Knowing the Job: Any employee actively engaged in dispensing propane should meet minimum responsibilities

Similar documents
5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

4.0 DOT CYLINDERS 17

At this time of year,

3.0 Basic Plant Operations Performance-Based Skills Assessment 2016

Handling and Storage of Gases

Minimum test pressure (psig) 2. Requalification period (years) DOT psig 5. non-corrosive service ( see

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Fall Propane Odorization And Odor Fade Factors

ESSENTIAL SAFETY RESOURCES

COMPRESSED GAS CYLINDERS

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

CONTENTS. SECTION 1. FLORIDA'S LP GAS LICENSING LAWS Page 03. SECTION 2. PROPANE PROPERTIES AND CHARACTERISTICS Page 07

This written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.

Process Name Compressed Gas Cylinders Program

CONTENTS. SECTION 1. FLORIDA'S LP GAS LICENSING LAWS Page 03. SECTION 2. PROPANE PROPERTIES AND CHARACTERISTICS Page 07

Training Program 1A Filling 1 lb. Refillable Propane Cylinders

PIPELINE AND HAZARDOUS MATERIAL SAFETY ADMINISTRATION CYLINDER REQUALIFICATION FACILITY INSPECTION REPORT GENERAL INFORMATION

Wayne Chaney Investigator, Southern Region Field Operations

Compressed Gasses Safety

Compressed Gas Cylinders - Guideline

Cylinder Exchange Training Manual

Savard Labor & Marine Staffing, Inc. Compressed Gas Safety Program Rev3/14

[Reserved] Packagings ICC 3 1 3AA 3AL 3AX 3A480X 3AAX

Health and Safety Guidance Note No 37

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Developing a Policy for Auto Transportation of Medical Oxygen in High Pressure Cylinders and Cryogenic Vessels

Safe Work Instructions For Oxygen Acetylene Equipment

Management Plan for Compressed Gas

Material Handling and Storage of compressed gases and Air equipment

TEXAS LP-GAS EXAMINATION STUDY GUIDE

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

R E D I C O N T R O L S

2.2 Bobtail Delivery Operations Performance-Based Skills Assessment 2016

Owner s Manual for Assembly, Operating & Maintenance of

Draft. Not yet Approved

Scorched Nuts Fire Art Guide

CALL BEFORE YOU DIG POLICY AND PROCEDURE

WARNING: FOR OUTDOOR USE ONLY

Full Internal Relief Valves Instruction Manual

Compressed Gases and Cryogens

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

Rhino Ready. Things to Know Before You Start Work

SAFETY DIRECTIVE 3.0 REFERENCES. 3.1 See Appendix B

User Operation Manual and Safety Instructions

The following instructions were provided by the manufacturer.

A guide to Part 10 of the

III. Identify the initial installation requirements for standpipe systems

INJECTION ODORIZING SYSTEMS : DOSAODOR TYPE

TABLE OF CONTENTS Case Studies for Group Discussion... 2 End of Module Quizzes: Answer Key... 6 Pre-Certification Exam: Answer Key...

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP (FOURTH REVISION)

HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

User Information Sheet 013

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General B Compressed Air and Gas Systems

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Section 35 Brieser Construction SH&E Manual

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

September 2018 Pressure Test

PRESSURIZED EQUIPMENT AND SYSTEMS

PRESSURE RETEST. 49 CFR, (g) Co#: Vin#: DOT Spec: MAWP:

Machine Cutting Torches Series 4700

1 Exam Prep. Tabs and Highlights

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C EXPIRATION DATE: June 30, 2015

EXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA

OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

Congratulations! Hand Held Torch. Warranty Policy PARTS

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Composite. care. cylinder. for responsible paintballers!

General Precautions for handling compressed gases

Table of Contents. I. General Instructions. II. Task Information. III. Operator Qualification Checklist. IV. Railroad Commission/Employer Record

Permanent expansion means a permanent increase in a cylinder's volume after the test pressure is released.

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

INSTRUCTION MANUAL. Models: OX2550KC WK5500OX DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

Federal Regulations. PSI Hazmat Training for Cylinder Safety

Compressed Gas Cylinder Safety

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

623 Series Dome Load Regulators

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Pressure Relief Valve Instruction Manual

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Hazard Communications. Your Right to Know

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Compressed Gases Storage and Handling Safety Policy. Individual Unit Function: Safety Procedure No.: SOP-0103 Page: 1 of 6

Types 749B and R130 Changeover Manifolds

Summary of the MRA LPG Codes of Practice

KENNECOTT UTAH COPPER CORPORATION SAFETY AND HEALTH STANDARDS COMPRESSED GAS

Emergency Water Injection /28/2017 updated 07/21/2017

453 Series Steam Heated Vaporizing Regulator

for Assembly, Operating & Maintenance of Model Big 60 II Gas Utility Stove THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

