Research Teaching Production

Similar documents
Manual Solvent Purification System. Innovative Technology, Inc.

SOLVENT PURIFICATION SYSTEMS

Solvent Purification

MB-SP Series Solvent Purification System

Solvent Dispensing System Manual. Designed by J. C. Meyer

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

QUALITY YOU CAN COUNT ON.

Solvent System Walkthrough

Major Design Features

TECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Technical Bulletin AL-134

Basic & Controlled Atmosphere Glove Boxes

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

FAST EVAPORATION AT NORMAL PRESSURE

The Safe Use of Pyrophoric Substances

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Digital Vacuum Regulator

Neotecha Tank Sampling Sapro

School of Chemistry SOP For Operation Of Glove Boxes

ARC Unofficial Manual to the Solvent Dispensing System. Designed by J. C. Meyer

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

1. The Safe Use of Pyrophoric Reagents


ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

POWER FLUSH KIT INSTRUCTIONS

Standard Operating Procedure Inert Vacuum Line. Ryan Mulvenna, May 2012

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Nonrefillable Cylinders

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

Neotecha Tank Sampling Sapro

Chlorinator MODEL MK-I

DIAPHRAGM GAS SAMPLING PUMPS

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Chromatography Consumables

Schlenk Line. Standard Operating Procedure. Lab: Engineering Sciences Building 155. Department: Materials Science and Engineering. PI: Paul V.

Solvents in Returnable Containers

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-15

Alkylphosphines. Storage and Handling Recommendations

THERMODYNAMICS OF A GAS PHASE REACTION: DISSOCIATION OF N 2 O 4

Instruction Manual TECH0002 / Version 1.0. Sample Concentrator FSC400D & FSC496D

2B Technologies, Inc.

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

Glove Box with Gas Purification System and Digital Control VGB-6. MTI Corporation

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Standard Operating Procedure

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

The Ultimate Way To Degasify Compressor Seal Oils

6900 Maintenance Instruction System Flush

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

MK 3 Passive Operating Guide

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Safe Use of Solvent Stills

What I have learned about SF 6 gas testing.a Practical explanation

B-Series. breathing air systems flow capacity: scfm

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

Vapor Pressure of Liquids

Air Operated Hydraulic Pumping Systems to 50,000 psi

Microscopy Cryogenic WORKSTATION. Performance by Design

WHP Operations and Methods { July William M. Smethie, Jr. Lamont Doherty Geological Observatory Palisades, New York U.S.A.

ATIS OPERATION MANUAL

Standard Operating Procedure

PTFE-SINGLE GLASS FLOW METERS

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

MEDICAL EQUIPMENT CATALOG

Super-Clean Gas Filters from Restek

Liquid Level Controllers

PROCESS GAS SAMPLING SYSTEMS

Series Environmental Chambers

STANDARD OPERATING PROCEDURES

Figure 1. Basic vacuum/inert gas manifold (Adapted from chemistryviews.org)

CORESTA RECOMMENDED METHOD Nº 67

Armfield Distillation Column Operation Guidelines

The Safe Use of Pyrophoric Reagents

MV5: Automated concentration system

University of Minnesota Nano Center Standard Operating Procedure

BIOCLOSURE SYSTEM ASSEMBLIES

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Gases and welding distributors continue

ADAPTABILITY & PRECISION

MODEL 1329 Tank Gauge

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

How to use Solvent Purification System A brief manual

Zebron Gas Management

Transcription:

SOLVENT PURIFICATION SYSTEMS & PURIFICATION GRADE SOLVENTS From INNOVATIVE TECHNOLOGY, INC For SAFE Processing of DRY, DEOXYGENATED SOLVENTS Research Teaching Production WWW.SOLVENTPURIFICATION.COM

Technology Sigma-Aldrich is a distributor of Innovative Solvent Purification Systems. SOLVENT PURIFICATION SYSTEMS The removal of water and oxygen from flammable solvents using low-pressure column technology is proven to be a safe and effective alternative to thermal distillation methods that can result in fire or exposure to vapors. The well-engineered systems from Innovative Technology allow for highly flexible, inherently safer solvent purification for research, teaching, and production. Specify up to seven different solvents in a single solvent purification system.

Basic System Operation and Specifications: A Purification Grade solvent is pushed from its storage container under low nitrogen pressure through two stainless steel columns containing activated alumina and copper. Trace amounts of water and oxygen are removed producing dry, deoxygenated solvent. The processed solvent is drained into in a storage flask where it can be dispensed, under nitrogen, using standard syringe techniques. Dual solvent column design Manifolds, vacuum and gas Gas connection Stainless steel tubing Check valves Directional valves Dispensing Two pressure tested stainless steel columns per solvent, either 200L or 400L processing capacity until spent. Columns are supplied fully conditioned, ready for use. Spent columns are replaced with new columns. Internal vacuum and gas manifolds are built into the extruded aluminum frame of the system. Includes a vacuum indicator and gas regulators and pressure relief valves dedicated to each of the solvent flasks to prevent over pressurization of glassware. All solvents can be dispensed simultaneously using one main inert gas supply. A red colored 2-way Swagelok valve located on the main gas supply allows operator to shut off all pressure to system in an emergency. All solvent tubing is ¼ inch stainless steel. Each solvent has it s own in-line check valve to prevent back flow, thus eliminating cross contamination of solvents. Each solvent includes both 2-way and 3-way Swagelok directional valves to control flow of solvents and inert gas. Innovative Technology now offers the safest most functional dispensing system available. A 5-Way Swagelok valve promotes correct dispensing procedures and prevents multiple functions from occurring simultaneously, thus causing problems like evacuation of solvent through the vacuum pump. A Swagelok metering valve allows a controlled flow of solvent from a braided stainless steel flex line connected to your desired dispensing joint ( 24/40 29/32 14/20 Luer Lock Needle Valve). A glass solvent storage flask mounts to the joint for dispensing solvents using standard syringe techniques.

