Hygea Ultrasonic Validation Kit

Similar documents
Ultrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths

SUGGESTED POLICY FOR THE MONITORING OF THE CLEANING EFFICIENCY OF AN ULTRASONIC CLEANERS( SONIC & TOSI) WEEKLY

Competency Record for Sonic Cleaning

UsER manual for Watersens ph -REDOX

Qi Litre Ultrasonic Cleaner

Eurosonic 4D - 3D - Micro ENGLISH

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

the annulus between the second casing string and the surface casing [must be] open to the atmosphere in the manner described in subsection (2).

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

ANALOG ULTRASOUND WATTMETER USP-30

TQC Bresle Chloride test 2008

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

CP10 Sensor Installation and Maintenance Instructions

DISSOLUTION TEST FOR SOLID DOSAGE FORMS

SDX Submersible Depth Transmitter User Manual

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Best Practice for Calibrating LTH Conductivity Instruments

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

DTG - LCD Digital Temperature Gauge USER MANUAL

Tourniquet Systems Pressure Infusion

711 DISSOLUTION. Portions of the present general chapter text that are national USP text, and therefore not part of the

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

SDX Submersible Depth Transmitter User Manual

Elcometer 138. Bresle Kit and Patches. Operating Instructions

STERILIZABLE DISSOLVED OXYGEN SENSORS

PP-1, PP-1W, PP-2, & PP-3

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

Field Manual. Simple by Design

Royce Interface Level Analyzer and Sensors

GILMONT ACCUCAL FLOWMETERS

HOW TO DIG A TEST PIT

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

Sooriyan Pool and Spa Ionizer. by Hilltop Solar

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Optical Dissolved Oxygen Meter

User Manual V14.1 IP68 LED FLEX NEON

MAKE YOUR SAMPLE COUNT! A PRIMER ON COLLECTING QUALITY, REPRESENTATIVE SAMPLES

Model PDT Dewpoint Transmitter

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

BRIEFING 711 DISSOLUTION

Equipment Accuracy / Selection

Supratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

UltraLo 1800 Alpha Particle Counter

Optical Dissolved Oxygen Meter

Internal Sealing of Masts

EcoCell Vertical Electrophoresis Unit

Ultima Salt System Overview

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

Risk Analysis and Hazard Reduction Report V1.0

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

SEMEM3-73 Maintaining medical gas pipeline systems and equipment

CanNeed-DSST-100 Digital Secure Seal Tester --- To evaluate the secure seal quality of PET bottles, glass bottles and cans

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Experiment 18 Properties of Gases

Expert Hydrostatic Level Transmitters

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Digiquartz Water-Balanced Pressure Sensors for AUV, ROV, and other Moving Underwater Applications

Maintenance and Calibration

SCOUT DECK ANCHOR 3 1/4" BONDING SCREW

POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

11. Aquasalt. Aquasalt Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and Accessories 443. Chemical Products

Food and Drug Administration Division of Pharmaceutical Analysis. Mechanical Qualification of Dissolution Apparatus 1 and 2

Gilson Aqua-Check Moisture Tester MA-26X

INDEX THE FINITO UNIVERSE BLANKET PLATE COATING PRESS WRAPPING

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

ST 18 Aluminium Gas Model

Decontamination Procedures for Gilson Pipettes

MULTICHANNEL. Labnet International, Inc.

