International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Similar documents
International Journal of Research and Development in Pharmacy and Life Sciences. Research Article

IJPAR Vol.6 Issue 1 Jan - Mar Journal Home page:

A NOVEL RP-HPLC METHOD FOR THE QUANTIFICATION OF ICATIBANT IN FORMULATIONS

FRANZ CELL TEST OF NANO GLUTATHIONE WITH HPLC ANALYSIS

CHAPTER 3 Development and Validation of a RP-HPLC method for Dutasteride and its impurities in bulk drug

International Journal of Generic Drugs ANALYTICAL METHOD PROCEDURES THIS SOP IS 'SWITCHED : OFF : ON'

A VALIDATED STABILITY-INDICATING RP-HPLC ASSAY METHOD FOR BOLDENONE UNDECYLENATE AND ITS RELATED SUBSTANCES

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

Chemical Analysis for Methyltestosterone

(2 pts) Draw the line of best fit through the data and estimate the concentration of Fe in your sample solution.

Int. Res J Pharm. App Sci., 2012; 2(6): ISSN:

Trace-Level Analysis of Metanephrines in Plasma by HILIC LC-MS/MS

SIMPLE, EFFICIENT AND SIMULTANEOUS DETERMINATION OF ANABOLIC STEROIDS IN HUMAN URINE

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

SOP: Derivatized testosterone_01 Revision: 01 Date Effective: 05/17/15

Dissolution test results showing biorelevant media made from SIF Powder Original is the same as media prepared using methylene chloride

Fast method for Ginseng Analyses using Agilent Poroshell 120 Columns Scaled from a Traditional Method

Extended Application Note

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

CORESTA RECOMMENDED METHOD Nº 67

Research Article A Validated Method Development of Dutasteride in Human Plasma Using LC-MS/MS

Evaluation of linear and step gradient performance and retention time precision of the Agilent 1200 Series Rapid Resolution LC

GUIDE TO ULTRA-FAST HPLC. Quick Tips for Converting Conventional Reversed-Phase HPLC Separations to Ultra-Fast Separations

ASTM WK Standard Test Method for Dissolved Gases. Anne Jurek Applications Chemist

LEVANT WORMSEED FOR HOMOEOPATHIC PREPARATIONS CINA FOR HOMOEOPATHIC PREPARATIONS

The Application of QuEChERS in the Extraction of Anabolic Steroids in Whole Blood

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Improved Performance in Capillary Electrophoresis using Internal Standards

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

GCMSD-Headspace Analysis SOP

Experiment GC : Analysis of BTEX by GC-FID

Pelagia Research Library. Formulation development and evaluation of Tamsulosin Hydrochloride and Dutasteride in tablet dosage form

Acclaim RSLC. (Rapid Separation Liquid Chromatography)

More Speed and Resolution for Current Methods

Sensitive Analysis of Genotoxins by HPLC-ECD Using Boron-Doped Diamond Electrochemical Cell

Analysis of Benzenesulfonic Acid and P-Toluenesufonic Acid Esters in Genotox Monitoring using UPLC/UV-MS

Syed Ghulam Musharraf 1,2* and Umair Gulzar 2

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Automated Determination of Dissolved Gases in Water Anne Jurek

Natural Hair Transplant Medical Center, Inc Dove Street, Suite #250, Newport Beach, CA Phone

Video Notes. LC Troubleshooting Series Retention Time Shifts

2017, DIILI Publication. Original Paper PREDICTION OF SOLUBILITY OF ETODOLAC IN BINARY SOLVENTS USING EXTENDED HILDEBRAND SOLUBILITY APPROACH

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Rapid and Reliable Detection of Dissolved Gases in Water

Preliminary Biology Assessment Task #1. Part 1 is to be completed and handed in before the start of period 1 on Friday 13/05/2016.

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

VOLUMETRIC TECHNIQUES

DEVELOPMENT AND VALIDATION OF RP HPLC METHOD TO DETERMINE NANDROLONE PHENYLPROPIONATE IN DIFFERENT PHARMACEUTICAL FORMULATIONS

MV5: Automated concentration system

APPLICATION NOTE. GC Integrated Permeation Device

Public Assessment Report. Scientific discussion. Dutasteride Regiomedica 0.5 mg capsules, soft (dutasteride) NL/H/2861/001/DC.

