UKEPR Issue 04

Similar documents
UKEPR Issue 05

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER P: REFERENCE OPERATING CONDITION STUDIES (PCC)

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS. A high-capacity EBA system [CSVS] [main purge]

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER F: CONTAINMENT AND SAFEGUARD SYSTEMS 7. CONTAINMENT HEAT REMOVAL SYSTEM (EVU [CHRS])

UKEPR Issue 04

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 2. VOLUME AND CHEMICAL CONTROL (RCV [CVCS])

DISTRIBUTION LIST. Preliminary Safety Report Chapter 7 Safety Systems UK HPR1000 GDA. GNS Executive. GNS all staff. GNS and BRB all staff CGN EDF

CONTENTS OF THE PCSR CHAPTER 1 - INTRODUCTION AND GENERAL DESCRIPTION

UKEPR Issue 01

Engineering & Projects Organization

STEP 3 INTERNAL HAZARDS ASSESSMENT OF THE EDF and AREVA UK EPR DIVISION 6 ASSESSMENT REPORT NO. AR 09/026-P

HEALTH AND SAFETY EXECUTIVE HM NUCLEAR INSTALLATIONS INSPECTORATE

Office for Nuclear Regulation

Workshop Information IAEA Workshop

The Nitrogen Threat. The simple answer to a serious problem. 1. Why nitrogen is a risky threat to our reactors? 2. Current strategies to deal with it.

Every things under control High-Integrity Pressure Protection System (HIPPS)

Recent Research on Hazards PSA

NOT PROTECTIVELY MARKED. REDACTED PUBLIC VERSION HPC PCSR3 Sub-chapter 16.2 PSA Results and Discussion NNB GENERATION COMPANY (HPC) LTD

ASVAD THE SIMPLE ANSWER TO A SERIOUS PROBLEM. Automatic Safety Valve for Accumulator Depressurization. (p.p.)

IC67 - Pre-Instructional Survey

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

SAFETY APPROACHES. The practical elimination approach of accident situations for water-cooled nuclear power reactors

Regulatory requirements with respect to Spent Fuel Pool Cooling

DISTRIBUTION LIST. Preliminary Safety Report Chapter 19 Internal Hazards UK HPR1000 GDA. GNS Executive. GNS all staff. GNS and BRB all staff CGN EDF

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

QuickHeat TM Packaged Heat Exchanger Solutions

Assessment of Internal Hazards

Safety Classification of Structures, Systems and Components in Nuclear Power Plants

-. 30ýv. Entergy ARKANSAS NUCLEAR ONE - UNIT I IMPROVED TECHNICAL SPECIFICATIONS SUBMITTAL. 05/01101 Supplement Volume 2 of 2. (Sections 3.7 and 3.

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Ranking of safety issues for

TSS21 Sealed Thermostatic Steam Tracer Trap

Complementarity between Safety and Physical Protection in the Protection against Acts of Sabotage of Nuclear Facilities

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

Solenoid Valves used in Safety Instrumented Systems

Review and Assessment of Engineering Factors

NUBIKI Nuclear Safety Research Institute, Budapest, Hungary

IAEA SAFETY STANDARDS for protecting people and the environment

DF1 and DF2 Diffusers

Preliminary Failure Mode and Effect Analysis for CH HCSB TBM

HTR Systems and Components

The Future of Hydraulic Control in Water-Systems

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

A large Layer of Protection Analysis for a Gas terminal scenarios/ cause consequence pairs

IAEA SAFETY STANDARDS for protecting people and the environment

Manual Actuated Boiler Blowdown Valves

GAS FUEL VALVE FORM AGV5 OM 8-03

TEPCO s Safety Assurance Philosophy on Nuclear Power Generation Plants

Safety manual for Fisher GX Control Valve and Actuator

SINGER MODEL 106/206-RPS-L&H

Considerations for the Practical Application of the Safety Requirements for Nuclear Power Plant Design

Containment Isolation system analysis and its contribution to level 2 PSA results in Doel 3 unit

EDUCATION DEPARTMENT ACCU-TEST

EMERGENCY CORE COOLING SYSTEM SIMPLIFICATION

INHERENTLY SAFER DESIGN CASE STUDY OF RAPID BLOW DOWN ON OFFSHORE PLATFORM

GUIDE YVL 3.7 / 26 Se p t e m b e r 2008

AP1000 European 19. Probabilistic Risk Assessment Design Control Document

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Fisher DVI Desuperheater Venturi Inline

Custom-Engineered Solutions for the Nuclear Power Industry from SOR

PROCEDURES FOR REPAIRS TO ASME NV STAMPED PRESSURE RELIEF DEVICES OF NUCLEAR SAFETY RELATED PRESSURE RELIEF VALVES

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand

SHUTDOWN SYSTEMS: SDS1 AND SDS2

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

Safety Engineering - Hazard Identification Techniques - M. Jahoda

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

SAFETY MANUAL PURGING, VENTING & DRAINING PROCEDURE TABLE OF CONTENTS 1. INTRODUCTION SCOPE DEFINITIONS PROCEDURE...

