Shri Krishna Test House, B-70/1, Gali No. 8, New Modern Shahdara, Mansarover Park, Delhi. Discipline Mechanical Testing Issue Date

Similar documents
P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

CRAFTSMAN EXAMINATION, NOVEMBER 2007 GASFITTING ANSWER SCHEDULE

ISO 6804 INTERNATIONAL STANDARD. Rubber and plastics inlet hoses and hose assemblies for washing-machines and dishwashers Specification

INTERLOCKED METAL HOSE

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

An Urgent Bulletin from CSA Group

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Coiling Tube with Twist-Proof Fitting

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

BMW proposal for. Technical requirements concerning LIQUID HYDROGEN STORAGE SYSTEMS. for the use in hydrogen powered road vehicles

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

Hoses and Lances 20,000 PSI

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification

Push-In Fitting Type Pressure Gauge

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

User Information Sheet 024

Corrugated Hose Loop Calculations

2) If a pipe can fill/empty 1/n part of a tank in 1 h, then it can fill/empty the whole tank in m h.

ISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Noth American 7347 High Pressure Gas Regulators

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

E/ECE/324/Rev.1/Add.66/Rev.4/Amend.1 E/ECE/TRANS/505/Rev.1/Add.66/Rev.4/Amend.1

High Performance BSP Dial Up Pattern Pressure Reducing Valve

FRIGOFLEX is an innovative system designed for the conveyance of R134, R404, R407, R410 refrigerant gases and other specific fluids.

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

SPECIFICATION SHEET. OMEGAFLEX, Ltd. TracPipe Flexible Gas Piping Specification Sheet Specification date. ProjectName

VR46.5V(A)/VR86.5V(A) SERIES

Diaphragm pop-pop engine

General Performance Data Hose Ref Minimum Bend. Safety Pressure at 20 C (BAR) Working Pressure at. Flow Rate at 3 bar (lit/min) Working Pressure

Push-In Fitting Type Silencer

TECHNICAL ACCESSORIES

Guide for Evaluating Your Hose Assembly Supplier

PRESSURISED PAINT CONTAINER

Chapter 2 Preparations for Tank Cleaning Work

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Pressure Gauge Series

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE

USE AND ASSEMBLY INSTRUCTIONS

Air-Propane Equipment QUALITY GAS EQUIPMENT.

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Hose Manufacturing Data

PLEASE NOTE: Pressures for 200mm (8ins) and 250mm (10ins) are based on the use of METALFLEX Braided Braid

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

ULTRAMAGIC, S.A. MAINTENANCE MANUAL SUPPLEMENT NUMBER 14 INTRODUCTION OF A VAPOUR PILOT VALVE OPTION FOR THE ULTRAMAGIC MK 21 RANGE OF BURNERS

Ir HN Lam BSc(Eng), MSc(Eng), CEng, MIMechE, MCIBSE, MASHRAE, MASME, MHKIE. Test Report on Non-Return Valve for Water Closets

OPERATING MANUAL DOUBLE ACTING DRILLING INTENSIFIER HYDRAULIC TYPE

Push-In Fitting Type with Stop Valve

OWNER S TECHNICAL MANUAL

Operating manual. LINDOFLAMM Acetylene special burner LF-H series.

Tube Cutter with Measuring tape built-in

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

DIMENSIONING WATER SUPPLY SYSTEM IN BUILDING

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Expert Hydrostatic Level Transmitters

Direct Operated Precision Regulator Modular Style. Standard Specifications

Tube for General Pneumatic Piping

ASSE International Product (Seal) Listing Program

Hot Water Stationary Unit

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

CABLEGRIPS GALVANISED STAINLESS ARAMID FOR QUICK AND EFFICIENT CABLE INSTALLATION AND SUPPORT

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

1 Scope... 2 Functions of cementing float equipment... 3 Definitions... 4 Calibration... 5 Test Categories... 6 General...

