Test Report #: Date: June 21, 2005

Similar documents
CADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG

The above item, as tested, is considered to comply with the above specifications. PAGE 1 OF 6

CONTENT. Report No.: GZ R6. Page 2 of 17

Cardiocom. CD320 Commander Flex FCC :2015 FCC Report # CCOM NVLAP Lab Code:

Models: BRP391 series; BRP392 series; BRP394 series;

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Qualification of Fastrak & First Gen Product to Railway applications Shock and Vibration Standard EN 61373

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5

FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*

Certification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A

Test Report Number: CRT-026 Project Number:

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

SVEA II GSM Connector User Manual

ANSI/TIA-568-C-2009: Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009

Programmable pressure and temperature transmitters PTM/RS485

PROGRAMMER OPERATIONS MANUAL

CMA4000 Specifications

Wireless Belt Pack BP Conductor with Radio Transmit

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Wireless Belt Pack BP Conductor Jack with Radio Transmit & Volume Control

Programmable Submersible Level Transmitters

ANSI/TIA-568-C : Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009

RPS900W Redundant Power Supply. Installation Guide.

VLT 2000 Series. How to size your VLT

Programmable pressure and temperature transmitters PTM/RS485

Wärtsilä ELAC VE 5900

ATM.ECO - Analog Pressure Transmitter

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

IEC Test Report for mini-box.com Report No. NF September 29, Test Report

Test Report Number: CRT-095 Project Number:

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

PRODUCT MANUAL. Diver Smart Interface Cable AS346

Pneumatic high-pressure controller Model CPC7000

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

Technical Information Conducal CLY421

Road and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July

Parametrable / Programmable Pressure Transmitter

Certificate of compliance

SonoMeter 30 Energy Meters

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Aquavar SOLO 2 Frequently Asked Questions

Datasheet: K-30 ASCII Sensor

GAS FUEL VALVE FORM AGV5 OM 8-03

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Guidelines to the standard IEC60601

BAPI Pressure Line of Products - FAQs

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Regulatory Compliance Mark

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Gas density monitor With integrated transmitter Model GDM-100-TI

TR Electronic Pressure Regulator. User s Manual

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Pneumatic high-pressure controller Model CPC7000

780S Ultra High Purity Series

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

C-Flow Coriolis Mass Flow Meters

Genesis MX SLM-Series

I/P Transducer Positioner Module

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

DCS Series 1 kw, 1.2 kw, & 3 kw

Efficient EMC Solutions

ATM.1ST/Ex - High Precision Transmitter

DD2 Site Preparation Checklist Hardware Site Preparation Specification

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

DPS-400 SERIES DPH-100 SERIES

Instruction Manual BA90 Precision Barometer

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

WELCOME TO THE REVOLUTION

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Features. Description

Miris Ultrasonic Processor

Certificate of conformity Power generation unit PIKO 1.5 MP, 2.0 MP, 2.5 MP, 3.0 MP, 3.6 MP, 4.2 MP

CONTROL TECHNOLOGY INC Middlebrook Pike, Knoxville, TN Phone FAX

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

The Faraday Test Centre Rochester

Procedure Troubleshooting the Interconnect Cables

Photometric Test Report

Equipment Accuracy / Selection

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Resusci Anne Simulator

AR740 RPS Redundant Power Supply Quick Install Guide

Hewlett-Packard to Agilent Technologies Transition

Additel 780 Series Pressure Controller

AN-140. Protege WX SALLIS Integration Application Note

TH-1800-T TRX-700-CNG Converter

Series AM3T-VZ 3 Watt DC-DC Converter

DETERMINATION OF SOUND POWER LEVEL OF A TRANSFORMER

CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Transcription:

CERTIFICATE #2316.01 Test Report #: 1979-2 Date: June 21, 2005 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Uninterruptable Power Supply Model Number SC1500/SC1000 Serial Number(s) QS0512146333 Test Description Radiated & Conducted Emissions Test Standard CNS 13438 Test Dates June 8-9, 2005 Test Engineer(s) Adam Chubka Test Results Pass Prepared By: Ron Leczynski Senior EMC Engineer Reviewed By: Bruce Waite EMC Group Manager This test report shall not be reproduced, except in full, without the written approval of The Compliance Management Group. Report #: 1979-2 Page 1 of 31

