Mount Holyoke College. Confined Space Program

Similar documents
Mount Holyoke College. Confined Space Program

CONFINED SPACE ENTRY PROGRAM FOR GOUCHER COLLEGE

CONFINED SPACE ENTRY PROGRAM

1.0 Scope and Application. 2.0 Definitions. Cal Poly Risk Management Confined Space Program Page 1

CONFINED SPACE ENTRY PROGRAM CSU CHANNEL ISLANDS

Confined Space Entry Program

Confined Space Entry Procedure

Confined Space Program

Safety Tips from the WorkSafe People. Building a Safety Program for Your Organization

TEXAS TECH UNIVERSITY HEALTH SCIENCES CENTER EL PASO

Key Technology, Inc. Confined Space Entry Program. July, 2017

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

CONFINED SPACE WRITTEN PROGRAM

Confined Space Entry Safety Program

Revisions Made? Yes No_X_

Confined Space. Program Responsibilities

Duke University - Facilities Management Department Environmental Safety and Health Program CONFINED SPACE PROGRAM

Illinois State University. Confined Space Entry Procedure

EH&S Program Occupational Safety Next Review: 5/9/19. Scope: University Wide Original date created: 2006

CONFINED SPACE PROGRAM

Confined Space Entry Program 8 CCR 5157

The Johns Hopkins University/The Johns Hopkins Hospital Health, Safety and Environment Manual Safety Policies:

Confined Space Entry

Confined Space Program

Environmental Health & Safety

State University of New York College at Oneonta

Confined Space Entry

1. Class "A" - an environment that is immediately dangerous to life of health. (Entry by permit only shall have a posted sign.)

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and

Safety Regulations and Procedures GENERAL SAFETY Confined Spaces - S New 11/96. To provide guidance for the safe entry of confined spaces.

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Confined Space Policy 11/21/14 Last Revision

Confined Spaces. County of Henrico Risk Management Loss Prevention October 2 nd 2013

Confined Space Entry Procedure Page 1

Salt Lake Community College

Once Printed This Document May No Longer Be Current

Original Date of Issue: 01/01/2009

Confined Space Plan Environmental Health & Safety Office July 2017

CENTRAL ZONE OPERATIONS MANUAL

PERMIT-REQUIRED CONFINED SPACES PROGRAM

Confined Space in Construction

CONFINED SPACE PROGRAM

CONFINED SPACE ENTRY

UNIVERSITY OF RHODE ISLAND DEPARTMENT OF SAFETY & RISK MANAGEMENT STANDARD OPERATING PROCEDURE

Confined Space Entry Program

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

SAFETY AND HEALTH STANDARD CONFINED SPACE ENTRY REQUIREMENTS Effective Date: 06/10/10 Standard: 16.2 Document Number: KUCSH0038 Rev: 07

APPLICIPABLE STANDARD: OSHA 29 CFR Confined Space Entry

Richland County School District One. Permit-Required Confined Space Entry Program (29 CFR Part )

CONFINED SPACE ENTRY PROCEDURE

Confined Space Entry Program

SECTION 9 CONFINED SPACES

CONFINED SPACES. American Galvanizers Association Phone: (720) Fax: (720) Scope

Marshall Municipal Utilities CONFINED SPACE ENTRY Effective January 1, 2011

Dutchess Community College. Confined Space Entry Program

Confined Space Entry Program

Confined Spaces. 1. Definition Permit/Non-Permit

An area may be considered a confined space if it meets three criteria.