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Thermocirc Installation and Maintenance Instructions

DeZURIK. KSV Knife Gate Valve. Safety Manual

M-06 Nitrogen Generator (Nitrogen Making Machine)

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

SENSITIVITY ANALYSIS OF THE FIRST CIRCUIT OF COLD CHANNEL PIPELINE RUPTURE SIZE FOR WWER 440/270 REACTOR

Nuclear Safety. Module 3 DEFENSE IN DEPTH. Reacu03.ppt. Slide!

«DO160/ED14» - Jessica France

Transient Analyses In Relief Systems

MDEP Common Position No AP

Safety in Petroleum Industry

SEBIM PILOT OPERATED TANDEMS A NEW SOLUTION FOR DARLINGTON NGS BLEED CONDENSER RELIEF VALVES. HORST PAETZOLD Ontario Hydro Nuclear - Darlington NGD

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

BERMAD Fire Protection Hydraulic Control Valves

Nuclear safety Lecture 4. The accident of the TMI-2 (1979)

10. SYSTEM ANALYSIS. The assessment consist of two elements: Safety Analysis Report and an independent Review of Safety Report.

Record of Assessment OFFICER IN CHARGE OF AN ENGINEERING WATCH

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

Technical Data Sheet MF010-O-LC

NORMAL OPERATING PROCEDURES Operating Parameter Information

FUEL GAS FIRING CONTROL RJ (Dick) Perry Safety Systems Consultant 6 June 2016

BMW proposal for. Technical requirements concerning LIQUID HYDROGEN STORAGE SYSTEMS. for the use in hydrogen powered road vehicles

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

INTERPLANT STANDARD - STEEL INDUSTRY

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Thank You for Attending Today s Webinar. Today s Featured Speaker

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

Transcription:

Title: PCSR Sub-chapter 6.8 Main steam relief train system - VDA [MSRT] Total number of pages: 16 Page No.: I / III Chapter Pilot: M. LACHAISE Name/Initials Date 25-06-2012 Approved for EDF by: A. PETIT Approved for AREVA by: G. CRAIG Name/Initials Date 26-06-2012 Name/Initials Date 26-06-2012 REVISION HISTORY Issue Description Date 00 First issue for INSA information 11-12-2007 01 Integration of technical and co-applicant comments 28-04-2008 02 PCSR June 2009 Update: Clarification of text Technical update according to December 2008 design freeze 03 Consolidated Step 4 PCSR update: - Minor editorial changes - Update of references (English translations) 04 Consolidated PCSR update: - References listed under each numbered section or sub-section heading numbered [Ref-1], [Ref-2], [Ref-3], etc - Minor editorial and typographical changes 26-06-2009 30-03-2011 26-06-2012

Title: PCSR Sub-chapter 6.8 Main steam relief train system - VDA [MSRT] Page No.: II / III Copyright 2012 AREVA NP & EDF All Rights Reserved This document has been prepared by or on behalf of AREVA NP and EDF SA in connection with their request for generic design assessment of the EPR TM design by the UK nuclear regulatory authorities. This document is the property of AREVA NP and EDF SA. Although due care has been taken in compiling the content of this document, neither AREVA NP, EDF SA nor any of their respective affiliates accept any reliability in respect to any errors, omissions or inaccuracies contained or referred to in it. All intellectual property rights in the content of this document are owned by AREVA NP, EDF SA, their respective affiliates and their respective licensors. You are permitted to download and print content from this document solely for your own internal purposes and/or personal use. The document content must not be copied or reproduced, used or otherwise dealt with for any other reason. You are not entitled to modify or redistribute the content of this document without the express written permission of AREVA NP and EDF SA. This document and any copies that have been made of it must be returned to AREVA NP or EDF SA on their request. Trade marks, logos and brand names used in this document are owned by AREVA NP, EDF SA, their respective affiliates or other licensors. No rights are granted to use any of them without the prior written permission of the owner. EPR TM is an AREVA Trade Mark. Trade Mark For information address: AREVA NP SAS Tour AREVA 92084 Paris La Défense Cedex France EDF Division Ingénierie Nucléaire Centre National d'equipement Nucléaire 165-173, avenue Pierre Brossolette BP900 92542 Montrouge France