TABLE OF CONTENTS SECTION 1 OVERVIEW... 3 1.1 Purpose of Test... 3 1.2 Date of Test... 3 1.3 Statement of Compliance... 3 SECTION 2 REFERENCES... 3 2.1 Procedures/Standards... 3 2.2 Deviations from Standards... 3 SECTION 3 DETAILS... 3 3.1 Description of Product... 3 3.2 Test Software/Operating Mode... 3 3.3 Laboratory Test Configuration... 4 3.4 Pictures... 5 SECTION 4 CONCLUSIONS... 8 4.1 Summary of Test Results... 8 4.2 Special Notes... 8 4.3 Required Compliance Modifications... 8 SECTION 5 DATA... 9 5.3 Radiated E Field Emissions Data... 9 5.4 Conducted Emissions Data... 13 APPENDIX A EMI EMISSIONS AND IMMUNITY TEST FORM... 21 APPENDIX B PRODUCT PHOTO S... 25 APPENDIX C TA LOGO LABELING... 30 APPENDIX D COMPLIANCE MANAGEMENT GROUP CREDENTIALS... 31 Report #: 1979-2 Page 2 of 31

SECTION 1 OVERVIEW 1.1 Purpose of Test To determine if the Uninterruptable Power Supply SC1500/SC1000 will meet the CNS13438 Class A requirements for radiated and conducted emissions. 1.2 Date of Test June 8-9, 2005 1.3 Statement of Compliance The Uninterruptable Power Supply SC1500/SC1000 unit that was tested and referenced in this test report was found to comply with the requirements of: EN55022, Class A CNS 13438, Class A SECTION 2 REFERENCES 2.1 Procedures/Standards ANSI C63.4-2003, Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40 GHz CNS 13438, Taiwan Emissions Standard for Information Technology Equipment CISPR Publication 22, 1997, Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment EN55022, 1998, Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment 2.2 Deviations from Standards None. SECTION 3 DETAILS 3.1 Description of Product The Equipment Under Test (EUT) consisted of a single unit, the Uninterruptable Power Supply SC1500. The SC1000 is a depopulated SC1500 that draws less current, has fewer switching transistors and emits less EMI. The SC1500 draws more current and is the worse case emission model. Other than having less switching transistors the two models are identical. The EUT was configured as given in Appendix A. 3.2 Test Software/Operating Mode The EUT was powered on during testing with the batteries discharged to simulate the worse case emissions requirements. The output power lines were terminated and tested into a 1kVA load and 0.5kVA load. Charging and discharging modes were tested. Report #: 1979-2 Page 3 of 31

3.3 Laboratory Test Configuration The test setup was per the procedures and standards referenced in section 2.1. The voltage supplied to the EUT was 110 VAC, 60 Hz. Additionally, a conducted emissions test was run at 110 VAC, 60 Hz. All support equipment was powered by 110 VAC, 60Hz. Radiated Test The EUT was installed on the 80 cm high wooden table on the three-meter diameter turntable, which is located in the upper level of the Free Field Site (FFS). A 10-meter distance was used for EUT to antenna separation up to 1 GHz. The free field ground plane consists of a continuous ground plane 10.5 meters wide and 13.9 meters long. The product was scanned from 1-4 meters in height and 360 degrees around it. The frequency range scanned was from 30 to 1000 MHz for all configurations. All test equipment was kept below the ground plane with the exception of the antenna and associated cables required for measurements. The cable positioning, antenna height/polarization, and turntable orientation were all chosen to maximize the emissions in order to represent a worst-case condition. Conducted Test The EUT was installed on the 80 cm high wooden table in the FFS conducted emissions test area. A 40 cm distance between the vertical plane and the EUT was maintained. The EUT s power cord was bundled and kept at a distance of 80 cm from the Line Impedance Stabilization Network (LISN). Measurements were made to determine the levels of RF noise induced into the AC power line. Power for the EUT was supplied via the LISN, which was electrically bonded to the ground plane. The frequency range scanned was from 150 khz to 30 MHz. All support equipment was powered via separate LISNs. Test Equipment List Test Equipment Serial # Calibration Due Chase model CBL6111 Biconilog Antenna 30-1000 MHz 1052 4/20/2006 HP model 8566B Spectrum Analyzer (SA) 2928A06006 3/02/2006 HP model 85662A Spectrum Analyzer Display 2848A18006 3/02/2006 HP model 85685A RF Preselector (RFP) 3010A01074 3/02/2006 HP model 85650A Quasi-Peak Adapter (QPA) 2043A00171 3/02/2006 Andrew LDF2-50 radiated emissions cable RR-RE10M-02 1/22/2006 Belden 9913 conducted emissions cable RR-CE01 12/20/2005 Rohde & Schwarz 50 Ohm Line Impedance Stabilization Network (LISN), 1-Phase, 16 Amp, 50/60 Hz, model ESH3-Z5 862770/011 12/14/2005 Fluke model 111 Digital Multimeter 82700731 3/28/2006 All test equipment used is calibrated and traceable to NIST requirements. Test Environment: Temp.= 21.3 C, Relative Humidity = 45% Barometric Pressure = 99.9kPa Report #: 1979-2 Page 4 of 31

3.4 Pictures <Place picture here> Configuration for Radiated Emissions (Front Close-up) <Place picture here> Configuration for Radiated Emissions (Front) Report #: 1979-2 Page 5 of 31