29 CFR CONFINED SPACE ENTRY

Introduction to Confined Space Safety OR-OSHA

RISK ENGINEERING TECHNICAL GUIDE

Electrical Transmission & Distribution Partnership. Continuing Education Training Confined & Enclosed Spaces

CONFINED SPACE PROGRAM

Confined Space Management

THE CITADEL The Military College of South Carolina 171 Moultrie Street Charleston, SC MEMORANDUM 30 June 2017 NUMBER (X)-(Y) CONFINED SPACE

Confined Space Entry and Permitting

CONFINED SPACE PROGRAM

OREGON DEPARTMENT OF FISH AND WILDLIFE POLICY Human Resources Division

E n v i r o n mental Health & S a f ety

CONFINED SPACE POLICY

City of Montpelier, Vermont The Smallest Capital City in the United States CONFINED SPACES ENTRY PROGRAM

Prepared by: Date: Approved by: Date:

Confined space entry. In defining a permit-required confined space, the standard lists the following characteristics:

PERMIT REQUIRED CONFINED SPACE PROGRAM

CONFINED SPACE ENTRY PROGRAM (CSEP) OSHA Confined Spaces

DAMEWOOD CONSULTING GROUP

Confined Space for Construction

Program No Introducing hazards into Non-Permit Required Confined Spaces Atmospheric Testing

"CONFINED SPACE ENTRY"

Recommended Facilitator Notes: (read the following text out-loud to participants while showing this slide)

Confined Spaces OSHA 1926 AA

Table of Contents. Introduction (Scope, Purpose, Application)...2. Identifying Confined Spaces...2. Identifying Confined Space Hazards..

Confined Spaces. Risk Management Services

Confined Space Policy

Permit-Required Confined Spaces...29CFR

Confined Spaces PAGE 1

Instructions. To complete this independent study program, view the entire program, advancing through each slide by pressing the enter key.

Gettysburg College. Confined Space Program

Clear up confusion between the requirements for confined spaces and grain storage structures.

STANDARD OPERATING PROCEDURE

TAMPA ELECTRIC COMPANY ENERGY SUPPLY CONFINED SPACE PROGRAM

Risk Management and Safety (RMS) Confined Space Entry Program May 1, 2009

1 Purpose. 2 Responsibilities. 3 Policy Content ENVIRONMENTAL, HEALTH AND SAFETY STANDARDS. TITLE: CONFINED SPACE ENTRY Document Number: *

The following terms are defined for the purposes of this subpart only:

UNIVERSITY OF CONNECTICUT HEALTH CENTER POLICY AND PROCEDURES PERMIT-REQUIRED CONFINED SPACES (10/2000)

Corporation for Ohio Appalachian Development Corporation for Ohio Appalachian. Confined Space Awareness

Confined Space Entry Program

MONMOUTH UNIVERSITY POLICIES AND PROCEDURES. Original Issue Date: Unknown Revision Date: February 10, 2012

The following were determined to be confined spaces; they may not be permit required that employees of the Division of Facilities may encounter:

Town of Morehead City. Permit Required Confined Space Entry Program

Confined Space Entry Policy

Transcription:

Mount Holyoke College Confined Space Program November 2014

In Compliance with the OSHA 29 CFR 1910.126 Environmental Health, Safety & Sustainability 413-538-2529

Mount Holyoke College CONFINED SPACE PROGRAM TABLE OF CONTENTS I. Purpose 1 II. Definitions 1 III. Confined Spaces on Campus/Authorized Employees 2 IV. Identifying Permit Required Confined Space Hazards 3 V. Equipment 4 VI. Procedures for Working in a Non-Permit Required Confined Spaces 4 VII. Procedures for Working in a Permit Required Confined Spaces 6 VIII. Emergency Procedures 8 IX. Contractor Entry 8 X. Training 9 XI. Records 9 XII. Annual Program Review 10 Attachments Industrial Scientific M40 Multi-Gas Monitor Basic Operating Instructions Confined Space Entry Permit

