START UP MANUAL MADE IN USA REV US and Foreign patents and patents pending see

Similar documents
MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

MDX-R3 FOR ADJUSTABLE CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

D05 Pressure Regulating Valves

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 3000 Units

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

NOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR

DS05C,D,G Dial Set Pressure Regulating Valves

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Aquor House Hydrant V2

Halsey Taylor Owners Manual STOP!

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

V43 Pressure Actuated Water Regulating Valve

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

Installation of Your SprayMaster System

Vessel Installation and Operating Manual

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

TECHNICAL DATA CAUTION

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Installation Instructions

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

Installation and Operating Manual

SKIMMER FOR CONCRETE POOLS OWNER S MANUAL AND INSTALLATION GUIDE

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

D05T Compact Design Pressure Regulating Valves

INSTALLATION INSTRUCTIONS

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

Combination Air Valve Model

36H SERIES Combination Gas Valve

Booster Pump PB4-60 Replacement Kits

Operator: Save these instructions for future use!

! WARNING. Before using this product read and understand instructions.

Operation Manual Guillotine Cutter RC-5

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

Product Information News

Speed control assembly model A-1

Installation and commissioning instructions 255 series and 256 series

SKIMMER FOR VINYL & FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Float Operated Level Controllers

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Combination Air Valve

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

NOTICE. SDX HIGH FLOW SAFETY DRAIN For Concrete, vinyl & equalizer pools OWNER S MANUAL & INSTALLATION GUIDE

Installation Instructions

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t S. Korean patent VAC psi (228 bar, 22.8 MPa) Maximum Working Pressure

Installation, Operation, and Maintenance Manual

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Cristal -Flo II Filter OwnerÕs Manual

UltRo Dual Flow Reverse Osmosis Water System

MANUAL BE SERIES Test Benches

Installation Instructions

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

Operation Manual Piston Sensed Gas Pressure Regulators

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Cryogen Dispenser. Directions for Use.

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Sand Dollar Filter Owner s Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

NO WORK. ALL PLAY. NO WORK. ALL PLAY.

DS06D,G Dial Set Pressure Regulating Valve

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

3/8" Dr. Air Butterfly Impact Wrench

SEP 100 D.E. SEPARATION TANK

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Section 3- Repair and Calibration Procedures

Installation, Operation, Maintenance Manual For Quick-Jaw Models AL363, L364 & AL366

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

PAGE (Rev. A - 06/17)

TECHNICAL DATA. Q = C v P S

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Instruction & Parts Manual

Metric Porcelain Enamel Powder Pump

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

Warning: NEVER ALTER TEST EQUIPMENT

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

RG1200 Service and Repair Manual

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

8-GALLON AIR-OPERATED OIL CHANGER

! WARNING. Before using this product read and understand instructions.

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

TECHNICAL DATA. Q= Cv S

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

NORMAL OPERATING DISPLAYS GENERAL OPERATION

Transcription:

START UP MANUAL MADE IN USA 004-027-8896-00 REV 033116 295 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com www.1paramount.com US and Foreign patents and patents pending see www.1paramount.com/about/patents/

SYSTEM DESIGN The Paralevel is designed to control the water level in a swimming pool or spa. The Posi-Click control makes adjusting the water level very easy. Four clicks (or one revolution) of the adjustment wheel changes the water level by ¼. The Paralevel uses Smart Sensing, eliminating rapid cycling of the device even when the pool is being used. The user can use 1 ½ or 2 pipe for the balance line. The water line can be plumbed with ½ or ¾ pipe. The Paralevel can also be plumbed with 2 pipe for overflow protection, offering the highest overflow protection in the industry. PARALEVEL LAYOUT AND DESIGN CRITERIA 1. Paralevel should be level and plumb. 2. The Paralevel main housing is engraved with Max High; Max Low; and Pool Level. The housing should be mounted so that the Pool Level line is at the expected water level. 3. Maximum water pressure is 80 psi. 4. The fill rate at 50 psi is 120 gph (2880 gallons per day). 5. Warning: Balance line and overflow line must be plumbed straight. Failure to keep the run of pipe straight may cause an airlock. BAD BAD START UP 1. Make sure the water supply line is turned off at the valve. 2. Remove plugs Use the Removal Tool to remove the 1 ½ NPT Cap. Use a 3/8 socket extension to remove the ½ NPT Seal Plug (Fig. 1) 3. Turn on water supply line to flush line for a couple of minutes. Then shut it off. 4. Install the 1½ NPT Nut Retainer. Hand tighten ONLY, even when using tool. Make sure that the Retainer Ring is installed properly in the Retainer Nut. The retaining piece with raised rounded center is inserted facing the top of the retainer nut. (Fig. 2) Use the Removal Tool to install the Nut Retainer 5. Install the ½ NPT Flow Plug Use a 3/8 socket extension to install the Flow Plug (Fig. 3) FIG. 1 SEAL PLUG 1 1/2 NPT CAP FIG. 2 Retaining ring top view with raised rounded center Retaining ring bottom view with sharper center Top View: Correct position of retaining ring inside retainer nut with rounded center exposed. Bottom View: Correct position of retaining ring inside retainer nut with sharper center exposed. 2

