PRESSURE REGULATORS. Type B/240. Process Management TM

Similar documents
PRESSURE REGULATORS. Type A/140. Process Management TM

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

SLAM-SHUT VALVES. Type BM5. Process Management TM

RELIEF VALVES. Type VS- FL. Process Management TM

SLAM-SHUT VALVES. Type BM6X. Process Management TM

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

RESIDENTIAL REGULATORS

Type OS/66 Slam-Shut Controller

T208VR Series Tank Blanketing Vacuum Regulator

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

1805 Series Relief Valves

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type R622 Pressure Reducing Regulator

Type PS/79-1 and PS/79-2

Type OS/80X, OS/84X and OS/88X Slam-Shut Controller

1305 Series Pressure Reducing Regulators

Y692VB Series Vacuum Breaker

RB Series Regulating System

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

1805 Series Relief Valves

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

64 Series Pressure Reducing Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Type 1190 Low-Pressure Gas Blanketing Regulator

Type EZH Relief or Backpressure Regulator

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Types ACE95 and ACE95Sr Tank Blanketing Valves

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

971 Series Pressure Reducing Regulators

Bulletin 71.6:OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction

Type ACE95jr Tank Blanketing Valve

Type PRX/120, PRX/125, PRX-AP/120, PRX-AP/125, PRX/181, PRX/182, PRX/131 and PRX-AP/131 Pilots

1301 Series High-Pressure Regulators

Pressure regulators. Introduction. TR Head. 3 ways body Dival

RR 16 Commercial & Industrial Regulator

Commercial Service Regulator Platform

RR 16 Commercial & Industrial Regulator

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Dival 600. Pressure Regulators

Type Y692 Gas Blanketing Regulator System

1301 Series High-Pressure Regulators

Type FEQ Slam-Shut Valve

PRESSURE REGULATOR LBM SERIES

66 Series Direct-Operated Regulators and Vacuum Service Equipment

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 92S Pilot-Operated Steam Regulator

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Norval Pressure Regulators

VS100 Series Slam-Shut Device

RB 4700 Commercial & Industrial Regulator

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

299H Series Pressure Reducing Regulators

Gas Pressure Regulator HON 300

B/240 Series Spring Loaded Pressure Regulators

Type 99 Pressure Reducing Regulators

Slam Shut Valves SCN

Pressure Regulator 133 / 233

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

Norval Pressure regulator

Type 63EG Relief Valve or Backpressure Regulator

Gas Pressure Regulator HON 270 MK2

VSX4 Series Slam-Shut Device

630 Series Regulators and Relief Valves

GAS PRESSURE REGULATORS AP

Type CT88 Backpressure Regulator

Type Cronos Pressure Reducing Regulator

Series 100 Slam Shut Valve. Technical Bulletin

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Slam Shut Valves SBC 782

OBSOLETE DOCUMENT. VSX4 Series Slam-Shut Device. VSX4 Series. Contents. Introduction. Scope of the Manual. Product Description. !

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Model 1800 PFM Series Regulator. Technical Bulletin

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Safety Shut-off Valve SSV

Petro-Chemical & Analyzer Sampling Systems

Gas Pressure Regulator HON 280H - 309

627 Series Pressure Reducing Regulators

RTG 25. Introduction

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Pressure Reducing Regulator Manual

627 Series Pressure Reducing Regulators

T208 Series Tank Blanketing Vapor Recovery Regulators

MEGR-1627 Instruction Manual

S300 Series. Valve Link. Features. Fisher Controls

Aperval Pressure Regulators

Type OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction. Bulletin 71.6 D102356X012. April 2018

PRESSURE REDUCING VALVE RP45 (EN)

RB 4000 Commercial & Industrial Regulator

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

Types S100K and S102K Pressure Regulators

Safety Cut-Off Valve HON 305

Gas Pressure Regulator HON 502

Safety Shut-Off Valve HON 720

safety Shut-Off Valve HON 721

CLASS TLP Pressure Reducing Valve

Transcription:

PRESSURE REGULATORS Type B/240 Process Management TM

B/240 Series Pressure Regulator The regulators of the B/240 series due to their operating specifications are mainly used in those system where sudden capacity variations are required, or else, where the cut-off of the gas distribution is controlled by solenoid valve, such as for the feeding of burners. This product has been designed to be used with fuel gases of 1st and 2nd family according to EN 437, and with other non aggressive and non fuel gases. For any other gases, other than natural gas, please contact your local sales agent.. The B/240 series regulators are spring controlled single seated, whit counterbalanced valve disc. They are usually supplied with safety valve and built in filter and can be also provided with shut-off device for minimum pressure, maximum pressure or minimum and maximum downstream pressure. The regulators of the series B/240 have been devised keeping in consideration the functionality of maintenance, in fact is possible to replace the seat or the seals without removing the body from the line. Main features: Counterbalanced valve Available with or without relief valve Overpressure and underpressure slam shut valve Manual reset Configurations Version Without Shut-off Device B/242 B/242-AP Version With Shut-off Device B/249 B/249-AP 2