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

INTRODUCTION TO THE SPECTROPHOTOMETER AND PIPETTING SKILLS

D. De La Matter 2004 Swimming Pool Chemistry STUDENT ACTIVITIES:

ANALYTICAL SCALE HPLC AGILENT SYSTEMS OPERATIONAL QUALIFICATION

EFFECTS OF CLEAROGEN ACNE LOTION ON TESTOSTERONE METABOLISM IN RECONSTRUCTED HUMAN EPIDERMIS

Agilent Dimension Software for ELSD User Manual

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

EFFECTS OF REVIVOGEN SCALP THERAPY ON TESTOSTERONE METABOLISM IN RECONSTRUCTED HUMAN EPIDERMIS

CHM250 Calibration and Measurement Lab. Balance Calibration

The Preparation of Low Concentration Hydrogen Sulfide Standards Gulf Coast Conference September 12, 2002 Galveston, TX Paper 050,12:45 pm Moody F

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Inquiry Module 1: Checking the calibration of a micropipette

Jaap de Zeeuw Restek Corporation, Middelburg, The Netherlands. Copyrights: Restek Corporation

RP-HPLC Method Development and Validation for Nitroxynil in Active Pharmaceutical Ingredient Manufacturing.

Determination of Selected ASTM Perfluorinated Compounds (PFCs) Using the Shimadzu LCMS No. LCMS-083. No. SSI-LCMS-083

Determination of Sodium using Atomic Emission

Precisely HPLC. Hints, Tips, Guidelines and Important Considerations. Presenters: Wilhad Reuter / Tom Breslin

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

Dissolution Failure Investigation. Ken Boda Dissolution Applications Engineer

Quraishi Zakir Rafeeque et al/ Innovational Journal of Chemistry 1(2) (2016) Available online at INNOVATIONAL PUBLISHER

Setting a New Standard in Flash Chromatography Performance

Linezolid 600 mg Tablets WHOPAR part 6 February 2017 (Hetero Labs Limited), TB299

Retention Time Locking: Concepts and Applications. Application

Svensk läkemedelsstandard

SOP: Buck Scientific BLC-20P HPLC Operation

Technical Procedure for Drug Chemistry Gas Chromatograph/Mass Spectrometry (GC-MS)

High speed UHPLC-MS/MS determination of multiple steroids in human serum using the Nexera MX system for multiplex analysis

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

SEMLATA3-12 Measuring, weighing and preparing compounds and solutions for laboratory use

Agilent 1290 Infinity LC System Applications requiring the Agilent Ultra-Low Dispersion Kit

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

WADA Technical Document TD2014EAAS. Endogenous Anabolic Androgenic Steroids Measurement and Reporting

Analysis of Melamine and Cyanuric Acid in Food Matrices by LC-MS/MS

A SIMPLE TITRATION METHOD FOR DETERMINING THE SPECIFIC GRAVITY ON ONE DROP OF URINE

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Bioequivalence: Saving money with generic drugs

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

May 1, By John Heim,Doug Staples

During today's webinar we're going to look at the following topics:

INTERNATIONAL STANDARD

Transcription:

