An Experimental Performance Study of Vortex Tube Refrigeration System

Similar documents
Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

Effect of Hot End Obstruction and Nozzle on the Performance of Vortex Tube

EXPERIMENTAL PERFORMANCE ANALYSIS OF VORTEX TUBE FOR VARIOUS PARAMETERS

Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube

An Efficient Vortex Tube With Max C.O.P

Modeling and Investigation of Change in Working Parameters on the Performance of the Vortex Tube with CFD Analysis

FABRICATION AND OPTIMIZATION OF PERFORMANCE OF VORTEX TUBE PARAMETERS

Development of Two Opposing Nozzle Vortex Tube Using Air as Working Fluid

Fabrication and Experimental Analysis of a Vortex Tube Refrigeration system

DEVELOPMENT OF TWO OPPOSING NOZZLE VORTEX TUBE USING AIR AS WORKING FLUID

Experimental Investigation and Modification of Ranque Hilsch Vortex Tube

Effect of Cold Fraction and Orifice Diameter on the Performance of Modified Vortex Tube with Dual Forced Vortex Flow

An Experimental Investigation of the Optimum Geometry for Energy Separation of the Ranque- Hilsch Vortex Tube

Applied Fluid Mechanics

Hermetic Compressor With Improved Motor Cooling

Modification and experimental research on vortex tube

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF HELICAL NOZZLES EFFECTS ON THE ENERGY SEPARATION IN A VORTEX TUBE

Vortex Tube Short Course February 2017

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

EXPERIMENTAL STUDY OF THE ENERGY SEPARATION IN COUNTER FLOW VORTEX TUBE

Chapter 3 EXPERIMENTAL: EQUIPMENT, SET-UP, AND PROCEDURE

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

THE EFFECT OF L/D RATIO ON THE TEMPERATURE SEPARATION IN THE COUNTERFLOW VORTEX TUBE

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

An Impeller Blade Analysis of Centrifugal Gas Compressor Using CFD

Enter your parameter set number (1-27)

Research and optimization of intake restrictor for Formula SAE car engine

ASSIGNMENT 2 CHE 3473

To Study the Effects of Design Parameters on Vortex Tube with CFD Analysis

ASSIGNMENT 2 CHE 3473

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

PERFORMANCE STUDY OF A MODIFIED RANQUE-HILSCH VORTEX TUBE

An Investigation of Liquid Injection in Refrigeration Screw Compressors

(Refer Slide Time: 2:16)

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

Figure 1 Schematic of opposing air bearing concept

VORTEX TUBE COOLING SYSTEM

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Design Review Agenda

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Numerical Fluid Analysis of a Variable Geometry Compressor for Use in a Turbocharger

RESIDENTIAL WATER DISTRIBUTION

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

A Research on the Airflow Efficiency Analysis according to the Variation of the Geometry Tolerance of the Sirocco Fan Cut-off for Air Purifier

A review on design criteria for vortex tubes

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

TESTING AND ANALYZING ON P-V DIAGRAM OF CO 2 ROLLING PISTON EXPANDER

SIMULTANEOUS OPTIMIZATION OF HOT AND COLD OUTLET AIR TEMPERATURES OF VORTEX TUBE USING GREY RELATIONAL ANALYSIS AND TAGUCHI METHOD

ME 200 Thermodynamics I Spring 2010 (Last) (First) Thermo Number: CIRCLE YOUR LECTURE BELOW

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

Inlet Swirl on Turbocharger Compressor Performance

Multifunctional Screw Compressor Rotors

Wind tunnel effects on wingtip vortices

Investigation of failure in performance of linear compressor & its rectifications

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

Injector Dynamics Assumptions and their Impact on Predicting Cavitation and Performance

Fundamentals of Turboexpanders Basic Theory and Design

Application of Computational Fluid Dynamics to Compressor Efficiency Improvement

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

Experimental Investigation of Vortex Tube Refrigeration

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

Free Surface Flow Simulation with ACUSIM in the Water Industry

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

CFD Simulation of the Flow Through Reciprocating Compressor Self-Acting Valves

Third measurement MEASUREMENT OF PRESSURE

International Journal of Advance Engineering and Research Development DESIGN CALCULATIONS TO EVALUATE PERFORMANCE PARAMETERS OF COMPRESSOR VALVE