Title: PCSR Sub-chapter 6.8 Main steam relief train system - VDA [MSRT] Page No.: III / III TABLE OF CONTENTS 0. SAFETY REQUIREMENTS 0.1. SAFETY FUNCTIONS 0.2. FUNCTIONAL CRITERIA 0.3. DESIGN REQUIREMENTS 0.4. TESTS 1. SYSTEM ROLE 2. DESIGN BASIS 2.1. GENERAL ASSUMPTIONS 2.2. INSTRUMENTATION AND CONTROL 3. EQUIPMENT DESCRIPTION AND CHARACTERISTICS 3.1. DESCRIPTION OF THE ISOLATION VALVES 3.2. DESCRIPTION OF CONTROL VALVE 3.3. FLOW DIAGRAM 4. OPERATING CONDITIONS 4.1. SYSTEM NORMAL OPERATING STATE 4.2. SYSTEM OPERATING CONDITIONS 4.3. SYSTEM TRANSIENT STATES 5. PRELIMINARY SAFETY ANALYSIS 5.1. COMPLIANCE WITH REGULATIONS 5.2. COMPLIANCE WITH FUNCTIONAL CRITERIA 5.3. COMPLIANCE WITH DESIGN REQUIREMENTS 6. TESTS, INSPECTION AND MAINTENANCE

PAGE : 1 / 13 SUB-CHAPTER 6.8 MAIN STEAM RELIEF TRAIN SYSTEM - VDA [MSRT] [REF-1] TO [REF-5] 0. SAFETY REQUIREMENTS 0.1. SAFETY FUNCTIONS 0.1.1. Reactivity control The Main Steam Relief Train system VDA [MSRT] does not contribute to controlling reactivity. 0.1.2. Decay heat removal The VDA [MSRT] must be capable of removing decay heat by dumping steam from the main steam system to atmosphere (in the period between hot shutdown and connection of the RIS/RRA [SIS/RHRS]) in the event of a turbine trip with the condenser unavailable. During PCC-2 to PCC-4 or RRC-A events, the VDA [MSRT] must remove decay heat by discharging steam to the atmosphere in order to achieve a safe shutdown state (connection of the RIS/RRA [SIS/RHRS]). During small or intermediate breaks in the primary cooling system, or in the event of Steam Generator Tube Rupture (SGTR), the VDA [MSRT] system may be used to cool the primary cooling system until the MHSI injection pressure is reached (partial cooling). Note: The latter two functions may be provided by steam dump to the condenser if it is available, but, for classification reasons, this possibility is not considered in the corresponding PCC-2 to PCC-4 studies. During small or intermediate breaks in the primary cooling system combined with the total failure of the MHSI and when steam dump to the condenser is not available, the VDA [MSRT] may be used to cool the primary cooling system until the LHSI injection pressure is reached (rapid cooling). 0.1.3. Containment of radioactive substances During PCC-2 to PCC-4 and RRC events, the VDA [MSRT] contributes to protecting the steam generator against overpressure. 0.2. FUNCTIONAL CRITERIA 0.2.1. Reactivity Control The VDA [MSRT] does not contribute to the control of reactivity.

PAGE : 2 / 13 0.2.2. Decay heat removal The VDA [MSRT] is designed to remove decay heat to ensure that the fuel temperature remains below the associated safety limits and the reactor coolant pressure boundary (RCPB) remains within its design conditions. Decay heat must be removed during PCC-2 to PCC-4 events even assuming loss of external power supplies combined with a single failure (one VDA [MSRT] train fails to operate). 0.2.3. Containment of radioactive substances The VDA [MSRT] contributes to protection against overpressure (see Sub-chapter 3.4). 0.3. DESIGN REQUIREMENTS 0.3.1. Requirements from safety classifications Safety classification The VDA [MSRT] is safety classified according to the classification presented in Sub-chapter 3.2. Single failure criterion (active and passive) For components providing F1 functions, the single failure criterion must be satisfied in order to ensure adequate redundancy. Emergency power supplies The power supply for components with an F1 function must be backed-up so that their functions can be performed even in the event of loss of external power. Qualification for operating conditions Components providing an F1 function must be qualified for the ambient conditions anticipated when they are required to operate in order to perform their safety function. The resulting requirements for the component design (integrity, operability, functional capacity, etc.) are presented in Sub-chapter 3.6. Mechanical, electrical, instrumentation and control classifications The classifications are presented in Sub-chapter 3.2. Seismic classification The VDA [MSRT] must be seismically classified according to the classification rules presented in Sub-chapter 3.2. Periodic tests VDA [MSRT] safety classified components must be tested periodically.