MOUNT HOLYOKE COLLEGE CONFINED SPACE PROGRAM I. PURPOSE This Program is designed to identify and control potential hazard of working in confined spaces on campus by establishing procedures for confined space entry in compliance with 29 CFR 1910.146, OSHA Permit Required Confined Space Standard. II. DEFINITIONS A Confined Space is a space that has all of the following characteristics: is large enough and so configured that a person can bodily enter and perform assigned work has limited or restricted in its means of entry or egress is not designed for continuous occupancy A Permit Required Confined Space is a confined space that has one or more of the following characteristics: contains or has the potential to contain a hazardous atmosphere contains a material with the potential to engulf someone who enters the space has an internal configuration that might cause an entrant to be trapped or asphyxiated by inwardly converging walls or by a floor that slopes downward and tapers to a smaller cross section contains any other recognized serious safety or health hazard, examples include: fall hazards unguarded machinery extreme hot or cold live steam pipes gas lines electrical hazards combustion sources hazards introduced to the space (e.g., welding, chemical use) Entry means any part of the entrant s body breaking the plane of an opening into a confined space. 1

III. CONFINED SPACES ON CAMPUS/AUTHORIZED EMPLOYEES A. Non-Permit Required Spaces A Non-Permit required confined space is a confined space that does not contain, or have the potential to contain, any hazard capable of causing death or serious physical harm. Examples may include interiors of HVAC units, certain air plenums, attics, and some building crawl spaces. Entry into Non-Permit required spaces requires atmospheric testing prior to and during entry to ensure the space is, and remains, free of atmospheric hazards. General work safety practices must be adhered to including presence of an attendant and use of barriers to ensure the safety of others in the area. Areas that have been classified as Non-Permit, may be reclassified as Permit-Required if hazards are being introduced to the space (e.g., welding, chemical use) or unusual conditions have changed the hazards of the space (e.g., toxic atmosphere, water infiltration). B. Permit Required Confined Spaces Entry into Permit Required Confined Spaces requires that a valid Entry Permit be in place. Requirements for Entry Permits are detailed in section VII. Examples of Permit Required confined spaces on campus include: Boilers: waterside and fireside Hot water tanks at the Central Heating Plant and in campus buildings Manholes: any space accessed by lifting a manhole cover Mechanical Crawl Spaces: e.g., Carr, Kendade Shattuck, Williston Library, Mary Lyon, Pratt, Torrey and Betty Shabazz Elevator Pits and Shafts Certain Attics: e.g., Dwight Facilities Management maintains a list of all Permit Required confined spaces on campus and ensures that spaces are identified by signs or, in the case of manholes, on a map posted at the Otto Kohler Building and the Central Heating Plant. C. Authorized Employees Only employees who have been trained under the confined space program may enter any confined space or serve in any other capacity in support of entry (e.g., attendant, entry supervisor). Trained employees in the following Facilities Management trades are authorized to participate in entries: Plumbing, HVAC, Electrical, Central Heating Plant. 2

The following Facilities Management employees are authorized as Entry Supervisors: Associate Director and Chief Engineer, Plumbing Supervisor, Electrical Supervisor, HVAC and Central Heating Supervisor, or his/her designee. The Entry Supervisor cannot be an entrant or attendant. IV. IDENTIFYING PERMIT REQUIRED CONFINED SPACE HAZARDS A. Hazardous Atmosphere The following parameters are used to define a "Hazardous Atmosphere". Atmospheric oxygen concentration below 19.5 percent or above 23.0 percent. At 16% most people will show signs of respiratory distress, light-headedness, mental confusion. Above 23% the risk of fire and explosion increases rapidly. Flammable gas, vapor, or mist more than 10 percent of its LEL. LEL is the Lower Explosion Limit (also sometimes known as the Lower Flammability Limit, LFL). It is the lowest concentration in air at which ignition can occur. The UEL is the Upper Explosion Limit above which ignition will not occur. The flammable range is the range between the LEL and UEL. Carbon Monoxide more than 35 parts per million. Carbon monoxide is the most common cause of chemical poisoning deaths. It is a chemical asphyxiant that prevents blood from transporting oxygen. The alarm level of 35 ppm is the 8-hour time weighted average OSHA Permissible Exposure Limit. Hydrogen sulfide more than 10 parts per million. Hydrogen sulfide is toxic and explosive. The LEL is 4% and the UEL is 44%. The 8-hour OSHA Permissible Exposure Limit is 10 ppm. The Immediately Dangerous to Life and Health (IDLH) concentration is 300 ppm. Hydrogen sulfide has a distinct odor that can be detected at 0.0002 ppm. The toxic effects are, however, on the nervous system; the nerve responsible for smell quickly becomes fatigued, therefore, odor, or lack of odor, should not be used as a warning sign. Eye and nasal irritation are more persistent. Airborne combustible dust at a concentration that meets or exceeds its LEL (approximately a dust that obscures vision at a distance of 5 feet or less). B. Other Confined Space Hazards engulfment including potential for rising water, sewage, or landslide configuration/entrapment (spaces that narrow or have obstructions that might cause a person to become stuck) fall hazards of 6 feet or more 3