Regulator Operation The movements of the diaphragm (D) are transmitted to the valve disc (O) by the stem (S) and the lever (L). The downstream pressure through the pulse pipe (I) exerts a force under diaphragm (D) and this force is counteracted by the adjusting spring (M). The gas pressure on the diaphragm tends to close the valve disc; the antagonist action of the adjustment spring tends to open it. Under normal conditions the balance between these antagonist actions positions the valve disc in such a way as to ensure a constant pressure and therefore the downstream capacity. Upon any capacity variation tending to cause an increase or decrease of pressure in relation to the pre-set pressure, the moving unit reacts and finds a new balance, so re-establishing the pressure. Upon request the regulator is also provided with safety valve (VS) incorporated in the diaphragm (D); the adjustment at the pre-set value is performed by means of spring (M1). M M1 VS D O S L I 3

Shut-off Device Operation The B/240 series pressure regulators can be fitted with an OS/66 slam-shut valve. This safety device operates independently of the regulator and, according to customer request, can be made to trigger by any pressure variation, whether above or below set point, or by both. Outlet pressure acting upon diaphragm (D) is counteracted by maximum pressure spring (M2), thus overcoming the action of the minimum pressure valve (M3). Under such conditions, the moving part (E) of the valve is held in balance so that lever (L) is aligned with the projecting part of lever (L1). In addition, the balls (S) are held in their seat by bush (B) and, in turn, these hold the valve disc (O) open. Any outlet pressure variation over and above preset value breaks the existing balance. In fact, in case of an increase in outlet pressure, spring (M2) load is overcome by pressure load; in case of a decrease in outlet pressure, spring (M3) load overcomes pressure load. In both cases, moving part (E) is activated, causing lever (L) to move with it so that lever (L) is no longer aligned with lever (L1). In this way, lever (L1) releases balls (S), thereby allowing valve disc (O) to close under the action of spring (M4). The safety device is fitted with an internal by-pass for easy resetting even in case of high inlet pressure. For resetting, proceed as follows: Remove rear cap (C), screw it to stem (H) and pull outwards. Allow a few moments for inlet pressure to flow downstream. Next, pull cap fully outwards. Allow a few moments for outlet pressure to stabilize. Next, release cap and make sure that device remains in the reset position. If not, repeat the above steps. Once reset, replace cap in its initial position. The maximum and minimum trip values are independently set by springs (M2) and (M3), respectively. L OS/66 M1 M3 E D L1 O M4 S B H C To regulator downstream 4

Features Technical Features Body allowable pressure PS : up to 20 bar Maximum Operating Inlet Pressure P umax : 6 bar Inlet pressure range b pu : 0.1 to 6 bar Outlet Set Pressure Ranges W d : Standard 15 to 75 mbar AP 75 to 300 mbar AP (QL option) 300 to 500 mbar Functional Features Accuracy class AC : up to ± 5% Lock-up pressure class SG : up to +10% Maximum capacity Q max : up to 300 Stm 3 /h Shut-off device Independent pneumatic control Accuracy class AG : ± 5% Response time t a : 1 second Orifice 17 mm Body Sizes and End Connection Styles Threaded: Inlet and outlet 1½ BSP Flanged: DN 40 PN 16 UNI/DIN Temperature Standard version : Working -10 to 60 C Low temperature version : Working -20 to 60 C Versions Version without relief valve available on request Materials Servomotor body Cover Body Sleeve Seat Diaphragm Gaskets Aluminium Aluminium Ductile iron (steel available on request) Brass Brass Fabric Nitrile (NBR) Nitrile (NBR) rubber 5