OWNER S MANUAL 28" GRIDDLE COOKING STATION

TOOL BOX 031- SERVICE OF CARTRIDGE EXTINGUISHERS

Cylinder HAZMAT & Fill Station Operations Compliance. PSI/PCI, Inc. William L. (Bill) High & Mark A. Gresham

for the of and the EM55-1

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

Presence PR, PRC & PRE

Transcription:

Spring 2016 Safely Filling Recreational Cylinders Knowing the Job: Any employee actively engaged in dispensing propane should meet minimum responsibilities such as: Know all regulations concerning the safe dispensing of propane. Inside... Know how to correctly inspect and identify tanks that should not be filled due to damage to the tank or qualification expiration. Continued On Next Page Spring is here and summer is rapidly approaching which is primetime-grilling season. This, of course, leads to an increase in the demand for filled grill cylinders. Cylinder exchange racks have become increasingly popular in recent years, but still many customers prefer to have their own tank filled. These customers expect and deserve to have their tanks safely and correctly filled. As propane professionals, we should strive to meet those expectations. We are going to discuss the responsibilities of propane dispensers and how they can both fill the tanks appropriately and do the best job possible to keep both themselves and the customer safe. Operating the Dispenser... Page 2 Before Refilling A Cylinder... Page 3 Correctly Filling A Cylinder... Page 4

Think Safety! Page 2 Spring 2016 Knowing the Job: How to determine the correct fill amount. How to make sure the fill area is safe from potential ignition sources such as static electricity, combustion engines, any open flame. It can t be assumed that everyone understands the potential danger. How to react in case of an emergency including shutdown procedures. Any employee filling cylinders should know the location of the emergency shutdown device as well as emergency procedures. Also, it is important that anyone who fills cylinders have the ability to provide safety information to the customer including the safe transportation of the tank once it is filled. The amount of propane that can be carried within a closed bodied vehicle is restricted. According to NFPA 58, 90 pounds total of propane can be transported in a closed vehicle. However, no more than 45 pounds of propane can be contained in one cylinder which limits the transportation of propane to two 40-pound cylinders, four 20-pound cylinders, eight 11-pound cylinders or two 33.5-pound cylinders. Whatever amount of propane is transported inside the vehicle, the filled tanks should be carried in an upright and stationary manner. A filled cylinder should never be left inside the vehicle for a long period of time. Instead it Operating the Dispenser: A dispenser operator should be familiar with how all of the equipment operates. He or she should also make sure that it is in proper working condition. First, make sure all hose-end valves are closed before slowly opening the liquid outlet valve and the downstream manual valve. Inspect all valves, piping, the transfer hose and fittings to make sure they are sound and without leaks. Also, inspect the threads of all connection adapters for excess wear. All gaskets and O rings should be in good working condition. If a leak is found, the dispenser should be shut down. Once the dispenser has been verified as safe, the cylinder can be filled. If you open the liquid outlet valve too quickly, the excess flow valve can slam shut as indicated by a snapping noise. This vehicle was damaged as a woman lit a cigarette and the propane from the cylinder inside the vehicle was ignited. should be transported directly to the customer s destination. The rising temperature inside a vehicle can quickly create a dangerous situation as the propane inside the tank begins to boil. Liquid propane expands 270 times as it turns to vapor, which increases If the excess flow valve has closed, proceed as follows: Close the downstream valve Wait for the excess flow the pressure inside the tank. Once it reaches the necessary pressure level to activate the pressure relief valve, propane vapor will be released inside the vehicle. At that point, the only thing it needs to become explosive is an ignition source. valve to reopen. (This may be indicated by a clicking sound) Open it slowly to avoid another closure.

Think Safety! Page 3 Spring 2016 Before Refilling A Cylinder: According to 49 CFR 173.301 each cylinder must be built according to all DOT qualifications. Each cylinder must pass a visual inspection. The cylinder should be observed for any crack, leak, bulge, defective valve, a leaking or defective pressure relief device, evidence of physical abuse, fire or heat damage, or detrimental rusting or corrosion. The cylinder must be equipped with a properly sized and installed pressure relief valve. The valve must also be tested for leaks using proper testing methods. If the cylinder fails the visual inspection for any of the above reasons, it cannot be filled. It must be repaired, requalified, or condemned. The cylinder can only be requalified by someone with a valid RIN. When applying for a RIN the training and qualifications of the persons who perform the inspection must be stated in the application. Cylinders may be requalified by one of three methods: Visual inspections must be requalified every five years. Simple hydrostatic test must be repeated every seven years after the cylinder has undergone the first 12-year water jacket test. Water jacket hydrostatic test must be requalified every 12 years. Most dispenser operators who requalify cylinders use the visual inspection method. It permits requalification of cylinders by a complete external inspection in accordance with Compressed Gas Association Pamphlet C-6 or C-6.3. However, the visual inspection method is permitted only by persons holding a current US DOT requalifer identification number (RIN) and the results must be recorded and maintained in accordance with CFR 49 180.215. CFR 49 180.215 requires that daily records of visual inspections be kept by the person who performs the inspection until either the expiration of the requalification period or until the cylinder is again requalified, whichever comes first. The records must include the date of inspection, DOT specification number, cylinder identification, type of cylinder protective coating, conditions checked, and disposition of cylinder. Other record-keeping requirements can be found in section 107.803-805. The requalified cylinder must be marked in accordance with 49 CFR 180.213. The markings must be made by stamping, engraving, scribing, the use of durable pressure adhesive label or any other method that produces a legible, durable mark.