unguarded machinery or mechanical hazards such as rotating or moving mechanical parts extreme temperatures including either high or low atmospheric temperature in the space or hot objects in the space live steam lines gas lines with valves or other devices that could release gas if they fail electrical hazards including exposed electrical voltages more than 120 volts combustion sources due to potential for combustion gases introduced hazards such as welding or chemical use V. EQUIPMENT Two Industrial Scientific M40 four gas (oxygen, flammable gas, carbon monoxide, and hydrogen sulfide) meters are available for testing confined spaces. Basic instructions for the meter are included at the end of this Program. The meters are: stored at Central Heating Plant only available to employees trained under this Program signed out including: employee name, date, time, and location of use maintained by the Central Heating Plant Engineers The meters are kept in a M-Cal station for charging, calibration and bump testing. Barriers, air blower, retrieval tripod and other confined space equipment are also kept at the Central Heating Plant. Kendade mechanical room is equipped with escape breathing apparatus, for use to immediately exit the area should the refrigerant release alarm sound. These respirators are inspected and maintained by the Facilities Management Plumbers. VI. PROCEDURES FOR WORKING IN A NON-PERMIT REQUIRED CONFINED SPACE Only employees who have completed training for this Program are authorized to enter a confined space or serve as an attendant. An attendant is required for all work in non-permit required confined spaces. A. Pre -Entry 1. Pick-up test equipment and a Confined Space Entry Permit at the Central Heating Plant. Prior to removing from the M-Cal station, perform a bump test on the meter by holding the BUMP button for 2 seconds. A passed bump test is indicated by a flashing 4

green light. A failed bump test is designated by a flashing red light. If the bump test fails, the meter requires calibration or repair and cannot be used. Record the bump test and removal of the test equipment on the Instrument Log. 2. Complete the following pre-entry tasks Identify the Entry Supervisor (see Section IIIC) and complete Section 1 of the Entry Permit gather required equipment erect pedestrian and/or vehicular barriers as needed eliminate any condition that makes it hazardous to open the space open the space without entering the space, make a visual inspection for potential hazards without entering the space, test for atmospheric hazards using the test meter and record the results ensure communication system for summoning emergency assistance is available complete Section 2 of the entry permit 3. Rescue Services Notification During regular office hours, prior to entry, the Entry Supervisor must notify the Facilities Management Office of the entry location and estimated entry time and duration of entry. The Office will notify South Hadley Fire District #2. After hours, the Entry Supervisor is responsible for notifying South Hadley Fire District #2. 4. Determine if the space is a Non-Permit Required Space or needs to be reclassified. If any level of atmospheric contaminant is detected or any other hazard is detected, the space must be reclassified as a Permit Required Confined Space. B. Entry An attendant must be present for all work in confined spaces, Permit and Non-Permit required. Assuming the space remains classified as Non-Permit Required, enter the space continuing to do atmospheric testing while in the space and complete the needed task. If atmospheric or other hazards develop while in the space, exit immediately and reclassify as Permit Required. The entry must be terminated and the space immediately evacuated if atmospheric or other hazards develop during entry. The space must then be reclassified as Permit Required and a new permit process initiated. 5