ENGG. THERMODYNAMICS

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

Compressors. Basic Classification and design overview

Development of Gasdynamic Probe for Total Temperature Measurement in gases

Purdue e-pubs. Purdue University. Stephan Lehr Technische Universitaet Dresden. Follow this and additional works at:

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

EFFECTS OF WATER SPRAYS AND SCRUBBER EXHAUST ON FACE METHANE CONCENTRATIONS

MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR

THE WAY THE VENTURI AND ORIFICES WORK

SIMULATION OF ENVIRONMENTAL FLIGHT CONDITIONS

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

STUDIES ON THE OPTIMUM PERFORMANCE OF TAPERED VORTEX FLAPS

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

Heat Transfer Research on a Special Cryogenic Heat Exchanger-a Neutron Moderator Cell (NMC)

Linear Compressor Discharge Manifold Design For High Thermal Efficiency

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Analysis of pressure losses in the diffuser of a control valve

Transcription:

An Experimental Performance Study of Vortex Tube Refrigeration System Sankar Ram T. Department Of Industrial Refrigeration and Cryogenics T. K. M. College of Engineering Karicode, Kollam, Kerala sankarram9@gmail.com Abstract The phenomenon of temperature distribution in confined steady rotating gas flows is called Ranque-Hilsch effect. The simple counter-flow vortex tube consists of a long hollow cylinder with tangential nozzle at one end for injecting compressed air. The flow inside the vortex tube can be described as rotating air, which moves in a spring-shaped vortex track. The peripheral flow moves toward the hot end where a hot end plug is placed and the axial flow, which is forced back by the plug, moves in the opposite direction towards the cold end. Keywords-Vortex tube; Refrigeration; cooling; I. NOTATION A C, A H : Areas of the cold orifice and at the hot end, respectively, mm2 A N, A T : Areas of the nozzle and the tube, respectively, mm2 D C, D N, D T : s of the cold orifice, the nozzle and the tube, respectively, mm L : Length of the tube, mm m C, m H : Mass flow rates of cold and hot air, respectively, kg/s mi : Mass flow rate of air at inlet nozzle, kg/s Ta : Ambient temperature, oc T C, T H : Temperature of air at cold and hot ends, respectively, oc T o : Temperature of air inside the compressor tank, oc v C, v H : Velocity of the air at cold orifice and at hot end, respectively, m/s dt C : Temperature drop in vortex tube, oc dia : temp : Temperature RHVT : Ranque-Hilsch Vortex Tube cold end: The end of RHVT were cold air is produced hot end : The end of RHVT were cold air is produced SI units are used as far as possible and can be assumed wherever necessary if not otherwise mentioned. II. INTRODUCTION The vortex tube also known as Hilsch or Ranque tube 1,2 is a simple device having no moving parts, which produces hot and cold air streams simultaneously at its two ends from a source of compressed air. It consists of a long tube having a tangential nozzle near one end and a conical valve at the other end, as shown schematically in Figure 1. Anish Raj K. Department Of Mechanical Engineering Jyothi Engineering College Cheruthuruthy, Thrissur, Kerala anishrajk16@gmail.com A diaphragm called cold orifice, with a suitable sized hole in its centre is placed immediately to the left of the tangential inlet nozzle. The compressed air is then introduced into the tube through this nozzle. The tangential flow imparts a whirling or vortex motion to the inlet air, which subsequently spirals down the tube to the right of the inlet nozzle. Conical valve at right end of the tube confines the exiting air to regions near the outer wall and restricts it to the central portion of the tube from making a direct exit. The central part of the air flows in reverse direction and makes exit from the left end of the tube with sizeable temperature drop, thus creating a cold stream. The outer part of the air near the wall of the tube escapes through the right end of the tube and is found to have temperature higher than that of inlet air. Fig. 1 Schematic diagram of a vortex tube Literature review reveals that there is no theory so perfect, which gives the satisfactory explanation of the vortex tube phenomenon as explained by various researchers 6,9,1,11. Therefore, it was decided to carryout experimental investigations for understanding the heat transfer characteristics in a vortex tube. An attempt has been made to study the effect of various parameters like mass flow rates of cold and hot air, nozzle area of inlet compressed air, cold orifice area and hot end area of the tube. The study also investigates the effect of L/D ratio on the performance of the vortex tube. III. DESIGN PROCEDURE In general, there are two design features associated with a vortex tube, namely, (a) maximum temperature drop vortex tube design for producing small quantity of air with very low temperatures and (b) maximum cooling effect vortex tube design for producing large quantity of air with moderate temperatures 3. Of these two design considerations 'maximum temperature drop design' has been used in the present study. The parameters investigated in the study, to understand their inter-relationships and their effect on the performance of the vortex tube are: IJEDR134 17