Research Article CODEN: IJRPJK ISSN: 2319 9563 International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage: www.ijrpns.com SIMULTANEOUS ESTIMATION AND VALIDATION OF TAMSULOSIN AND DEUTASTERIDE IN BULK AND PHARMACEUTICAL DOSAGE FORM Dendukuri V. L. N. Mrudula* 1, G. Sai Prasad 2, P. V. Rao 1, S. Manohar Babu 1 *1 Department of Pharmaceutical Analysis, SIMS College of Pharmacy, Guntur, Andhra Pradesh, India. 2 Department of Pharmaceutical Analysis, Chandra labs, Andhra Pradesh, India. ABSTRACT The new precise, simple, accurate RP HPLC method for the simultaneous estimation of Tamsulosin Hydrochloride and Dutasteride in pharmaceutical dosage form. Solubility determination of Tamsulosin Hydrochloride and Dutasteride in various solvents and buffers. Determine the absorption maxima of both the drugs in UV-Visible region in different solvents/buffers and selecting the solvents for HPLC method development. Optimize the mobile phase and flow rates for proper resolution and retention times. Validate the developed method as per ICH guidelines. A simple and selective LC method is described for the determination of Tamsulosin Hydrochloride and Dutasteride tablet dosage forms. Chromatographic separation was achieved on a C 18 column using mobile phase consisting of a mixture of Phosphate buffer (KH2PO4) ph:3.5: Acetonitrile: Methanol (40:30:30v/v), with detection of 223 nm. Linearity was observed in the range 19.2-44.8 µg /ml for Tamsulosin Hydrochloride (r 2 =0.9961) and 24-56µg /ml for Dutasteride (r 2 =0.9981) for the amount of drugs estimated by the proposed methods was in good agreement with the label claim. From the above experimental results and parameters it was concluded that, this newly developed method for the simultaneous estimation of Tamsulosin Hydrochloride and Dutasteride was found to be simple, precise, accurate and high resolution and shorter retention time makes this method more acceptable and cost effective and it can be effectively applied for routine analysis. KEYWORDS RP-HPLC, Acetonitrile, Methanol, Ammonium acetate buffer ph3.5, C18 column and 223nm. Author for Correspondence: Dendukuri. V. L.N. Mrudula, Department of Pharmaceutical Analysis, SIMS College of Pharmacy, Guntur, Andhra Pradesh, India. Email: mruduladendukuri@gmail.com. INTRODUCTION Tamsulosin is a selective antagonist at alpha-1a and alpha-1b-adrenoceptors in the prostate, prostatic capsule, prostatic urethra and bladder neck. At least three discrete alpha1-adrenoceptor subtypes have been identified: alpha-1a, alpha-1b and alpha-1d; their distribution differs between human organs and tissue. Approximately 70% of the alpha1-receptors in human prostate are of the alpha-1a subtype. Available online: www.uptodateresearchpublication.com July - August 242

Blockage of these receptors causes relaxation of smooth muscles in the bladder neck and prostate. Dutasteride belongs to a class of drugs called 5- alpha-reductase inhibitors, which block the action of the 5-alpha-reductase enzymes that convert testosterone into dihydrotestosterone (DHT). The combination of dutasteride and tamsulosin is used to treat benign prostatic hyperplasia (BPH) in men with an enlarged prostate. A new method is developed for the simultaneous estimation and validation of tamsulosin and dutasteride 1-6. MATERIALS AND METHOD Instruments used UV-spectrophotometer Nicolet evolution100, HPLC shimadzu (LC AT VP), HPLC agilent1200 series, ultrasonicator citizen digital ultrasonic cleaner, ph meter global digital, electronic balance shimadzu, syringe Hamilton, HPLC column kromosilc18 column ((250 4.6mm 5µ). Reagents and Materials Water: HPLC grade, sodium hydrogen orthophosphate: AR grade, Methanol: HPLC grade, potassium dihydrogen orthophosphate: AR grade, Acetonitrile; HPLC grade, ammonium acetate; AR grade, tetra hydro furan: AR grade. Drugs used Tamsulosin hydrochloride and deutasteride bulk drug gift samples were obtained from Chandra labs, hyd, veltam plus (0.4+0.5) (tamsulosin 0.4mg and deutasteride 0.5mg label claims), manufactured by arron (intas pharmaceuticals ltd) India which is obtained from local pharmacy. Mobile Phase A mixture of 40 volumes of 20mM Ammonium acetate buffer ph 3.5: 30 volumes of Acetonitrile: 30 volumes of Methanol. The mobile phase was sonicated for 10 min to remove gases. Preparation of Ammonium acetate buffer (20mM) 0.15416 gm of Ammonium acetate was weighed and dissolved in 100ml of water and volume was made up to 100ml with water. Adjust the ph to 3.5 using ortho phosphoric acid. The buffer was filtered through 0.45µ filters to remove all fine particles and gases. METHOD Weigh accurately 40 mg of Tamsulosin Hydrochloride and 32 mg of Dutasteride in 100 ml of volumetric flask and dissolve in 10ml of mobile phase and make up the volume with mobile phase. From above stock solution 40 µg/ml of Tamsulosin Hydrochloride and 32 µg/ml of Dutasteride is prepared by diluting 5ml to 50ml with mobile phase. This solution is used for recording chromatogram. And the chromatographic conditions are mobile phase as ammonium acetate buffer: acetonitrile: methanol in the ratios 40:30:30 and kromosil C18 column (250 4.6mm 5µ) and wavelength at 223nm and the buffer ph 3.5. And the chromatogram was shown in the Figure No.1-2 and the efficiency and the retention time are satisfactory. METHOD VALIDATION System suitability Standard solutions were prepared as per the test method and injected into the chromatographic system. The system suitability parameters like theoretical plates, resolution and asymmetric factor were evaluated. Linearity and range Standard stock solutions were prepared by dissolving 40 mg of Tamsulosin Hydrochloride and 32 mg of Dutasteride dissolved in sufficient mobile phase. After that filtered the solution using 0.45- micron syringe filter and Sonicated for 5min and dilutions were made, five injections were taken for each drug and noted down the concentrations and areas and the linearity graphs were plotted shown in Figure No.3 and 4. Accuracy To check the accuracy of the method, recovery studies were carried out by addition of standard drug solution to pre-analyzed sample solution at three different levels 80%, 100%, 120%. The percentage recovery and mean recovery are estimated (Table No.1). Available online: www.uptodateresearchpublication.com July - August 243