Think Safety! Spring 2016 Page 4 Correctly Filling A Cylinder: According to NFPA 58, an OPD shall not be the primary means to determine when a cylinder is properly filled. The OPD is intended to be a backup device OPD valves are machined parts, machined by human beings, and as such are not infallible. Therefore, cylinders should be filled either by weight or volumetric methods to insure that the cylinder is not filled beyond 80 percent capacity. Consult NFPA 58 to determine which method is right for the particular cylinder you are filling. Most portable recreational cylinders will be filled using the weight method. When using the weight method, the cylinder should be filled to 42 percent of the marked water capacity in pounds. For instance, a 20-pound cylinder with a water capacity of 47.1 pounds should be filled with about 19.78 pounds of propane. Overfilling a cylinder can create a dangerous situation! Articles in this publication are for information only. Nothing in this publication is to be construed as setting standards or requirements. Please consult with appropriate regulatory and rulemaking bodies for all legal requirements. Tom Osina: Executive Director 107 S. West Street, #825 Alexandria, VA 22314 Phone: 703/530-9772 Fax: 703/530-9653 Web address: www.wvpropanegas.org Email address: wvpga@aol.com

Training Quiz Name Social Security Number 1. Any employee filling cylinders must know all regulations pertaining to their filling. 2. Any employee filling cylinders must know how to identify cylinders that should not be filled. 3. Any employee filling cylinders needs to make sure the fill area is free of ignition sources. 4. Any employee filling cylinders must know emergency shutdown procedures including the location of the emergency shutdown device. 5. A closed body vehicle is allowed to carry up to pounds of propane total and no more that pounds of propane in one cylinder. A. 90, 45 B. 45, 20 C. 100, 60 D. 90, 20 6. Cylinders transported in a vehicle must be kept in an upright and stationary manner. 7. Before operating a dispenser, inspect all,, the to make sure they are sound and without leaks. A. Valves B. Piping C. Transfer hose and fittings D. A,B, and C 8. If you open the liquid outlet valve too quickly on a dispenser, the excess flow valve can slam shut. 9. Before filling a cylinder, it must be observed for leaks, cracks, dents, bulges, defective relief valve or any other damage that could be a potential danger. 10. A cylinder can only be requalified by someone with a valid. A. PHD B. RIN C. BA D. RN 11. Cylinders can be requalified by. A. Visual inspection B. Simple ydrostatic test C. Water jacket hydrostatic test D. A, B, and C 12. A simple hydrostatic test must be completed every years after the cylinder has undergone the first 12- year water jacket test. A. 5 B. 12 C. 7 D. 9 13. An OPD is the primary means to determined when a cylinder has been properly filled.

Training Quiz Answers Name Social Security Number 1. Any employee filling cylinders must know all regulations pertaining to their filling. 2. Any employee filling cylinders must know how to identify cylinders that should not be filled. 3. Any employee filling cylinders needs to make sure the fill area is free of ignition sources. 4. Any employee filling cylinders must know emergency shutdown procedures including the location of the emergency shutdown device. 5. A closed body vehicle is allowed to carry up to pounds of propane total and no more that pounds of propane in one cylinder. A. 90, 45 B. 45, 20 C. 100, 60 D. 90, 20 6. Cylinders transported in a vehicle must be kept in an upright and stationary manner. 7. Before operating a dispenser, inspect all,, the to make sure they are sound and without leaks. A. Valves B. Piping C. Transfer hose and fittings D. A,B, and C 8. If you open the liquid outlet valve too quickly on a dispenser, the excess flow valve can slam shut. 9. Before filling a cylinder, it must be observed for leaks, cracks, dents, bulges, defective relief valve or any other damage that could be a potential danger. 10. A cylinder can only be requalified by someone with a valid. A. PHD B. RIN C. BA D. RN 11. Cylinders can be requalified by. A. Visual inspection B. Simple ydrostatic test C. Water jacket hydrostatic test D. A, B, and C 12. A simple hydrostatic test must be completed every years after the cylinder has undergone the first 12- year water jacket test. A. 5 B. 12 C. 7 D. 9 13. An OPD is the primary means to determined when a cylinder has been properly filled.