Filtration FILTRATION PRODUCT TIPS

CERTIFYING GASFITTER

NEW TYPE M PRESSURE RELIEF DEVICE

Laboratory Test Results Fire Safety Conveyor Belts

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF MOBILE OFFSHORE DRILLING UNITS TITLE MOBILE OFFSHORE DRILLING UNITS SECTION 6 PIPING CHAPTERS SCOPE

EnerVal. Technical data litre storage capacity. Buffer storage vessels

DR.ING. CARLO AVANZINI PROFESSIONAL ENGINEER GRIP TEST REPORT NOVA SIRIA, ROLETTO, Premise

// ADapters GUIDelines

North American Orifice Metering System

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

ambiente Installation Guide AmbiClip Systems more than underfloor Customer: Project: Project Reference: Date:

Vertical and Horizontal Bladder Tanks

Services. Fire Sleeve. by Carol and Brian Carpenter

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Quality Plastic Pipe Fittings. Technical Data. Fabricated PVC Fittings IPS Class 100, 125, 160, 200 SCH 40 & SCH 80 Solvent Weld & Gasketed

FOAM TANK (1/2) DATA SHEET

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - APPLIANCE BALL VALVE

This document is a preview generated by EVS

ISO/TC 131/SC Hydraulic fluid power Test methods for hoses and hose assemblies

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Accessories for Sanitary Installations

Solid Roller stud mount

Draught Academy. Name. Date _

Transcription:

Last Amended on - Page 1 of 14 I. PERFORMANCE TEST 1. Domestic gas Stove for use with L.P.G. General Cl. 4, IS:5116 & Cl.4.1.1 of IS:4246 Material Cl. 5 of IS:5116 Design for Maintenance Cl. 6.2, 6.3, 6.5 & 6.6 of IS:4246 Rigidity & Stability Cl. 7 of IS:4246 Workmanship & Finish Cl. 7 of of IS:5116 & Cl. 8.2 & 8.3 of IS:4246 Gas Tap Cl. 8 of IS:5116 Injector Jets Cl. 9 of IS:5116 Burners Cl. 10 of IS:5116 & Cl. 11.2 & 11.3 of IS:4246 Burner Pan supports Cl. 12 of IS:4246 Gas Soundness Cl. 16 of IS:5116 0.2-1 kg/cm² Gas Inlet Connection Cl. 18 of IS:5116 & Cl. 14.2 of IS:4246 Strength Rigidity Cl. 15 of IS:4246

Last Amended on - Page 2 of 14 Gas Consumption Cl. 17 of IS:4246 1-2000 l/h Ignition & Flame Travel Cl. 18 of IS:4246 Flame Stability Cl. 19 of IS:4246 Noise Control Cl. 20 of IS:4246 Flash Back Cl. 21 of IS:4246 Formation of Soot Cl. 22 of IS:4246 Resistance to draught Cl. 23 of IS:4246 Combustion Cl. 24 of IS:4246 0.001-2.0 Fire Hazard & Limiting Temperature Cl. 25 of IS:4246 1-1200 C Thermal Efficiency Cl. 26 of IS:4246 0.5-100 C 2. Mini Domestic Water Heater for use with L.P.G. General requirement Cl. 4 of IS 5116 & Cl. 4.1.1 to 4.1.12 of IS :15558 Materials Cl. 5 of IS: 15558:2005 Connection Cl. 6 of IS: 15558:2005 Gas Inlet Connection Cl. 18 of IS:5116:2005

Last Amended on - Page 3 of 14 Flame Visibility Cl. 7 of IS: 15558:2005 Gas Taps Cl. 8 of IS: 15558:2005 Flame Failure Device Cl. 9 of IS: 15558 & Cl. 14 IS : 5116:2005 Ignition Device Cl. 10 of IS: 15558:2005 Protection Against accidental over Heating Cl. 11 of IS: 15558:2005 0.1-200 C Water Rate Adjuster Cl. 12 of IS: 15558:2005 Gas Soundness Cl. 16 of IS: 5116:2005 0.02-1 kg/cm² Water Soundness Cl. 15 of IS: 15558:2005 0.2-7 kg/cm² Thermal Efficiency Cl. 16 of IS: 15558:2005 1-100 % Combustion Cl. 17 of IS: 15558:2005 0.001-2.0 Gas Consumption Cl. 18 of IS: 15558:2005 1-2000 l/h Ignition & Flame Travel Cl. 19 of IS: 15558:2005 Flame Stability Cl. 20 of IS: 15558:2005 Noise Control Cl. 21 of IS: 15558:2005