C. Entry Termination After the necessary work is complete, remove all tools, exit the space, and secure the entry point from unauthorized entry. VII. PROCEDURES FOR WORKING IN A PERMIT REQUIRED CONFINED SPACES Only employees who have completed training for this Program are authorized to enter a confined space or serve as an attendant. An attendant is required for all work in permit required confined spaces. A. Pre-Entry 1. Pick-up test equipment and a Confined Space Entry Permit at the Central Heating Plant. Prior to removing from the M-Cal station, perform a bump test on the meter by holding the BUMP button for 2 seconds. A passed bump test is indicated by a flashing green light. A failed bump test is designated by a flashing red light. If the bump test fails, the meter requires calibration or repair and cannot be used. Record the bump test and removal of the test equipment on the Instrument Log. 2. Complete the following pre-entry tasks identify the Entry Supervisor (see Section IIIC) and complete Section 1 of the Entry Permit gather required equipment erect pedestrian and/or vehicular barriers as needed eliminate any condition that makes it hazardous to enter the space open the cover or other closure device without entering the space, make a visual inspection for potential hazards without entering the space, test for atmospheric hazards using the test meter and record the results implement controls, such as lockout/tagout to isolate identified hazards obtain a Hot Works Permit if applicable if the space is a sewer pit, a hazard will be introduced (e.g., hot work operations, or chemical use), or a hazardous atmosphere is detected, a forced ventilation system must be setup o care must be taken to insure that the air intake to the ventilation system is safe from contamination and that the ventilation is directed toward the employee's work area in the confined space 6

o if ventilation is required, set up ventilation and retest atmosphere (acceptable results must be sustained for at least 10 minutes prior to entry) for all vertical entries, the retrieval system (tripod and harness) must be used for all boiler entries, anklets must be used ensure a communication system for summoning emergency assistance is available complete Section 2 and 3 of the Entry Permit entry supervisor reviews 3. Rescue Services Notification During regular office hours, prior to entry, the Entry Supervisor must notify the Facilities Management Office of the entry location and estimated entry time and duration of entry. The Office will notify South Hadley Fire District #2. After hours, the Entry Supervisor is responsible for notifying South Hadley Fire District #2. B. Entry Permit After Section 2 and 3 of the Entry Permit is complete, the Entry Supervisor reviews the permit information and site conditions and either issues an Entry Permit, Section 4, or determines that additional testing or precautions are needed and supervises those efforts. If the Entry Supervisor determines that the space cannot be safely entered, the Entry Permit is denied and the space cannot be entered. C. Entry For all entries, the meter must be carried in to the confined space by one of the entrants, or operated remotely by the attendant during the entire entry. Record all entrant entries and exits and changes in attendant in Section 5 of the Entry Permit. The Entry Permit must remain on-site throughout the entry. Should the test equipment sound a warning alarm during entry all employees must exit the space immediately and the entry is terminated. Record the Termination for Cause in Section 6 of the Entry Permit. Prior to reentry a new Entry Permit must be issued restarting all entry procedures. If additional action is needed to control hazards once the space is entered, take that action immediately upon entry. The escape respirator must be carried into the Kendade mechanical crawl space. 7

