Krantz Components. Multifunction sail AVACS. Cooling and heating systems

Similar documents
Krantz Components. Multifunction Sail AVACS. Cooling and Heating Systems

Air distribution systems Circular displacement outlet with adjustable damper VA-ZD...

for Asia / Pacific Radial outlet RA-N3... DS 4134 AUS /

Barcol-Air BRM Radiant Module

CHILLED BEAM FLEXICOOL IQID

LindabSolus. Supply air beam. lindab we simplify construction

Round duct nozzle jet diffuser Model DSA-RR

Chilled beam iq Star WEGA II

Adjustable swirl diffuser ODZA TECHNICAL DATA

Supply air diffuser ROFB, RPFB

Evolution. Radiant Panels. Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

LindabPremum. Supply air beam. lindab we simplify construction

vento specification sheet

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE

TECHNICAL DESCRIPTION

Series Environmental Chambers

Automatic balancing valves

LindabPremax. Supply air beam. lindab we simplify construction

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Automatic extractor outlet

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

AIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS

LindabArchitect. Supply air beam

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Industry Guidelines POLYETHYLENE (PE) PIPES AND FITTINGS FOR COMPRESSED AIR ISSUE 6.8

Two-port valves, male threaded, PN25

Krantz Components. Displacement ventilation for indoor firing ranges. Air distribution systems

Technical Documentation Linear diffusers series LDB

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Gas Cylinder Cabinets

Instruction Manual. Pipe Friction Training Panel

Gas Pressure Regulator HON 300

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Electronic Turbine Meter TERZ 94

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

CEILING DIFFUSERS technical CONTROL THE AIR YOU BREATHE. types -CD, CAB. Europair Africa a division of Performancair Products Africa (Pty) Ltd

Technical Data Sheet TI-F50 Locking Units series KFH

Type 4708 Supply Pressure Regulator

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Calculation tables for thermal expansion.

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Materials : Galvanized steel flanges

Evaporator (DX) Freon Applications 1 12 Tons MHF

differential pressure regulating valve - threaded

Expansion Vessels for Potable Installations

Connecting hoses. Type FS. Connecting hoses for the water-side connection of air- water systems and decentralised ventilation units PD FS 1

Differential Pressure Control Valve (DPCV)

Materials : Electro galvanized steel flanges

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Experiment Instructions. Circulating Pumps Training Panel

Pneumatic spool valve islands

SonoMeter 30 Energy Meters

Remeha Quinta Cascade guide

Automatic balancing valves ASV

BARCOL-AIR RADIANT WAVE (BRW) Your Wave Radiant Cooling or Heating RADIANT WAVE

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Automatic balancing valves ASV

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10

WP2 Fire test for toxicity of fire effluents

Cim 787 Variable orifice balancing valve

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

GUMMIKOMPENSATOR GKF8000 / GKF8130

Panel diffuser ELASTOX -P

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Dimensioning open-close, control and pressure-independent valves. Table of contents. General notes for project planning

EnerVal. Technical data litre storage capacity. Buffer storage vessels

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

RMG Meßtechnik GmbH. Publication No E

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Valve Proving System VDK 200 A S06*

Installation, use and maintenance instructions. Gas burner (5)

acculink platinum zv zoning system

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

Pneumatic high-pressure controller Model CPC7000

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

GAS PRESSURE CONTROL UNIT TYPE 132

BUCKET ELEVATORS 1 BUCKET ELEVATORS. Technical Data for Bucket Elevators (BW)

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

HORIZONTAL BLADDER TANK

Type 4708 Supply Pressure Regulator

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

deltaflowc deltaflowc Venturi or Probe

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

Mass Flow Controller (MFC) for Gases

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

BiboBlock. Fall arrest system for flat roofs

Transcription:

Multifunction sail AVACS Cooling and heating systems DS 4170 E 01.2014

Preliminary remarks and construction design Preliminary remarks The multifunction sail AVACS is designed for use with plane metal acoustic sails from various brands to make cooling or heating sails. The large-surface permanent contact between the cooling element and the ceiling panel is preferably done by bonding. AVACS stands for Air Ventilation And Cooling System. The AVACS multifunction sail combines the following functions: cooling, heating, indoor air circulation and sound absorption, which are performed in compliance with thermal comfort criteria. There are a number of configurations available, e.g. made up of one or several pieces rigid or pull-down design with or without supply air distribution optionally with return air extraction optionally fitted with inspection element for maintenance of control valves installed by the client. AVACS multifunction sails come into use in offices, meeting rooms, foyers, exhibition rooms, libraries and such like, and serve to remove medium cooling loads. Construction design A multifunction sail AVACS consists of: one or several perforated metal ceiling panels copper serpentine pipework (copper tube from a coil) with connection ends for water inflow and outflow aluminium heat conducting profiles for fixing the serpentine pipework and creating a large contact surface area to the sail element steel crossbars for suspending the sail element an induction unit an optional return air diffuser. The multifunction sail can be optionally fitted with sound absorbers. The induction unit is fixed to the sail on site using two sheet metal screws (or rivets). As standard it is fitted with an oval spigot for flex duct DN 125. The induction unit discharges about 70% of the supply air above and 30% below the sail, thus circulating a large volume of indoor air and ensuring a continuously comfortable thermal environment. The induction unit has been engineered such that the cooler supply air from outside does not drop as is the case with displacement air outlets, but rather flows almost horizontally along the underside of the AVACS sail as a result of the Coanda effect. The pipework connections are preferably designed for push-in fittings; their shapes and positions are adapted to the required ceiling design and function, e.g. pull-down design lengthwise. For the serpentine pipework we use only quality-controlled copper tube. The sails can incorporate lights, air diffusers, loudspeakers and such like. Fig. 2 shows the structure of a multifunction sail as installed. This sketch suggests that the induction unit is connected to a flex duct, the sail elements are fitted with push-in fittings and flexible hoses, and are grouped, the access to the ceiling plenum and the pipes, ducts and cable conduits, etc., inside the plenum is not hindered by the AVACS sails. The versatility of the multifunction sail AVACS on the one hand and the high level of manufacture of metal sails to the German industrial standard TAIM on the other hand provide a good basis for the selection of sail elements from different manufacturers. By providing expert advice on technical selection and supplying the whole water system fitted within the sail area, provide reliability of the air-conditioning performance of the multifunction sails AVACS as well as a comprehensive air-handling solution. The main dimensions of a multifunction sail are given in Fig. 1. Further technical data is contained in Table 1. Multifunction sails AVACS can have various dimensions and designs, and be made of different materials; they are designed for specific parameters and meet different performance and sound absorption requirements. This is made possible by: the free choice of pipe length variable pipe spacing sound absorbers different types of connection to air ducts and water pipes. For sound absorption, acoustic lining is bonded to the whole rear side of the perforated ceiling panel except the area of the induction unit. As the contact surface areas of a sail element cover only part of the area available, the sound-absorbing effect is kept. The acoustic lining also provides unity of appearance of the ceiling panel from below. The induction unit, which generates a uniform and constant air stream above and below the sail, is invisible from the room side. www.krantz.de DS 4170 E p. 2 01.2014 The variable pipe spacing enables to purposely influence the cooling output and the sound-absorbing properties of the sail. Owing to the good thermal conduction in sheet metal and/or aluminium sheet, the whole area of an active sail is effective for heat transport. As standard, the contact between the cooling element and the ceiling panel is done by bonding; an option with barium and ferrite magnetic strips for permanent contact is also available. 2