Last Amended on - Page 4 of 14 Flash Back Cl. 22 of IS: 15558:2005 Resistance to Draught Cl. 23 of IS: 15558:2005 Fire Hazard & Limiting Temperature Cl. 23 of IS:5116:2005 1-1200 C Time for Temperature Rise Cl. 25 of IS: 15558:2005 1s to 120 s Hot Water Output Cl. 26 of IS: 15558, Ammendement:1 0.1-20/h 3. Domestic Pressure Cooker Capacity Test Cl. 4 of IS : 2347 1-22 litre Fusible Plugs Cl. 5.2 of IS : 2347 0.2-4 kg/cm² Pressure Regulating Device Cl. 5.5 of IS : 2347 Vent Pipe Cl. 5.7 of IS : 2347 Spring Cl. 5.8 of IS : 2347 Vent Pipe Nut Cl. 5.9 of IS : 2347 Pressure Regulating Device Cl. 6.1 of IS : 2347 Safety Pressure Relief Device Cl. 6.2 of IS : 2347 Workmanship & finish Cl.7.1&7.2 of IS 2347

Last Amended on - Page 5 of 14 Air Pressure Test Cl. 8.1 of IS : 2347 0.02-1 kg/cm² Proof Pressure Test Cl. 8.2 of IS : 2347 0.2-2 kg/cm² Operating Test for Pressure Regulating Device Test for Safety Pressure Relief Device Cl. 8.3 of IS : 2347 Cl. 8.4 of IS : 2347 0.05-2 kg/cm² 0.02-3 kg/cm² Bursting Pressure Test Cl. 8.5 of IS : 2347 0.2-6 kg/cm² Test for Removal of Lid Under Pressure Cl. 8.6 of IS : 2347 0.02-1 kg/cm² 4. Flexible Rubber Tube for L.P.G. General Cl. 4.1 of IS:10908 Workmanship & Finish Cl. 4.2 of IS:10908 Dimension ( Diameter) Cl.4.3.1 of IS:10908 0.02-200 mm Dimension ( Wall Thickness ) Cl.4.3.2 of IS:10908 0.02-200 mm Grip Strength Test Cl.4.4 of IS:10908 Pressure Test Cl.4.5 of IS:10908 0.02-1 & 0.1-7 kg/cm² Shore Hardness Test Cl.4.6 of IS:10908 1-100 A

Last Amended on - Page 6 of 14 Accelerated Ageing Test Cl.4.7 of IS:10908 1-200 C Flexibility Test Cl.4.8 of IS:10908 Crushing Test Cl.4.9 of IS:10908 Resistance to L.P.G. Test Cl.4.10 of IS:10908 Resistance to Ozone Test Cl.4.11 of IS:10908 Burning Behaviour Test Cl.4.12 of IS:10908 5. Rubber Hose for L.P.G. Material a. Lining b. Reinforcement c. Cover Cl.5.2 of IS : 9573 : 1928 Dimension & Tolerances a. Bore Size b. Thickness of Lining Cover c. Length 4.2.1.2 of IS 443 4.2.2 of IS 443 4.2.2 of IS 443 0-50 mm 0.02-200 mm Physical Requirements a. Tensile Strength & Elongation at break of lining & cover of the Hose. b. Accelerated Ageing Test c. Resistance of Lining to n-pentane. Cl.5of IS : 443 Cl. 6 of IS 443 Cl 5.4.3 of IS 9573 96-3000% 1-200 C