PAGE : 3 / 13 0.3.2. Other statutory requirements 0.3.2.1. Basic Safety Rules See Sub-chapter 1.4. 0.3.2.2. Technical guidelines See Sub-chapter 3.1. 0.3.3. Hazards Internal hazards The VDA [MSRT] must be protected against internal hazards in accordance with the requirements presented in Sub-chapter 13.2. The break exclusion concept applies to the main steam lines inside containment (between the SG outlet and the containment penetration fixed point) and outside containment (between the containment penetration and the first fixed point downstream of the main steam isolation valve), including the connections to the three largest connected lines, (i.e. the VDA [MSRT] line up to the isolation valve and the two VVP [MSSS] safety relief valve connections). External hazards The VDA [MSRT] must be protected against external hazards in accordance with the requirements presented in Sub-chapter 13.1. 0.4. TESTS Preliminary tests Preliminary commissioning tests are required to enable the adequacy of the VDA [MSRT] design and performance to be ensured. Periodic tests and in-service inspection The location and design of the VDA [MSRT] equipment must allow accessibility for in-service inspection and periodic testing. The safety classified components must be tested and checked for functionality. 1. SYSTEM ROLE The VDA [MSRT] consists of pipework and power-operated valves that discharge steam from the secondary cooling system into the atmosphere. Apart from the safety functions described in 0, the VDA [MSRT] is designed to perform the following functions:

PAGE : 4 / 13 The system forms part of the main secondary cooling system. It (partially) protects the steam generator against overpressure. The system is used for dumping heat from the steam generators to the atmosphere when the condenser is unavailable. In particular, it may be used to cool the reactor between the hot shutdown state and LHSI connection conditions in RRA [RHRS] mode. 2. DESIGN BASIS 2.1. GENERAL ASSUMPTIONS The system design basis is described in Sub-chapter 10.3 dedicated to VVP [MSSS]. The system design provides protection against overpressure. Specifically the opening pressures of the VDA [MSRT] atmospheric relief valves and the VVP [MSSS] safety relief valves are as follows: Total shut-off head of the MHSI pumps is below the opening pressure of the VDA [MSRT] atmospheric relief valves, which is in turn below the set-pressure of the VVP [MSSS] safety relief valves. The capacity of a VDA [MSRT] train is 50% of the full load steam production at the design pressure [Ref-3]. A high level of leak-tightness is required for control valves that are required to protect against failure to close the corresponding isolation valves. The following design requirements also apply: The VDA [MSRT] control valves and isolation valves must be capable of discharging sub-cooled water or a steam/water mixture in the event of SG overfill, or following a 2A-MSLB. Silencers are designed such that the noise from a steam discharge through the VDA [MSRT] remains within statutory limits. 2.2. INSTRUMENTATION AND CONTROL 2.2.1. General design In each train the following components are powered and controlled by the Instrumentation and Control equipment: The solenoid pilots of isolation valve (the opening/closing function is controlled by different electrical divisions but powered with DC power supply from the electrical division corresponding to the mechanical division containing the valve). The control valve motor (powered by a non-interruptible AC power supply from the electrical division corresponding to the mechanical division containing the valve).

PAGE : 5 / 13 2.2.2. Automatic control For PCC-2 to PCC-4 events automatic control of the VDA [MSRT] relief valves is achieved by the safety classified Programmable Logic Control (PLC) system. The automatic control actions are: Opening of valves to achieve and maintain a controlled constant steam pressure when a high steam pressure exists. Partial cooling controlled at 250 C/h when there is a low pressuriser pressure (due to a small primary break). Partial cooling controlled at 250 C/h when there is a high water level in a steam generator (due to SGTR). (For the cooling, the isolation valve which is closed in normal operation is opened, and the control valve which is open in normal operation is used to control the main steam pressure). Generation of an isolation signal when there is low steam pressure (discharge to atmosphere due to inadvertent valve opening). Generation of an isolation signal when a high SG water level exists (due to SGTR) and partial cooling has been completed. 2.2.3. Controls that are accessible to the operator Control valve actuation: the VDA [MSRT] control valves are controlled (PICS and SICS) from the Main Control Room (MCR). Isolation valve actuation: all the solenoid pilot valves may be individually actuated from the Main Control Room (MCR) by PICS and SICS (to actuate the isolation valves or to carry out tests). 3. EQUIPMENT DESCRIPTION AND CHARACTERISTICS [REF-2] 3.1. DESCRIPTION OF THE ISOLATION VALVES The VDA [MSRT] isolation valve is located in the main steam line between the containment penetration and the main steam isolation valve (MSIV). It is a wedge type globe valve with a self-controlled relief valve using the depressurisation principle. A hold-open device is mounted on the valve envelope. A set of steam pilot valves is used for opening and for closing. This set consists of four solenoid pilot valves with two pilots in series in each of the two redundant control lines. This configuration is used to prevent a pilot valve failure from causing inadvertent opening, or prevention of opening, of the isolation valve.