3.4 Pictures <Place picture here> Configuration for Radiated Emissions (Rear Close-up) <Place picture here> Configuration for Radiated Emissions (Rear) Report #: 1979-2 Page 6 of 31

3.4 Pictures (continued) <Place picture here> Configuration for Conducted Emissions <Place picture here> Configuration for Conducted Emissions Report #: 1979-2 Page 7 of 31

SECTION 4 CONCLUSIONS 4.1 Summary of Test Results EN55022, Class A: Passed CNS 13438, Class A: Passed (Refer to CISPR 22 Radiated and Conducted Tables) 4.2 Special Notes The test results set forth in this report are expressly limited to the configuration and tests herein. Any changes in configuration may void test results. The Compliance Management Group agrees to quote charges for any retesting requested by the customer. This report must not be used by the customer to claim product endorsement by any agency of the U.S. Government. 4.3 Required Compliance Modifications None. Report #: 1979-2 Page 8 of 31

SECTION 5 DATA 5.1 Radiated E Field Emissions Data Test Date : 6/8/2005 Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Client : American Power Conversion Test Type : Qualification Temperature : 21.3 ºC Regulatory Limit : CNS 13438/CISPR 22, Class A, 10 Meters Relative Humidity : 45 % RH Barometric Pressure : 99.9 kpa Test Technician : Adam Chubka Note : Full Load, 1kVA and Charging. Equipment Used to Perform Test: Device Serial Number Calibration Due Radiated Emissions Test Version 1.0.0 N/A - Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Chase CBL6111 1052 04/20/2006 Andrew LDF2-50 RR-RE10M 02 01/22/2006 Test Data: Frequency Amplitude Corr Fact Amplitude Limit Margin Ant Pol Ant Ht Azimuth Comment MHz dbµv db dbµv/m dbµv/m db H/V cm Deg 49.40 9.5 9.54 19.0 40.00-21.00 V 150 0 Peak 62.39 13.3 6.77 20.1 40.00-19.90 V 100 0 Peak 80.00 20.1 8.30 28.4 40.00-11.60 V 220 70 Peak 128.00 12.0 12.73 24.7 40.00-15.30 V 100 150 Peak 144.00 15.6 12.69 28.3 40.00-11.70 H 400 25 Peak 311.52 14.6 15.12 29.7 47.00-17.30 H 100 0 Peak 395.10 16.0 18.54 34.5 47.00-12.50 V 100 0 Peak (Noise Floor) 753.24 15.1 25.37 40.5 47.00-6.50 H 100 0 Peak (Noise Floor) 914.38 12.8 26.69 39.5 47.00-7.50 H 100 0 Peak (Noise Floor) Scanned to 1000MHz Report #: 1979-2 Page 9 of 31

Radiated E Field Emissions Data (Cont.) Test Date : 6/8/2005 Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Client : American Power Conversion Test Type : Qualification Temperature : 21.3 ºC Regulatory Limit : CNS 13438/CISPR 22, Class A, 10 Meters Relative Humidity : 45 % RH Barometric Pressure : 99.9 kpa Test Technician : Adam Chubka Note : Half Load, 0.5kVA and Charging. No change from Full Load and Charging. Equipment Used to Perform Test: Device Serial Number Calibration Due Radiated Emissions Test Version 1.0.0 N/A - Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Chase CBL6111 1052 04/20/2006 Andrew LDF2-50 RR-RE10M 02 01/22/2006 Test Data: Frequency Amplitude Corr Fact Amplitude Limit Margin Ant Pol Ant Ht Azimuth Comment MHz dbµv db dbµv/m dbµv/m db H/V cm Deg 49.40 9.5 9.54 19.0 40.00-21.00 V 150 0 Peak 62.39 13.3 6.77 20.1 40.00-19.90 V 100 0 Peak 80.00 20.1 8.30 28.4 40.00-11.60 V 220 70 Peak 128.00 12.0 12.73 24.7 40.00-15.30 V 100 150 Peak 144.00 15.6 12.69 28.3 40.00-11.70 H 400 25 Peak 311.52 14.6 15.12 29.7 47.00-17.30 H 100 0 Peak 395.10 16.0 18.54 34.5 47.00-12.50 V 100 0 Peak (Noise Floor) 753.24 15.1 25.37 40.5 47.00-6.50 H 100 0 Peak (Noise Floor) 914.38 12.8 26.69 39.5 47.00-7.50 H 100 0 Peak (Noise Floor) Scanned to 1000MHz Report #: 1979-2 Page 10 of 31