Grounding The system is grounded and bonded against ESD, enabling the user to make a cold water pipe, or earth ground. Permits grounding a solvent reservoir while filling it away from the system Specify a PURE SOLV System in 4 Easy Steps STEP 1: Select Solvents SIGMA-ALDRICH PURIFICATION GRADE SOLVENTS A new line of specially prepared and packaged solvents that enhance the performance, safety, and convenience of PURE SOLV systems. Specify up to seven different solvents in a single PURE SOLV solvent purification system. Low water and oxygen content Degassed* to save processing time Extends column life Convenient pack sizes *For 18L Pure-Pac container only. Solvent Container Types 5 Gallon refillable reservoir provided by Innovative Technology, including all quick disconnect valves. Perfect for refilling with Sigma Aldrich Glass disposable bottled solvent. 2 Gallon refillable reservoir provided by Innovative Technology, including all quick disconnect valves. Perfect for refilling with Sigma Aldrich Glass disposable bottled solvent. 18 liter Pure-Pac returnable container - stainless steel container attaches to systems with simple quick-connect fittings. 4L Glass disposable bottles for manually filling 5 gallon (19L) solvent reservoirs. Bottled solvents are not degassed and must be de-gassed prior to use. Instructions are included with owner's manual.

Specify Pure Solve Solvents Solvent Type: Expected Titration Results Alumina Sieves De-Gas Copper Acetonitrile 15 ppm * + Benzene 4 ppm * + # Chloroform 2 ppm * + Dichloromethane 2 ppm * + DME 30 ppm * + DMF 30 ppm * + Ether - Inhibitor-free 8 ppm * + Heptane 2 ppm * + # Hexane 2 ppm * + # Hexanes 2 ppm * + # Methanol 40 ppm * + Pentane 2 ppm * + # Chlorobenzene 6 ppm * + THF - Inhibitor-free 7 ppm * + Toluene 2 ppm * + # * = Solvent will be dried using identified material. + = All Solvents must be de-gassed for oxygen removal using inert gas. Degas times are located in Manual. # = Identified solvents may be passed through Copper Catalyst for optimum oxygen scrubbing.

STEP 2: Select Column Processing Capacity The processing capacity of PS-400 Systems is 400L per solvent, PS-200 Systems is 200L per solvent. Spent columns may be discarded and replaced with new fully conditioned columns. Description PS-400 Systems PS-200 Systems One Solvent System PS-400-1 PS-200-1 Two Solvent System PS-400-2 PS-200-2 Three Solvent System PS-400-3 PS-200-3 Four Solvent System PS-400-4 PS-200-4 Five Solvent System PS-400-5 PS-200-5 Six Solvent System PS-400-6 PS-200-6 Seven Solvent System PS-400-7 PS-200-7 STEP 3: Select System Configuration Select a free standing or bench top system.

STEP 4: Select System Accessories. Select a Diaphragm Pump for evacuation of Glassware prior to dispensing solvent. DRYFAST ULTRA * PTFE Vacuum Pumps Corrosion resistant PTFE Diaphragm Pump Small foot print and compact Steady reliable vacuum Gas ballast inhibits gas vapor condensation Quiet Select a Flammable Safety Cabinet. Select Glove Box Integration.

Dispensing Options. Please ask us about our custom air free dispensing solutions.. Select Solvent Storage Flasks. For Storage and dispensing air-sensitive solvents. With 24/40 ground glass joints and septum inlet PTFE stopcock. Custom designs also available

Quotations & Technical Service Technical: 978-462-4415 FAX: 978-462-3338 Email: info@gloveboxes.com Internet: www.solventpurification.com www.gloveboxes.com

KEEP AWAY FROM HEAT, SPARKS and OPEN FLAME. DO NOT INHALE VAPOR. How many times have you seen one or both of these injunctions? Yet, every time you perform a thermal distillation on a flammable solvent, you violate the former, and possibly the latter. And to complicate matters, our colleges and universities are still teaching thermal distillation. There is a better way - solvent purification systems using pressure column technology 1. The method is proven to be effective and is clearly safer 2. The well-engineered systems from Innovative Technology allow for highly flexible, inherently safer solvent purification for research, teaching, and production. These devices can be home built. The University of California System is adopting a design and safety guideline 3. However; these commercial units make financial and technical sense. The systems use proven engineering, with high quality control standards. They are backed by the integrity and reputation of the manufacturer. And, they are available for use immediately upon installation. All of these advantages outweigh any savings of do-it yourself. I cannot decide if YOU need a pressure column purification system. I can only point out that the cost of a single fire is many times the cost of a purification system. If you continue to violate the above-stated injunction, you will have a fire. Neal Langerman Ph.D. Advanced Chemical Safety 7563 Convoy CT San Diego, CA 92111 1 Pangborn, A.B., Giardello, M.A., Grubbs, R.H., et al; Organometallics, 15(5), 1518-1520, 1996. 2 Alaimo, Peter J.; Peters, David W.; Arnold, John; Bergman, Robert G.; J. of Chem. Ed. 2001 78 64. 3 University of California Push-Still Design Guides. D. Decker, personal communication (for more information, contact dmdecker@scarlet.ucdavis.edu)