Dimensions D H h D 6 7 8 3 9 1 5 2 4 B L/2 L/2 L Section D-D B Key 1 Aluminium contact profile 2 Copper serpentine pipework 3 Fastening crossbar 4 Connections for water supply and return 5 Ceiling panel, perforated, covered with acoustic lining 6 Induction unit 7 Flex duct 8 Sound absorbers 9 Connection hoses L = length of multifunction sail B = width of multifunction sail H min = minimum suspension height T = spacing of serpentine pipework Fig. 1: Multifunction sail AVACS www.krantz.de DS 4170 E p. 3 01.2014 Table 1: Main dimensions and materials Standard Ceiling panel sheet metal s = min. 0.7 mm, perforated, hole ø 2.5 mm, approx. 16% open area; powder coated Serpentine pipework copper tube 12 x 0.4 mm 1) Contact profile aluminium profile, width b = 80 mm 1), length matching serpentine pipework Fastening crossbar 2.0 mm sheet metal Connection ends for push-in fittings ø 12 mm + 0.05 / mm 1) Fittings: 90 bend 1) inclined at approx. 20 90 to the ceiling plane 180 bend Pipe spacing T variable, matching the sail dimensions for optimum performance Standard nominal length L 1 500 mm L 5 500 mm 1) Standard nominal width B 1 150 mm 1) Nominal height h 50 mm 1) Minimum suspension height 150 mm Allowable operating pressure 6 bars 1) (up to 16 bars is possible) Weight approx. 8 kg/m 2 of sail area (when filled with water, depending on pipe spacing) plus 3.4 kg for induction unit Total weight depends on ceiling design and ceiling services, etc. 1) Other types/values subject to enquiry 3

Layout data 11 9 3 6 7 8 S 4a 4b 10 12 Key 3 Crossbar for sail suspension 4a Chilled water supply pipe 4b Chilled water return pipe 6 Induction unit 7 Oval flex duct DN 125 8 Sound absorbers (optional) 9 Flexible hoses for connecting sail elements 10 Sail with copper serpentine pipework 11 Threaded rods 12 Flexible hoses for sail connection to water pipework S = Spacing between 2 sails, minimum spacing S min = 150 mm Fig. 2: Example of arrangement of multifunction sails AVACS in a room Layout data The standard cooling output of the AVACS sail was determined to EN 14240 (Chilled ceilings Testing and rating); it achieves values up to 165 W/m 2 (at 10 K). The tests were carried out on the following sail design: Ceiling panel made of perforated sheet metal (s = 0.7 mm) with acoustic lining (mainly cellulose, 0.25 mm thick, 60 65 g/m 2 ); perforation pattern: round straight perforations 2.5 5.5 / A 0 ~ 16% Suspension from ceiling: 150 mm with crossbars consisting of steel U-profiles Heat conducting profiles bonded to the ceiling panel using highperformance adhesive tape Sound absorbers on the rear side, 50 x 50 mm x nominal length of ceiling panel. The sail used for layout and determination of cooling output was a 2-piece multifunction sail having an overall length of 3 400 mm and an overall width of 900 mm. The specific cooling output measured with reference to EN 14240 amounted to 125 W/m 2 at a temperature difference of 8 K and a supply air volume flow rate of 28 l/s [100 m 3 /h] above and below the sail (see Graph A). The reference surface area is always the active area of the sail (as per Fig. 1). In reality several conditions that also influence the output differ from those in the test room to EN 14240, among others: the convective heat transfer at the sail surface when turbulent mixing ventilation is generated by ceiling diffusers, the exchange of radiant heat when room walls have higher surface temperatures, or the heat transfer on the rear side when insulation and ventilation above the sail are changed. In practical usage these differences mainly result in increased output. Having carried out numerous laboratory tests we are able to assess such influences, yet exact statements can be made only after laboratory tests performed under conditions close to reality. The maximum waterside pressure drop (30 kpa) of the cooling elements depends on their dimensions and the chilled water flow rate. www.krantz.de DS 4170 E p. 4 01.2014 4