PAGE : 6 / 13 After opening, the valve remains opened even in case of I&C power default and until a closing order is emitted. When the steam pressure is too low, the valve is operated from a local source of compressed air. Manifold 1 Main piston l Manifold 2 Atmosphere Isolation valve opening function: Pilots opened and excited Isolation valve closing function: Pilots closed and deexcited Maintaining in open position: Pilots opened and excited Maintaining in closed position: Pilots closed and deexcited 3.2. DESCRIPTION OF CONTROL VALVE The VDA [MSRT] control valve is a power-operated wedge type globe valve welded into the relief line downstream of the VDA [MSRT] isolation valve. 3.3. FLOW DIAGRAM A simplified flow diagram [Ref-4] for the VDA [MSRT] is given in Sub-chapter 6.8 - Figure 1. 4. OPERATING CONDITIONS 4.1. SYSTEM NORMAL OPERATING STATE During power operation, the VDA [MSRT] isolation valves are closed and the control valves are open. This allows a faster system reaction to be achieved in the event of secondary side overpressurisation, because the isolation valve opening time is shorter than the control valve opening time.

PAGE : 7 / 13 4.2. SYSTEM OPERATING CONDITIONS When the reactor is in hot standby and the condenser is not available, the steam generated in the steam generators is discharged to atmosphere. During PCC-2 to PCC-4 events, the VDA [MSRT] controls the secondary pressure until the controlled stated is obtained. During PCC-2 events, anticipating condenser unavailability, steam is discharged to the atmosphere which enables LHSI connection conditions to be established in RRA [RHRS] mode. The rate of cooling is monitored. During PCC-3 or PCC-4 accidents (anticipating condenser unavailability), when depressurisation is required to reach MHSI injection conditions, the partial cooling procedure is initiated to cool the system at 250 C/hr and thus depressurise the primary cooling system. During PCC-3 or PCC-4 accidents (anticipating condenser unavailability), the VDA [MSRT] is used to establish LHSI connection conditions in RRA [RHRS] mode at 180 C to allow decay heat removal. 4.3. SYSTEM TRANSIENT STATES Transient states involving opening of VDA [MSRT] isolation valves are given in section 4.2. 5. PRELIMINARY SAFETY ANALYSIS 5.1. COMPLIANCE WITH REGULATIONS See Sub-chapter 1.4 5.2. COMPLIANCE WITH FUNCTIONAL CRITERIA The VDA [MSRT] is designed to remove decay heat to ensure that the fuel temperature remains below safety limits and the primary cooling system remains within its design conditions. The VDA [MSRT] is designed to ensure that the pressure in the steam generators does not exceed certain limits during PCC-2 to PCC-4 events and RRC accidents. Compliance with the pressure limits is discussed in section 1 of Sub-chapter 3.4. 5.3. COMPLIANCE WITH DESIGN REQUIREMENTS 5.3.1. Safety classification Compliance of the design, construction, materials and equipment with the requirements of the classification rules is described in detail in Sub-Chapter 3.2.

PAGE : 8 / 13 5.3.2. Single Failure Criterion See Sub-chapter 6.8 - Table 1. 5.3.3. Qualification The equipment is qualified in accordance with the requirements of Sub-chapter 3.4. 5.3.4. Instrumentation and control Compliance of the design and construction of instrumentation and control equipment with the requirements of the classification rules is described in Sub-chapter 3.2. 5.3.5. Emergency power supplies Following total loss of external electrical power supplies (LOOP), the VDA [MSRT] trains are backed up by the main diesel generator sets. In the event of a SBO [station blackout] event, VDA [MSRT] trains 1 and 4 are backed up by the emergency plant cooldown diesel generator sets.