D. Entry Termination After the necessary work is complete, remove all tools, exit the space, and secure the entry point from unauthorized entry. If the space is being ventilated, all employees must leave the confined space before the ventilation system is turned-off. Complete Section 6 of the Entry Permit and give the Permit to the Entry Supervisor for review. E. Duties of the Attendant maintains an accurate count and identification of authorized entrants in the space remains outside the space during entry until relieved by another attendant monitors conditions inside and outside the space maintains communication with entrants notifies entrants to leave the space if conditions become hazardous or if entrants show signs of overexposure to hazardous conditions calls for emergency personnel or other support if needed VIII. EMERGENCY PROCEDURES The College has an agreement with South Hadley Fire District #2 for emergency rescue services. Should rescue services be required or other health emergency occur, immediately contact Campus Police (ext. 1911 from a campus phone, 413-538-2304 from a cell phone) to request services. IX. CONTRACTOR ENTRY If Mount Holyoke College hires a contractor for work in a confined space the following tasks should be performed. 1. All contracts for work to be done in a space identified by the College as a confined space will include the explicit requirement that the work be done according to a confined space program meeting the requirements of 29 CFR 1910.146. 2. The College must tell the contractor of any known hazards in the space and provide the contact information for South Hadley Fire District #2 so that the contractor can give pre-entry notification and call for emergency services if needed. 8

3. Contractors must supply their own equipment and make their entry record or permit available upon request. 4. The College supervisor for that work area will inform the contractor of: any known hazards in the space results of any testing done to detect these hazards Recommended procedures in use to control any potential hazards 5. If both College employees and a contractor will be entering a space, College procedures will be used for College employee entry and contractor procedures will be used for contractor employee entry. An attendant may be shared if s/he is aware of College emergency notification procedures. X. TRAINING Employees will be trained: at the start of this Program after that time for new and transferred employees before entering a confined space or serving in any other capacity under this program if program review finds the need for additional training when changes in the Program, test equipment, or list of confined spaces warrant additional training The training program will consist of: the hazards associated with working in confined spaces a review of the Mount Holyoke College Confined Space Program and the OSHA Permit-Required Confined Space Standard how to complete the Instrument Log, and Confined Space Entry Permit how to use the atmospheric test equipment how to use other program equipment (barriers, communication equipment etc., escape respirator) procedures for confined space entry emergency procedures XI. RECORDS The Entry Permit will be kept at the work site. After completion of the entry these documents will be completed and given to the Entry Supervisor for review. 9

Completed Permits will be maintained in a separate program file in the Facilities Management Office. The Instrument Log will be maintained at the Central Heating Plant as part of the sign-out procedure. Instrument calibration records are kept on the Instrument Log. The Instrument Log will be collected annually and added to the program file for that year at the Facilities Management Office. All Permits, Instrument Logs, and other program records will be kept for at least one year after their annual review. Training records will be kept in the Environmental Health, Safety & Sustainability Office. XII. ANNUAL PROGRAM REVIEW Once a year, the Facilities Management Associate Director (or his designee) will review the Confined Space Entry Program. The review will include at least the following procedures: reviewing the records for the past year for completeness and adherence to the written Program determining the need for Program modification or training determining the need for new equipment determining whether additional spaces should be classified as Permit Required Confined Spaces or whether identified spaces can be removed from the Program 10

Industrial Scientific M40 Multi-Gas Monitor Basic Operating Instructions Manufacturer s instructions are available at the Central Heating Plant. Manufacturer s instructions should be read before using the monitor for the first time. 1. Prior to removing the meter from the M-Cal Calibration Station, perform a Bump Test by holding the BUMP button for 2 seconds. A green light will flash if the test is passed, a red if it is not. If it doesn t pass the meter must be calibrated or repaired before use. 2. Turn the meter on - push the mode button (inner left) for 1 second The display will do a self-test (you will see some symbols and numbers flash) Next, the display will show a 20-second countdown When the countdown is complete, the meter will automatically go into normal gas detection mode. The main display screen will look something like this: 0 CO 0 H 2 S 20.9 O 2 0 LEL The lower left corner of the display will show a battery icon indicating battery life - (the meter will beep periodically to warn you when there is only 10 minutes of battery life remaining EXIT THE SPACE) 3. At this point, the meter is working, but zeroing the sensors is recommended: Press the up arrow button, (outer right), once. You will see a symbol like this: ø Press the enter button (inner right) While it is zeroing, the display will show a clock icon and the full span of the oxygen sensor When it s done zeroing, you ll see the calibration icon (which looks like a gas cylinder with a hose) and the enter key icon (which looks like an arrow pointing down and to the left) Push the mode button (inner left) once to return to normal das detection mode 4. The meter has an internal pump attached. Test the space before entry by attaching tubing to the pump and lowering tubing into the space Allow at least 2 seconds per foot of tubing 5. Enter the space only after determining it is safe the meter must be carried at all times while in the space 6. If the alarm goes off at any time while you are in a confined space, EXIT IMMEDIATELY To turn the meter off, press and hold the mode button for 5 seconds. You will see a flashing H, meaning hold. The unit will beep 5 times, and then shut off.