Last Amended on - Page 7 of 14 Performance Requirements a. Adhesion b. Low temp. Flexibility. c. Flexibility of Hose. d. Ozone Resistance e. Proof Pressure Test f. Burning pressure. g. Electrical Continuity Test. h. Grip Strength Test. i. Burning Behavior. Cl.6 of IS : 3400(Pt-24) Cl.5.5.2 of IS 9573 Cl.5.5.3 of IS 9573 Cl.5.5.4 of IS 9573 Cl.5.5.5 of IS 9573 & Cl. 8.3 of IS 443 Cl. 8.2 of IS 443 Cl.5.5.6 of IS 9573 Cl.5.5.7 of IS 9573 Cl.5.5.8.2 of IS 9573 30-40 6. General purpose Rubber Water Hose Construction a. Lining b. Reinforcement c. Cover Cl.4.1 of IS : 444 Dimension & Tolerances a. Bore Size b. Lining & Cover Thickness c. Length Cl.4.2.1.2 of IS443 Cl.4.2.2 of IS 443 Cl.4.2.3 of IS 444 0-50 mm 0.02-200mm Requirements a. Tensile Strength & Elongation at break of lining & cover b. Accelerated Ageing Test c. Swelling Test Cl. 5 of IS : 443 Cl. 6 of IS : 443 IS 3400 (Pt-6) 96-3000%

Last Amended on - Page 8 of 14 Performance Requirements a. Adhesion b. Pressure Requirements Method A of IS 3400(P-5) Cl.8 of IS : 443 2-100kg/cm² 7. Rubber Hose for Welding Construction a. Lining b. Reinforcement c. Cover Cl.3.1 of IS : 447-1988 Dimension & Tolerances a. Bore Size b. Lining & Cover Thickness c. Length Cl.4.2.1.2 of IS443 Cl.4.2.2 of IS 443 Cl.4.2.3 of IS 443 0-50 mm 0.02-200mm Physical Requirements a. Tensile Strength & Elongation at break of lining & cover of the Hose. b. Accelerated Ageing Test Cl. 5 of IS : 443 Cl. 6 of IS : 443 96-3000% Performance Requirements a. Hydraulic Test b. Busting Test c. Increase Diameter at working pressure d. Change in Length e. Adhesion between components Cl. 8.3 of IS : 443 Cl. 8.2 of IS : 443 Cl. 8.5 of IS : 443 Cl. 8.4 of IS : 443 IS 3400(P-5) 2-100 kg/cm² 2-100 kg/cm² 0.02-200mm 0.02-200mm

Last Amended on - Page 9 of 14 8. Rubber Air Hose Construction a. Lining b. Reinforcement c. Cover Dimension & Tolerances a. Bore Size b. Lining & Cover Thickness c. Length Physical Requirements a. Tensile Strength & Elongation at break of lining & cover of the Hose. b. Accelerated Ageing Test c. Oil Absorption Test Performance Requirements a. Adhesion b. Pressure Requirements Cl.4.1of IS : 446 Cl.4.2.1.2 of IS443 Cl.4.2.2 of IS 443 Cl.4.2.3 of IS 443 Cl. 5 of IS : 443 Cl. 6 of IS : 443 Cl. 4.3.3 of IS 446 Cl.7 of IS : 3400(P-5) Cl. 8 of IS : 443 0.50 mm 0.02-200mm 96-3000% 1-200 0 C 2-100 kg/cm² 9. Rubber Hose for Fuel Dispensing Construction a. Lining b. Reinforcement c. Cover Cl. 3.1of IS : 2396 Dimension & Tolerances a. Bore Size b. Lining & Cover Thickness c. Length Cl.4.2.1.1& Cl.4.2.1.2 of IS443 Cl.4.2.2 of IS 443 Cl.3.2.3 of IS 2396 0-50 mm 0.02-200mm

Last Amended on - Page 10 of 14 Physical Requirements a. Tensile Strength & Elongation at break of lining & cover of the Hose. b. Accelerated Ageing Test c. Volume Change d. Fuel soluble matter of lining Cl. 5 of IS : 443 Cl. 6 of IS : 443 Cl. 9 of IS 443 App. A of IS 2396 96-3000% 1-200 0 C Performance Requirements a. Hydraulic Proof Test Cl. 8.3 of IS : 443 2-100 kg/cm² b. Increase Diameter at proof pressure c. Twist at proof pressure Cl. 8.5 of IS : 443 App. B of IS 2396 1-50 kg/cm² 0-50 mm d. Busting Test Cl. 8.3 of IS : 443 2-100 kg/cm² e. Adhesion between components IS 3400(P-5) f. Electrical Continuity Table-3 of IS 2396 10. Rubber Gasket for Pressure Cooker Material Test Cl.3.1 of IS : 7466 Workmanship & Finish Cl.3.2 of IS : 7466 Dimensions Cl. 3.3 of IS : 7466