nozzle diameter; cold orifice diameter; mass flow rates of cold and hot air; area at the hot end. The line diagram of the experimental setup is shown in Figure 2. The temperature of air at cold and hot ends was measured with digital thermometers with an accuracy of ± 1 o C. The air velocities were measured by an anemometer. The pressures were measured by pressure gauges. All the instruments were calibrated before the measurements were actually observed/recorded. Fig. 2 Basic Design Outline Selected for construction In the present investigation, a nozzle area to tube area ratio of.11 for maximum temperature drop has been considered, as suggested by Soni and Thomson 7. Further, they suggested that the ratio of cold orifice area to tube area should be.8 for achieving maximum temperature drop. The same researchers also mentioned that the length of the vortex tube should be 45-55 times the tube diameter. Keeping these suggestions in view, a vortex tube of size 18 mm inner diameter of CPVC was selected. The vortex tube was a 81 mm long pipe. Four straight nozzles were made and each had 2 mm diameter and was 2.5 mm long, long. Similarly, two cold orifices were used having hole diameters of 4.5 mm and 5.8 mm, respectively. A conical valve made of wood was provided on the right hand side of the tube to regulate the flow with diameters varying from 7 to mm. Materials were selected based on easy availability, ease of working, and insulating capability which is necessary for achieving the adiabatic conditions assumed. CPVC pipings are widely used in industries to carry hot fluid. The pipes used were rated for a maximum temperature of 8 o C. Table 1 Design Parameters of equipment constructed Tube Inner 18mm (d) Cold Plate Orifice 9mm (.5d) Inlet Nozzle 2 mm (.1d) No. of Inlet (depending on flow rate 4 Nozzle of air) Length: Hot End 81mm (45d-55d) Length: Cold End -3 mm (experimental value) Pressure Range 1 bar -6 bar (experimental value) IV. EXPERIMENTAL SETUP To study the effect of various parameters such as mass flow rates of cold and hot air, cold orifice area and hot end area on the performance of the vortex tube, an experimental set up was prepared as per design described earlier. The vortex tube components were made in a manner such that certain geometries of the tube could be changed from a maximum value to a minimum value. Fig. 3 Line Diagram of Experimental Setup V. TEST PROCEDURE The various parameters, which affect the performance of the vortex tube, were divided into following input and output variables: Input variables: Area of cold orifice, Effective Area Of Hot End, Inlet Pressure, Inlet Mass Flow Rate Output variables: Temperature of cold air, cold fraction, and Temperature of hot air. The compressor was initially run for about 3 min to get a stable compressor air tank pressure. Firstly the cold end orifice was set to a value. For that value a pressure is set and the hot end valve is varied to get the output variables. The Pressure was varied to obtain various output variables. The procedure was repeated for various cold end orifice diameters. The values of density of air at both ends were calculated assuming the flow to be adiabatic. The following assumptions were made for the ease calculation: The entire system is insulated and the processes are adiabatic. The outlet pressures are equal to atmospheric pressures 5. The cold end diaphragm and hot end conical valve does not absorb any heat. There is no change in performance due to the projecting part of conical valve. There is no effect of back pressure in the outlets. VI. RESULTS The study was conducted with a simple, inhouse fabricated vortex tube with the aim for obtaining correct thermodynamic IJEDR134 18