Layout data Cooling output and pressure drop can be determined using selection software (see example in Fig. 4). If you wish so, the selection of the AVACS multifunction sails can be carried out by our product specialists. If you have special wishes regarding system design, materials or specific conditions of use, consult our specialists. Specific cooling output in W/m 2 300 200 100 1 = KKS-3/LD AVACS with 28 l/s [100 m³/h] 2 = supply air (18 C) 3 = supply air (18 C) 4 = recirculated air (26 C) 5 = recirculated air (26 C) 5 4 3 2 1 Specific heating output in W/m 2 400 300 200 100 Sound absorption without additional sound absorbers with additional sound absorbers 0 3 5 10 15 20 25 Linear temperature difference in K Graph B: Specific heating output of multifunction sails AVACS to EN 14037 (here with 28 l/s [100 m 3 /h] supply air; supply air temperature 20 C) www.krantz.de DS 4170 E p. 5 01.2014 Sound absorption (AVACS) without additional sound absorbers with additional sound absorbers 0 3 5 10 15 Linear temperature difference in K Graph A: Specific cooling output of multifunction sails AVACS to EN 14240 Sound absorption coefficient 1.0 0.8 0.6 0.4 0.2 Sound absorption without additional sound absorbers with additional sound absorbers 0 100 200 300 400 500 1 000 2 000 3 000 5 000 Frequency in Hz Graph C: Sound absorption measured on a multifunction sail AVACS fitted with acoustic lining, perforation pattern Rg 2516 5

Layout example Height in m 3 2 Position Y Average air velocity in m/s Turbulence intensity in % Air temperature in C < m/s 0.21 m/s m/s % C 0.11 49% 25.1 0.12 44% 24.8 0.09 58% 25.1 0.14 56% 24.7 0.15 53% 24.9 0.06 24.7 38% 25.0 0.08 56% 24.7 0.09 57% 25.0 51% 24.8 44% 25.1 < 0.05 24.8 1 m/s % C 0.09 56% 25.1 47% 24.5 25.2 0.13 50% 24.5 0.12 25.1 0.06 24.4 m/s 0.09 0.12 0.12 0.12 0.12 0.06 0.06 0.08 0.08 0.07 0.06 < 0.05 % 58% 56% 38% 53% 41% 58% C 24.6 24.8 24.6 24.8 24.6 24.8 24.7 24.8 24.7 24.9 24.9 24.9 m/s 0.07 0.14 0.13 0.13 0.05 0.05 0.09 0.07 0.09 0.09 0.07 % 54% 42% 34% 3% 40% 59% 42% 0 0 C 24.5 24.1 24.6 24.1 24.6 24.1 24.6 24.1 24.6 24.2 24.6 24.1 1 2 3 4 5 6 Position X in m Fig. 3: Indoor air flow measurements 31% 25.2 0.08 49% 24.5 0.12 31% 25.3 0.09 51% 24.5 0.12 37% 25.3 < 0.05 24.5 Layout example (cooling mode / heating mode) The achievable active area of a multifunction sail AVACS depends on the total sail area which must be geared to the room configura- tion. The specific cooling output is dependent on the active cooling area, the supply air volume flow rate and the waterside parameters. This can be seen in the following example (Fig. 4). AVACS Total output 280 Project: Cooling: 665 W Heating: 678 W 270 260 Input: 100% 0 W 250 240 230 Sail length: 3.2 m 90% 220 Sail width: 1.15 m 210 200 Number of single elements: 2 80% 268 W 190 Sound absorbers: none 180 70% 170 Design without induction unit: no 160 Length of connection hose: 1000 mm 150 60% 140 Layout: Cooling + Heating Airside output 130 Pipe spacing: opt. 120 50% 678 W Waterside output 110 Outside diameter of pipes: 12 mm 100 Cooling: Heating: 40% Water supply temperature: 17 38 C Water return temperature: 19 32 C 30% 397 W Room temperature: 26 20 C Supply air flow rate: 28 19 l/s [100] [70 m³/h] Supply air temperature: 18 20 C Pipe spacing: 95 mm Pipe connection: 180 Connection: on one side Sail area: 3.68 m² Active area: 3.24 m² Numb er of pipe rows: 12 (Heating mode isothermal) Cooling: Heating: Mean water temperature: 18 35 C Temperature difference: 8 15 K Waterside output: 397 W 678 W Airside output: 268 W 0 W Total output: 665 W 678 W Specific output (A akt.): 123 W/m² 209 W/m² Sound power level: 35 24 db(a) Pressure drop, air: 30 15 Pa (related to oval spigot 158 x 70 mm) Water flow rate: 171 97 l/h Flow velocity: 0.48 0.27 m/s Pressure drop, water: 18 7 kpa 179 72 mbar Fig. 4: Layout example Sound power level L WA in db(a) ref. 10-12 W 20% 10% 0% 50 40 30 Air volume flow rate in l/s 12 14 16 18 20 22 24 26 28 30 32 34 36 38 28 l/s [100m³/h] Cooling 19 l/s [70m³/h] Heating 80 70 60 50 40 20 20 40 50 60 70 80 90 100 110 120 130 140 Air volume flow rate in m 3 /h pl 30 Pressure drop p L in Pa Output in W/m 2 Output in W/m 2 90 80 70 60 50 40 30 20 10 0 420 400 380 360 340 320 300 280 260 240 220 200 180 160 140 120 100 80 60 40 20 0 Specific cooling output q Cooling T:85 mm - l/s [m³/h] - C q Cooling T:85 mm 28 l/s [100 m³/h] 26 C 28 l/s [100 m³/h] 18 C 3 4 5 6 7 8 9 10 11 12 13 14 15 Linear temperature difference in K Specific heating output q Heating T:85 mm - l/s [m³/h] - C q Heating T:85 mm 28 l/s [100 m³/h] 20 C 19 l/s [70 m³/h] 20 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Linear temperature difference in K www.krantz.de DS 4170 E p. 6 01.2014 6