Last Amended on - Page 11 of 14 Requirements a. Hardness Test b. Tensile Strength Test c. Elongation Test d. After Ageing for 3 days Hardness, Tensile Strength & Elongation at break test e. After Ageing for 8 hrs.- Hardness, Tensile Strength, Elongation & Volume Test. f. Compression Set Test Cl. 3.4 IS:3400(Part-2) IS:3400(Part-1) IS:3400(Part-1) IS:3400(Part-4) IS:3400(Part-4) IS:3400(Part-10) 30-1001 RHD 96-3000% 1-200 C 1-200 C 11. Performance of Handles & Handle Assemblies Attached to Cookware Construction Cl. 4.1 of IS: 13395 Materials Cl. 4.2 of IS: 13395 Selection & Size Cl. 4.3 IS: 13395 1 300 mm Position with respect to cookware Cl. 4.4 IS: 13395 1 300 mm Attachment to cookware Cl. 4.5 of IS: 13395 0.5-50 Nm, 1-100 C Bending Strength Cl. 5.2 of IS: 13395 1-500 N Torque Strength Cl. 5.3 of IS: 13395 0.5-50 Nm Impact Strength Cl. 5.4 of IS: 13395 Fatigue Resistance Cl. 5.5 of IS: 13395 1-9999R

Last Amended on - Page 12 of 14 Leakage Cl. 5.6of IS: 13395 1-300 C 1s-30 min. Thermal Insulation Cl. 5.7of IS: 13395 1-300 C 1 s-30 min. Washing Resistance Cl. 5.9of IS: 13395 1-300 C 1 s-30 min. Heat Resistance Cl. 5.8 of IS: 13395 1-200 C, 1 s-30 min Burning Resistance Cl. 5.10 IS: 13395 12. SS Sink for Domestic Purpose Thickness of Sheet / Strip Cl. 6.1 of IS: 13983 1-10 mm Depth of bowls Cl. 6.2 of IS: 13983 1-1000 mm Internal Dia. Of Bowls Cl. 6.3 of IS: 13983 1-1000 mm Bowl Locating limits Cl. 6.4 of IS: 13983 0.02-200mm Coordinating size Cl. 6.5 of IS: 13983 1-1000 mm Waste outlet Cl. 7.4 of IS: 13983 1-1000 mm Tap holes Cl. 7.5 of IS: 13983 1-1000 mm 0.02-200mm

Last Amended on - Page 13 of 14 Over flows Cl. 7.6 of IS: 13983 0.02-200mm Construction & Workmanship Cl. 7.2.1 of IS: 13983 1-50000x100 lux 13. Plastic Flushing Cistern for Water Closets and Urinals Cistern Cl. 5.1 of IS : 7231 0.01-25 mm Cover Cl. 5.2 of IS : 7231 Flush Pipe Cl. 5.3 of IS : 7231 0.02-200mm Inlet & over flow holes Cl. 5.4 of IS : 7231 0.02-200mm Operating Mechanism Cl. 5.6 of IS : 7231 1-600 mm String (Chain) Cl. 5.7 of IS : 7231 1g-50 kg Over flow pipe Cl. 5.8 of IS : 7231 0.02-200mm Finish Cl. 6 of IS : 7231 Flushing Arrangement Cl. 7.1 of IS : 7231 Working water level Cl. 7.2 of IS : 7231 Freedom from self siphonage Cl. 7.3 of IS : 7231 Reduced water level Cl. 7.5 of IS : 7231 Discharge capacity Cl. 7.6 of IS : 7231 1-1000 ml

Last Amended on - Page 14 of 14 Discharge rate Cl. 7.7 of IS : 7231 1-1000 ml Distortion resistance test Cl. 8.1 of IS : 7231 0.02-200 mm Dead Load Test & Front Thrust Test Cl. 8.2 & 8.3 of IS : 7231 23 kg & 1 kg 1s-30 min. Impact Test Cl. 8.4 of IS : 7231 1-1000 mm Endurance Test Cl. 9.3 of IS : 7231 1-99999 Count -X-X-X-X-X-X-X-X-X-X-X-X-X-X-