Method precision Prepared sample preparations of Tamsulosin Hydrochloride and Dutasteride as per test method and injected 6 times in to the column. The % RSD is estimated (Table No.1). Limit of Detection =. Where, σ = the standard deviation of the response, S = the slope of the calibration curve. The slope S may be estimated from the calibration curve of the analyte. It is separately estimated for both the drugs. Limit of Quantification = Where, σ = the standard deviation of the response, S = the slope of the calibration curve Robustness Robustness of the method, prepared solution as per test method and injected at different variable conditions like using different conditions like Temperature and wavelength. Ruggedness Ruggedness can be defined as the difference between analyst to analyst. RESULTS AND DISCUSSION A simple and selective LC method is described for the determination of tamsulosin hydrochloride and dutasteride tablet dosage forms. The proposed methods were validated. The accuracy of the methods was assessed by recovery studies at three different levels. The method was found to be precise as indicated by the repeatability analysis, showing % RSD less than 2. All statistical data proves validity of the methods and can be used for routine analysis of pharmaceutical dosage form (Table No.3 and 4). Table No.1: Accuracy, Percentage recovery and Average % recovery of Tamsulosin hydrochloride Recovery S.No level 1 80 % 2 100 % 3 120 % Amount taken Accuracy Tamsulosin Hydrochloride 32 1245.776 32 1242.478 32 1243.744 38.4 1585.507 38.4 1592.771 Average area Amount recovered % Recovery 1243.999 32.11 100.34 1588.772 37.88 98.65 38.4 1588.039 44.8 1806.204 1863.448 45.57 101.72 44.8 1891.924 44.8 1892.215 Average% Recovery 100.23 % Available online: www.uptodateresearchpublication.com July - August 244