6. Installing float assembly Grasp the top of the Riser Tube. (Fig. 4) Start with float half way on sleeve adjuster (Fig. 5) Position the end of the Riser Tube with the o-ring inside the opening at the top of the Nut Retainer. (Fig. 6) Turn the riser tube clockwise and wiggle until it drops into the Nut Retainer. Too much downward pressure before it sets into the opening of the Nut Retainer will cause the float assembly to hang up. (Fig. 7) Press down on the top of the Riser Tube and twist clockwise ¼ turn or until it stops.(fig. 8) 7. Adjustment procedure (standard 3 waterline below beam) Turn on water supply at source fully. The Paralevel has anti-water hammer feature as part of its smart sensing. The Paralevel works best at full pressure Fill the pool until the water level is just below center of tile with less than 1 left to fill. Shut off and remove all auxiliary hoses. Leave the Paralevel water supply on. Allow the water level to rise until the Paralevel shuts off. Measure the water level from top of beam or bottom of deck. Note the difference from desired water level Remove float from housing or reach down on one side pushing on the alternately raised part of the float. Turn the float counter-clockwise one revolution for every ¼ the pool needs to rise and clockwise one revolution for every ¼ the pool needs to lower. Example: to raise the water level 1, turn the float counter-clockwise four revolutions. (Fig. 9a and 9b) FIG. 3 FLOW PLUG RETAINER NUT FIG. 4 FIG. 5 FIG. 6 End of riser tube Opening at top of nut retainer FIG. 9a FIG. 7 FIG. 9b FIG. 8 3

You will need the items in the winterizing / pressure test kit part number 005-760-2911-00 and tool 004-627-5452-00. 1. Turn off the water to the Paralevel. WINTERIZING INSTRUCTIONS 2. Remove the Paralevel float assembly by grasping the top of the float assembly (above the adjustment wheel and while pushing down turn the assembly counter clockwise a quarter turn. The float assembly should then pull out. Next using the removal tool #10 on the Paralevel exploded parts diagram (page 6), remove the Retainer Nut and Retainer Ring #19 and #20. Next using a 3/8 inch socket wrench extension remove the Flow Plug and O-ring #17 and #18 on the Paralevel exploded parts diagram. (page 6) 3. Drain the water in the pool to below the opening for the equalizer line for the Paralevel. Place the O-ring and Seal Plug #4 and #5 on the winterizing kit exploded parts diagram (page 7) into the threaded hole that the Flow Plug was removed from. Note: If draining the pool down below the equalizer line is not practical, then blow out the equalizer line at the pool side by using a test plug with a Schrader valve and an air compressor, at the same time suck out the water from the water leveler canister. 4. Disconnect the water supply line at the house going to the Paralevel. Blow this line to the opening where the Retainer Nut and O-ring were while using a wet/dry shop-vac placed directly over the threaded opening where the Retainer Nut was removed from to collect the water blown into the Paralevel housing. When the line is clear place the Cap Seal and Main seal #1 and #3 on the winterizing kit exploded parts diagram (page 7) over this opening. It is recommend that the disconnected water line at the house be taped shut or sealed when disconnected so insects and debris don t get in the line. 5. Keep all of the plugs gaskets and o-ring removed for winterizing for startup in the spring. Note: the float assembly will not need to be adjusted next spring as long as you do not turn the adjustment wheel from its set position when removed. 6. Optional: poor some non-toxic anti-freeze in the water leveler canister. IDENTIFYING PARALEVEL MODEL 1. Turn off the water. 2. Grasp top of float assembly, twist counter clockwise ¼ turn, and pull out. Old Float FIG. 10a New Float FIG. 10b Old Tank FIG. 11a New Tank FIG. 11b Ribs 4