Hot Temperature oc Temperature oc Temp Diff oc results. The equipment designed was not for the best results ie. least temperatures, but for more accurate results. The main problem observed was the heating up of the tubes due to friction during continuous use. To overcome this, the air flow was stopped in intervals and the equipment was allowed to cool down. Nevertheless the equipment worked as desired and the readings were obtained. A. Effect Of Hot Plug The effect of hot plug diameter was studied varying the effective plug diameter by moving the conical valve in and out of the tube. Figure 4 shows the effect of hot plug diameter on the output temperatures. The coldest temperatures were obtained at about diameter of hot plug for a pipe of 18 mm internal diameter. Going higher than that value increases the temperature of cold air due to mixing of more hot air to the cold passage because of high pressure build up inside the pipe. Decreasing the plug diameter also increases the temperature due to reduce mass fraction of cold air. Reducing the diameter below a limit, it was observed that there is a negative pressure buildup near the nozzles leading to air suction at cold end rather than air rejection. As the hot plug diameter increases, there was a small but steady rise in temperature at hot end. At very high plug diameters, above 17mm for an 18 mm pipe, there was a sudden increase of pressure leading to very high temperatures. 8 6 6 5 4 3 1 15.5 16 16.5 17 17.5 18 Fig. 5 Temperature Difference At Outlet vs Hot Plug B. Effect Of Mass Flow Rate Hot Plug mm During the experiment, it was observed that the mass flow rate of air is the main characteristic feature that controls the temperature of cold air produced. Due to sudden expansion of air near outlet of nozzles, there is a low pressure region created just near the diaphragm placed. If the mass flow rate cannot supply enough amount of air there will be a negative pressure leading to suction of air through the cold outlet. The mass flow rate is denoted for sake of simplicity in terms of number of turns of the ball valve used to control the mass flow rate. On a scale of 1 to 5 turns, the mass flow rate varies between 5.5 to 3 m 3 /s. 3 4 5 4 15.5 16 16.5 17 17.5 18 Hot plug mm Fig. 4 Temperature vs Hot plug Cold Hot Figure 6 shows the effect of mass flow rate on hot outlet temperature. It can be seen that in all cases, as mass flow rate increases there is increase in temperature. At low hot plug opening, this rise is quite insignificant. But as the diameter of hot plug increases, the rise in temperature is quite dominant. Due to restrictions on material, the test for highest temperature was held at 8 O C. It is also observed that at diameters less than, There is no much effect by either hot plug diameter or mass flow rate. Figure 5 shows the effect of hot plug diameters on the total temperature difference that can be obtained for different number of turns of the valve, which is an indication of total mass flow rate. At very low hot plug diameters, there was no much appreciable temperature difference between the hot and cold outlet. As the diameter was increased there was a steady increase in temperature difference, which is a partial indication of efficiency of the unit. 8 7 6 5 4 3 1 2 4 6 Fig. 6 Hot End Temperature vs Mass Flow Rate Figure 7 shows the effect of mass flow rate on cold outlet temperature. It can be seen that in all cases, as mass flow rate increases there is steady decrease in temperature at cold end. IJEDR134 19