Radiated E Field Emissions Data (Cont.) Test Date : 6/8/2005 Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Client : American Power Conversion Test Type : Qualification Temperature : 21.3 ºC Regulatory Limit : CNS 13438/CISPR 22, Class A, 10 Meters Relative Humidity : 45 % RH Barometric Pressure : 99.9 kpa Test Technician : Adam Chubka Note : Full Load, 1kVA and Discharging. Equipment Used to Perform Test: Device Serial Number Calibration Due Radiated Emissions Test Version 1.0.0 N/A - Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Chase CBL6111 1052 04/20/2006 Andrew LDF2-50 RR-RE10M 02 01/22/2006 Test Data: Frequency Amplitude Corr Fact Amplitude Limit Margin Ant Pol Ant Ht Azimuth Comment MHz dbµv db dbµv/m dbµv/m db H/V cm Deg 38.70 8.2 15.03 23.2 40.00-16.80 V 100 0 Peak 39.02 7.5 14.84 22.3 40.00-17.70 V 100 0 Peak 41.36 7.2 13.65 20.9 40.00-19.10 V 100 0 Peak 41.76 8.6 13.41 22.0 40.00-18.00 V 100 0 Peak 45.36 7.9 11.52 19.4 40.00-20.60 V 100 0 Peak 46.84 11.8 10.71 22.5 40.00-17.50 V 100 0 Peak 47.36 12.2 10.44 22.6 40.00-17.40 V 100 0 Peak 47.80 12.6 10.23 22.8 40.00-17.20 V 100 0 Peak 49.32 12.8 9.58 22.4 40.00-17.60 V 100 0 Peak 50.00 13.4 9.25 22.7 40.00-17.30 V 100 0 Peak 143.99 16.6 12.69 29.3 40.00-10.70 V 100 0 Peak 167.94 19.0 11.45 30.5 40.00-9.50 V 100 0 Peak 207.01 20.7 11.43 32.1 40.00-7.90 V 100 0 Peak Scanned to 1000MHz Report #: 1979-2 Page 11 of 31

Radiated E Field Emissions Data (Cont.) Test Date : 6/8/2005 Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Client : American Power Conversion Test Type : Qualification Temperature : 21.3 ºC Regulatory Limit : CNS 13438/CISPR 22, Class A, 10 Meters Relative Humidity : 45 % RH Barometric Pressure : 99.9 kpa Test Technician : Adam Chubka Note : Half Load, 0.5kVA and Discharging. No change from Full Load and Discharging. Equipment Used to Perform Test: Device Serial Number Calibration Due Radiated Emissions Test Version 1.0.0 N/A - Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Chase CBL6111 1052 04/20/2006 Andrew LDF2-50 RR-RE10M 02 01/22/2006 Test Data: Frequency Amplitude Corr Fact Amplitude Limit Margin Ant Pol Ant Ht Azimuth Comment MHz dbµv db dbµv/m dbµv/m db H/V cm Deg 38.70 8.2 15.03 23.2 40.00-16.80 V 100 0 Peak 39.02 7.5 14.84 22.3 40.00-17.70 V 100 0 Peak 41.36 7.2 13.65 20.9 40.00-19.10 V 100 0 Peak 41.76 8.6 13.41 22.0 40.00-18.00 V 100 0 Peak 45.36 7.9 11.52 19.4 40.00-20.60 V 100 0 Peak 46.84 11.8 10.71 22.5 40.00-17.50 V 100 0 Peak 47.36 12.2 10.44 22.6 40.00-17.40 V 100 0 Peak 47.80 12.6 10.23 22.8 40.00-17.20 V 100 0 Peak 49.32 12.8 9.58 22.4 40.00-17.60 V 100 0 Peak 50.00 13.4 9.25 22.7 40.00-17.30 V 100 0 Peak 143.99 16.6 12.69 29.3 40.00-10.70 V 100 0 Peak 167.94 19.0 11.45 30.5 40.00-9.50 V 100 0 Peak 207.01 20.7 11.43 32.1 40.00-7.90 V 100 0 Peak Scanned to 1000MHz Report #: 1979-2 Page 12 of 31

5.2 Conducted Emissions Data PHASE LINE (Full load and charging) Test Date : 6/9/2005 Scan Number : CE002 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : L1 Note : Full Load, 1kVA and Charging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.1800.09 39.60 N/A 79.00 N/A N/A 66.00 N/A Pk = -26.4 db < Av lim.2700.09 35.40 N/A 79.00 N/A N/A 66.00 N/A Pk = -30.6 db < Av lim.4800.11 34.20 N/A 79.00 N/A N/A 66.00 N/A Pk = -31.8 db < Av lim 1.0800.13 35.10 N/A 73.00 N/A N/A 60.00 N/A Pk = -24.9 db < Av lim 1.4300.16 35.90 N/A 73.00 N/A N/A 60.00 N/A Pk = -24.1 db < Av lim 5.3400.29 16.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -43.7 db < Av lim 8.9900.45 21.40 N/A 73.00 N/A N/A 60.00 N/A Pk = -38.6 db < Av lim 9.2800.46 21.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -39.0 db < Av lim 11.9700.60 23.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -36.7 db < Av lim 16.0000.83 30.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -30.0 db < Av lim 17.3700.90 30.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -29.3 db < Av lim 17.6400.91 32.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -27.3 db < Av lim 29.0700 1.35 14.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -45.2 db < Av lim Report #: 1979-2 Page 13 of 31