PAGE : 9 / 13 5.3.6. Hazards The following tables summarise the hazards taken into account in the VDA [MSRT] design Internal hazards Pipe breaks Tank, pump and valve breaks Internal missiles Dropped load Internal explosion Fire Internal flooding Protection required in principle Yes, no more than one train affected Yes, no more than one train affected Yes, no more than one train affected Yes, no more than one train affected Yes, no more than one train affected Yes, no more than one train affected Yes, no more than one train affected General protection Separating the trains Specific protection introduced in the system design Break preclusion concept Separating the trains - Separating the trains (a single train affected) Exclusion via the handling equipment design Separating the trains - Separating the trains - Compartmentalisation - - - External hazards Protection required in principle General protection Earthquake Yes Location in two Safeguard Buildings Aircraft crash Yes Location in two Safeguard Buildings External explosion Yes Location in two Safeguard Buildings External flooding Yes Location in two Safeguard Buildings Snow and wind Yes Location in two Safeguard Buildings Extreme cold Yes Location in two Safeguard Buildings Electromagnetic Yes Location in two interferences Safeguard Buildings Specific protection introduced in the system design Seismic design Geographical separation of the train into two pairs Resistance to vibrations Design of compartment for the VVP [MSSS] - - - -

PAGE : 10 / 13 6. TESTS, INSPECTION AND MAINTENANCE The VDA [MSRT] safety classified components are subject to periodic testing. The functions to be tested are identified from accident studies. For each safety function the success criteria defined are the same as those assumed in the accident studies. The testing periodicity of all of the functions to be tested is justified by specific studies. The in-service inspection programme will be defined during the EPR detailed design phase. For each inspection area, it will be confirmed that there is adequate accessibility. In addition, it will be confirmed that the non-destructive test requirements are compatible with the component design and manufacture (surface finish, geometry, etc.). In addition, for any factory weld for which an inspection is planned, non-destructive tests will be carried out to provide an "initial inspection" status Periodic tests and Preventive Maintenance Programmes will be defined during the EPR detailed design phase.

PAGE : 11 / 13 SUB-CHAPTER 6.8 - TABLE 1: CONSEQUENCES OF SINGLE FAILURE Component Function Single failure Explanation Control valves Decay heat removal or cooling Opening fault Redundancy depends on the other VDA [MSRT] train SG depressurisation Opening fault Function is only required over the longterm. The redundancy depends on opening the conditioning line corresponding to the affected SG. Shutdown of the activity discharge during SGTR Closing fault Redundancy depends on the affected SG isolation valve. Isolation valves Decay heat removal or partial cooling Opening fault for any solenoid pilot valve No effect on the function due to the solenoid pilot valve configuration. Main valve opening fault Redundancy depends on the other VDA [MSRT] (SG) Isolated SG depressurisation Opening fault for any solenoid pilot valve No effect on the function due to the solenoid pilot valve configuration. Shutdown of the activity discharge during SGTR Main valve opening fault Main valve closing fault Function is only required over the longterm. The redundancy depends on opening the conditioning line corresponding to the affected SG. Redundancy depends on the affected SG control valve.

PAGE : 12 / 13 SUB-CHAPTER 6.8 - FIGURE 1: VDA [MSRT] SIMPLIFIED FLOW DIAGRAM

S PAGE : 13 / 13 SUB-CHAPTER 6.8 REFERENCES External references are identified within this sub-chapter by the text [Ref-1], [Ref-2], etc at the appropriate point within the sub-chapter. These references are listed here under the heading of the section or sub-section in which they are quoted. The following references are used throughout this sub-chapter: [Ref-1] System Design Manual Atmospheric Steam Dump System (VDA [MSRT]) - P1. NESS-F DC 624 Revision A. AREVA. December 2009. (E) [Ref-2] System Design Manual - Main Steam Relief Train - Part 2: System Operation, NESS-F DC 580 Revision A. AREVA. November 2009. (E) [Ref-3] System Design Manual - Main Steam Relief Train - Part 3: System Design. NESS-F DC 581 Revision A. AREVA. November 2009. (E) [Ref-4] System Design Manual - Main Steam Relief Train - Part 4: Flow diagrams. NESS-F DC 595 Revision A. AREVA. September 2009. (E) [Ref-5] System Design Manual Atmospheric Steam Dump System (VDA [MSRT]) P5 Instrumentation & Control. NESS-F DC 630 Revision A. AREVA. December 2009. (E)