Design specifications (cooling mode) Design specifications (cooling mode) This section deals with details of importance for the design of AVACS multifunction sails. The coordination required between the engineer and the architect for selecting the optimum solution for the ceiling, type of chilled ceiling system, kind of room ventilation, etc., is described in our publications ref. K 181 e Cooling ceiling technology and DS 4076 e Cooling ceiling system description. The design work on such chilled ceiling modules requires detailed consultation with the project s architect, the lighting consultant and the acoustical consultant. The following questions must be answered from the beginning: What cooling output is to be delivered by the chilled ceiling? What services will be integrated into the ceiling and where? Is an adaptable floor plan required or not? To what extent is the ceiling area required for sound absorption? This information is essential to determine the ceiling type and design and the possible active sail density. Besides room configuration as well as number and arrangement of ceiling services, level differences in the ceiling and mouldings also have a substantial influence on the achievable active sail density. The ceiling type and material and the dimensions of the sail elements determine the design of the heat conducting profiles and the achievable specific cooling output. A number of variable details are required, but often they can be set by the architect or drywall contractor only during project implementation. The tender text on page 10 contains all data required for selecting multifunction sails and determining the cooling output. The system layout is carried out in line with the prevailing regulations and standards (in Germany mainly DIN 1946-2), the local weather conditions as well as the actual building s conditions (e.g. mechanical ventilation or openable windows). Usual layout conditions in Germany are: operative room temperature J r = 26 C chilled water supply temperature J ws = 17 C chilled water return temperature J wr = 19 C, i.e. an output-determining temperature difference of 8 K between operative room temperature and mean chilled water temperature. Under optimum conditions, i.e. active sail density approx. 85% plus turbulent mixing ventilation from the ceiling, the cooling output can be up to 80 W/m 2 of floor area. Still higher cooling loads can be removed using high-capacity cooling elements from our SKS product family. The minimum chilled water flow rate should be no less than 45 l/h per chilled water circuit or group of elements. Otherwise an insufficient flow velocity within the copper serpentine pipework will impair the output. In view of the usual size of the sail elements (< 1 m²) the minimum water flow rate can be achieved only by connecting several sail elements in series. For further advantages, e.g. lower costs for chilled water pipework, it is usual to make groups with a pressure drop of 25 to 30 kpa. www.krantz.de DS 4170 E p. 7 01.2014 Most important are: length and width (L x B) of sail elements the ceiling system (way of fastening sail elements to ceiling suspension system) and associated details of ceiling panels the total cooling output required for the chilled ceiling per m 2 of ceiling area the ceiling layout, especially details of dimensions and location of ceiling services such as lights and air diffusers the sound-absorbing values required for the ceiling system data on texture of acoustic lining data on rear insulating material Is the chilled ceiling combined with a ventilation system? How is the supply air introduced into the room and how is the return air extracted? The following relations are to be considered for the system design: width B of ceiling panels, pipe spacing T and the resultant number of pipe rows as well as position of connection ends arrangement of water supply and return pipes making groups with as equal pressure drop as possible allowing for desired features such as pull-down design and automatic air relief cost minimization, e.g. with optimum hose lengths, position, type and number of group connections at water supply and return. provide the comprehensive system design and supply the multifunction sails with accessories flexible connection hoses modular supply and return pipes with connection possibility at the room boundary (without shutoff and control valves and fittings) to fit the ceiling layout, type and design as well as the cooling output in conjunction with the overall HVAC solution. The chilled water supply temperature must be chosen above the dew point temperature of the room air. To prevent condensation (at least in rooms with the highest expected air humidity), dew point sensors shall be fitted to the water supply pipes or to the contact profile close to the supply connection. It is essential that the dew point sensors be sufficiently flushed by air at the prevailing indoor conditions. 7