Table No.2: % Recovery of Dutasteride Accuracy Dutasteride S.No Recovery level Amount taken Average Amount recovered area % Recovery 40 1225.647 1 80% 40 1195.931 1209.380 39.29 98.23 40 1206.561 48 1534.413 2 100% 48 1527.826 1529.259 47.65 99.26 48 1525.537 3 120% 56 1795.856 1802.554 56.52 100.92 Table No.3: Assay results of Tamsulosin and Dutasteride S.No Parameters Standard Sample Standard Sample 1 Injection-1 1218.293 1229.507 1183.851 1216.259 2 Injection-2 1248.324 1246.813 1228.600 1215.705 3 Injection-3 1289.749 1236.109 1270.837 1215.781 4 Injection-4 1222.300 1228.810 1175.298 1196.616 5 Injection-5 1221.445 1241.937 1198.939 1204.885 6 Average 1240.022 1236.635 1211.505 1209.849 7 Tablet average weight 3.5 3.5 8 Standard weight 32 40 9 Sample weight 280 280 10 Label amount 0.4 0.5 11 std. purity 99.2 99.3 12 Amount found in mg 0.40 0.50 13 Assay (% purity) 98.93 99.16 Available online: www.uptodateresearchpublication.com July - August 245

Table No.4: Result of Tamsulosin and Dutasteride using mobile phase S.No Name Rt (min) Peak Asymmetry Efficiency Resolution 1 Tamsulosin Hydrochloride 2.653 1223.618 1.195 2813-2 Dutasteride 4.693 1191.699 1.241 3021 6.925 Figure No.1: Chromatogram of Tamsulosin and Dutasteride using mobile phase Figure No.2: UV-Visible spectrum of Tamsulosin and Dutasteride isobestic point Available online: www.uptodateresearchpublication.com July - August 246

Linearity of Tamsulosin y = 45.224x - 135.45 2500 R 2 = 0.9961 2000 1500 1000 500 0 0 10 20 30 40 50 Conc Figure No.3: Linearity of Tamsulosin Linearity of Dutasteride y = 32.376x - 21.159 R² = 0.9981 2000 1800 1600 1400 1200 1000 800 600 400 200 0 0 10 20 30 40 50 60 Conc Figure No.4: Linearity of Dutasteride CONCLUSION From the above experimental results and parameters it was concluded that, this newly developed method for the simultaneous estimation of Tamsulosin Hydrochloride and Dutasteride was found to be simple, precise, accurate and high resolution and shorter retention time makes this method more acceptable and cost effective and it can be effectively applied for routine analysis in research institutions, quality control department in meant in industries, approved testing laboratories, biopharmaceutical and bio-equivalence studies and in clinical pharmacokinetic studies in near future. ACKNOWLEDGEMENT Authors are highly thankful to Chandra labs for supporting for the fulfilment of this work. REFERENCES 1. Sravan Kumar Reddy G, Ashutosh Kumar S. RP-HPLC method for Analytical Method Development and Validation for the Simultaneous Estimation of Tamsulosin and Dutasteride in Bulk and pharmaceutical dosage forms, International journal of pharmacy and pharmaceutical sciences, 6(3), 2014, 77-84. Available online: www.uptodateresearchpublication.com July - August 247

2. Shivakumar Reddy L, Prasad Reddy S L N. Development and Validation of a Stability Indicating Liquid Chromatographic Method for Simultaneous Estimation of Dutasteride and Tamsulosin in Combined Dosage Form, Oriental Journal of Chemistry, 29(4), 2013, 1665-1673. 3. Dipti Patel, Natubhai Patel. RP-HPLC Method development and validation for simultaneous estimation of Tamsulosin hydrochloride and Finasteride in bulk drug and in combined dosage forms, Acta Pharmaceutica, 60(2), 2010, 197-205. 4. Sreelakshmi, Uma Maheswara Rao V. A validated rp-hplc method for simultaneous estimation of Tamsulosin and Dutasteride in tablet dosage form, Inventi Rapid Journals: Pharm Analysis and Quality Assurance, 2013. 5. Supriya M. Mhamunkar, Roshani Y. Vyavaharkar et.al. Analytical method development and Validation for the simultaneous determination of Tamsulosin HCl (TAM) and Tolterodine Tartrate (TOL) by using RP-HPLC, International Journal of Pharmacy and Pharmaceutical Sciences, 4(5), 2012, 319-322. 6. Dipti Patel, Patel N J, et.al. RP-HPLC Method for the Estimation of Dutasteride in Tablet Dosage Form, Indian J Pharm Sci, 72(1), 2010, 113-116. Available online: www.uptodateresearchpublication.com July - August 248