Conducted Emissions Data (Cont.) NEUTRAL LINE (Full load and charging) Test Date : 6/9/2005 Scan Number : CE007 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : N Note : Full Load, 1kVA and Charging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.1500.08 35.80 N/A 79.00 N/A N/A 66.00 N/A Pk = -30.2 db < Av lim.2400.08 31.50 N/A 79.00 N/A N/A 66.00 N/A Pk = -34.5 db < Av lim.3300.09 32.00 N/A 79.00 N/A N/A 66.00 N/A Pk = -34.0 db < Av lim 1.0800.11 35.50 N/A 73.00 N/A N/A 60.00 N/A Pk = -24.5 db < Av lim 1.4000.13 34.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -25.7 db < Av lim 2.5100.14 13.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -47.0 db < Av lim 3.8200.17 13.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -46.2 db < Av lim 5.1600.22 17.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -42.2 db < Av lim 6.0900.23 18.50 N/A 73.00 N/A N/A 60.00 N/A Pk = -41.5 db < Av lim 8.6000.25 17.90 N/A 73.00 N/A N/A 60.00 N/A Pk = -42.1 db < Av lim 15.6700.37 24.40 N/A 73.00 N/A N/A 60.00 N/A Pk = -35.6 db < Av lim 16.5400.37 25.60 N/A 73.00 N/A N/A 60.00 N/A Pk = -34.4 db < Av lim 17.3700.37 26.20 N/A 73.00 N/A N/A 60.00 N/A Pk = -33.8 db < Av lim 18.8400.38 22.20 N/A 73.00 N/A N/A 60.00 N/A Pk = -37.8 db < Av lim 19.8500.39 20.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -39.7 db < Av lim 29.1600.44 13.20 N/A 73.00 N/A N/A 60.00 N/A Pk = -46.8 db < Av lim Report #: 1979-2 Page 14 of 31

Conducted Emissions Data (Cont.) PHASE LINE (Half load and charging) Test Date : 6/9/2005 Scan Number : CE003 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : L1 Note : Half Load, 0.5kVA and Charging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.1500.10 34.40 N/A 79.00 N/A N/A 66.00 N/A Pk = -31.6 db < Av lim.5100.11 32.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -28.0 db < Av lim 1.1100.13 35.50 N/A 73.00 N/A N/A 60.00 N/A Pk = -24.5 db < Av lim 1.2200.14 36.10 N/A 73.00 N/A N/A 60.00 N/A Pk = -23.9 db < Av lim 5.0500.28 16.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -44.0 db < Av lim 5.9400.32 16.90 N/A 73.00 N/A N/A 60.00 N/A Pk = -43.1 db < Av lim 9.3100.46 20.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -40.0 db < Av lim 15.5500.80 29.20 N/A 73.00 N/A N/A 60.00 N/A Pk = -30.8 db < Av lim 16.8700.87 28.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -32.0 db < Av lim 17.6100.91 28.60 N/A 73.00 N/A N/A 60.00 N/A Pk = -31.4 db < Av lim 29.1000 1.36 14.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -46.0 db < Av lim Report #: 1979-2 Page 15 of 31

Conducted Emissions Data (Cont.) NEUTRAL LINE (Half load and charging) Test Date : 6/9/2005 Scan Number : CE006 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : N Note : Half Load, 0.5kVA and Charging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.1500.08 38.90 N/A 79.00 N/A N/A 66.00 N/A Pk = -27.1 db < Av lim.2100.08 34.70 N/A 79.00 N/A N/A 66.00 N/A Pk = -31.3 db < Av lim 1.1100.11 35.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -25.0 db < Av lim 1.1900.12 34.90 N/A 73.00 N/A N/A 60.00 N/A Pk = -25.1 db < Av lim 1.5500.13 30.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -29.2 db < Av lim 5.8800.23 20.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -39.3 db < Av lim 8.6900.25 19.90 N/A 73.00 N/A N/A 60.00 N/A Pk = -40.1 db < Av lim 15.1600.36 24.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -35.2 db < Av lim 16.0600.37 27.10 N/A 73.00 N/A N/A 60.00 N/A Pk = -32.9 db < Av lim 17.3700.37 27.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -32.3 db < Av lim 17.6400.36 27.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -32.2 db < Av lim 22.2400.42 18.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -41.3 db < Av lim 29.1600.44 13.60 N/A 73.00 N/A N/A 60.00 N/A Pk = -46.4 db < Av lim Report #: 1979-2 Page 16 of 31