Remarks on project implementation Multifunction sails AVACS can achieve a sound absorption class to EN ISO 11654 as follows: a w = 0.60 to 0.70, Class C, i.e. highly absorptive. This mainly depends on the sail design and the sound-absorbing materials. The general influence of chilled ceilings on thermal comfort with or without mechanical ventilation is described in detail in our brochure Cooling ceiling system description (ref. DS 4076 e) and in other publications. These also contain information on the combination of our cooling ceiling systems with different air distribution systems. Such combination is advisable for most applications. Chilled ceilings make for great satisfaction of room occupants because they provide: nearly constant temperatures over the room height low room air velocities comfortable heat removal by both radiation and convection noiseless operation, etc. Remarks on project implementation A prerequisite for project implementation is a detailed system design based on the ceiling layouts approved by the architect. These include the following information: Number and arrangement of chilled sails Cooling output to be removed / Heating output to be delivered Position and type of connection ends of serpentine pipework Waterside connections between sail elements as well as specifications, e.g. type of connection hoses Position of supply and return pipes, their connection points, and the grouping of serpentine pipework Flow rates and pressure drops at the connection points of supply and return pipes to the chilled water system. To achieve different performance levels with as little sail area as possible, the multifunction sail AVACS is made available in 13 standard design options. It is thus possible to get sail lengths up to 5.5 m and cooling outputs up to 970 W (at 8 K). The sail dimensions available are shown in Fig. 5. T1 T7 T13 T2 T8 Note: Largest sail with induction unit at the head T3 T9 T4 T10 T5 T11 T6 T12 Type T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 Element length 1 500 1 2 1 3 2 2 1 750 1 1 2 1 1 3 2 2 000 1 1 1 1 1 Total length 1 500 1 750 2 000 3 000 3 250 3 500 3 750 4 000 4 500 4 750 5 000 5 250 5 500 Fig. 5: Standardized sizes for elements and sails www.krantz.de DS 4170 E p. 8 01.2014 8