Slam-Shut Device The following slam-shut devices are used with B/240 series regulators with built-in shut-off device: OS/66 Spring loaded Technical Features Model Servomotor Body Resistance (bar) Overpressure Set Range W do (bar) Underpressure Set Range W du (bar) Min. Max. Min. Max. OS/66 0.022 0.6 0.007 0.450 6 OS/66-AP 0.2 5 0.1 2.5 Materials Body Aluminium Cover Steel Diaphragm NBR Rubber Flow Table Stm 3 /h Following flow tables (referred to Natural Gas) are advised for an optimal use of the B/240 series regulators. For other gases with different densities, the flow rate must be multiplied by the correction factor: F= 0.6 d Gas Relative Density d Factor F Air 1 0.78 Butane 2.01 0.55 Propane 1.53 0.63 Nitrogen 0.97 0.79 Outlet Inlet Pressure bar Pressure mbar 0.03 0.05 0.075 0.1 0.15 0.2 0.3 0.4 0.5 0.75 1 1.5 2 3 4 5/6 15 12 15 20 30 40 50 65 80 100 120 120 170 200 250 250 250 20-15 20 30 40 50 65 80 100 120 120 170 200 250 250 250 30-12 20 30 40 50 65 80 100 120 120 170 200 250 250 250 40 - - 15 25 40 50 65 80 100 120 120 170 200 250 250 250 50 - - 15 20 40 50 65 80 100 120 120 170 200 250 250 250 75 - - - 15 30 45 60 80 100 120 120 170 200 250 250 250 100 - - - - 20 40 50 80 100 120 120 170 200 250 280 300 150 - - - - - 30 40 70 100 120 120 170 200 250 280 300 200 - - - - - - 30 60 100 120 120 170 200 250 280 300 300 - - - - - - - 50 80 110 110 170 200 250 280 300 300 - - - - - - - 30 40 60 80 130 170 200 230 250 350 - - - - - - - - 40 60 80 130 170 200 230 250 400 - - - - - - - - 35 60 80 130 170 200 230 250 450 - - - - - - - - - 60 80 130 170 200 230 250 500 - - - - - - - - - 50 75 120 160 190 220 240 Standard AP QL Option 6

Dimensions (mm) and Weights (kg) B/249 B/249-AP B/242 B/242-AP 200 125 200 50 175 170 50 175 153 90 153 252 170 252 50 184 184 48 48 130 130 75 75 FS Version FS Version Note: The regulator can be installed with vertical or horizontal orientation of the actuator. Weights B/242 B/242-AP: 3.5 kg B/242-FS B/242-AP-FS: 7.5 kg B/249 B/249-AP: 4.5 kg B/249-FS B/249-AP-FS: 8.5 kg 7

TM Industrial Regulators Natural Gas Technologies LP-Gas Equipment TESCOM Emerson Process Management Regulator Technologies, Inc. Emerson Process Management Regulator Technologies, Inc. Emerson Process Management Regulator Technologies, Inc. Emerson Process Management Tescom Corporation USA - Headquarters McKinney, Texas 75070 USA Tel: +1 800 558 5853 Outside US: +1 972 548 3574 USA - Headquarters McKinney, Texas 75070 USA Tel: +1 800 558 5853 Outside US: +1 972 548 3574 USA - Headquarters McKinney, Texas 75070 USA Tel: +1 800 558 5853 Outside US: +1 972 548 3574 USA - Headquarters Elk River, Minnesota 55330-2445 USA Tel: +1 763 241 3238 +1 800 447 1250 Europe Bologna 40013, Italy Tel: +39 051 419 0611 Asia-Pacific Shanghai 201206, China Tel: +86 21 2892 9000 Middle East and Africa Dubai, United Arab Emirates Tel: +971 4811 8100 Europe Bologna 40013, Italy Tel: +39 051 419 0611 Chartres 28008, France Tel: +33 2 37 33 47 00 Asia-Pacific Singapore 128461, Singapore Tel: +65 6770 8337 Middle East and Africa Dubai, United Arab Emirates Tel: +971 4811 8100 Europe Selmsdorf 23923, Germany Tel: +49 38823 31 287 Asia-Pacific Shanghai 201206, China Tel: +86 21 2892 9499 For further information visit www.emersonprocess.com/regulators Our Global Product Brands: TM The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher, Tartarini, Francel, Emerson Process Management and the Emerson Process Management design are marks of the Emerson Process Management group of companies. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management product remains solely with the purchaser. O.M.T. Officina Meccanica Tartarini S.R.L., Via P. Fabbri 1, I-40013 Castel Maggiore (Bologna), Italy R.E.A 184221 BO Cod. Fisc. 00623720372 Part. IVA 00519501209 N IVA CEE IT 00519501209, Cap. Soc. 1.548 000 Euro i.v. R.I. 00623720372 - M BO 020330 Francel SAS, 3 Avenue Victor Hugo, CS 80125, Chartres 28008, France SIRET 552 068 637 00057 APE 2651B, N TVA : FR84552068637, RCS Chartres B 552 068 637, SAS capital 534 400 Euro D103746X012-07/2015 - Rev.00 Emerson Process Management Regulator Technologies, Inc., 2015; All Rights Reserved