Conducted Emissions Data (Cont.) PHASE LINE (Full load and discharging) Test Date : 6/9/2005 Scan Number : CE017 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : L1 Note : Full Load, 1kVA and Discharging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.1500.10 66.30 49.30 79.00-29.70 N/A 66.00 N/A QP = -16.7 db < Av lim.7200.11 60.50 42.10 73.00-30.90 N/A 60.00 N/A QP = -17.9 db < Av lim 1.7000.17 55.00 41.20 73.00-31.80 N/A 60.00 N/A QP = -18.8 db < Av lim 3.5200.23 54.00 45.70 73.00-27.30 N/A 60.00 N/A QP = -14.3 db < Av lim 4.2100.24 51.60 N/A 73.00 N/A N/A 60.00 N/A Pk = -8.4 db < Av lim 4.4500.25 50.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -9.3 db < Av lim 11.1000.56 43.50 N/A 73.00 N/A N/A 60.00 N/A Pk = -16.5 db < Av lim 11.4000.57 43.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -16.7 db < Av lim 17.5800.91 45.10 N/A 73.00 N/A N/A 60.00 N/A Pk = -14.9 db < Av lim 28.9300 1.35 32.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -27.2 db < Av lim Report #: 1979-2 Page 17 of 31

Conducted Emissions Data (Cont.) NEUTRAL LINE (Full load and discharging) Test Date : 6/9/2005 Scan Number : CE015 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : N Note : Full Load, 1kVA and Discharging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.2100.08 66.50 45.10 79.00-33.90 N/A 66.00 N/A QP = -20.9 db < Av lim.4500.11 64.60 42.60 79.00-36.40 N/A 66.00 N/A QP = -23.4 db < Av lim.6900.10 62.50 41.60 73.00-31.40 N/A 60.00 N/A QP = -18.4 db < Av lim.9900.11 61.80 39.60 73.00-33.40 N/A 60.00 N/A QP = -20.4 db < Av lim 1.2200.12 60.00 40.30 73.00-32.70 N/A 60.00 N/A QP = -19.7 db < Av lim 1.4300.13 58.00 37.50 73.00-35.50 N/A 60.00 N/A QP = -22.5 db < Av lim 1.7600.13 54.60 37.50 73.00-35.50 N/A 60.00 N/A QP = -22.5 db < Av lim 3.4000.16 54.90 42.60 73.00-30.40 N/A 60.00 N/A QP = -17.4 db < Av lim 3.6100.17 55.10 41.70 73.00-31.30 N/A 60.00 N/A QP = -18.3 db < Av lim 3.7600.17 54.60 41.20 73.00-31.80 N/A 60.00 N/A QP = -18.8 db < Av lim 16.2100.37 43.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -16.2 db < Av lim 17.0500.37 42.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -17.2 db < Av lim 17.9100.36 42.60 N/A 73.00 N/A N/A 60.00 N/A Pk = -17.4 db < Av lim 21.1000.42 38.00 N/A 73.00 N/A N/A 60.00 N/A Pk = -22.0 db < Av lim 22.1500.42 39.20 N/A 73.00 N/A N/A 60.00 N/A Pk = -20.8 db < Av lim 24.1800.45 39.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -20.7 db < Av lim Report #: 1979-2 Page 18 of 31

Conducted Emissions Data (Cont.) PHASE LINE (Half load and discharging) Test Date : 6/9/2005 Scan Number : CE018 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : L1 Note : Half Load, 0.5kVA and Discharging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.1500.10 61.60 44.30 79.00-34.70 N/A 66.00 N/A QP = -21.7 db < Av lim.2700.09 61.30 42.00 79.00-37.00 N/A 66.00 N/A QP = -24.0 db < Av lim 1.0200.12 55.60 35.20 73.00-37.80 N/A 60.00 N/A QP = -24.8 db < Av lim 1.9700.17 48.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -11.3 db < Av lim 3.5800.23 50.80 N/A 73.00 N/A N/A 60.00 N/A Pk = -9.2 db < Av lim 4.3600.25 49.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -10.7 db < Av lim 11.8200.59 47.60 N/A 73.00 N/A N/A 60.00 N/A Pk = -12.4 db < Av lim 17.5500.91 44.40 N/A 73.00 N/A N/A 60.00 N/A Pk = -15.6 db < Av lim Report #: 1979-2 Page 19 of 31