Information on installation and features www.krantz.de DS 4170 E p. 9 01.2014 Information on installation The installation of the suspended multifunction sails is carried out by the drywall contractor who has to include the different sail components in his installation procedure. The installation of the water supply and return pipes is to be carried out at the same time as or directly after the installation of the ceiling suspension system, e.g. gypsum board ceiling, by the pipe fitter. The leakage test on these piping sections is to be made prior to mounting the sail elements. Fig. 6: For sail suspension, the fastening crossbars are suspended from the ceiling using threaded rods and their position is adjusted in height and alignment Then the multifunction sails are positioned against the crossbars and fixed with screws so that they cannot shift but can be unfixed. Fig. 7: Installed multifunction sails Our installation instructions describe in full detail how to properly install our multifunction sails. It is essential that these instructions be complied with. Using infrared thermography it is possible to prove that the multifunction sails installed are complete and ready for use. To prevent condensation, the operation of condensate probes and control systems along with the associated fittings will be checked following the manufacturers specifications. Main features Energy transfer by convection and radiation, resulting in high thermal comfort Standard cooling output to EN 14240: up to 165 W/m 2 (at 10 K) Only slight temperature differences in the occupied zone Suitable for refurbishment on offices and exhibition spaces Combinable with concealed air distribution systems Supply air and return air volume flow rates can range from 14 to 28 l/s [50 to 100 m 3 /h] Very high output in relation to the active sail area (area-output ratio) thanks to built-in induction unit Very high thermal comfort thanks to air distribution below the sail Induction unit not visible from below The induction unit may obviate the need for additional ventilation for the room Optimum exchange between fresh and stale air if both an induction unit and a return air diffuser are available Ventilation with conditioned supply air being discharged uniformly and horizontally Also suitable for heating Different types of finish are possible; ceiling services can be integrated Good acoustic properties Low suspension height from ceiling (min. 150 mm), thus well suited for refurbishment projects, savings on construction costs and building volume on newbuild projects The technical selection can be done by ; this ensures safety, reliability, and a comprehensive system solution With installation methods in use in building services and drywall construction ease of installation short installation time The core of the system are the copper serpentine pipework and the induction unit; this means no special requirements for chilled water quality low system costs long service life assured quality operating pressure up to 16 bars Elements manufactured to ISO 9001, using quality-controlled copper tube Available without combustible components For ceiling inspection, systems with sails in pull-down design are advantageous. We can optionally provide an inspection element to enable to get to the control valves and sensors provided by the client (for servicing purposes); then no pull-down design is required for the sail. 9

Tender text Tender text... units Multifunction sail AVACS designed to build an attractive cooling/ heating radiant ceiling system for removing sensible heat loads via radiation (approx. 40%) and convection (approx. 60%); ventilation with conditioned supply air discharged uniformly and horizontally, with high induction of indoor air. An air cushion at the discharge area minimizes dirt accumulation on the ceiling; air discharge di - rection from the facade towards the room; consisting of: a sail suspension system made up of Sendzimir galvanized crossbars that are suspended from the concrete slab by means of threaded rods (by others) and are adjustable in height; each sail element is to be stabilized without additional visible screws perforated metal ceiling panels, hole diameter: 2.5 mm, approx. 16% open area, with powder coated face; quality according to TAIM requirements; with 90 return edge (h = 50 mm) on all sides; these are additionally returned inwards and reinforced in the corners. The visible border (unperforated) on all sides is about 10 mm. black acoustic lining bonded to the rear side of the ceiling panels a cooling/heating system made up of copper serpentine pipe - work ø 12 x 0.4 mm, which is embedded in large aluminium heat conducting profiles and bonded to the ceiling panels an induction unit with oval connection spigot suitable for flex duct DN 125, for air distribution along the sail, which is to be fixed (by others) to the metal ceiling panel with 2 sheet metal screws (Note: coordination with ventilation contractor is neces - sary) As an option, sound absorbers can be put on the rear side of the metal ceiling panels to improve the sound absorption coef - ficient; further, the sail can be optionally provided in pull-down design. Technical data Total cooling output per 2-piece sail (referred to dimensions below) :... W Specific cooling output (waterside):... W/m 2 Chilled water supply temperature : 17 C Chilled water return temperature : 19 C Room temperature : 26 C Temperature difference : 8.0 K Max. operating pressure : 6 bars Water quality: adequate mains water Supply air temperature : 18 C Air volume flow rate: 28 l/s [100 m 3 /h] Dimensions / Design: Length of sail element (see standards in Fig. 5 ):... mm divided into... single lengths 1st partial length... mm 2nd partial length... mm 3rd partial length... mm Width of sail element : 1 150 mm Suspension height : 150 mm Connection type : Pipe end for push-in fitting, OD = 12 mm (standard) Connection side : one side (depending on number of pipes and number of water connections per element) Colour: similar to RAL 9010 (standard ) Make : Typ: Subject to technical alterations. AVACS Distributore in esclusiva per l Italia: F.C.R. Filtrazione Condizionamento Riscaldamento SpA Via E. Fermi, 3-20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 www.fcr.it - fcr@fcr.it www.krantz.de DS 4170 E p. 10 01.2014 10