USING NEW FLOAT IN OLD TANK 1. While holding the new float, twist sleeve counter clockwise until it comes out of the float. 2. Turn float over and re-thread on sleeve with flat side up. Be careful not to cross-thread. (Fig. 12) 3. Compare the float height on the sleeve to the old float. The new style float will need to be approximately 5/8 lower on the sleeve to achieve a similar water level. (Fig. 13) 4. Install in the housing and turn on the water supply. 5. If the float is off, shut off the water and remove the float and turn in the direction indicated on the flat side of the float to raise the water level 1/8, one half turn, or 2 posi-clicks. Follow the arrows on the float. (Fig. 14) 6. If the float is on, shut off the water and remove the float and turn in the direction indicated on the flat side of the float to raise the water level 1/8, one half turn, or two (2) posi-clicks. Follow the arrows on the float. (Fig. 14) 7. Repeat steps 5a or 5b until water level is matched. 8. Check pool level after a few days to verify correct set level. FIG. 12 FIG. 13 FIG. 14 Arrows 5

004-760-2902-XX PARALEVEL B 1 4 8 12 11 13 21 2 14 15 22 3 16 9 17 18 20 19 10 23 Item Part Number Description 1 005-760-2901-XX LID 2 005-760-2915-XX DECK RING 3 HOUSING 4 005-760-2911-00 WINTERIZATION/PRESSURE TEST KIT * 1 ½ NPT CAP * MAIN SEAL * CAP SEAL * SEAL PLUG * O-RING 2-020 EP70 8 005-252-1541-00** EXTENSION KIT 9 004-627-5452-00** TOOL 10 004-760-2921-00 START UP KIT B 11 * TOP LEVER 12 * LOWER LEVER 13 * LINK LEVER 14 * RISER TUBE 15 * SNAP RING 16 * O RING 2-011 VITON DUR 75 17 * FLOW PLUG 18 * O RING 2-020 EP70 19 * RETAINER NUT 20 * RETAINER RING 21 * ADJUSTER SLEEVE 22 * FLOAT BODY 23 005-761-2934-00 EXTENSION 1 * Parts are not available separately ** not part of Paralevel order separately 6

004-760-2900-XX PARALEVEL A 10 1 4 8 9 11 12 13 21 2 14 3 15 22 16 23 17 18 19 20 Item Part Number Description 1 005-760-2901-XX LID 2 DECK RING 3 HOUSING 4 005-760-2911-00 WINTERIZATION/PRESSURE TEST KIT * 1 ½ NPT CAP * MAIN SEAL * CAP SEAL * SEAL PLUG * O-RING 2-020 EP70 8 EXTENSION KIT 9 004-627-5452-00** TOOL 10 004-760-2921-00 START UP KIT 11 * TOP LEVER 12 * LOWER LEVER 13 * LINK LEVER 14 * RISER TUBE 15 * SNAP RING 16 * O RING 2-011 VITON DUR 75 17 * FLOW PLUG 18 * O RING 2-020 EP70 19 * RETAINER NUT 20 * RETAINER RING 21 * ADJUSTER SLEEVE 22 * FLOAT BODY 23 005-761-2934-00 EXTENSION 1 * Parts are not available separately ** not part of Paralevel order separately 7

005-760-2911-00 PARALEVEL WINTERIZING/ PRESSURE TEST KIT 1 2 3 4 5 Item Part Number Description *005-760-2911-00 WINTERIZATION/PRESSURE TEST KIT 1 ½ NPT CAP 2 MAIN SEAL 3 CAP SEAL 4 SEAL PLUG 5 O RING 2-020 EP70 *Sold Separately 8