Temp Diff oc Cold Temperture oc Unlike the hot end temperature, the effect of mass flow rate is quite predominant in case of cold end temperatures. For increase in mass flow rate, there is continuous decrease of temperature, with no signs of a point of inflection. With high mass flow rates sub zero temperatures can be easily obtained in a vortex tube. It is of quite importance that least temperatures are observed in hot plug diameter of, going above or below these increases the cold end temperature. 3 25 15 1 5 2 4 6 Fig. 7 Cold End temperature vs Mass Flow Rate Figure 8 shows the effect of mass flow rate on temperaure diffrence that can be obtained on the vortex tube. It can be observed that a steady rise in temperaure diffrence is obtained sa mass flow rate is increased but as the hot plug diameter is reduced the rate of temperaure rise deceases. It is to be noted that at very low mass flow rates, the operation of vortex tube is hinged due to effect of back pressure at the cold exit. 2. Cold end temperature as well as adiabatic efficiency is more influenced by the mass flow rate and the size of the cold orifice rather than the size of the hot plug. 3. Higher temperature drops are obtained in vortex tube at 9% hot plug diameter and is due to higher hot temperatures rather that low cold temperatures. 4. The pressure and mass flow rate is to be kept at a range for proper operation of tube. The higher range is defined by the strength of tube while lower limit is defined by the tube diameter and hot plug diameter. 5. It is observed that maximum cooling effect is obtained at of hot plug diameter, 9% of Tube inner diameter. CFD analysis shows an 86 % diameter gives maximum cooling effect 9. 6. The material of tube has significant importance in design of vortex tube. The internal roughness increases friction, causing heating up of pipe and loss of tangential velocity of flow. 7. A 1-5 O inclination of the inlet orifice towards hot end helped in reducing pressure buildup near the orifices, restricting further flow. A higher inclination increased the axial velocity, reducing the efficiency of operation. ACKNOWLEDGMENT The authors express their gratitude to staffs of Department of Mechanical Engineering and Department Of Applied Electronics, Jyothi Engineering College for providing necessary facilities and encouragement for the completion of this work. The authors also express their sincere thanks to the staff at production shop, and thermal laboratory for their continuous help in experimentation and preparation of this work. 6 5 4 3 1 2 4 6 Fig. 8 Temperature Difference vs Mass Flow Rate VII. CONCLUSIONS 1. The design of nozzle affects the conversion of pressure to velocity. It doesn't have much contribution in the energy separation process. The area of nozzle is a constant for given tube size and number of nozzles depends on mass flow rate possible. REFERENCES [1] G J Ranque. Experiments on Expansion in a Vortex with Simultaneous Exhaust of Hot and Cold Air. Le Journal De Physique(Journal Of Physis), et le Radium (Paris), vol 4, June 1933, pp 1125-113. [2] R Hilsch. The use of the Expansion of Aires in a Centrifugal Field as a Cooling Process. Review of Scientific Instruments, vol 13, February 1947, pp 18-113. [3] U. Behera, P.J. Paul, S.Kasthurirengan, R. Karunanithi,S.N. Ram, K. Dinesh, S. Jacob,5, CFD analysis and experimental investigations towards optimizing the parameters of Ranque Hilsch vortex tube, International Journal of Heat and Mass Transfer 48, 1961 1973 [4] Sachin U. Nimbalkar Michael R. Muller, An experimental investigation of the optimum geometry for the cold end orifice of a vortex tube, Applied thermal Engineering vol.29, 8, p 59-51. [5] Bramo, A. R., et al.: Computational Fluid Dynamics Simulation Of Length To Ratio Effects On The Energy Separation In A Vortex Tube; Thermal Science, Year 11, Vol. 15, No. 3, pp. 833-848 [6] R B Aronson. The Vortex Tube: Cooling with Compressed Air. Journal of Machine Design, December 1976, pp 14-143. [7] Y Soni and W J Thomson. Optimal Design of Ranque Hilsch Vortex Tube. ASME Journal of Heat Transfer, vol 94, no 2, May 1975, pp 316-317. [8] R L Collins and R B Lovelace. Experimental Study of Two Phase Propane Expanded through the Ranque Hilsch Tube. ASME Journal of Heat Transfer, vol 11, no 2, May 1979, pp 3-35. IJEDR134

[9] H Takahama and H Yokosawa. Energy Separation in Vortex with a Divergent Chamber. Transactions of ASME, vol 13, May 1981, pp 196-3. [1] M Kurosaka. Acoustic Streaming in Swirling Flow and the Ranque Hilsch Effect. Journal of Fluid Mechanics, 1982, p 139. [11] Y D Raiskii and L E Tankel. Influence of Vortex Tube Configuration and Length on the Process of Energetic Air Separation. Journal of Engineering Physics, vol 27, no 6, December 1974, pp 1578-1581. [12] V I Metenin. Investigations of Vortex Tube Type Compressed Air Separators. Soviet Physics Technical Physics, vol 5, 1961, pp 125-132. IJEDR134 21