BS Series Basket Strainer

Generating Calibration Gas Standards

Installation Operation Maintenance

Nuclear Associates , &

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SEMMME3-073 Checking that completed assemblies comply with specification

SS32L Dissolved O 2 Probe

Advanced Test Equipment Rentals ATEC (2832)

RayPette Plus Autoclavable Pipette. User Manual

Work Method Statement. Prepared for: The Bolton NHS Foundation Trust Prepared by: Mark Fentiman Date:

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

CCPaSEC. Procedure for the Quality Control Yearly Equipment Check. July 2018 CCPaSEC Quality Control Team

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Model VR6 System. Installation, Operation & Maintenance

Transcription:

Hygea Ultrasonic Validation Kit Ultrawave s Hygea Ultrasonic Validation kit contains the tools and accessories required to perform Validation and Periodic testing of your ultrasonic cleaning bath. Designed to meet the testing guidelines for measuring the ultrasonic activity and cleaning efficacy of an ultrasonic bath as stipulated in HTM guidelines, the Hygea Ultrasonic Validation kit assures the operator that the ultrasonic bath is performing effectively. Why measure? The need to confirm the performance of all processing equipment in healthcare and industrial manufacturing environments is all important. HTM01-05 recommends that a measurement of ultrasonic activity and cleaning efficacy for dental ultrasonic baths is taken on a regular basis. Ultrasonic activity is measured using the Hygea Ultrasonic Activity Meter and aluminium foil test, while STF Load Check indicators are used to measure cleaning efficacy. All results can then be recorded in the Validation logbook provided. Kit Contents The Hygea Ultrasonic Validation Kit consists of the following components which will allow you to periodically test your ultrasonic cleaning system to ensure optimum performance: 1 x Hygea Ultrasonic Activity Meter Aluminium foil roll 2 x STF Load Check Holders STF Load Check Strips Ultrasonic Testing log book all packaged in a handy carry case.

Ultrasonic Activity Detection Foil Ablation Test The activity of an ultrasonic cleaner may be investigated by the erosion pattern which is created on aluminium foil exposed in the bath for a short period. The activity will not be uniform throughout the ultrasonic bath. Tests carried out during commissioning are intended to establish the variation in activity at different positions within the bath and the time required to obtain a characteristic erosion pattern. Tests should be carried out quarterly to ensure the ultrasonic activity remains unchanged. Equipment and materials The following equipment and materials are required: 1. Aluminium foil of nominal thickness 0.015 mm to 0.025 mm (A 20mm wide, 240m reel can be ordered from Ultrawave: Part number C7015701, aluminium foil). 2. Waterproof adhesive tape (autoclave indicator tape is ideal). 3. A stopwatch, graduated in 0.2s or better and with an accuracy over a period of 15 min of ± 0.5 s, or better. 4. A rule or tape measure graduated in mm. Method 1. Measure the depth of the bath from the level of the lid to the bottom of the bath. Let the depth be D mm. 2. Cut nine strips of aluminium foil 15 mm to 20 mm wide and {D + 120} mm in length. 3. Roll 120mm of prepared foil strip into a cylindrical shape and secure with a paper-clip. Repeat for all nine strips.

4. Ensure that the water in the tank is at the required level, that the required amount of any chemical additive has been added and that the water in the tank is at the specified operating temperature. 5. Start the ultrasonic cycle and carry out the degas procedure to eliminate dissolved gases from the liquid in the bath. 6. Using strips of autoclave indicator tape across the top of the bath suspend nine strips of the prepared foil in the bath in a 3 x 3 grid. 7. The rolled end of each foil strip acts as a sinker weight to maintain the foil in an approximately vertical position. The sinker weight should be not more than 10 mm above, but not touching, the bottom of the bath 8. Run an ultrasonic cycle for a minimum of 30 seconds. Foil strips in position Inadequate or uneven erosion patterns 9. Remove the strips from the bath, blot dry and examine. 10. Drain the bath and clean to remove debris of eroded aluminium foil. Results Positive or satisfactory erosion patterns The zones of maximum erosion should be at similar positions on all nine foils and each should be eroded to a similar extent (by visual inspection). On re-testing the extent of erosion and the erosion pattern should have remained consistent with those originally determined during commissioning. Notes. The strips may be filed conveniently by sticking them to an A4 sheet of plain paper using a transparent adhesive tape. Laminating will provide a permanent record. The erosion pattern will depend on the thickness of the foil, the hardness of the foil, and the temperature of the liquid in the ultrasonic bath.