Conducted Emissions Data (Cont.) NEUTRAL LINE (Half load and discharging) Test Date : 6/9/2005 Scan Number : CE011 Client : APC Line Voltage : 110 Product (EUT) : SC1500 Line Frequency : 60 Test Technician : Adam Chubka Temperature : 21.2 ºC Test Type : Qualification Relative Humidity : 45 % RH Regulatory Limit : CNS 13438/CISPR 22, Class A Barometric Pressure : 99.9 kpa Device Under Test : SC1500 LISN Phase : N Note : Half Load, 0.5kVA and Discharging. Equipment Used to Perform Test: Device Serial Number Calibration Due Conducted Emissions Test Version 1.0.0 N/A - Test Software Hewlett Packard 8566B 2928A06006 03/02/2006 Hewlett Packard 85650A 2043A00171 03/02/2006 Hewlett Packard 85685A 3010A01074 03/02/2006 Rohde & Schwarz ESH3-Z5 862770/011 12/14/2005 Belden 9913 RR-CE01 12/20/2005 Test Data: Frequency Corr Fact Pk Ampl QP Ampl QP Limit QP Margin Av Ampl Av Limit Av Margin Comment MHz db dbµv dbµv dbµv db dbµv dbµv db.1500.08 61.50 44.10 79.00-34.90 N/A 66.00 N/A QP = -21.9 db < Av lim.4800.11 58.90 37.70 79.00-41.30 N/A 66.00 N/A QP = -28.3 db < Av lim.9300.11 55.80 37.50 73.00-35.50 N/A 60.00 N/A QP = -22.5 db < Av lim 1.3400.12 55.60 38.60 73.00-34.40 N/A 60.00 N/A QP = -21.4 db < Av lim 3.5800.17 53.10 39.20 73.00-33.80 N/A 60.00 N/A QP = -20.8 db < Av lim 11.1600.29 46.60 N/A 73.00 N/A N/A 60.00 N/A Pk = -13.4 db < Av lim 11.6100.29 43.90 N/A 73.00 N/A N/A 60.00 N/A Pk = -16.1 db < Av lim 15.4300.36 36.70 N/A 73.00 N/A N/A 60.00 N/A Pk = -23.3 db < Av lim 17.1000.37 42.10 N/A 73.00 N/A N/A 60.00 N/A Pk = -17.9 db < Av lim 17.4000.37 44.50 N/A 73.00 N/A N/A 60.00 N/A Pk = -15.5 db < Av lim 23.1000.43 31.50 N/A 73.00 N/A N/A 60.00 N/A Pk = -28.5 db < Av lim 28.9600.44 29.30 N/A 73.00 N/A N/A 60.00 N/A Pk = -30.7 db < Av lim Report #: 1979-2 Page 20 of 31

APPENDIX A EMI Emissions and Immunity Test Form CLIENT INFORMATION Client Name Bill Burks Product Group BNG Smart-UPS Group Telephone # (978) 670-2440 x17259 Fax # (978) 670-2380 Email address bburks@apcc.com Test to be performed PRODUCT INFORMATION Marketing Name Fox Model Number SC1500/SC1000 Code Name Serial Number QS0512146333 Part Number Test Purpose Qualify 110V Fox product with enclosure TEST SERVICES REQUESTED Test Level / Comments Emissions Radiated pre-scan Radiated (30 Mhz-1 GHz) X CISPR 22, CNS 13438, Class A Radiated (Above 1 GHz) Conducted (60 Hz) X CISPR 22, CNS 13438, Class A Conducted (50 Hz) Conducted (DC) Harmonics Flicker Telecom Immunity Radiated Immunity Cond Imm AC Lines Cond Imm Data Cables Cond Imm DC ESD EFT AC Lines EFT Data Cables Magnetic Field Voltage Dips Surge Indicate if Test is: [ ] Engineering [.X.] Qualification [ ] Audit [ ] Verification [ ] Other Report #: 1979-2 Page 21 of 31

TEST SETUP INFORMATION Voltage: 110VAC Frequency: 60 Hz [.X.] Single Phase [ ] 3-Phase Current: 12 amps max Please note any special conditions that would affect product configuration and testing. PRODUCT DESCRIPTION (Provide a detailed description of the product under test. What is its function? Describe in adequate detail that an administrator at a government agency can understand) Uninterruptible Power Supply (UPS) designed to be mounted to a din rail in a rack environment. EUT protects connected equipment up to output rating of 110V, 60Hz, 1500VA, 865W max. TEST JUSTIFICATION (Explain why this configuration represents the operating mode that should produce the highest emissions while remaining consistent with normal operating conditions.) Test units are configured to pass data as intended during normal operation. Full load charging under worst case load condition. Worst case mode is charging a fully discharged battery or while full load operation and low line. For BSMI testing scans need to be run Full load and half load, charging and discharging. The SC1000 is a depopulated SC1500. The SC1500 draws more current and is the worse case emission model. PRODUCT [internal] CONFIGURATION INFORMATION Type of Device (such as Manufacturer and capacity of Rev Part Number Serial Number disk drive, I/O, etc.) device UPS SC1500 APC OSCILLATORS & Other Generated Frequencies Oscillator/Other and Location Generated Frequency(ies) UPS microprocessor 16 MHz Battery Charger 132 KHz Inverter DC to DC 70 KHz Comm 180 KHz NOTE: The highest frequency generated determines the test level. Report #: 1979-2 Page 22 of 31