Date: Section 1: GENERAL INFORMATION LOCATION OF SPACE: PURPOSE FOR ENTRY: ENTRY SUPERVISOR: Rescue Personnel: South Hadley Fire District 2 - Call 413-538-2304 to notify of entry Section 2: INSPECTION and CLASSIFICATION TIME OF INITIAL INSPECTION: MOUNT HOLYOKE COLLEGE CONFINED SPACE PROGRAM Confined Space Entry Permit VISUAL INSPECTION (describe conditions): TEST RESULTS: O2 >19.5 <23 LFL CO H2S <10% <35ppm <10ppm Is this a Non-Permit Required Confined Space? Yes It Does not contain atmospheric, engulfment, entrapment, fall hazard of > 6 feet, mechanical hazards, water infiltration, extreme temperatures, live steam lines, gas lines with valves or other devices that could release gas upon failure, electrical hazards, combustion sources, introduced hazards such as welding or chemical use or any other hazard capable of causing death or serious physical harm. If yes, continue atmospheric testing while in the space and erect barriers as needed to protect others in the area. If an atmospheric or other hazard develops during entry, immediately exit and reclassify the space as permit required. This space has been evaluated and classified as Non-Permit Required. Entry Supervisor Signature: Date/Time: No If no, proceed with control measures and complete the Entry Permit process. Section 3: CONTROL MEASURES EQUIPMENT IN PLACE Retrieval System (all vertical entries) Other (describe): Barriers GFCI for all electrical equipment Communications Equipment Personal Protective Equipment SPACE ISOLATION/HAZARD CONTROL PRIOR TO ENTRY ELECTRICAL LOCKOUT/TAGOUT HOT WORK PERMIT MECHANICAL LOCKOUT/BLOCKOUT OTHER (describe): Area Secured VENTILATION REQUIRED SPACES Time Ventilation Equipment Put in Place: Ventilation Power Source Secured from Tampering: Yes Introduced Hazards: SEWER Hot Work Chemical Other (describe): Time of Initial Retest: Time of Final Retest: RETEST RESULTS: O2 >19.5 LFL <10% CO <35ppm H2S <10ppm RETEST RESULTS: <23 O2 >19.5 <23 LFL <10% CO <35ppm H2S <10ppm Acceptable Results must be sustained at least 10 minutes prior to entry. Section 4: ENTRY PERMIT I have reviewed the work authorized by this permit and all conditions have been satisfied. Entry is approved. Continuous Air Monitoring is required throughout entry. Should any conditions change, all personnel must exit the space and a new permit must be issued. Entry Supervisor Signature: Date/Time: (continue on back side)

Section 5: ENTRY ENTRANTS LOG: Name Time In Time Out ATTENDANT LOG: Name Time On Time Off Section 6: TERMINATION Termination for Cause: Time: Describe Reason: (all entrants out) If TERMINATED FOR CAUSE, A NEW Permit must be issued before reentry. Task Complete (all entrants out): Time: Space Secured and Equipment Inspected and Returned: Entry Supervisor Review: Signature: Time: Date: Section 7: NOTES EH&S 10/2014