Ultrasonic Load Check Indicator Cleaning Efficacy Test The ultrasonic load check indicator is a consistent, repeatable way to monitor the cleaning efficacy of your ultrasonic bath. The indicator strips have been designed to perform in an equivalent manner to the test soils described in documents such as HTM2030 and HTM01-05. They represent typical soiling that would occur during normal use of reusable surgical instruments. These ultrasonic indicator strips contain two sources of protein - lipids and polysaccharides. Safe to handle and made with no blood products, the indicator strips allow easy to interpret results to be obtained, time after time. Test strips can be used with no risk of adding blood borne contaminants to the bath. The test strips can be used in the mesh design holder and should be placed in a basket within the ultrasonic bath. If the strips are being used in a hygea 2 benchtop bath, the strips should be placed on the middle instrument tray and the two other trays removed. As the ultrasonic activity occurs, the red test soil will be removed from the strips and different levels of soil removal will indicate different levels of ultrasonic activity. This is a bench marked performance test which is suitable for validation. The indicator strips mimic occluded surfaces to present a realistic ultrasonic cleaning challenge. In order to obtain meaningful results, test strips should be stored in a dry environment, preferably in a sealed container.

Instructions for use: 1. Ensure the ultrasonic bath has sufficient Water. 2. Ensure the detergent has been thoroughly mixed in the water and that the correct dosage has been applied (50ml of Sonozyme). 3. Ensure that the hygea 2 minimum temperature is set to 20 o C. 4. Ensure that the water has been degassed. This can be done by allowing the heating cycle to complete then running at least 1 x 10 minutes ultrasonic cycle. Allow the water to rest for no less than 3 minutes. 5. Ensure the strip holders and your hands are clean and dry. 6. Place one indicator strip in each holder, ensuring it is centrally placed and not protruding from either side. Place the holders in the basket as shown in Picture A. 7. After running a complete cycle (at least six minutes in the hygea 2), remove the holders from the basket and carefully take out the indicator strips. Caution: the device may be hot and any residual soil from the strips may stain. Picture A 8. Inspect the indicator strips for evidence of remaining soil by placing the strips against a white background. 9. If more than 2% of the soil remains, cleaning of the load should be considered inadequate and departmental procedures should be followed in respect of failed cleaning efficacy testing. (see picture B below) Note: It is important to check the expiry date of the strips and that the holders must be placed horizontally as shown above. Not doing so will affect the cleaning efficacy results. Fail Fail Fail Pass Pass Picture B

Hygea Ultrasonic Activity Meter Specifications Probe Assembly in Stainless Steel 15 244mm long Handle in ABS Plastic 105mm long Instrument Case in ABS Plastic 130 65 25mm Weight (probe and cable) 350 grams Weight (instrument including battery) 200 grams Indicator 1: Frequency 5-50 KHz Indicator 2: Power 10-100% Battery 9V PP3 Cable Connector BNC 2P Warranty 12 months Calibration Period 12 months Operating Instructions 1. The Hygea Ultrasonic Activity Meter should be used to measure the level of ultrasonic activity throughout the tank. It is recommended that the tank be divided into 9 sections and measurements taken at just below the surface and at least 3 cm from the base of the bath, where the depth of the tank allows. 2. Insert the probe into the cleaning fluid inside the tank. To take a reading press and hold the button on the meter. Record the results displayed on both the Frequency and Power displays. 3. Repeat this in the 9 specified places at the two different depths throughout the bath, including each corner. 4. Record the results so that future tests can be compared. If there is a reduction in the readings over time, your ultrasonic cleaning system may not be working at full efficiency and may need validation and servicing. Note: It should not be expected that the Meter will give readings of 100% every time. The Hygea Ultrasonic Activity Meter is designed to be used as a comparative measurement device over a period of time. If the readings change significantly, it is recommended that you contact Ultrawave for information and advice.