capacity of their usage. Installation of all circuits should ensure that their function can be automatically tested on a regular basis (at least two times a year). INSTALLATION INSTRUCTIONS : Before installing the valves,clean and remove any objects from the pipes (in particular bits of sealing and metal) which could obstruct and block the valves. Ensure that both connecting pipes either side of the valve (upstream and downstream) are aligned (if they re not,the valves may not work correctly). Make sure that the two sections of the pipe (upstream and downstream) match,the valve unit will not absorb any gaps.any distortions in the pipes may affect the thightness of the connection,the working of the valve and can even cause a rupture.to be sure,place the kit in position to ensure the assembling will work. Before starting the fitting,ensure that the threads and tapping are clean. If sections of piping do not have their final support in place,they should be temporarily fixed.this is to avoid unnecessary strain on the valve. The theoretical lenghts given by ISO/R7 for the tapping are typically longer than required,the lenght of the thread should be limited, and check that the end of the tube does not press right up to the head of the thread. Position the pipe clips on both sides of the valve. When screwing the valve,ensure that you only rotate on screwed side by the 6 ended side.use an open ended spanner or an adjustable spanner and not a monkey wrench. Never use a vice to tighten the fixings of the valve. Do not over tighten the valve.do not block with any extensions as it may cause a rupture or weakening of the casing. In general,for all valves used in buildings and heating,do not tighten above a torque of 30 Nm. The advice and assembly instructions above do not conform to any guarantee. The information is given in general.it states what must not and must be done. It is provided to ensure the safety of the personnel and the reliability of the valves. The instructions in bold must be followed. Page 6 sur 6