EXTERNAL CABLING INFORMATION Cable From Cable To Cable Length # of cable if Part Number multiples Description AC source EUT input 8 Input power cord EUT output Passive load 8 Output power cord EUT - DB9 connector DB9 6 Serial cable Type of Device (workstation, keyboard, etc) Passive load box SUPPORT EQUIPMENT LIST Part Number Serial Number Manufacturer EMISSIONS EXERCISE SOFTWARE DESCRIPTION (Describe what software is running on the product under test and how it will exercise the system during emissions testing). EUT operating under normal conditions (full load & charging. unit should keep supporting the load when immunity testing performed. IMMUNITY EXERCISE SOFTWARE DESCRIPTION (If different from emissions exercise software) (Include the program cycle time once, in seconds, for all devices to be exercised) EUT operating under normal conditions (full load. unit should keep supporting the load when immunity testing performed. IMMUNITY TESTING PERFORMANCE CRITERIA (Describe the proper mode of operation of the equipment under test. Explain what the test operator should monitor during the testing to determine if the product is operating within specified parameters) EUT operating under normal conditions (full load. unit should keep supporting the load when immunity testing performed. Report #: 1979-2 Page 23 of 31

FUNCTIONAL WIRING DIAGRAM OF DEVICE UNDER TEST (to be provided to EMI Lab on day of test.) SC1500 test configuration AC mains EUT DB9, Control & Ethernet Cables 110Vac, 60Hz SC1500 Passive load Box 110V, 865W The information contained in this Appendix was provided by Bill Burks of American Power Conversion It contains specific configuration details of the system as tested. Report #: 1979-2 Page 24 of 31

APPENDIX B FRONT RIGHT SIDE Report #: 1979-2 Page 25 of 31

APPENDIX B (Cont.) LEFT SIDE TOP Report #: 1979-2 Page 26 of 31

APPENDIX B (Cont.) LEFT REAR CORNER REAR I/O PORTS Report #: 1979-2 Page 27 of 31

APPENDIX B (Cont.) REAR I/O PORTS REAR AC OUTPUTS Report #: 1979-2 Page 28 of 31

APPENDIX B (Cont.) Bottom Report #: 1979-2 Page 29 of 31

APPENDIX C Report #: 1979-2 Page 30 of 31

APPENDIX D The Compliance Management Group Credentials BSMI Accreditation No. SL2-IN-E-1125R Report #: 1979-2 Page 31 of 31

TEST REPORT POLL Please rate the attached test report s quality by responding to the brief questions listed in this poll. Our goal is to provide you with high quality test reports in a timely manner. Therefore, your feedback is vital in order to determine how good our test reports are, and what areas could be improved. Please indicate beside each question what you feel is the rating. Also, feel free to make comments directly on the poll, or by attaching a separate sheet. The completed form should then be returned by either email at mryan@cmgcorp.net or FAX to Michael Ryan at 508-281-5972. Your cooperation and effort are truly appreciated. TEST REPORT NUMBER: 1979-2 1. Was the information presented clearly? 2. Was the report complete? 3. Was the report timely? 4. Did the report satisfy your requirements? YES NO YOUR NAME (optional): Optional Comments: To: Michael Ryan, Program Administrator The Compliance Management Group 202 Forest Street Marlboro, MA 01752 FAX: 508-281-5972

The Compliance Management Group Issues A CERTIFICATE OF TEST: To American Power Conversion 85 Rangeway Road North Billerica, MA 01862, USA For Product: Uninterruptable Power Supply Model: SC1500/SC1000 Date: June 21, 2005 The Compliance Management Group, a U.S. and internationally approved test laboratory, attests that compliance testing was completed satisfactorily on the aforementioned equipment as specified by the manufacturer and reported in test report number: 1979-2. The Compliance Management Group acknowledges that the Equipment Under Test was found to have passed the following standards: CNS 13438, Taiwan Emissions Standard for Information Technology Equipment, Class A EN55022, Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment, Class A Report No: 1979-2

Commodity EMC Type-Approval Test Report Product Name Applicant Manufacturer Uninterruptible Power Supply American Power Conversion American Power Conversion Manufacturer Location APC Cavite 2 Lot 10, blk 16, Phase IV, PEZA Rosario, Cavite, Philippines Description of Nameplate Main Characteristics Logo or Brand 110/120V-12A, 50-60Hz American Power Conversion Model No. X Type SC1500, SC1000 Applicable Standard for Sample Testing Test Result CNS-13438 Class A Passed Organization that issues this Type-Approval Report (Including Accreditation No. and Field) The Compliance Management Group Accreditation No. SL2-IN-E-1125R Date: June 21, 2005 Signature: